Search NASA⌕ Search

SEARCH · Search NASA

Results for “physiological temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

To develop a spectral analyzer for physiological and medical use

Scientific requirements necessary to develop a spectral analyzer for monitoring mammalian subjects, are discussed. The analyzer measures dynamic or time dependent data as a measure of the subjects operating status. Measurable data include metabolic rate, body temperature, and blood constituents like glucose, oxygen, and carbon dioxide, and lactic acid. Metabolic cycles were found with periodicities in the range of minutes and hours; longer cycles in body weight (3 1/2 days and 60 days), indicative of metabolic processes, were also found.

Iberall, A.↗

A multiparameter wearable physiologic monitoring system for space and terrestrial applications

A novel, unobtrusive and wearable, multiparameter ambulatory physiologic monitoring system for space and terrestrial applications, termed LifeGuard, is presented. The core element is a wearable monitor, the crew physiologic observation device (CPOD), that provides the capability to continuously record two standard electrocardiogram leads, respiration rate via impedance plethysmography, heart rate, hemoglobin oxygen saturation, ambient or body temperature, three axes of acceleration, and blood pressure. These parameters can be digitally recorded with high fidelity over a 9-h period with precise time stamps and user-defined event markers. Data can be continuously streamed to a base station using a built-in Bluetooth RF link or stored in 32 MB of on-board flash memory and downloaded to a personal computer using a serial port. The device is powered by two AAA batteries. The design, laboratory, and field testing of the wearable monitors are described.

NASA Center ARC↗

Circadian rhythms in human performance and mood under constant conditions

This study explored the relationship between circadian performance rhythms and rhythms in rectal temperature, plasma cortisol, plasma melatonin, subjective alertness and well-being. Seventeen healthy young adults were studied under 36 h of 'unmasking' conditions (constant wakeful bedrest, temporal isolation, homogenized 'meals') during which rectal temperatures were measured every minute, and plasma cortisol and plasma melatonin measured every 20 min. Hourly subjective ratings of global vigour (alertness) and affect (well-being) were obtained followed by one of two performance batteries. On odd-numbered hours performance (speed and accuracy) of serial search, verbal reasoning and manual dexterity tasks was assessed. On even-numbered hours, performance (% hits, response speed) was measured at a 25-30 min visual vigilance task. Performance of all tasks (except search accuracy) showed a significant time of day variation usually with a nocturnal trough close to the trough in rectal temperature. Performance rhythms appeared not to reliably differ with working memory load. Within subjects, predominantly positive correlations emerged between good performance and higher temperatures and better subjective alertness; predominantly negative correlations between good performance and higher plasma levels of cortisol and melatonin. Temperature and cortisol rhythms correlated with slightly more performance measures (5/7) than did melatonin rhythms (4/7). Global vigour correlated about as well with performance (5/7) as did temperature, and considerably better than global affect (1/7). In conclusion: (1) between-task heterogeneity in circadian performance rhythms appeared to be absent when the sleep/wake cycle was suspended; (2) temperature (positively), cortisol and melatonin (negatively) appeared equally good as circadian correlates of performance, and (3) subjective alertness correlated with performance rhythms as well as (but not better than) body temperature, suggesting that performance rhythms were not directly mediated by rhythms in subjective alertness.

NASA Discipline Regulatory Physiology↗

Biotelemetry

Sensors 2000! is developing pill-shaped biotelemeters for measuring physiological parameters during space flight life sciences experiments using rodents aboard the ISS Gravitational Biology Facility, with the additional capability for monitoring the health of astronauts in the Human Research Facility. The first "pill transmitter" is capable of measuring pressure and temperature for up to 10 months. The NASA objective is to utilize these devices. The pill-transmitters can also be used by non-NASA users for medical applications. One application is fetal surgery. The 44pill" is small enough to be endoscopically placed into the womb through a tube used during surgeries to correct fetal defects before birth. After surgery, the pill-transmitter will continue to monitor body temperature, pressure and other vital signs in the womb, radioing results to physicians. It will help them to detect preterm-labor, a serious problem after fetal surgery. The pill is about one-third-of-an-inch across and one-and-one-third-inches long. Future pill-versions will include pH, heartrate, and ECG. A pH-pill prototype is currently being tested. Sensors 2000! has also designed and built a 2-channel biotelemetry receiver and has developed data acquisition software to display and record the measured physiological parameters. A DSP-base hand-held receiver (trisponder) is currently under development.

