Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz

The world s first silicon-based complementary metal oxide/semiconductor (CMOS) integrated-circuit voltage-controlled oscillator (VCO) operating in a frequency range around 324 GHz has been built and tested. Concomitantly, equipment for measuring the performance of this oscillator has been built and tested. These accomplishments are intermediate steps in a continuing effort to develop low-power-consumption, low-phase-noise, electronically tunable signal generators as local oscillators for heterodyne receivers in submillimeter-wavelength (frequency > 300 GHz) scientific instruments and imaging systems. Submillimeter-wavelength imaging systems are of special interest for military and law-enforcement use because they could, potentially, be used to detect weapons hidden behind clothing and other opaque dielectric materials. In comparison with prior submillimeter- wavelength signal generators, CMOS VCOs offer significant potential advantages, including great reductions in power consumption, mass, size, and complexity. In addition, there is potential for on-chip integration of CMOS VCOs with other CMOS integrated circuitry, including phase-lock loops, analog- to-digital converters, and advanced microprocessors.

Samoska, Lorene↗

Observations and Mitigation of RFI in ALOS PALSAR SAR Data; Implications for the Desdyni Mission

Initial examination of ALOS PALSAR synthetic aperture radar (SAR) data has indicated significant radio frequency interference (RFI) in several geographic locations around the world. RFI causes significant reduction in image contrast, introduces periodic and quasi-periodic image artifacts, and introduces significant phase noise in repeat pass interferometric data reduction. The US National Research Council Decadal Survey of Earth Science has recommended DESDynI, a Deformation, Ecosystems, and Dynamics of Ice satellite mission comprising an L-band polarimetric radar configured for repeat pass interferometry. There is considerable interest internationally in other future L-band and lower frequency systems as well. Therefore the issues of prevalence and possibilities of mitigation of RFI in these crowded frequency bands is of considerable interest. RFI is observed in ALOS PALSAR in California, USA, and in southern Egypt in data examined to date. Application of several techniques for removing it from the data prior to SAR image formation, ranging from straightforward spectral normalization to time-domain, multi-phase filtering techniques are considered. Considerable experience has been gained from the removal of RFI from P-band acquired by the GeoSAR system. These techniques applied to the PALSAR data are most successful when the bandwidth of any particular spectral component of the RFI is narrow. Performance impacts for SAR imagery and interferograms are considered in the context of DESDynI measurement requirements.

InSAR↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Resolution of 100 photons and quantum generation of unbiased random numbers

Macroscopic quantum phenomena, such as observed in superfluids and superconductors, have led to promising technological advancements and some of the most important tests of fundamental physics. At present, quantum detection of light is mostly relegated to the microscale, where avalanche photodiodes are very sensitive to distinguishing single-photon events from vacuum but cannot differentiate between larger photon-number events. Beyond this, the ability to perform measurements to resolve photon numbers is highly desirable for a variety of quantum information applications including computation, sensing, and cryptography. True photon-number resolving detectors do exist, but they are currently limited to the ability to resolve on the order of 10 photons, which is too small for certain proposals. In this work, we extend photon measurement into the mesoscopic regime by implementing a detection scheme based on multiplexing highly quantum-efficient transition-edge sensors to accurately resolve photon numbers between zero and 100. Further, we then demonstrate the use of our system by implementing a quantum random number generator with no inherent bias. This method is based on sampling a coherent state in the photon-number basis and is robust against environmental noise, phase and amplitude fluctuations in the laser, loss and detector inefficiency as well as eavesdropping. Beyond true random number generation, our detection scheme serves as a means to implement quantum measurement and engineering techniques valuable for photonic quantum information processing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Edge supercurrent reveals competition between condensates in a Weyl superconductor

In topological materials, the edge states are readily distinguished from the bulk states. The situation where a topological semimetal becomes superconducting so that Cooper pairs occupy both the bulk and the edge states is not well understood. In particular, we do not know if we can force their pairing symmetries to be different. Here we show that, when supercurrent is injected into the superconducting Weyl semimetal MoTe 2 from Nb contacts, the invasive s-wave pairing potential from Nb is incompatible with the intrinsic Cooper pair condensate in MoTe 2 . This incompatibility leads to strong stochasticity in the switching current and an unusual anti-hysteretic behaviour in the current–voltage loops. There is also an asymmetry in the edge oscillations where, as the magnetic field crosses zero, the phase noise switches from one with a noisy spectrum to one that is noise free. Furthermore, using the noise spectrum as a guide, we track the anomalous features to field-induced switching of the device gap function between s-wave symmetry and the unconventional symmetry intrinsic to MoTe 2 . We infer that the behaviour of the gap function along the edges is different from that in the bulk.

