Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Quantitative Analysis of Fission-Product Surrogates in Molten Salt Chloride Aerosols

This work demonstrates laser-induced breakdown spectroscopy (LIBS) applied to a stream of aerosolized salt from molten eutectic LiCl-KCl. We demonstrate analytical capabilities to track fission-product surrogates of Cs, Sr, Pr, and Nd simultaneously, with application to monitor salts in pyroprocessing schemes and molten salt reactors. This work demonstrates limits of detection using LIBS on the order of 100 μg/g, which proves potentially applicable to monitoring fission-product concentrations in pyroprocessing applications. Additionally, this work explores fundamental aspects of plasma temperature and plasma electron density of the aerosolized species during LIBS with a specific focus on potential non-uniform plasma conditions in the aerosol.

74 - ATOMIC AND MOLECULAR PHYSICS↗

Electrode configuration for extended plasma confinement

Methods and systems are provided for plasma confinement utilizing various electrode and valve configurations. In one example, a device includes a first electrode positioned to define an outer boundary of an acceleration volume, a second electrode arranged coaxially with respect to the first electrode and positioned to define an inner boundary of the acceleration volume, at least one power supply to drive an electric current along a Z-pinch plasma column between the first second electrodes, and a set of valves to provide gas to the acceleration volume to fuel the Z-pinch plasma column, wherein an electron flow of the electric current is in a first direction from the second electrode to the first electrode. In additional or alternative examples, a shaping part is conductively connected to the second electrode to, in a presence of the gas, cause a gas breakdown of the gas to generate a sheared flow velocity profile.

Meier, Eric T.↗

Apparatus and method for extended plasma confinement

Methods and systems are provided for plasma confinement utilizing various electrode and valve configurations. In one example, a device includes a first electrode positioned to define an outer boundary of an acceleration volume, a second electrode arranged coaxially with respect to the first electrode and positioned to define an inner boundary of the acceleration volume, at least one power supply to drive an electric current along a Z-pinch plasma column between the first second electrodes, and a set of valves to provide gas to the acceleration volume to fuel the Z-pinch plasma column, wherein an electron flow of the electric current is in a first direction from the second electrode to the first electrode. In additional or alternative examples, a shaping part is conductively connected to the second electrode to, in a presence of the gas, cause a gas breakdown of the gas to generate a sheared flow velocity profile.

Shumlak, Uri↗

ElementLIBS User's Guide: An operational aid for use and development

Laser-Induced Breakdown Spectroscopy or LIBS is a rapid, in-situ analytical technique where a laser of known energy is pulsed at the surface of an analyte. The laser pulse rapidly heats a localized area to many thousand degrees Kelvin, ablating part of the analyte and turning it into a plasma. As the plasma cools, excited atoms return to a ground state with known emission energies. This emitted energy is captured by various spectrometers and provides a spectrum of the emitted energies and intensities. This spectrum can be analyzed to provide the elemental composition of a sample by using known emission lines and relative abundance. ElementLIBS was developed for the SciAps hand-held LIBS model Z300 but will work with any model that provides a LIBS spectrum of similar resolution. The Z300 has an integrated resolution of 1/30 nm with a range of approximately 180nm – 960nm, providing an output spectrum of 23431 pixels across three spectrometers. These criteria are only provided as a reference, as the software was designed to work with any size spectrum, provided the input file is of the correct format and the models were developed using the same framework. If spectra of varying dimensions are used, the software will fail without warning and unusual events could occur.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Filament-induced breakdown spectroscopy of solids through highly scattering media

Ultrafast laser pulse filamentation in the air can be used for remote sensing by exciting a characteristic optical emission, which is usually referred to as filamentation-induced breakdown spectroscopy. In environments that impede light propagation, such as fog, haze, or clouds, scattering makes it challenging to propagate laser beams and retrieve generated optical signatures. We demonstrate the effectiveness of laser filamentation for simultaneously clearing the path for intense femtosecond pulse propagation in a highly scattering medium, generation of luminous plasma on a solid target, and counter-propagation of a characteristic spectroscopic signal over a cleared channel along the filament path. In a dense cloud, the counter-propagating signal predominantly transits the cleared on-axis path but is highly affected by the negative thermal lensing of a Gaussian beam. Furthermore, these insights enhance our understanding of laser filamentation in atmospheric sensing and could substantially improve remote detection capabilities in poor visibility conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars

The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser-induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so-called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two-element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.