Mundt, C.↗

Decomposition of Alternative Chirality Amino Acids by Alkaliphilic Anaerobe from Owens Lake, California

The study of alkaliphilic microbial communities from anaerobic sediments of Owens and Mono Lakes in California led to the isolation of a bacterial strain capable of metabolizing amino acids with alternative chirality. According to the phylogenetic analysis, the anaerobic strain BK1 belongs to the genus Tindallia; however, despite the characteristics of other described species of this genus, the strain BK1 was able to grow on D-arginine and Dlysine. Cell morphology of this strain showed straight, motile, non-spore-forming rods with sizes 0.45 x 1.2-3 microns. Physiological characteristics of the strain showed that it is catalase negative, obligately anaerobic, mesophilic, and obligately alkaliphilic. This isolate is unable to grow at pH 7 and requires CO3 (2-) ions for growth. The strain has chemo-heterotrophic metabolism and is able to ferment various proteolysis products and some sugars. It plays the role of a primary anaerobe within the trophic chain of an anaerobic microbial community by the degradation of complex protein molecules to smaller and less energetic molecules. The new isolate requires NaCl for growth, and can grow within the range of 0.5-13 %, with the optimum at 1 % NaCl (w/v). The temperature range for the growth of the new isolate is 12-40 C with optimum at 35 C. The pH range for the growth of strain BK1 occurs between 7.8 and 11.0 with optimum at 9.5. This paper presents detailed physiological characteristics of the novel isolate from Owens Lake, a unique relic ecosystem of Astrobiological significance, and makes an accent on the ability of this strain to utilize L-amino acids.

Townsend, Alisa↗

Directed evolution of an RNA enzyme

An in vitro evolution procedures was used to obtain RNA enzymes with a particular catalytic function. A population of 10 exp 13 variants of the Tetrahymena ribozyme, a group I ribozyme that catalyzes sequence-specific cleavage of RNA via a phosphoester transfer mechanism, was generated. This enzyme has a limited ability to cleave DNA under conditions of high temperature or high MgCl2 concentration, or both. A selection constraint was imposed on the population of ribozyme variants such that only those individuals that carried out DNA cleavage under physiologic conditions were amplified to produce 'progeny' ribozymes. Mutations were introduced during amplification to maintain heterogeneity in the population. This process was repeated for ten successive generations, resulting in enhanced (100 times) DNA cleavage activity.

Beaudry, Amber A.↗

Viking GCMS Data Restoral and Perceiving Temperature on Other Worlds: Astrobiology Projects at NASA Ames

The primary task for the summer was to procure the GCMS data from the National Space Science Data Coordinated Archive (NSSDCA) and to assess the current state of the data set for possible reanalysis opportunities. After procurement of the Viking GCMS data set and analysis of its current state, the internship focus shifted to preparing a plan for restoral and archiving of the GCMS data set. A proposal was prepared and submitted to NASA Headquarters to restore and make available the 8000 mass chromatographs that are the basic data generated by the Viking GCMS instrument. The relevance of this restoral and the methodology we propose for restoral is presented. The secondary task for the summer is to develop a thermal model for the perceived temperature of a human standing on Mars, Titan, or Europa. Traditionally, an equation called "Fanger's comfort equation" is used to measure the perceived temperature by a human in a given reference environment. However, there are limitations to this model when applied to other planets. Therefore, the approach for this project has been to derive energy balance equations from first principles and then develop a methodology for correlating "comfort" to energy balance. Using the -20 C walk-in freezer in the Space Sciences building at NASA Ames, energy loss of a human subject is measured. Energy loss for a human being on Mars, Titan and Europa are calculated from first principles. These calculations are compared to the freezer measurements, e.g. for 1 minute on Titan, a human loses as much energy as x minutes in a -20 C freezer. This gives a numerical comparison between the environments. These energy calculations are used to consider the physiological comfort of a human based on the calculated energy losses.

FangeraEuro(TM)s comfort equation↗

Metabolic and cardiovascular adaptation, monkey. NASA SMD 3, project 76, experiment 44 conducted at NASA/JSC, 14-25 May 1977

The biomedical results from an experiment on a monkey subjected to space flight conditions are reported. A background history of the development and testing of an experiment system designed to permit measurement of physiological parameters in subhuman primates during continuous, comfortable, couch restraint for periods of up to 30 days is reviewed. Of major importance in the experimental design of the system was the use of a fiberglass pod, which could be sealed and subdivided into upper and lower parts, to monitor and control the physiological responses for various parts of the animal's body. The experiment was conducted within the Spacelab Simulator for a period of 11 days. Data recorded includes: Spacelab Simulator cabin temperature; ventilation rate; pod internal temperature; fraction percent oxygen; fraction percent carbon dioxide; oxygen consumption rate; carbon dioxide production rate; respiratory quotient; intrathoracic temperature; heart rate; mean aortic pressure; mean ventricular pressure; diurnal variation of parameters measured; comparison of mean preflight, flight, and postflight values of the parameters measured; and correlation matrix for the parameters measured.