Superconducting properties and materials↗

A novel Doppler backscattering (DBS) system to simultaneously measure radio frequency plasma fluctuations and low frequency turbulence

A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60–90 GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of density fluctuations and their velocity in the lab frame. The system can simultaneously monitor both low-frequency turbulence (f < 10 MHz) and radiofrequency plasma density fluctuations over a selectable frequency range (20–500 MHz). Detection of high-frequency fluctuations has been demonstrated for low harmonics of the ion cyclotron frequency (e.g., 2f ci ~ 23 MHz) and externally driven high-frequency helicon waves (f = 476 MHz) using an adjustable frequency down conversion system. Importantly, this extends the application of DBS to a high-frequency spectral domain while maintaining important turbulence and flow measurement capabilities. This unique system has low phase noise, good temporal resolution (sub-millisecond), and excellent wavenumber coverage (k θ ~ 1–20 cm –1 and kr ≲ 30 cm –1 ). As a demonstration, localized internal DIII-D plasma measurements are presented from turbulence (f ≤ 5 MHz), Alfvenic waves (f ~ 6.5 MHz), ion cyclotron waves (f ≥ 20 MHz), as well as fluctuations around 476 MHz driven by an external high-power 476 MHz helicon wave antenna. In the future, helicon measurements will be used to validate GENRAY and AORSA modeling tools for prediction of helicon wave propagation, absorption, and current drive location for the newly installed helicon current drive system on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compensation of Anisotropy in Spin Hall Devices for Neuromorphic Applications

Spintronic nano-oscillators and diodes with reduced nonlinearity benefit from low phase noise and improved device properties. Moreover, they could offer key advantages for realizing neuromorphic applications, such as spike-based neurons and frequency multiplexing in neural networks. Here, in this work, we experimentally demonstrate the reduction in nonlinearity of a spin Hall nano-oscillator (SHNO) by compensation of its effective magnetic anisotropy. The study involves optimization of Co/Ni multilayer growth to achieve the compensation, followed by spin-diode measurements on patterned microstrips to quantify their anisotropy. The relationship between the second- (H k 2 = 0.47 mT) and first-order ($H^{eff}_{k_1}$ = -0.8 mT) anisotropy fields reveals the existence of an easy cone, thereby validating the presence of compensation. Furthermore, we demonstrate a compensated spin diode that has a fixed frequency when the input power is varied. We then study the current-induced auto-oscillation properties of SHNOs on compensated films by patterning nanoconstrictions of 200 and 100 nm wide. The invariance of the resonance frequency and linewidth of the compensated SHNO with applied dc current indicates the absence of nonlinearity. This independence is maintained irrespective of the applied external fields and their orientations. The compensated SHNO obtained has a linewidth of 1.1 MHz and a peak output power of up to 1 pW/MHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data Quality Analysis and Solutions for Distribution-Level PMUs

Synchrophasors provide promising enhancement to the distribution system monitoring. However, different from transmission systems, distribution systems are usually with higher noise, phase unbalance, and distributed energy resources. All of these could impair the data quality of distribution-level phasor measurement units (D-PMUs) and thus deteriorate the performance of D-PMU based applications. Therefore, the data quality of D-PMU should be evaluated to ensure the effectiveness of D-PMU based applications. In this paper, factors in distribution systems that could jeopardize D-PMU data quality are evaluated. The impact of data quality on D-PMU applications is analyzed. Finally, solutions are proposed to improve D-PMU data quality to satisfy these requirements. This work provides effective methods to improve the performance of distribution-level grid monitoring using synchrophasor measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Injection Locking Dynamics of Oscillation Loop with Saturable Gain

We analytically derive and experimentally verified the injection-locking range and phase-noise suppression ratio of an oscillation loop with saturable gain, establishing a general and straightforward approach for analyzing injection locking dynamics.

