Search NASA⌕ Search

SEARCH · Search NASA

Results for “physiological stress”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A GEO Hyperspectral Mission For Continental-Scale Carbon Cycle Observations

For both terrestrial and ocean carbon cycle science objectives, a hyperspectral geostationary sensor should enable the development of new remote sensing measurements for important but as yet unobservable variables, and with the overall goal of linking both terrestrial and ocean carbon cycle processes to climate variability. For terrestrial research, accurate estimates of carbon, water and energy (CWE) exchange between the terrestrial biosphere and atmosphere are needed to identify the geographical locations of carbon sources/sinks and to improve regional climate models and global climate change assessments. It is an enormous challenge to estimate CWE exchange from the infrequent temporal coverage provided by most polar-orbiting satellites, and without benefit of spectral indices that capture vegetation responses to stress conditions that down-regulate photosynthesis. Physiological status can be better assessed with spectral indices based on continuous, narrow (5 nm) bands, as can seasonal and annual terrestrial productivity. For coastal and ocean constituents, narrow-band observations in the ultraviolet and visible are essential to investigate the variability, dynamics and biogeochemical cycles of the world s coastal and open ocean regions, which will in turn help in measuring ocean productivity and predicting the variability of Ocean carbon uptake and its role in climate change scenarios. The GSFC Carbon Team has been pursuing a geostationary hyperspectral instrument, which would revolutionize our knowledge of biological processes on land, in the ocean, and along the coast by providing multiple, diurnal coverage. Preliminary studies in Goddard's Instrument Synthesis and Analysis Laboratory (ISAL) indicate that we can meet many of our science requirements: full spectral coverage (360-1000 nm); narrow bandwidths (5-10 nm); adequate ground resolution (100-200 m); and continental-scale coverage 4-6 times per day; all the while achieving a signal to noise ratio of between 500 and 1000 to 1. However, an innovative and bold focal plane design and a large mirror (1.8 meter diameter) would be required. The development of our science requirements and the results of the initial design study will be presented as well as our most recent technological developments.

Gervin, Janette C.↗

Acridine orange staining reaction as an index of physiological activity in Escherichia coli

The assumption that the acridine orange (AO) color reaction may be used as an index of physiological activity was investigated in laboratory grown Escherichia coli. Spectrofluorometric observations of purified nucleic acids, ribosomes and the microscopic color of bacteriophage-infected cells stained with AO confirmed the theory that single-stranded nucleic acids emit orange to red fluorescence while those that are double-stranded fluoresce green in vivo. Bacteria growing actively in a rich medium could be distinguished from cells in stationary phase by the AO reaction. Cells from log phase appeared red, whereas those in stationary phase were green. However, this differentiation was not seen when the bacteria were grown in a minimal medium or when a variation of the staining method was used. Also, shifting bacteria in stationary phase to starvation conditions rapidly changed their AO staining reaction. Boiling and exposure to lethal concentrations of azide and formalin resulted in stationary-phase cells that appeared red after staining but bacteria killed with chlorine remained green. These findings indicate that the AO staining reaction may be suggestive of physiological activity under defined conditions. However, variables in staining and fixation procedures as well as uncertainties associated with mixed bacterial populations in environmental samples may produce results that are not consistent with the classical interpretation of this reaction. The importance of validating the putative physiological implications of this staining reaction is stressed.

NASA Discipline Number 04-10↗

Cardiovascular responses to repetitive exposure to hyper- and hypogravity states produced by parabolic flight

