Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Devices and methods for increasing the speed or power efficiency of a computer when performing machine learning using spiking neural networks

A method for increasing a speed and efficiency of a computer when performing machine learning using spiking neural networks. The method includes computer-implemented operations; that is, operations that are solely executed on a computer. The method includes receiving, in a spiking neural network, a plurality of input values upon which a machine learning algorithm is based. The method also includes correlating, for each input value, a corresponding response speed of a corresponding neuron to a corresponding equivalence relationship between the input value to a corresponding latency of the corresponding neuron. Neurons that trigger faster than other neurons represent close relationships between input values and neuron latencies. Latencies of the neurons represent data points used in performing the machine learning. A plurality of equivalence relationships are formed as a result of correlating. The method includes performing the machine learning using the plurality of equivalence relationships.

Vineyard, Craig Michael↗

Laboratory Testing of Portable Air Cleaner Products for Energy Efficiency and Clean Air Performance at Various Fan Settings [Slides]

This document contains the results of a product review and laboratory testing experiment of portable air cleaning devices (PACs). Thirty-four commercially available PACs were reviewed, and from those, 7 products were purchased and underwent AHAM AC-7 clean air delivery rate (CADR) testing. The following research questions were explored: 1) What is the relationship between clean air delivery rate (CADR) and energy across a range of products and what is the general decrement in CADR as a result of operating at lower fan speeds? 2) How might the multiple units at lower power compare to fewer, larger units at full power in terms of energy efficiency and total cost? 3) How do the measured CADR, power, and efficiency compare to the manufacturer specs? 4) Are there product attributes that can be identified that might contribute to better CADR/W performance?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of Mitigating System Performance Index to Improve Nuclear Power Plant Safety and Efficiency

MSPI (Mitigation System Performance Index) is one of the risk-informed, plant-specific performance indicators of NRC’s Reactor Oversight Process. MSPI is used by the regulator and nuclear industry to monitor and assess the performance of plant mitigating systems. In this project, a calculation tool has been developed by incorporating the plant operation data, Probabilistic Risk Assessment (PRA) data, and industry baseline values to automate the calculation process of MSPI and the generation of the report. This is the first stage in an effort to optimize the MSPI through advanced artificial intelligence (AI) and machine learning (ML) techniques to improve nuclear power plant safety and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TEAMER: Performance mapping of Re Vision's Persistance PTO

Contains datasets from experimental measurements that were used to validate Re Vision's Persistence PTO's efficiency and performance. These measurements were obtained using a dynamometer test bench setup. The data includes open-circuit voltage and loss measurements to validate machine characteristics, efficiency mapping tests to determine the generator's performance mapping, and efficiency mapping tests to determine the converter's efficiency over the feasible operating range. This data was collected between June 2023 and September 2023. The data was collected at the National Renewable Energy Laboratory's Flatirons Campus, Colorado, United States. The data was collected using NREL's 5-kW dynamometer test bench, equipped with a torque sensor and various voltage and current sensors fed to a dedicated data acquisition system. Units for the data are included in the data file headers for each data series. A text editor or spreadsheet software such as Excel is required to view the *.csv data. The data are also provided in *.mat files. To view data plots, a Matlab script with *.mat files are provided.

16 TIDAL AND WAVE POWER↗

Correlation between Sensor Performance, Autonomy Performance and Fuel-Efficiency in Semi-Truck Platoons

