Search NASA⌕ Search

SEARCH · Search NASA

Results for “photon counting detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Photon detection with cooled avalanche photodiodes

Commercial avalanche photodiodes have been operated as single-photon detectors at an optimum operating temperature and bias voltage. These detectors were found to be 1.5-3 times more sensitive than presently available photomultiplier tubes (PMTs). Both single-photon detection probability and detector noise increase with bias voltage; detection probabilities greater than twice that of a PMT were obtained with detector noise levels below 100 counts per second. Higher probabilities were measured at higher noise levels. The sources of noise and their dependence on temperature and bias voltage are discussed.

Robinson, D. L.↗

NASA Tech Briefs, October 2013

Topics include: A Short-Range Distance Sensor with Exceptional Linearity; Miniature Trace Gas Detector Based on Microfabricated Optical Resonators; Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection; Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection; Mission Data System Java Edition Version 7; Adaptive Distributed Environment for Procedure Training (ADEPT); LEGEND, a LEO-to-GEO Environment Debris Model; Electronics/Computers; Millimeter-Wave Localizers for Aircraft-to-Aircraft Approach Navigation; Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces; SpaceCube Version 1.5; High-Pressure Lightweight Thrusters; Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites; Ambient Dried Aerogels; Applications for Gradient Metal Alloys Fabricated Using Additive Manufacturing; Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer; Propellant-Flow-Actuated Rocket Engine Igniter; Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads; Method to Increase Performance of Foil Bearings Through Passive Thermal Management; Unibody Composite Pressurized Structure; JWST Integrated Science Instrument Module Alignment Optimization Tool; Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique; Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures; Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation; Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum; Educational NASA Computational and Scientific Studies (enCOMPASS); Coarse-Grain Bandwidth Estimation Scheme for Large-Scale Network; Detection of Moving Targets Using Soliton Resonance Effect; High-Efficiency Nested Hall Thrusters for Robotic Solar System Exploration; High-Voltage Clock Driver for Photon-Counting CCD Characterization; Development of the Code RITRACKS; and Enabling Microliquid Chromatography by Microbead Packing of Microchannels.

Source record↗

Characterization of a Photon Counting Test Bed for Space to Ground Optical Pulse Position Modulation Communications Links

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has developed a laboratory transmitter and receiver prototype of a space to ground optical communications link. The system is meant to emulate future deep space optical communication links, such as the first crewed flight of Orion, in which the transmitted laser is modulated using pulse position modulation and the receiver is capable of detecting single photons. The transmitter prototype consists of a software defined radio, a high extinction ratio electro-optic modulator system, and 1550 nm laser. The receiver is a scalable concept and utilizes a single-pixel array of fiber coupled superconducting nanowire single photon detectors. The transmit and receive waveforms follow the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Standard. This paper describes the transmitter and receiver prototypes as well as the system test configuration. System level tests results are presented and compared to predictions from software simulations.

Nappier, Jennifer M.↗

Characterization of a Photon Counting Test Bed for Space to Ground Optical Pulse Position Modulation Communications Links

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has developed a laboratory transmitter and receiver prototype of a space-to-ground optical communications link. The system is meant to emulate future deep space optical communication links, such as the first crewed flight of Orion, in which the transmitted laser is modulated using pulse position modulation and the receiver is capable of detecting single photons. The transmitter prototype consists of a software defined radio, a high extinction ratio electro-optic modulator system, and a 1550 nm laser. The receiver is a scalable concept and utilizes a single-pixel array of fiber coupled superconducting nanowire single photon detectors. The transmit and receive waveforms follow the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Standard. A software model of the optical transmitter and receiver has also been implemented to predict performance of the optical test bed. This paper describes the transmitter and receiver prototypes as well as the system test configuration. System level tests results are presented and shown to align with predictions from software simulations. The validated software model can be used to in the future to reduce the design cycle of optical communications systems.