Physiologic changes to repetitive hyper- and hypogravity stresses occurring during eight to ten parabolas on NASA's KC-135 aircraft were studied. Hemodynamic responses in 11 subjects in 4 different postures (supine, standing, sitting, and semisupine Space Shuttle launch position) were determined using noninvasive impedance cardiography. Five seconds of heart rate, cardiac index, thoracic fluid index, stroke index, ejection velocity index, and ventricular ejection time data were averaged during four different gravity (g) states: 1.3g (before parabola onset); 1.9g (parabola entry); 0g (parabola peak); and 1.7g (parabola exit) for each subject. The standing position was associated with the largest changes in the cardiovascular response to hypo- and hypergravity. The thoracic fluid index did not indicate a headward redistribution during transition from a simulated launch position to weightlessness. Analysis of the eight to ten parabolas revealed that, in general, values obtained at 1.8g differed from 1.6g, 0g differed from 1.6 and 1.3g, and 1.6g differed from 1.3g. The factors of gravity, thoracic fluid index, and cardiac index exhibited significant differences that were most likely to occur between parabola 1 versus parabolas 6, 7, and 8, and parabola 2 versus parabolas 4 through 8. Only the parameter of thoracic fluid index exhibited significance for parabolas 3 versus parabolas 6 and 7.

Space Flight↗

Inflight Pharmacokinetic and Pharmacodynamic Responses to Medications Commonly Used in Spaceflight

Researchers do not know if medications act the same in the spaceflight environment as they do on Earth. Aspects of the spaceflight environment (low gravity, radiation exposure, closed environment, stress) have been shown to alter human physiology. Some of these physiological changes could be expected to alter either pharmacokinetics (PK, how the body absorbs, distributes, metabolizes and excretes administered medications) or pharmacodynamics (PD, receptors or signaling systems that are the targets of medication action). Anecdotal data has suggested that, at least for certain medications or indications, inflight medication efficacy is poor. In order to prepare for exploration missions where speedy evacuation to Earth may not be a possibility, the likelihood of unexpected medication action must be determined.

Wotring, V. E.↗

Psychosocial correlates of immune responsiveness and illness episodes in US Air Force Academy cadets undergoing basic cadet training

This study examined psychosocial correlates of immune function and illness in 89 male first-year US Air Force Academy cadets. A psychosocial questionnaire was administered to cadets prior to their arrival at the academy and was readministered during cadet orientation and during the stressful environment of Basic Cadet Training (BCT). Immune responsiveness was analyzed by PHA-, PMA-, or anti-CD3-stimulated thymidine uptake in mononuclear leucocytes. Illness episodes were assessed via medical chart review and self-reported symptoms. There were significant increases in distress levels as cadets entered BCT. No psychosocial measure assessed prior to arrival at the academy predicted level of PHA-, PMA-, and anti-CD3-stimulated thymidine uptake or risk of illness. However, hostility levels reported during BCT predicted risk of illness in the four weeks following psychosocial assessment (odds ratio = 7.1; 95% confidence interval: 1.4-36.1). Elevated response to environmental stressors and lower well-being levels also predicted impending illness, but only in the cohort of cadets who had not contracted food poisoning prior to assessment during BCT (OR = 9.3, CI = 1.9-46.7; OR = 0.09, CI = 0.02-0.53). These results suggest that self-report measures of hostility, response to environmental stressors and well-being may be useful predictors of impending illness episodes in males encountering high stress environments.

NASA Discipline Regulatory Physiology↗

Human Physiological Responses to Acute and Chronic Cold Exposure

When inadequately protected humans are exposed to acute cold, excessive body heat is lost to the environment and unless heat production is increased and heat loss attenuated, body temperature will decrease. The primary physiological responses to counter the reduction in body temperature include marked cutaneous vasoconstriction and increased metabolism. These responses, and the hazards associated with such exposure, are mediated by a number of factors which contribute to heat production and loss. These include the severity and duration of the cold stimulus; exercise intensity; the magnitude of the metabolic response; and individual characteristics such as body composition, age, and gender. Chronic exposure to a cold environment, both natural and artificial, results in physiological alterations leading to adaptation. Three quite different, but not necessarily exclusive, patterns of human cold adaptation have been reported: metabolic, hypothermic, and insulative. Cold adaptation has also been associated with an habituation response, in which there is a desensitization, or damping, of the normal response to a cold stress. This review provides a comprehensive analysis of the human physiological and pathological responses to cold exposure. Particular attention is directed to the factors contributing to heat production and heat loss during acute cold stress, and the ability of humans to adapt to cold environments.