97 MATHEMATICS AND COMPUTING↗

Toward the Development of Molten Salt Reactor Diagnostics based on Resonantly Enhanced Laser Spectroscopy

One emerging concern within the safeguards community is how to best ensure compliance with nuclear security regulations within molten salt reactor (MSR) facilities. This problem is nontrivial as molten salts used for fuel or coolant are highly corrosive, chemically complex, and inherently require high operational temperatures. Laser spectroscopy methods such as laser-induced breakdown spectroscopy (LIBS) and laser-induced fluorescence (LIF) have previously been suggested for molten salt diagnostics due to their compatibility with liquid phase samples and potential for in-situ measurements [1]. In the former, the laser is used to ionize the sample, allowing for the characteristic light from electronic de-excitation as the resultant plasma cools to be used for material characterization. In the latter, a tunable light source is set be resonant with a specific transition, resulting in element specific excitation and the emission of fluorescence light. In our previous work [2], we demonstrated that LIF could be used for the detection of fission fragments such as Nd in solution through the separation of laser scatter and fluorescence within the time domain. Here, we present progress towards two alternate measurement schemes: LIF measurements based on spectroscopic discrimination of fluorescence emissions and resonant LIBS measurements that induce plasma using a light source set to the resonant frequency of a specific electronic transition. Both methods aim to exploit resonant excitation methods to enhance the emitted signal. The studies may provide routes for element-specific detection of constituents within complicated matrices and a means to better understand the chemical behavior of lanthanides and actinides relevant to MSRs.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Breakdown and Discharge Characteristics of High Repetition Frequency Nanosecond Pulsed Air Dielectric Barrier Discharge

This study explores the breakdown characteristics and discharge modes in a parallel plate air dielectric barrier discharge system using repetitive nanosecond pulses, with pulse repetition frequencies (PRFs) from 0.1 to 100 kHz. It examines how pulse parameters—PRF, pulse number and gas pressure—affect the memory effect, leveraging current and voltage measurements, fast imaging and optical emission spectroscopy. The findings show that higher PRFs lead to a reduction in breakdown voltage well below the streamer breakdown threshold. We argue that this effect may be attributed to the cumulative buildup of metastable species and negative ions in the discharge gap which could sustain free electrons in‐between the voltage pulses. Despite observing increased energy deposition with higher PRFs, the impact on filament formation was minimal, highlighting a strong dependence of discharge morphology on the accumulation of plasma‐produced species. This research studies provides valuable insights for controlling discharge regimes in applications such as plasma‐assisted combustion, surface treatment and air treatment by clarifying the interactions between discharge mechanisms at different PRFs and pressures.

42 ENGINEERING↗

Laser-Induced Plasmas of Plutonium Dioxide in a Double-Walled Cell

Plutonium research has been stifled by the significant number of administrative controls and safety procedures, space and instrumentation limitations in radiological gloveboxes, and the potential for personnel and equipment contamination. To address the limited number of spectroscopic studies in Pu-bearing compounds in the current scientific literature, this work presents the use of double-walled cells (DWCs) in “clean” buildings/laboratories as an alternative to research in radiological gloveboxes. This study reports the first laser-induced breakdown spectroscopy (LIBS) experiments of a PuO 2 pellet contained within a DWC, where the formation of elemental (atomic and ionic) species as well as the evolution from elemental to molecular products (Pu x O y ) was measured. Raman spectroscopy was also used to characterize the surface of the ablated pellet and the particulates deposited on the window of the inner cell. The full width half-maximum of the T 2g band enabled us to obtain an estimate of the temperature at the pellet surface after the ablation pulse and the particulates based on the crystal lattice disorder. Particulates deposited on the window of the DWC during laser ablation were characterized using scanning electron microscopy, where molten irregular particulates and spheroids were observed. This exciting research conducted in a DWC describes our initial attempts to incorporate LIBS in the arsenal of spectroscopic tools for nuclear forensics applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial transient stage of pin-to-pin nanosecond repetitively pulsed discharges in air