Pace, N.↗

Countermeasures to Neurobehavioral Deficits from Cumulative Partial Sleep Deprivation During Space Flight

This project is concerned with identifying ways to prevent neurobehavioral and physical deterioration due to inadequate sleep in astronauts during long-duration manned space flight. The performance capability of astronauts during extended-duration space flight depends heavily on achieving recovery through adequate sleep. Even with appropriate circadian alignment, sleep loss can erode fundamental elements of human performance capability including vigilance, cognitive speed and accuracy, working memory, reaction time, and physiological alertness. Adequate sleep is essential during manned space flight not only to ensure high levels of safe and effective human performance, but also as a basic regulatory biology critical to healthy human functioning. There is now extensive objective evidence that astronaut sleep is frequently restricted in space flight to averages between 4 hr and 6.5 hr/day. Chronic sleep restriction during manned space flight can occur in response to endogenous disturbances of sleep (motion sickness, stress, circadian rhythms), environmental disruptions of sleep (noise, temperature, light), and curtailment of sleep due to the work demands and other activities that accompany extended space flight operations. The mechanism through which this risk emerges is the development of cumulative homeostatic pressure for sleep across consecutive days of inadequate sleep. Research has shown that the physiological sleepiness and performance deficits engendered by sleep debt can progressively worsen (i.e., accumulate) over consecutive days of sleep restriction, and that sleep limited to levels commonly experienced by astronauts (i.e., 4 - 6 hr per night) for as little as 1 week, can result in increased lapses of attention, degradation of response times, deficits in complex problem solving, reduced learning, mood disturbance, disruption of essential neuroendocrine, metabolic, and neuroimmune responses, and in some vulnerable persons, the emergence of uncontrolled sleep attacks. The prevention of cumulative performance deficits and neuroendocrine disruption from sleep restriction during extended duration space flight involves finding the most effective ways to obtain sleep in order to maintain the high-level cognitive and physical performance functions required for manned space flight. There is currently a critical deficiency in knowledge of the effects of how variations in sleep duration and timing relate to the most efficient return of performance per unit time invested in sleep during long-duration missions, and how the nature of sleep physiology (i.e., sleep stages, sleep electroencephalographic [EEG] power spectral analyses) change as a function of sleep restriction and performance degradation. The primary aim of this project is to meet these critical deficiencies through utilization of a response surface experimental paradigm, testing in a dose-response manner, varying combinations of sleep duration and timing, for the purpose of establishing how to most effectively limit the cumulative adverse effects on human performance and physiology of chronic sleep restriction in space operations.

Dinges, David F.↗

Stability, precision, and near-24-hour period of the human circadian pacemaker

Regulation of circadian period in humans was thought to differ from that of other species, with the period of the activity rhythm reported to range from 13 to 65 hours (median 25.2 hours) and the period of the body temperature rhythm reported to average 25 hours in adulthood, and to shorten with age. However, those observations were based on studies of humans exposed to light levels sufficient to confound circadian period estimation. Precise estimation of the periods of the endogenous circadian rhythms of melatonin, core body temperature, and cortisol in healthy young and older individuals living in carefully controlled lighting conditions has now revealed that the intrinsic period of the human circadian pacemaker averages 24.18 hours in both age groups, with a tight distribution consistent with other species. These findings have important implications for understanding the pathophysiology of disrupted sleep in older people.

NASA Discipline Regulatory Physiology↗

Effect of prolonged hypodynamia on certain physiological functions in dogs

The behavior of 20 dogs whose mobility was restricted was experimentally investigated. Their reactions to hypodynamia were either active behavior or progressive general depression and increased muscular weakness. Arterial pressure, pressor sinocarotid reflex valve, body weight, pulse rate, body temperature, and plasma cholinesterase activity were monitered for 28 days. Results are reported.

