SEARCH · Search NASA
Results for “performance study”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
HERMeS Thruster Magnetic Field Topology Optimization Study: Performance, Stability, and Wear Results
NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. The TDU-1 thruster implements a magnetically shielded field topology and has demonstrated the elimination of the discharge channel erosion as a life limiting mechanism. Extensive wear testing the TDU Hall thrusters has identified the thruster front pole covers as the next life limiting component. This effort aims to explore and investigate alternate magnetic field topologies to assess whether reductions in the front pole cover erosion can be attained while still maintaining very low erosion rates on the discharge channel walls. Four candidate magnetic field topologies that reduce the effectiveness of the shielding along the discharge channel walls with the intent to also reduce the erosion rates along the front pole covers were designed. Three of the four candidate magnetic field topologies (B1, B2, and B4) have been manufactured and were subjected to an extensive test campaign that includes laser induced fluorescence (LIF), performance, stability, wear, plume, and thermal characterization. In Phase I, LIF measurements along the discharge chamber centerline found that upstream retraction of the thruster's peak magnetic field does result in an upstream shift of the acceleration zone but the magnitude of the shift does not correspond one-to-one to the shift in the location of the peak radial magnetic field magnitude. Phase II test segment results found at a normalized thruster magnetic field setting of 1, the thruster performance was very similar for all configurations. Discharge current waveforms ripple data indicated that configurations Bo, B1, and B2 has similar oscillatory profiles with the B2 configuration transitioning to higher oscillatory mode at 400V instead of the 450V observed for configurations B0 and B1. Configuration B4 ripple data indicates that the thruster was operating in a very oscillatory mode above 350V. Inner front pole cover erosion rates for configuration B1 were approximately 65% relative to B0 and the erosion rates for configuration B2 were 40% relative to B0. Analysis of the performance, stability, and wear test results of configurations B0, B1, B2, and B4 indicates that configuration B2 may present an alternative option for B0 because it mostly maintained the same performance and stability as configuration B0 but with 40% of the inner front pole cover erosion rate.
AirMISR Spectral and Radiometric Performance Studies
An Airborne Multi-angle Imaging SpectroRadiometer (AirMISR) instrument has been developed to assist in validation of the Earth Observing System (EOS) MISR experiment.
Shockwave/Boundary-Layer Interaction Studies Performed at the NASA Langley Research Center
Explore the source record for details and available documents.
Prototype performance studies of a Full Mesh ATCA-based General Purpose Data Processing Board
Abstract Not Provided
Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)
The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.
Existing Whole-House Solutions Case Study: Performance of a Hot-Dry Climate Whole-House Retrofit, Stockton, California
The Alliance for Residential Building Innovation (ARBI) team conducted a deep retrofit project within Stockton’s Large-Scale Retrofit Program that expanded on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Post-retrofit site energy savings were 23% compared to the pre-retrofit case.
New Whole-House Solutions Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes
The Woods is a sustainable community built by Habitat for Humanity in 2013. This community comprises 30 homes that are high-performance and energy-efficient. With support from Tacoma Public Utilities and the Bonneville Power Administration, the BA-PIRC team is researching the energy performance of these homes and the ductless heat pumps they employ.
Building America Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes: Habitat for Humanity -- The Woods, Tacoma, Washington
The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes (c) Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP) research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.
Safeguards Inspectors Have Human Brains: Using Insights from Human Performance Studies for Inspection Planning.
Abstract not provided.