software defined radio↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Capacity and cutoff rate of (M+1)-ary decision rules for noisy M-ary optical PPM channel

The channel capacity C and the cutoff rate R sub o of two (M + 1)-ary decision rules for noisy M slots/symbol optical pulse position modulation (PPM) with ideal photon counting are computed and compared. Also the values of the optimum thresholds needed to minimize the signal requirements are given. With a minor increase in hardware complexity, the symbol by symbol threshold decision rule is shown to be superior to the slot by slot threshold detection and decision rule in two aspects: first, it saves more than 0.5 dB in signal energy for the very noisy cases of more than one noise photon per slot (for low noise cases it also saves signal energy, but a negligibly small amount). Second, it is more robust to variations in the noise level.

Lee, P. J.↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

Yan, Feng↗

Photon Detection with Cooled Avalanche Photodiodes: Theory and Preliminary Experimental Results

Avalanche photodiodes (APDs) can be operated in a geiger-tube mode so that they can respond to single electron events and thus be used as photon counting detectors. Operational characteristics and theory of APDs while used in this mode are analyzed and assessed. Preliminary experimental investigation of several commercially available APDs has commenced, and initial results for dark count statistics are presented.

Robinson, D. L.↗

Atmospheric emissions photometric imaging experiment /AEPT/ for Spacelab 1

The atmospheric emissions photometric imaging experiment (AEPI) to be flown on Spacelab 1 is designed to study faint natural and artificial atmospheric emission phenomena. Optical emissions are imaged in the region 2150 A to 7320 A using a television system consisting of two optical channels, one wide-angle and one telephoto. The detection system is an image-enhanced SEC vidicon. A third optical channel images onto the photocathode of a microchannel plate photomultiplier tube that has 100 discrete anodes. Photons are counted for each discrete anode, providing a direct measure of the luminosity of an object viewed by the TV telephoto lens, albeit with low spatial resolution. The AEPI detector is mounted on a two-axis gimbal comprised of a Modified Apollo Telescope Mount Star Tracker (MAST), which provides experiment pointing over a 40-deg x 80-deg range, exclusive of restrictions due to the proximity of other experiments. The pointing stability is 1 arcmin with respect to the spacecraft coordinate system for an exposure of 1 second. The tracking capability is 3.5 deg/s with a stability of 1 arcmin. The detector and pointing system are located on the Spacelab pallet. The experiment is controlled by stored programs resident in the Dedicated Experiment Processor located in the Spacelab module.

Sandie, W. G.↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

Parameter Estimation with Entangled Photons Produced by Parametric Down-Conversion

We explore the advantages offered by twin light beams produced in parametric down-conversion for precision measurement. The symmetry of these bipartite quantum states, even under losses, suggests that monitoring correlations between the divergent beams permits a high-precision inference of any symmetry-breaking effect, e.g., fiber birefringence. We show that the quantity of entanglement is not the key feature for such an instrument. In a lossless setting, scaling of precision at the ultimate "Heisenberg" limit is possible with photon counting alone. Even as photon losses approach 100% the precision is shot-noise limited, and we identify the crossover point between quantum and classical precision as a function of detected flux. The predicted hypersensitivity is demonstrated with a Bayesian simulation.

Cable, Hugo↗

Qualification of A Transition Edge Sensor Based Anti-Coincidence Detector for A Probe Class Mission

The Line Emission Mapper (or LEM) is an X-ray probe class mission aimed to study the physics of galaxy formation, with a large field-of-view, high-resolution transition-edge sensor (TES) microcalorimeter. Because of the diffuse and faint nature of LEM’s targets, a high-fidelity anticoincidence detector (anti-co) is essential to reduce instrument background below the level of sky background. Lying directly behind the LEM sensor, the anti-co will detect ~3 counts per second per square centimeter from background galactic cosmic rays and the secondary particles they induce to detect and flag any events that could be confused with a science photon in the 0.3-2 keV signal band of LEM. Our design spans an active region 4-cm in diameter. It consists of 12 quasiparticle-trap-assisted electrothermal-feedback (QET) channels, each with 100 parallel TESes with common bias lines. The TES is a narrow strip of Mo/Au bilayer. We present fabrication processes that maintain the transition temperature (T c ) in Mo/Au bilayer structures across the active region. We further present a new design based on a a-Si/W TES layer that has previously achieved reasonable uniformity in lab testing.

x-ray↗

Photon counting with a self-scanned diode array.