Semi-trucks, specifically class-8 trucks, have recently become a platform of interest for autonomy systems. Platooning involves multiple trucks following each n close proximity, with only the lead truck being manually driven and the rest being controlled autonomously. This approach to semi-truck autonomy is easily integrated on existing platforms, reduces delivery times, and reduces green- house gas emissions via fuel economy benefits. Level 1 SAE fuel studies were performed on class-8 trucks operating with the Auburn Cooperative Adaptive Cruise Control (CACC) system, and fuel savings up to 10-12% were seen. Enabling platooning autonomy required the use of radar, global positioning systems (GPS), and wireless vehicle-to-vehicle (V2V) communication. Poor measurements and state estimates can lead to incorrect or missing positioning data, which can lead to unnecessary dynamics and finally wasted fuel. This is especially an issue if deceleration is applied in response to a bad measurement. In this study, a faulty radar was shown to cause a greater than 5% increase in fuel consumption. The mechanism of this fuel consumption increase is investigated and applied to other types of sensor failures to indicate their potential effects on fuel economy. This analysis indicates that poor GPS signals over short time can be largely filtered out, with no real gain or loss of fuel economy. V2V communications were intentionally limited by causing interference, which resulted in dropped communication packets over a small physical area, but not an appreciable impact on fuel economy.

vehicle platooning, sensor performance, semi-auton↗

DEDUPKV: A Space-Efficient and High-Performance Key-Value Store via Fine-Grained Deduplication

Log-Structured Merge Tree (LSM-tree) based key-value stores excel in write-intensive environments but suffer from data duplication, consuming up to 49% of storage space in LSM-tree-based key-value store deployments. Traditional solutions like compression and coarse-grained file system-level deduplication introduce overhead or have limited effectiveness. In this study, we propose DedupKV, a fine-grained deduplication framework tailored for LSM-tree, maximizing data reduction efficiency while minimizing write stalls and read overheads. DedupKV features three key innovations: (1) FLUSH-integrated inline deduplication, which removes duplicates during memory-to-storage writes; (2) WAL file-based offline deduplication, repurposing write-ahead logs to avoid double writes; and (3) elastic execution, dynamically balancing inline and offline deduplication based on memory pressure and workload intensity. Additionally, dynamic granularity management reduces deduplication metadata overhead. We implemented these four ideas in RocksDB for the first time and conducted experiments in a Linux environment. Our evaluation shows that WAL file-based offline deduplication and DedupKV outperform BlobDB by 33% and 23%, respectively, in write-heavy workloads, while reducing write amplification by 1.2 ×, 2 ×, and 1.6 × for real KV datasets.

Jamil, Safdar [Sogang University]↗

LCC-based framework for building envelope and structure co-design considering energy efficiency and natural hazard performance

Herein, this paper presents a life-cycle cost (LCC) informed co-design framework for building structures and envelope systems, holistically considering the influences of energy and natural hazard performance. The proposed method is consisted of a two-stage design and decision-making process, aiming to provide a quantitative guideline for building's structural and envelope co-design based on the its geographic locations. First, the building's structural configuration and envelope type are selected based on the life cycle cost. Then, the long-term cost effectiveness of various energy-saving building envelope options (e.g., high-performance glazing and insulation) is evaluated to refine the envelope design. The proposed co-design framework was demonstrated through the case study of a medium-size office building archetype in three locations with distinct climate conditions and seismic activities (i.e., Los Angeles, Memphis, and Boston). The results highlighted the interplay between building's structural (seismic) performance and the cost-effectiveness of energy-saving design options – e.g., for buildings located in high-seismic regions, seismic enhancing designs greatly reduce the paybak period of high performance building envelope by reducing the seismic loss; whereas for buildings located in regions with cold climate and low seismic risk such as Boston, spatial frame with high insulation building envelope shows the lowest LCC.

42 ENGINEERING↗

Ultrahigh coulombic efficiency electrolyte enables Li||SPAN batteries with superior cycling performance