Studying Performance Portability of LAMMPS across Diverse GPU-based Platforms
The molecular dynamics simulation software, LAMMPS, utilizes the Kokkos acceleration library to port computation to a diverse set of architectures including those based on GPU accelerators. In addition to Kokkos, LAMMPS contains a vast code base that leverages the CUDA application programming interface using library functions such as cuFFT, CUDA’s fast-fourier transform (FFT) library, and, more recently, also support for AMD’s Heterogeneous Interface for Portability (HIP) that is rapidly growing. While preparing LAMMPS tests for the AMD GPU-based test system precursors to Frontier, we investigated several strategies for accelerating LAMMPS on AMD GPUs, using the AMD Instinct MI100 and MI250X. In this work, we integrated the HIP FFT library, hipFFT, into the particle-particle particle-mesh (PPPM) long-range solver, which allowed the porting of PPPM calculations to the GPUs. Kokkos behavior on the MI100 and MI250X was also investigated through the package kokkos command of LAMMPS, targeting com- munication, memory usage, and particle grid decomposition. The Tersoff, Reax, Lennard-Jones (LJ), EAM, Granular, and PPPM potentials were investigated in this effort, and results from these experiments are provided. The selected potentials were run on Spock (AMD Instinct MI100), Crusher (AMD Instinct MI250X), AFW HPC11 (NVIDIA A100) and Summit (NVIDIA V100), for comparison. Operational roofline models were constructed and analyzed for the Tersoff, Reax, and Lennard-Jones potentials on Crusher and Summit.
FUEL PERFORMANCE STUDIES AT IDAHO NATIONAL LABORATORY MAKING USE OF THE BYRON FUEL SHIPMENT
In December of 2023 a shipment of commercially irradiated fuel rods from the Byron Generating Station in Illinois was successfully shipped to the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL). The make-up of the rods includes a mix of cladding types from traditional ZirloTM, advanced zirconium alloys, and chrome coated ZirloTM. Burnups range from regular end of life values to over 70 GWd/MTU rod average. The R&D plan for the rods involves multiple projects from developing licensing data for new claddings to integral transient tests to support burnup extension efforts in the United States. The R&D began in early 2024 with the nondestructive examinations of the rods after which they will be sectioned for microscopy, mechanical testing, and analytical chemistry. Additionally, many rod segments will be refabricated into new test pins and inserted into a static water capsule for integral Reactivity Initiated Accident (RIA) and Loss of Coolant Accident (LOCA) testing at the TREAT reactor.
Photon Detection System Calibration for DUNE
Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.
SEASAT SAR performance evaluation study
The performance of the SEASAT synthetic aperture radar (SAR) sensor was evaluated using data processed by the MDA digital processor. Two particular aspects are considered the location accuracy of image data, and the calibration of the measured backscatter amplitude of a set of corner reflectors. The image location accuracy was assessed by selecting identifiable targets in several scenes, converting their image location to UTM coordinates, and comparing the results to map sheets. The error standard deviation is measured to be approximately 30 meters. The amplitude was calibrated by measuring the responses of the Goldstone corner reflector array and comparing the results to theoretical values. A linear regression of the measured against theoretical values results in a slope of 0.954 with a correlation coefficient of 0.970.
PMR polyimides with improved high temperature performance
Studies were performed to investigate the effect of substituting a hexafluoro isopropyl idene connecting group for a carbonyl group of a PMR polyimide monomeric reactant on the thermo-mechanical properties processability of graphite fiber reinforced PMR polyimide composites. Composites were fabricated utilizing PMR methodology. Monomeric reactant solutions of various stoichiometric ratios were used to impregnate Hercules HTS graphite fiber. The processing characteristics and elevated temperature (600 F) mechanical properties of the composites are described.
Development of a versatile system for detailed studies of the performance of heat pipes
Heat pipe performance studies for space suit thermoregulation applications
Exploratory study on performance measures as indicators of IS effectiveness
The Information Systems Directorate at JSC/NASA has undertaken the reevaluation of its performance measures process and measures. Under the direction of a quality approach it is essential to identify an external perspective of how well an organization is performing. This study was conducted with two major objectives: (1) survey and summarize the academic literature on performance measures as indicators of information systems (IS) effectiveness; and (2) survey organizations for their experience in measuring for IS effectiveness. Four approaches to measuring the effectiveness of IS performance were identified: (1) listen to the customer for the things they need; (2) align with corporate goals; (3) benchmark against well-respected organizations; and (4) ask yourself what critical factors lead to success. The list of known methods for soliciting customer feedback are as follows: (1) executive visit; (2) survey, interview, and focus group; (3) complaints and compliments; and (4) service level agreements. A common set of characteristics that satisfy customers was identified from the literature. The list includes elements such as the following: accuracy, timeliness, relevance, understandability, reliability, and completeness. Future research in this topic area should prove beneficial to determine the metrics for external validity.