Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Performance Analysis of Transposition Models Simulating Solar Radiation on Inclined Surfaces: Preprint

Transposition models are widely used in the solar energy industry to simulate solar radiation on inclined photovoltaic (PV) panels. These transposition models have been developed using various assumptions about the distribution of the diffuse radiation, and most of the parameterizations in these models have been developed using hourly ground data sets. Numerous studies have compared the performance of transposition models, but this paper aims to understand the quantitative uncertainty in the state-of-the-art transposition models and the sources leading to the uncertainty using high-resolution ground measurements in the plane of array. Our results suggest that the amount of aerosol optical depth can affect the accuracy of isotropic models. The choice of empirical coefficients and the use of decomposition models can both result in uncertainty in the output from the transposition models. It is expected that the results of this study will ultimately lead to improvements of the parameterizations as well as the development of improved physical models.

14 SOLAR ENERGY↗

Comparison of Pyranometers and Reference Cells on Fixed and One-Axis Tracking Surfaces: Preprint

A wide variety of sensors are used to monitor the irradiance incident on solar modules to evaluate the performance of photovoltaic (PV) systems. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules, a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles of incidence, even though both instruments are based on measuring the short-circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded-base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer, which has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Assessment of Error Sources in the Modeling of POA Irradiance Under Clear-Sky Conditions: Preprint

A new physics-based model, the Fast All-sky Radiation Model for Solar applications with Narrowband Irradiances on Tilted surfaces (FARMS-NIT), accurately computes plane-of-array (POA) irradiances in both narrow- and broad wavelength bands within the solar region. The evaluation studies suggest that the new model provides increased accuracy than a model assuming isotropic diffuse solar radiation and an empirical model linking the POA irradiances with long-term surface observations at selected locations. This study anlyzes the surface observations used by FARMS-NIT and is intended to understand the error sources under clear-sky conditions as well as their impact to the performance of FARMS-NIT.

14 SOLAR ENERGY↗

Evaluation of the PV Resource Dataset in Central and North America: Preprint

A recent effort from the National Renewable Energy Laboratory (NREL) has led to a new radiative transfer model, Fast All-sky Radiation Model for Solar applications with Narrowband Irradiances on Tilted surfaces (FARMS-NIT), to efficiently compute plane-of-array (POA) irradiance. This model has been implemented by the National Solar Radiation Data Base (NSRDB) to provide photovoltaic (PV) resource over Central and North America in both narrow- and broad wavelength bands. This study conducts a comprehensive evaluation of the PV resource dataset using surface-based observations in various climate zones. The results demonstrate the PV resource has an excellent agreement with the cloudy-sky observations from thermopiles and reference cells.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Comparison of Predictive Models for PV Module Performance (Presentation)

This paper examines three models used to estimate the maximum power (P{sub m}) of PV modules when the irradiance and PV cell temperature are known: (1) the power temperature coefficient model, (2) the PVFORM model, and (3) the bilinear interpolation model. A variation of the power temperature coefficient model is also presented that improved model accuracy. For modeling values of P{sub m}, an 'effective' plane-of-array (POA) irradiance (E{sub e}) and the PV cell temperature (T) are used as model inputs. Using E{sub e} essentially removes the effects of variations in solar spectrum and reflectance losses, and permits the influence of irradiance and temperature on model performance for P{sub m} to be more easily studied. Eq. 1 is used to determine E{sub e} from T and the PV module's measured short-circuit current (I{sub sc}). Zero subscripts denote performance at Standard Reporting Conditions (SRC).

14 SOLAR ENERGY↗

Phase- and group-matched nonlinear interactions mediated by multiple filamentation in Kerr media

Laser-pulse filamentation in Kerr media induced by a strongly elliptic input beam leads to breakup into a periodic array of filaments. In the plane of the filament array we observe strong Stokes and anti-Stokes emission at large angles. For 1 ps input pulses the measured angles are found to support two different phase-matching configurations: one nontransversally phase matched and the other perfectly phase matched. Shorter 200 fs pulses give rise to group-velocity-matched Raman conversion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sharp and Tunable Crystal/Fano-Type Resonances Enabled by Out-of-Plane Dipolar Coupling in Plasmonic Nanopatch Arrays

Tuning resonance lineshapes of plasmonic structures is essential to create customized media with compelling optical properties for optimized light–matter interactions. The diversity of available metals and the variety of design architectures provide a rich portfolio for statically controlling the resonance lineshape. However, dynamic tuning of resonance attributes (e.g., the resonance wavelength and linewidth) are yet to be more expanded, especially when a narrow resonance linewidth is on demand. Here, using a plasmonic nanopatch array, sharp plasmonic crystal (PC) resonances are demonstrated across a wide spectral range of 230 nm, with full-width at half-maximum of only ≈6 nm. The combination of angle-resolved ellipsometry and full-wave simulations shows that diffractive coupling of out-of-plane electric dipoles is the principal contributor in the formation of such sharp PC resonances. In addition, the designed nanopatch PC supports a plasmonic Fabry–Pérot-like resonance that can be interfered with the PC resonance to generate complex Fano-type lineshapes. Finally, the coexistence of tunable resonance features renders the designed structures as a rich platform for applications seeking enhanced light–matter interactions and optical signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrical and structural properties of ZnO synthesized via infiltration of lithographically defined polymer templates