Stocks, Jodie M.↗

Temperature

The problems in human comfort in heat stress are emphasized, with less emphasis placed upon cold exposure problems. Physiological parameters related to human thermal interactions are discussed, as well as data concerning thermal protective clothing. The energy balance equation, heat transfer equation, thermal comfort, heat stress, and cold stress are also considered. A two node model of human temperature regulation in FORTRAN is appended.

Berenson, P. J.↗

Early remote laser detection of vegetation damage caused by certain environmental stress factors

The fluorescence spectra of plants excited with a pulsed nitrogen laser beam emitting at 337 nm were found to be related to plant type, as well as with changes in the physiology of the plant as the result of various kinds of environmental stress. The plant types which were studied included herbaceous dicots, monocots, hardwoods, and conifers. These plant types could be identified on the basis of differences in either the number of fluorescent bands, or the relative intensity of the bands. The dicots and monocots had fluorescent maxima at 440, 685, and 740 nm. The monocots could be distinguished from the dicots by virtue of having a much higher 440 nm/685 nm ratio. Hardwoods and conifers had an additional fluorescence band at 525 nm, but healthy conifers did not have a band at 685 nm.

Chappelle, Emmett W.↗

Physiological response in pilot/back-seat man during aerial combat maneuvers in F-4E aircraft.

Comparison of objective/subjective physiological data between the pilot and the back-seat man during training within the G maneuvering envelope. It appears that the psychological requirements for the pilot to be mentally alert and physiologically adapted to a continually changing environment places additional responsibility on him to the extent the physiological signs monitored are indicative of a high stress condition and are increased by a significant amount over the back-seat man who is, in most instances, riding passively.

Leverett, S. D., Jr.↗

Laser-Induced Fluorescence (LIF) from plant foliage

The fluorescence spectra and fluorescence induction kinetics of green plants excited at 337 nm by a laser were studied. They correlate with plant type, as well as with changes in the physiology of the plant as the result of stress. The plant types studied include herbaceous dicots, monocots, hardwoods, conifers, and algae. These plant types could be identified on the basis of differences in either the number of fluorescent bands or the relative intensity of the bands. Differences in fluorescent spectra which could be related to vigor status are observed in conifers located in an area of high atmospheric deposition. Changes in the fluorescence spectra and induction kinetics are also seen in plants grown under conditions of nutrient deficiency and drought stress.

Chappelle, E. W.↗

Laser-Induced Fluorescence (LIF) from plant foliage

The fluorescence spectra and fluorescence induction kinetics of green plants excited at 337 nm by a laser were studied. They correlate with plant type, as well as with changes in the physiology of the plant as the result of stress. The plant types studied include herbaceous dicots, monocots, hardwoods, conifers, and algae. These plant types could be identified on the basis of differences in either the number of fluorescent bands or the relative intensity of the bands. Differences in fluorescent spectra which could be related to vigor status are observed in conifers located in an area of high atmospheric deposition. Changes in the fluorescence spectra and induction kinetics are also seen in plants grown under conditions of nutrient deficiency and drought stress.

Chappelle, Emmett W.↗

NASA Space Technology Can Improve Soldier Health, Performance and Safety

One of the primary goals of NASA Life Sciences research is '... to enable a permanent human presence in space.' To meet this goal, NASA is creating alternative protocols designed to evaluate and test countermeasures that will account for and correct the environmental effects of space flight on crewmembers health, safety, and operational performance. NASA investigators have previously evaluated the effects of long-duration space flight on physiology and performance of cosmonauts aboard the MIR space station. They also initiated tests of a countermeasure, Autogenic-Feedback Training Exercise (AFTE) designed to prevent and/or correct adverse effects, i.e., facilitate adaptation to space and re-adaptation to Earth. AFTE is a six-hour physiological training program that has proven to be a highly efficient and effective method for enabling people to monitor and voluntarily control a range of their own physiological responses, thereby minimizing adverse reactions to environmental stress. However, because of limited opportunities to test this technology with space flight crews, it is essential to find operational or 'real world' environments in which to validate the efficacy of this approach.

Cowings, Patricia S.↗

Hemodynamic Responses to Head and Neck Cooling

Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