In this work, evolution of parameters of nanosecond repetitively pulsed (NRP) discharges in pin-to-pin configuration in air was studied during the transient stage of initial 20 discharge pulses. Gas and plasma parameters in the discharge gap were measured using coherent microwave scattering, optical emission spectroscopy, and laser Rayleigh scattering for NRP discharges at repetition frequencies of 1, 10, and 100 kHz. Memory effects (when perturbations induced by the previous discharge pulse would not decay fully until the subsequent pulse) were detected for the repetition frequencies of 10 and 100 kHz. For 10 kHz NRP discharge, the discharge parameters experienced significant change after the first pulse and continued to substantially fluctuate between subsequent pulses due to rapid evolution of gas density and temperature during the 100 μs inter-pulse time caused by intense redistribution of the flow field in the gap on that time scale. For 100 kHz NRP discharge, the discharge pulse parameters reached a new steady-state at about five pulses after initiation. Further, this new steady-state was associated with well-reproducible parameters between the discharge pulses and substantial reduction in breakdown voltage, discharge pulse energy, and electron number density in comparison to the first discharge pulse. For repetition frequencies 1–100 kHz considered in this work, the memory effects can be likely attributed to the reduction in gas number density and increase in the gas temperature that cannot fully recover to ambient conditions before subsequent discharge pulses.

42 ENGINEERING↗

Excitation of optically trapped single particles using femtosecond pulses

Excitation from optically trapped particles is examined through laser-induced breakdown spectroscopy following interactions with mJ-level fs pulses. Optical emissions from sub-ng ablation of precisely positioned cupric oxide microparticles are used as a method to spatially resolve laser–particle interactions resulting in excitation. External focusing lenses are often used to change the dynamics of nonlinear self-focusing of fs pulses to form laser filaments or, alternatively, to form very intense air plasmas. Given the significant implications external focusing has on laser propagation and plasma conditions, single-particle emissions are studied with focusing lenses ranging from 50 to 300 mm. It is shown that, while single particles are less excited at longer focal lengths due to limited energy transfer through laser–particle interactions, the cooler plasma results in a lower thermal background to reveal resolved single-shot emission peaks. Furthermore, by developing an understanding in the fundamental interaction that occurs between single particles and fs pulses and filaments, practical improvements can be made for atmospheric remote sensing of low-concentration aerosols.

42 ENGINEERING↗

Few-cycle optical field breakdown and damage of gallium oxide and gallium nitride

Both gallium oxide and gallium nitride have great potential for use as high power transparent conducting oxide materials for a wide range of optoelectronic applications. It is, therefore, important to determine the dynamic optical field breakdown for these materials. Here, we report laser damage thresholds for Ga 2 O 3 and GaN using 9 fs few-cycle pulses with a center wavelength near 760 nm. We determine laser-induced damage thresholds (LIDTs) for both single pulse and multi-pulse exposures, with multi-pulse LIDT showing significant reduction compared to single pulse LIDT (in some cases, >50%), possibly due to laser-induced defects. We show that Ga 2 O 3 and GaN have an ultrafast optical field breakdown of 23 and 18 GV/m when nearly polarized along their [010] and [111] planes, respectively, extending their suitability for high power applications to the ultrashort pulse regime. To accurately characterize the excited carrier density criteria in which apparent laser damage occurs, carrier excitation dynamics for the entire laser pulse interaction were simulated using a modified Keldysh ionization model. For the measured single-shot threshold fluences, the plasma critical density was surpassed by 2 orders of magnitude and 2D finite-difference time-domain simulations were employed to understand the pulse interaction near the surface.

