Search NASA⌕ Search

SEARCH · Search NASA

Results for “penetrator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Magnetic Properties of Cables with Meandering Wires through a Multipole-based Cable Braid Electromagnetic Penetration Model

In this paper, we employ our first principles multipole-based cable braid electromagnetic penetration model to evaluate the transfer inductance of cables exhibiting meandering wires. We concentrate on a cable structure with two wires, and consider the dependence on the transfer inductance as a function of braid angle and amplitude of the meandering. We compare the results from the first principles model to analytical estimations, confirming the accuracy and correctness of our model. In turn, this makes the multipole-based model readily available for the modeling of realistic cable geometries by accounting for the full dependence on the actual cable geometry.

36 MATERIALS SCIENCE↗

Resilient Operation of Networked Community Microgrids with High Solar Penetration

This project, funded by the US Department of Energy’s Solar Energy Technologies Office (SETO), focused on the operation of microgrids as a coordinated network. The primary objective, which was successfully achieved, was to develop both control strategies and hardware solutions to support the resilient and efficient operation of networked microgrids with high solar penetration. The work was structured around the following four main tasks: • Development of distributed and scalable optimization algorithms for AC-coupled networked microgrids. • Design and implementation of a novel DC interconnection hardware to enable precise power exchange between microgrids. • Laboratory operational validation of the developed technologies using 480 V testbeds and commercially available hardware. • Field operational validation of the complete solution in Adjuntas, Puerto Rico, interconnecting two kW-scale, split-phase microgrids of Casa Pueblo’s microgrids. This project addressed multiple technical challenges across the domains of optimization, control, hardware interconnection, and protection. One of its key contributions was delivering tangible, real-world solutions for networking microgrids. In contrast to purely theoretical or simulation-based work, this project included full-scale hardware operational validation both in the lab and in the field. The work conducted as part of this project—in collaboration with the University of Puerto Rico; the University of Tennessee, Knoxville; the University of Central Florida; and Casa Pueblo—has advanced the state of the art in networked microgrids. Key contributions include the development of distributed control strategies, practical solutions for real-world implementation challenges, and the introduction of a novel DC interlink approach for microgrid interconnection. The project featured both laboratory and field validation using commercial off-the-shelf components. The field deployment successfully validated that a group of microgrids can operate in a coordinated manner, enabling precise power flow between systems and mutual support during extreme events. This project resulted in 15 journal publications and 15 conference papers; 5 graduate students and 15 undergraduate students were supported. The codes of distributed optimization and forecasting were made open-source through OSTI.gov for distributed optimization and forecasting. All the publications are available in the ORNL-hosted project landing page. The DC interlink with state-of-charge balancing control was operationally validated in Adjuntas by interconnecting two real-world, 240 V split-phase microgrids. To the best knowledge of the team, this represents the first operational validation of AC microgrids interconnected via DC-interlinks. As a culmination of this project, a follow-on grant was awarded to support the technology transfer of the distributed optimization framework to a commercial microgrid controller, Stellar Edge, developed by the California-based company New Sun Road.

14 SOLAR ENERGY↗

Orbiting Lunar Ground Penetrating Radar SAR Feasibility

This report aims to answer the question: “Will ground penetrating radar (GPR) be able to measure lunar subsurface resources from a 10km or above orbit?” Similarly, “Could a reasonable satellite-based system achieve the radar parameters required for lunar orbital GPR?” This report is not proposing a system but exploring if one is possible.

47 OTHER INSTRUMENTATION↗

Low Frequency Cable Dual Shield Penetration Using Complete Transfer Immittance Model

This report discusses low frequency coupling and subsequent penetration of a dual shield cable using a transfer immittance model with reciprocal sources. Configurations include: 1) where the cable is above a ground plane and shorted at both ends, 2) a monopole arrangement where it is shorted at one end and open at the other end, and 3) a monopole arrangement where the open end is loaded by a disc. The open circuit voltage within the cable is estimated for each case.

42 ENGINEERING↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Corneal Penetration of a Poorly Permeable Drug Using Bioadhesive Multiple Microemulsion Technology

Corneal penetration is a key rate limiting step in the bioavailability of topical ophthalmic formulations that incorporate poorly permeable drugs. Recent advances have greatly aided the ocular delivery of such drugs using colloidal drug delivery systems. Ribavirin, a poorly permeable BCS class-III drug, was incorporated in bioadhesive multiple W/O/W microemulsion (ME) to improve its corneal permeability. The drug-loaded ME was evaluated regarding its physical stability, droplet size, PDI, zeta potential, ultrastructure, viscosity, bioadhesion, in vitro release, transcorneal permeability, cytotoxicity, safety and ocular tolerance. Our ME possessed excellent physical stability, as it successfully passed several cycles of centrifugation and freeze–thaw tests. The formulation has a transparent appearance due to its tiny droplet size (10 nm). TEM confirmed ME droplet size and revealed its multilayered structure. In spite of the high aqueous solubility and the low permeability of ribavirin, this unique formulation was capable of sustaining its release for up to 24 h and improving its corneal permeability by 3-fold. The in vitro safety of our ME was proved by its high percentage cell viability, while its in vivo safety was confirmed by the absence of any sign of toxicity or irritation after either a single dose or 14 days of daily dosing. Our ME could serve as a vehicle for enhanced ocular delivery of drugs with different physicochemical properties, including those with low permeability.