Yaremenko, B. R.↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling↗

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit↗

Regularity of daily life in relation to personality, age, gender, sleep quality and circadian rhythms

A diary-like instrument to measure lifestyle regularity (the 'Social Rhythm Metric'-SRM) was given to 96 subjects (48 women, 48 men), 39 of whom repeated the study after at least one year, with additional objective measures of rest/activity. Lifestyle regularity as measured by the SRM related to age, morningness, subjective sleep quality and time-of-day variations in alertness, but not to gender, extroversion or neuroticism. Statistically significant test-retest correlations of about 0.4 emerged for SRM scores over the 12-30 month delay. Diary-based estimates of bedtime and waketime appeared fairly reliable. In a further study of healthy young men, 4 high SRM scorers ('regular') had a deeper nocturnal body temperature trough than 5 low SRM scorers ('irregular'), suggesting a better functioning circadian system in the 'regular' group.

NASA Discipline Regulatory Physiology↗

Effect of inducing nocturnal serum melatonin concentrations in daytime on sleep, mood, body temperature, and performance

We examined effects of very low doses of melatonin (0.1-10 mg, orally) or placebo, administered at 1145 h, on sleep latency and duration, mood, performance, oral temperature, and changes in serum melatonin levels in 20 healthy male volunteers. A repeated-measure double-blind Latin square design was used. Subjects completed a battery of tests designed to assess mood and performance between 0930 and 1730 h. The sedative-like effects of melatonin were assessed by a simple sleep test: at 1330 h subjects were asked to hold a positive pressure switch in each hand and to relax with eyes closed while reclining in a quiet darkened room. Latency and duration of switch release, indicators of sleep, were measured. Areas under the time-melatonin concentration curve varied in proportion to the different melatonin doses ingested, and the 0.1- and 0.3-mg doses generated peak serum melatonin levels that were within the normal range of nocturnal melatonin levels in untreated people. All melatonin doses tested significantly increased sleep duration, as well as self-reported sleepiness and fatigue, relative to placebo. Moreover, all of the doses significantly decreased sleep-onset latency, oral temperature, and the number of correct responses on the Wilkinson auditory vigilance task. These data indicate that orally administered melatonin can be a highly potent hypnotic agent; they also suggest that the physiological increase in serum melatonin levels, which occurs around 2100 h daily, may constitute a signal initiating normal sleep onset.

Non-NASA Center↗

Siderophilic Cyanobacteria: Implications for Early Earth.

Of all extant environs, iron-depositing hot springs (IDHS) may exhibit the greatest similarity to late Precambrian shallow warm oceans in regards to temperature, O2 gradients and dissolved iron and H2S concentrations. Despite the insights into the ecology, evolutionary biology, paleogeobiochemistry, and astrobiology examination of IDHS could potentially provide, very few studies dedicated to the physiology and diversity of cyanobacteria (CB) inhabiting IDHS have been conducted. Results. Here we describe the phylogeny, physiology, ultrastructure and biogeochemical activity of several recent CB isolates from two different greater Yellowstone area IDHS, LaDuke and Chocolate Pots. Phylogenetic analysis of 16S rRNA genes indicated that 6 of 12 new isolates examined couldn't be placed within established CB genera. Some of the isolates exhibited pronounced requirements for elevated iron concentrations, with maximum growth rates observed when 0.4-1 mM Fe(3+) was present in the media. In light of "typical" CB iron requirements, our results indicate that elevated iron likely represents a salient factor selecting for "siderophilicM CB species in IDHS. A universal feature of our new isolates is their ability to produce thick EPS layers in which iron accumulates resulting in the generation of well preserved signatures. In parallel, siderophilic CB show enhanced ability to etch the analogs of iron-rich lunar regolith minerals and impact glasses. Despite that iron deposition by CB is not well understood mechanistically, we recently obtained evidence that the PS I:PS II ratio is higher in one of our isolates than for other CB. Although still preliminary, this finding is in direct support of the Y. Cohen hypothesis that PSI can directly oxidize Fe(2+). Conclusion. Our results may have implications for factors driving CB evolutionary relationships and biogeochemical processes on early Earth and probably Mars.

Brown, I. I.↗

Circadian periodicity of resistance to ionizing radiation in the pocket mouse.

Investigation of the response of pocket mice to Co 60 irradiation delivered at two times of day - namely, the predicted high and low points of the metabolic rate. The validity of torpor as an assay of the circadian period of body temperature in pocket mice and as a basis for selecting irradiation times is examined. A study is made of the mitotic activity in the pocket mouse intestinal epithelium as an example of a physiological rhythm which might influence radiation sensitivity. The results of tests in which pocket mice were exposed to ionizing radiation at two different times of day are cited. It is found that under the investigated conditions pocket mice irradiated during their metabolically active period (2330 hr) live significantly longer than those irradiated while their metabolic rate is low (0900 hr).

Lindberg, R. G.↗