Tripepi, Michael↗

Development of Laser-Induced Breakdown Spectroscopy for the Californium-252 Supply Program

Calibration-free–laser-induced breakdown spectroscopy (CF-LIBS) is suggested as an alternative to traditional LIBS because it does not rely on calibration curves and instead relies on previously reported parameters called transition probabilities. Transition probabilities are fundamental parameters that describe the probability a specific transition from an upper energy to a lower energy will occur. These values act as internal calibrations and allow concentrations to be calculated based on the plasma temperature and electron density, which can be determined from Saha-Boltzmann methods. CF-LIBS provides the ability to perform elemental concentration estimations on samples without the need for chemical dilutions and only nanograms of material are ablated into the plasma. These benefits can be applied remotely inside hot cells, glove boxes, and radiation hoods through optical fibers. This report summarizes recent efforts to develop CF-LIBS methods for future applications within Oak Ridge National Laboratory’s radioisotope production portfolio, such as the Cf-252 Supply Program. Summaries are provided for the developed Python scripts for data analysis and two studies employing these programs to determine unreported transition probabilities of relevant lanthanides. Additionally, a review of fiber-delivered LIBS and a discussion of a LIBS fiber probe design are provided.

07 ISOTOPE AND RADIATION SOURCES↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Quantification of Lanthanides in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy

To enable the deployment of molten salt reactor technology, the development of off-gas treatment systems and advanced monitoring tools capable of operating with high temperatures and radiation fields while delivering near real-time information is necessary. Here, we aim to fulfill this requirement and proposes laser-induced breakdown spectroscopy (LIBS) for monitoring molten salt aerosol streams. A sheath gas measuring method was developed to protect optical elements from aerosol particles and to ensure a relatively constant aerosol stream for measurement. An aqueous system was studied to demonstrate the utility of LIBS for monitoring possible fission products in an aerosol stream: Gd, Nd, and Sm up to 2000 parts per million (ppm). A calibration model was built using partial least squares (PLS) regression with five, six, and nine latent variables for Gd, Nd, and Sm, respectively. This calibration model successfully estimated the concentrations of three test samples, which were validated with inductively charged plasma optical emission spectroscopy measurements at a 99.9% confidence interval. To enhance these models, a genetic algorithm was used to filter the spectra before entering the PLS model, thereby limiting the spectral features being regressed to those with greater correlations to concentration. This allowed for the number of latent variables used in the PLS models to be reduced to four, three, and three for Gd, Nd, and Sm, respectively. Finally, the genetic algorithm-filtered PLS models were used to predict the concentrations of the aerosol stream on a real-time dataset and resulted in a 73%, 18%, and 25% improvement in root mean squared error of prediction compared to the original PLS models developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Rare Earth Element Detection and Quantification in Coal and Rock Mineral Matrices

As global demand for rare earth elements (REEs) increases, maintaining the production and supply chain is critical. Technologies capable of being used in the field and in situ in the subsurface for rapid REE detection and quantification facilitates the efficient mining of known resources and exploration of new and unconventional resources. Laser-induced breakdown spectroscopy (LIBS) is a promising technique for rapid elemental analysis both in the laboratory and in the field. Multiple articles have been published evaluating LIBS for detection and quantification of REEs; however, REEs in their natural deposits have not been adequately studied. In this work, detection and quantification of two REEs, La and Nd, have been studied in both synthetic and natural mineral matrices at concentrations relevant to REE extraction. Measurements were performed on REE-containing rock and coal samples (natural and synthetic) utilizing different LIBS instruments and techniques, specifically a commercial benchtop instrument, a custom benchtop instrument (single- and double-pulse modes), and a custom LIBS probe currently being developed for in situ, subsurface, borehole wall detection and quantification of REEs. Plasma expansion, emission intensity, detection limits, and double-pulse signal enhancement were studied. The limits of detection (LOD) were found to be 10/14 ppm for La and 15/25 ppm for Nd in simulated coal/rock matrices in single-pulse mode. Signal enhancement of 3.5 to 6-fold was obtained with double-pulse mode as compared to single-pulse operation.

La detection↗