Ibrahim, Mohamed Moustafa↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources: Preprint

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Traveling Wave Relays for Distribution Feeder Protection with High Penetrations of Distributed Energy Resources

Increased penetration of power electronics interfaced Distributed Energy Resources (DER) like PV, electric vehicle and battery storage in the distribution system (both in numbers and sizes) may cause bi-directional power flows under normal operation. In addition, they contribute low fault current under short circuit conditions. These two changes can impact the proper operation of legacy protection systems. This can add additional challenges during weak grid and islanded operation. In this research, traveling wave (high frequency) signature based protection scheme is proposed for future distribution systems. Simulations are performed under different transient scenarios to provide insight into the high frequency signatures to show the traveling wave behavior. Finally, this paper discusses the importance of sensing and digital processing requirements for traveling-wave protection in distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Variable stiffness flyer plate for penetration device

A penetration device including a casing, a propellant positioned in the casing, and a flyer plate. The flyer plate is coupled to the casing and adjacent to the propellant. The flyer plate includes a center portion having a substantially constant first thickness and includes a peripheral portion around the center portion and defining an edge. The peripheral portion includes one or more recesses in a first surface of the peripheral portion.

Muha, Nicholas B.↗

Optimizing Rate of Penetration and Tripping Decision-Making using Real-Time Bit Wear Monitoring While Drilling Geothermal Wells

Understanding bit wear while drilling is critical to minimizing non-productive time (NPT) and optimizing rate of penetration (ROP). Lengthening drilling runs with damaged bits does not only lower the ROP, but also elevates the risk of inducing severe bit damage, which could potentially lead to time-consuming fishing operations. When drillers believe the bit has worn off substantially, the bit is tripped out to be replaced. On geothermal wells, tripping can take up to 20% of the overall well construction time, and this is generally acknowledged as an opportunity for improvement. Ideally, a bit run should be terminated before the bit is damaged beyond repair. At the same time, premature bit pulls are to be avoided as well. This study aims to leverage bit and tooth wear metrics that can be obtained in real time to characterize bit condition in order to optimize ROP and determine the optimal time to pull the bit. Two metrics were explored in this study: a bit wear metric that incorporated depth-of-cut, and a tooth wear metric developed by Bourgoyne & Young characterizing the state of bit teeth dull. Both metrics were computed using recorded data from 12¼ inches roller cone insert bit runs in five geothermal wells targeting a granodiorite formation in the western United States. Together with the actual dull grades, determined after the bits were pulled to surface, the metric trends were interpreted to characterize the downhole bit condition and identify the point at which the bit should have optimally been tripped out. The insights from studying the actual dull grades and how they relate to the two metrics were used to establish a reliable bit pull criterion. The bit wear metric trend correctly showed a noticeable departure from baseline for bits experiencing major dulling behavior. Additionally, the tooth wear model predicted the cutter dull within two dull grades for most runs, with better performance in predicting the inner teeth dull. Moreover, the combination of the bit wear and tooth wear metrics was effective in revealing the cause of the bit performance impairment. Proactive tracking of these two metrics in real-time can facilitate geothermal drilling ROP optimization and better-informed tripping decision-making, thereby avoiding wasted time and cost.

Ashari, Rahmat↗

Experiment and simulation of high-speed gas jet penetration into a semicircular fluidized bed

This work marks the third in a series of experiments that were in a semi-circular, gas-fluidized bed with side jets. In this work, the particles are (nominally) 1 mm ceramic beads. The bed is operated just at and slightly above and below the minimum fluidization velocity and additional fluidization is provided by two high-speed gas located on the sides of the bed near the flat, front face of the unit. Two primary measurements are taken: high-speed video recording of the front of the bed and bed pressure drop from a tap in the back of the bed. Particle Image Velocimetry (PIV) is used to determine particle motion, characterized as a mean Froude number, from the high-speed video. A CFD-DEM model of the bed is presented using the recently released MFIX-Exa code. Four model subvariants are considered using two methods of representing the jets and two drag models, both of which are calibrated to exactly match the experimentally measured minimum fluidization velocity. Although it is more difficult to determine the jet penetration depths in a straightforward manner as in the previous works using Froude number contours, the CFD-DEM results compare quite well to the PIV measurements, particularly for submodel flow Syam. Unfortunately, the good agreement of the solids-phase is overshadowed by significant disagreement in the gas-phase data. Specifically, the predicted time averaged standard deviation of the pressure drop is found to be over an order of magnitude larger than measured. Due to the low value of the measurements, just 1% of the mean bed pressure drop, it seems possible that the data is in error. On the other hand, the model may not be accurately capturing pressure attenuation through an under-fluidized region in the back of the bed. Without the possibility additional experiments to test the validity of the data, this work is simply being reported “as is” without being able to indicate which, either the simulation or the experiment, is more correct.<br>

Fullmer, William D.↗

Penetrating and actuating nozzle for extrusion-based 3D printing

An apparatus and device for creating a vertical strengthening feature within a 3D printed article of manufacture for improving mechanical performance in the Z-direction. Fill material is deposited in voids vertically crossing multiple layers during the build of 3D printing. The device includes a penetrating extension that fits within the void to create a vertical strengthening feature via heat and/or extruded fill material. The size and/or movement of the heated extension can impact the void side walls to reflow the build material and blend the layers together within the void side walls.

Kunc, Vlastimil↗

Methods, materials systems, and devices for inhibiting infiltration and penetration of molten salts into solid materials

Methods, materials systems, and devices for inhibiting the infiltration and penetration of molten salts into solid materials, including porous materials at temperatures above the solidus temperature of the molten salt. The methods, materials systems, and devices utilize a non-wetted solid that is introduced into pores having entrances at an exterior surface of a porous solid material adapted to contact the molten salt.

Sandhage, Kenneth Henry↗