Raising the coulombic efficiency of lithium metal anode cycling is the deciding step in realizing long-life rechargeable lithium batteries. Here, we designed a highly concentrated salt/ether electrolyte diluted in a fluorinated ether: 1.8 M LiFSI in DEE/BTFE (diethyl ether/bis(2,2,2-trifluoroethyl)ether), which realized an average coulombic efficiency of 99.37% at 0.5 mA cm -2 and 1 mAh cm -2 for more than 900 cycles. This electrolyte also maintained a record coulombic efficiency of 98.7% at 10 mA cm -2 , indicative of its ability to provide fast-charging with high cathode loadings. Morphological studies reveal dense, dendrite free Li depositions after prolonged cycling, while surface analyses confirmed the formation of a robust LiF-rich SEI layer on the cycled Li surface. Moreover, we discovered that this ether-based electrolyte is highly compatible with the low-cost, high-capacity SPAN (Sulfurized polyacrylonitrile) cathode, where the constructed Li||SPAN cell exhibited reversible cathode capacity of 579 mAh g -1 and no capacity decay after 1200 cycles. A cell where a high areal loading SPAN electrode (>3.5 mAh cm -2 ) is paired with only onefold excess Li was constructed and cycled at 1.75 mA cm -2 , maintaining a coulombic efficiency of 99.30% for the lithium metal. Computational simulations revealed that at saturation, the Li-FSI complex forms contact ion pairs, with a first solvation shell comprising DEE molecules, and a second solvation shell with a mix of DEE/BTFE. This study provides a path to enable high energy density Li||SPAN batteries with stable cycling.

36 MATERIALS SCIENCE↗

COMPASS-FME Synoptic Sites Level 2 Sensor Data v2-1

This is the version 2-1 Level 2 (L2) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems. Level 2 (L2) data consist of sensor observations from the COMPASS-FME synoptic sites, TEMPEST, and DELUGE. Compared to the L1 data, these are more consistent (always 15-minute timestamps for the entire year); better QA/QC’d (out of bounds, out of service, and extreme outlier values are removed); and more complete, with a gap-filled time series available alongside the main observations, and additional derived (calculated) variables. L2 data are intended to be rapidly and easily usable in analyses and simulations. However, algorithmic outlier identification always carries the risk of removing valid data, and Level 1 data may be more suitable for analyses that focus on variability or extreme events. This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific Parquet (a high performance, space efficient format; see https://parquet.apache.org) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are reported every 15 minutes. Data files are in Apache Parquet, a high performance, space efficient format for tabular data. These files can be read using R's `arrow` package (https://arrow.apache.org/docs/r/), with similar tools available in other languages. Please see v2-1 L2 Sensor Package QStart.pdf for detailed information on data package structure, temporal coverage, and versioning.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 2 Sensor Data v2-1

This is the version v2-1 Level 2 (L2) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments. Level 2 (L2) data consist of sensor observations from the COMPASS-FME synoptic sites, TEMPEST, and DELUGE. Compared to the L1 data, these are more consistent (always 15-minute timestamps for the entire year); better QA/QC’d (out of bounds, out of service, and extreme outlier values are removed); and more complete, with a gap-filled time series available alongside the main observations, and additional derived (calculated) variables. L2 data are intended to be rapidly and easily usable in analyses and simulations. However, algorithmic outlier identification always carries the risk of removing valid data, and Level 1 data may be more suitable for analyses that focus on variability or extreme events. This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific Parquet (a high performance, space efficient format; see https://parquet.apache.org) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are reported every 15 minutes. Please see v2-1 TEMPEST L2 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. Data files are in Apache Parquet, a high performance, space efficient format for tabular data. These files can be read using R's `arrow` package (https://arrow.apache.org/docs/r/), with similar tools available in other languages. The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods. * Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021 * TEMPEST 1: June 22, 2022 * TEMPEST 2: June 6-7, 2023 * TEMPEST 3: June 11-13, 2024

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

Design Rules of the Mixing Phase and Impacts on Device Performance in High-Efficiency Organic Photovoltaics