We investigate the electrical and structural properties of infiltration-synthesized ZnO. In-plane ZnO nanowire arrays with prescribed positional registrations are generated by infiltrating diethlyzinc and water vapor into lithographically defined SU-8 polymer templates and removing organic matrix by oxygen plasma ashing. Transmission electron microscopy reveals that homogeneously amorphous as-infiltrated polymer templates transform into highly nanocrystalline ZnO upon removal of organic matrix. Field-effect transistor device measurements show that the synthesized ZnO after thermal annealing displays a typical n-type behavior, ~1019 cm -3 carrier density, and ~0.1 cm 2 V -1 s -1 electron mobility, reflecting highly nanocrystalline internal structure. The results demonstrate the potential application of infiltration synthesis in fabricating metal oxide electronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic antenna excitation of whistler modes. IV. Receiving antennas and reciprocity

Antenna radiation patterns are an important property of antennas. Reciprocity holds in free space and the radiation patterns for exciting and receiving antennas are the same. In anisotropic plasmas, radiation patterns are complicated by the fact that group and phase velocities differ and certain wave properties like helicity depend on the direction of wave propagation with respect to the background magnetic field B{sub 0}. Interference and wave focusing effects are different than in free space. Reciprocity does not necessarily hold in a magnetized plasma. The present work considers the properties of various magnetic antennas used for receiving whistler modes. It is based on experimental data from exciting low frequency whistler modes in a large uniform laboratory plasma. By superposition of linear waves from different antennas, the radiation patterns of antenna arrays are derived. Plane waves are generated and used to determine receiving radiation patterns of different receiving antennas. Antenna arrays have radiation patterns with narrow lobes, whose angular position can be varied by physical rotation or electronic phase shifting. Reciprocity applies to broadside antenna arrays but not to end fire arrays which can have asymmetric lobes with respect to B{sub 0}. The effect of a relative motion between an antenna and the plasma has been modeled by the propagation of a short wave packet moving along a linear antenna array. An antenna moving across B{sub 0} has a radiation pattern characterized by an oscillatory “whistler wing.” A receiving antenna in motion can detect any plane wave within the group velocity resonance cone. The radiation pattern also depends on loop size relative to the wavelength. Motional effects prevent reciprocity. The concept of the radiation pattern loses its significance for wave packets since the received signal does not only depend on the antenna but also on the properties of the wave packet. The present results are of fundamental interest and of relevance to loop antennas in space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VARIABLE RADIO SOURCES IN THE GALACTIC PLANE

Using three epochs of Very Large Array observations of the Galactic plane in the first quadrant taken {approx}15 years apart, we have conducted a search for a population of variable Galactic radio emitters in the flux density range 1-100 mJy at 6 cm. We find 39 variable sources in a total survey area of 23.2 deg{sup 2}. Correcting for various selection effects and for the extragalactic variable population of active galactic nuclei, we conclude there are {approx}1.6 deg{sup -2} Galactic sources which vary by more than 50% on a time scale of years (or shorter). We show that these sources are much more highly variable than extragalactic objects; more than 50% show variability by a factor >2 compared to <10% for extragalactic objects in the same flux density range. We also show that the fraction of variable sources increases toward the Galactic center (another indication that this is a Galactic population), and that the spectral indices of many of these sources are flat or inverted. A small number of the variables are coincident with mid-IR sources and two are coincident with X-ray emitters, but most have no known counterparts at other wavelengths. Intriguingly, one lies at the center of a supernova remnant, while another appears to be a very compact planetary nebula; several are likely to represent activity associated with star formation regions. We discuss the possible source classes which could contribute to the variable cohort and follow-up observations which could clarify the nature of these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolution and Mass Range Performance in Distance-of-flight Mass Spectrometry with a Multichannel Focal-Plane Camera Detector.

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass-separation technique in which ions are separated in space along the plane of a spatially selective detector. In the present work, a solid-state charge-detection array, the focal-plane camera (FPC), was incorporated into the DOFMS platform. Use of the FPC with our DOFMS instrument resulted in improvements in analytical performance, usability, and versatility over a previous generation instrument that employed a microchannel-plate/phosphor DOF detector. Notably, FPC detection provided resolution improvements of at least a factor of 2, with typical DOF linewidths of 300 μm (R((fwhm)) = 1000). The merits of solid-state detection for DOFMS are evaluated, and methods to extend the DOFMS mass range are considered.