Xi, Zichen [ORNL]↗

Long-term hybrid stabilization of the carrier-envelope phase

Controlling the carrier envelope phase (CEP) in mode-locked lasers over practically long timescales is crucial for real-world applications in ultrafast optics and precision metrology. We present a hybrid solution that combines a feed-forward technique to stabilize the phase offset in fast timescales and a feedback technique that addresses slowly varying sources of interference and locking bandwidth limitations associated with gain media with long upper-state lifetimes. We experimentally realize the hybrid stabilization system in an Er:Yb:glass mode-locked laser and demonstrate 75 hours of stabilization with integrated phase noise of 14 mrad (1 Hz to 3 MHz), corresponding to around 11 as of carrier to envelope jitter. Additionally, we examine the impact of environmental factors, such as humidity and pressure, on the long-term stability and performance of the system.

47 OTHER INSTRUMENTATION↗

Ultra-low loss visible light waveguides for integrated atomic, molecular, and quantum photonics

Atomic, molecular and optical (AMO) visible light systems are the heart of precision applications including quantum, atomic clocks and precision metrology. As these systems scale in terms of number of lasers, wavelengths, and optical components, their reliability, space occupied, and power consumption will push the limits of using traditional laboratory-scale lasers and optics. Visible light photonic integration is critical to advancing AMO based sciences and applications, yet key performance aspects remain to be addressed, most notably waveguide losses and laser phase noise and stability. Additionally, a visible light integrated solution needs to be wafer-scale CMOS compatible and capable of supporting a wide array of photonic components. While the regime of ultra-low loss has been achieved at telecommunication wavelengths, progress at visible wavelengths has been limited. Here, we report the lowest waveguide losses and highest resonator Qs to date in the visible range, to the best of our knowledge. We report waveguide losses at wavelengths associated with strontium transitions in the 461 nm to 802 nm wavelength range, of 0.01 dB/cm to 0.09 dB/cm and associated intrinsic resonator Q of 60 Million to 9.5 Million, a decrease in loss by factors of 6x to 2x and increase in Q by factors of 10x to 1.5x over this visible wavelength range. Additionally, we measure an absorption limited loss and Q of 0.17 dB/m and 340 million at 674 nm. This level of performance is achieved in a wafer-scale foundry compatible Si 3 N 4 platform with a 20 nm thick core and TEOS-PECVD deposited upper cladding oxide, and enables waveguides for different wavelengths to be fabricated on the same wafer with mask-only changes per wavelength. These results represent a significant step forward in waveguide platforms that operate in the visible, opening up a wide range of integrated applications that utilize atoms, ions and molecules including sensing, navigation, metrology and clocks.

Chauhan, Nitesh↗

49 W carrier-envelope-phase-stable few-cycle 2.1 µm OPCPA at 10 kHz

We demonstrate a mid-infrared optical parametric chirped pulse amplifier (OPCPA), delivering 2.1 µm center wavelength pulses with 20 fs duration and 4.9 mJ energy at 10 kHz repetition rate. This self-seeded system is based on a kW-class Yb:YAG thin-disk amplifier driving a CEP stable short-wavelength-infrared (SWIR) generation and three consecutive OPCPA stages. Our SWIR source achieves an average power of 49 W, while still maintaining excellent phase and average power stability with sub-100 mrad carrier-envelope-phase-noise and 0.8% average power fluctuations. These parameters enable the OPCPA setup to drive attosecond pump probe spectroscopy experiments with photon energies in the water window.

47 OTHER INSTRUMENTATION↗

RF Digitizer for EIC LLRF

With the shutdown of Relativisitc Heavy Ion Collider (RHIC) in FY26, the former RHIC facility will be upgraded to the new Electron-Ion Collider (EIC). An RF Digitizer for the EIC LLRF system has been developed and tested on a RHIC 197 MHz cavity in Q2 2026 for a baseline per formance. Firmware and software has been developed and validated during the 197 MHz cavity test. Preliminary data from the cavity test shows phase noise performance signifi cantly better than the RHIC LLRF system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