A self-scanned diode array may be used as temporary storage for individual photons if enough gain is provided by an image intensifier or electron multiplier to provide a detectable signal from each input event.

Mcnall, J. F.↗

Quantum Dots Microstructured Optical Fiber for X-Ray Detection

Microstructured optical fibers containing quantum dots scintillation material comprised of zinc sulfide nanocrystals doped with magnesium sulfide are presented. These quantum dots are applied inside the microstructured optical fibers using capillary action. The x-ray photon counts of these fibers are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The results of the fiber light output and associated effects of an acrylate coating and the quantum dot application technique are discussed.

DeHaven, Stan↗

Optical Communications Channel Combiner

NASA has identified deep-space optical communications links as an integral part of a unified space communication network in order to provide data rates in excess of 100 Mb/s. The distances and limited power inherent in a deep-space optical downlink necessitate the use of photon-counting detectors and a power-efficient modulation such as pulse position modulation (PPM). For the output of each photodetector, whether from a separate telescope or a portion of the detection area, a communication receiver estimates a log-likelihood ratio for each PPM slot. To realize the full effective aperture of these receivers, their outputs must be combined prior to information decoding. A channel combiner was developed to synchronize the log-likelihood ratio (LLR) sequences of multiple receivers, and then combines these into a single LLR sequence for information decoding. The channel combiner synchronizes the LLR sequences of up to three receivers and then combines these into a single LLR sequence for output. The channel combiner has three channel inputs, each of which takes as input a sequence of four-bit LLRs for each PPM slot in a codeword via a XAUI 10 Gb/s quad optical fiber interface. The cross-correlation between the channels LLR time series are calculated and used to synchronize the sequences prior to combining. The output of the channel combiner is a sequence of four-bit LLRs for each PPM slot in a codeword via a XAUI 10 Gb/s quad optical fiber interface. The unit is controlled through a 1 Gb/s Ethernet UDP/IP interface. A deep-space optical communication link has not yet been demonstrated. This ground-station channel combiner was developed to demonstrate this capability and is unique in its ability to process such a signal.

Quirk, Kevin J.↗

Superconducting nanowires as high-rate photon detectors in strong magnetic fields

Superconducting nanowire single photon detectors are capable of single-photon detection across a large spectral range, with near unity detection efficiency, picosecond timing jitter, and sub-10 µm position resolution at rates as high as 10 9 counts/s. In an effort to bring this technology into nuclear physics experiments, we fabricate Niobium Nitride nanowire detectors using novel material preparation methods and test their performance in strong magnetic fields. Furthermore, we demonstrate that these devices are capable of detection of 400 nm wavelength photons with saturated internal quantum efficiency at liquid helium temperatures and in magnetic fields potentially up to 8 T at high rates and with nearly zero dark counts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Rydberg Xenon Submillimeter-Wave Detector

Proposed detector for infrared and submillimeter-wavelength radiation uses excited xenon atoms as Rydberg sensors instead of customary beams of sodium, potassium, or cesium. Chemically inert xenon easily stored in pressurized containers, whereas beams of dangerously reactive alkali metals must be generated in cumbersome, unreliable ovens. Xenon-based detector potential for infrared astronomy and for Earth-orbiter detection of terrestrial radiation sources. Xenon atoms excited to high energy states in two stages. Doubly excited atoms sensitive to photons in submillimeter wavelength range, further excited by these photons, then ionized and counted.

Chutjian, Ara↗