In nonfullerene acceptor- (NFA-) based solar cells, the exciton splitting takes place at both domain interface and donor/acceptor mixture, which brings in the state of mixing phase into focus. The energetics and morphology are key parameters dictating the charge generation, diffusion, and recombination. It is revealed that tailoringthe electronic properties of the mixing region by doping with larger-bandgap components could reduce the density of state but elevate the filling state level, leading to improved open-circuit voltage ( V OC ) and reduced recombination. The monomolecular and bimolecular recombinations are shown to be intercorrelated, which show a Gaussian-like relationship with V OC and linear relationship with short-circuit current density ( J SC ) and fill factor (FF). The kinetics of hole transfer and exciton diffusion scale with J SC similarly, indicating the carrier generation in mixing region and crystalline domain are equally important. From the morphology perspective, the crystalline order could contribute to V OC improvement, and the fibrillar structure strongly affects the FF. These observations highlight the importance of the mixing region and its connection with crystalline domains and point out the design rules to optimize the mixing phase structure, which is an effective approach to further improve device performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low thermal inertia thermal barrier coatings for spark ignition engines: An experimental study

Application of thermal barrier coatings in spark ignition engines have historically been avoided due to the knock penalty associated with higher surface temperatures induced by the ceramic layer. However, advances in low thermal inertia coatings (i.e. temperature swing coatings) that combine low thermal conductivity with low volumetric heat capacity can prevent excessively high surface temperatures during the intake stroke and reduce or avoid knock while improving performance and efficiency. In this study, a novel coating material was tested in a low compression ratio spark ignition engine to evaluate the performance of an advanced low thermal inertia coating during steady and cold-start conditions. A total of four pistons with this novel material was tested, with an additional piston coated with gadolinium zirconate. Spark timing sweeps demonstrated a maximum 0.8% relative thermal efficiency gain with a thin coating of the novel material. Here, the novel material coated above 200-microns showed a deterioration in performance and efficiency due to charge heating increasing knock propensity. Cold-start tests demonstrated that charge heating is beneficial for reducing unburned hydrocarbons and particle matter emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refining HPCToolkit for application performance analysis at exascale

As part of the US Department of Energy’s Exascale Computing Project (ECP), Rice University has been refining its HPCToolkit performance tools to better support measurement and analysis of applications executing on exascale supercomputers. To efficiently collect performance measurements of GPU-accelerated applications, HPCToolkit employs novel non-blocking data structures to communicate performance measurements between tool threads and application threads. To attribute performance information in detail to source lines, loop nests, and inlined call chains, HPCToolkit performs parallel analysis of large CPU and GPU binaries involved in the execution of an exascale application to rapidly recover mappings between machine instructions and source code. To analyze terabytes of performance measurements gathered during executions at exascale, HPCToolkit employs distributed-memory parallelism, multithreading, sparse data structures, and out-of-core streaming analysis algorithms. To support interactive exploration of profiles up to terabytes in size, HPCToolkit’s hpcviewer graphical user interface uses out-of-core methods to visualize performance data. The result of these efforts is that HPCToolkit now supports collection, analysis, and presentation of profiles and traces of GPU-accelerated applications at exascale. These improvements have enabled HPCToolkit to efficiently measure, analyze and explore terabytes of performance data for executions using as many as 64K MPI ranks and 64K GPU tiles on ORNL’s Frontier supercomputer. HPCToolkit’s support for measurement and analysis of GPU-accelerated applications has been employed to study a collection of open-science applications developed as part of ECP. This paper reports on these experiences, which provided insight into opportunities for tuning applications, strengths and weaknesses of HPCToolkit itself, as well as unexpected behaviors in executions at exascale.

Adhianto, Laksono↗

Performance Assessment of High-Efficiency Refrigerated Display Cases with Low-GWP Refrigerants: Preprint

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas (GHG) reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison was to assess the energy performance of two high efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513a, respectively. Performance of these display cases were compared to a baseline fixture using HFC (R-134a) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores, and small supermarkets. The high efficiency cases were equipped with energy efficient lighting, improved panel insulation, high efficiency evaporator and condenser fan motors, and high effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions. However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining target product temperature, the energy efficient fixtures containing R-290 and R-513a consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134a refrigerant. The daily energy consumption of the R-290, R-513a, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