Array Detection↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

Interleaved Carbon Minibeams: An Experimental Radiosurgery Method With Clinical Potential

Purpose: To evaluate the efficacy of 'interleaved carbon minibeams' for ablating a 6.5-mm target in a rabbit brain with little damage to the surrounding brain. The method is based on the well-established tissue-sparing effect of arrays of thin planes of radiation. Methods and Materials: Broad carbon beams from the National Aeronautics and Space Agency Space Radiation Facility at Brookhaven National Laboratory were segmented into arrays of parallel, horizontal, 0.3-mm-thick planar beams (minibeams). The minibeams' gradual broadening in tissues resulted in 0.525-mm beam thickness at the target's proximal side in the spread-out Bragg peak. Interleaving was therefore implemented by choosing a 1.05 mm beam spacing on-center. The anesthetized rabbit, positioned vertically on a stage capable of rotating about a vertical axis, was exposed to arrays from four 90 Degree-Sign angles, with the stage moving up by 0.525 mm in between. This produced a solid radiation field at the target while exposing the nontargeted tissues to single minibeam arrays. The target 'physical' absorbed dose was 40.2 Gy. Results: The rabbit behaved normally during the 6-month observation period. Contrast magnetic resonance imaging and hematoxylin and eosin histology at 6 months showed substantial focal target damage with little damage to the surrounding brain. Conclusion: We plan to evaluate the method's therapeutic efficacy by comparing it with broad-beam carbon therapy in animal models. The method's merits would combine those of carbon therapy (i.e., tight target dose because of the carbon's Bragg-peak, sharp dose falloff, and high relative biological effectiveness at the target), together with the method's low impact on the nontargeted tissues. The method's smaller impact on the nontargeted brain might allow carbon therapy at higher target doses and/or lower normal tissue impact, thus leading to a more effective treatment of radioresistant tumors. It should also make the method more amenable to administration in either a single dose fraction or in a small number of fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Converging shock wave focusing and interaction with a target

Converging shock waves in liquids can be used efficiently in the research of the extreme state of matter and in various applications. In this paper, the recent results related to the interaction of a shock wave with plasma preliminarily formed in the vicinity of the shock wave convergence are presented. The shock wave is produced by the underwater electrical explosion of a spherical wire array. The plasma is generated prior to the shock wave's arrival by a low-pressure gas discharge inside a quartz capillary placed at the equatorial plane of the array. Analysis of the Stark broadening of H{sub α} and H{sub β} spectral lines and line-to-continuum ratio, combined with the ratio of the relative intensities of carbon C III/C II and silicon Si III/Si II lines, were used to determine the plasma density and temperature evolution. It was found that during the first ∼200 ns with respect to the beginning of the plasma compression by the shock wave and when the spectral lines are resolved, the plasma density increases from 2 × 10{sup 17 }cm{sup −3} to 5 × 10{sup 17 }cm{sup −3}, while the temperature remains at the same value of 3–4 eV. Further, following the model of an adiabatically imploding capillary, the plasma density increases >10{sup 19 }cm{sup −3}, leading to the continuum spectra obtained experimentally, and the plasma temperature >30 eV at radii of compression of ≤20 μm. The data obtained indicate that the shock wave generated by the underwater electrical explosion of a spherical wire array retains its uniformity during the main part of its convergence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Configurable luminaire

An array of LEDs is supported by a support mechanism that both supports conductors leading to the LEDs and sinks heat from the LEDs. The support mechanism may be a transparent heat-conducting sheet or an array of cantilevered arms at different angles that support the LEDs and sink heat. This reduces the blockage of light. The LEDs are positioned generally in the focal plane of an array of concave mirrors that collimate the light. The LEDs and array of mirrors are translatable with respect to one another to steer the aggregate light beam to customize the emission. In another embodiment, multiple LEDs are positioned over each mirror in the mirror array, and the combination of LEDs illuminated over each mirror is used to steer the aggregate light beam from the luminaire.

42 ENGINEERING↗

Configurable luminaire with light sources variably oriented with respect to an array of concave mirrors

An array of LEDs is supported by a support mechanism that both supports conductors leading to the LEDs and sinks heat from the LEDs. The support mechanism may be a transparent heat-conducting sheet or an array of cantilevered arms at different angles that support the LEDs and sink heat. This reduces the blockage of light. The LEDs are positioned generally in the focal plane of an array of concave mirrors that collimate the light. The LEDs and array of mirrors are translatable with respect to one another to steer the aggregate light beam to customize the emission. The LEDs may be variably oriented with respect to the associated mirror apertures so as to create different light beams emitted from different ones of the mirrors.

42 ENGINEERING↗