Search NASA⌕ Search

SEARCH · Search NASA

Results for “plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Heat Transfer on a Film-Cooled Blade - Effect of Hole Physics

A multi-block, three-dimensional Navier-Stokes code has been used to study the within-hole and near-hole physics in relation to heat transfer on a film-cooled blade. The flow domain consists of the coolant flow through the plenum and hole-pipes for the three staggered rows of shower-head holes on the VK1 rotor, and the main flow over the blade. A multi-block grid is generated that is nearly orthogonal to the various surfaces. It may be noted that for the VK1 rotor the shower-head holes are inclined at 30 deg. to the spanwise direction, and are normal to the streamwise direction on the blade. Wilcox's k-omega turbulence model is used. The present study provides a much better comparison for the heat transfer coefficient at the blade mid-span with the experimental data than an earlier analysis wherein coolant velocity and temperature distributions were specified at the hole exits rather than extending the computational domain into the hole-pipe and plenum. Details of the distributions of coolant velocity, temperature, k and omega at the hole exits are also presented.

Garg, Vijay K.↗

Heat Transfer on a Film-Cooled Blade: Effect of Hole Physics

A multiblock, three-dimensional Navier Stokes code has been used to study the within-hole and near-hole physics in relation to heat transfer on a film-cooled blade. The flow domain consists of the coolant flow through the plenum and hole-pipes for the three staggered rows of shower-head holes on the VKI rotor, and the main flow over the blade. A multiblock grid is generated that is nearly orthogonal to the various surfaces. It may be noted that for the VKI rotor the shower-head holes are inclined at 30 deg to the spanwise direction, and are normal to the streamwise direction on the blade. Wilcox's k-omega turbulence model is used. The present study provides a much better comparison for the span-averaged heat transfer coefficient on the blade surface with the experimental data than an earlier analysis wherein coolant velocity and temperature distributions were specified at the hole exits rather than extending the computational domain into the hole-pipe and plenum. Details of the distributions of coolant velocity, temperature, k and omega at the hole exits are also presented.

Garg, Vijay K.↗

Numerical Investigation of the ARMSEF Arc-Jet

The NASA/JSC 10 MW Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) is used for the development and evaluation of thermal protection systems for manned reentry vehicles. In an effort at better understanding the flow characteristics of an arc-jet wind tunnel and hence the correlation between simulation and actual flight conditions, preliminary numerical analyses have been made. Difficulties in defining inlet boundary conditions to the plenum chamber, where there is very little usable experimental data, are discussed. Two different boundary conditions for the plenum, a straight profile and parabolic profile, are employed to describe the conditions in this very important flow defining region. Comparisons are made to experimental data with the results showing that some type of parabolic or step profile is needed to adequately resolve the strong core flow that is present in the nozzle and plume region. Recommendations are made regarding future efforts in analyzing this challenging flow field.

Cox, Carey F.↗

LeRC NATR Free-Jet Development

The Nozzle Acoustic Test Rig (NATR) was developed to provide additional test capabilities at Lewis needed to meet HSR program goals. The NATR is a large f ree-jet facility (free-jet diameter = 53 in.) with a design Mach number of 0.3. It is located inside a geodesic dome, adjacent to the existing Powered Lift Facility (PLF). The NATR allows nozzle concepts to be acoustically assessed for far-field (approximately 50 feet) noise characteristics under conditions simulating forward flight. An ejector concept was identified as a means of supplying the required airflow for this free-jet facility. The primary stream is supplied through a circular array of choked nozzles and the resulting low pressure in the constant, annular- area mixing section causes a "pumping" action that entrains the secondary stream. The mixed flow expands through an annular diffuser and into a plenum chamber. Once inside the plenum, the flow passes over a honeycomb/screen combination intended to remove large disturbances and provide uniform flow. The flow accelerates through an elliptical contraction section where it achieves a free-jet Mach number of up to 0.3.

Long-Davis, M.↗

Modeling Film-Coolant Flow Characteristics at the Exit of Shower-Head Holes

The coolant flow characteristics at the hole exits of a film-cooled blade are derived from an earlier analysis where the hole pipes and coolant plenum were also discretized. The blade chosen is the VKI rotor with three staggered rows of shower-head holes. The present analysis applies these flow characteristics at the shower-head hole exits. A multi-block three-dimensional Navier-Stokes code with Wilcox's k-omega model is used to compute the heat transfer coefficient on the film-cooled turbine blade. A reasonably good comparison with the experimental data as well as with the more complete earlier analysis where the hole pipes and coolant plenum were also gridded is obtained. If the 1/7th power law is assumed for the coolant flow characteristics at the hole exits, considerable differences in the heat transfer coefficient on the blade surface, specially in the leading-edge region, are observed even though the span-averaged values of h (heat transfer coefficient based on T(sub o)-T(sub w)) match well with the experimental data. This calls for span-resolved experimental data near film-cooling holes on a blade for better validation of the code.

Garg, Vijay K.↗

Progress in the Development of a Nozzle Design Methodology for Pulsed Detonation Engines

The Johns Hopkins University Applied Physics Laboratory (JHU/APL), in support of the NASA Glenn Research Center (NASA GRC), is investigating performance methodologies and system integration issues related to Pulsed Detonation Engine (PDE) nozzles. The primary goal of this ongoing effort is to develop design and performance assessment methodologies applicable to PDE exit nozzle(s). APL is currently focusing its efforts on a common plenum chamber design that collects the exhaust products from multiple PDE tubes prior to expansion in a single converging-diverging exit nozzle. To accomplish this goal, a time-dependent, quasi-one-dimensional analysis for determining the flow properties in and through a single plenum and exhaust nozzle is underway. In support of these design activities, parallel modeling efforts using commercial Computational Fluid Dynamics (CFD) software are on-going. These efforts include both two and three-dimensional as well as steady and time-dependent computations to assess the flow in and through these devices. This paper discusses the progress in developing this nozzle design methodology.

Leary, B. A.↗

Performance Evaluation of the NEXT Ion Engine

The performance test results of three NEXT ion engines are presented. These ion engines exhibited peak specific impulse and thrust efficiency ranges of 4060 4090 s and 0.68 0.69, respectively, at the full power point of the NEXT throttle table. The performance of the ion engines satisfied all project requirements. Beam flatness parameters were significantly improved over the NSTAR ion engine, which is expected to improve accelerator grid service life. The results of engine inlet pressure and temperature measurements are also presented. Maximum main plenum, cathode, and neutralizer pressures were 12,000 Pa, 3110 Pa, and 8540 Pa, respectively, at the full power point of the NEXT throttle table. Main plenum and cathode inlet pressures required about 6 hours to increase to steady-state, while the neutralizer required only about 0.5 hour. Steady-state engine operating temperature ranges throughout the power throttling range examined were 179 303 C for the discharge chamber magnet rings and 132 213 C for the ion optics mounting ring.

Soulas, George C.↗

Gas arc constriction for plasma arc welding

A welding torch for plasma arc welding apparatus has an inert gas applied circumferentially about the arc column externally of the constricting nozzle so as to apply a constricting force on the arc after it has exited the nozzle orifice and downstream of the auxiliary shielding gas. The constricting inert gas is supplied to a plenum chamber about the body of the torch and exits through a series of circumferentially disposed orifices in an annular wall forming a closure at the forward end of the constricting gas plenum chamber. The constricting force of the circumferential gas flow about the arc concentrates and focuses the arc column into a more narrow and dense column of energy after exiting the nozzle orifice so that the arc better retains its energy density prior to contacting the workpiece.

McGee, William F.↗

Aircraft anti-insect system

Insect debris is removed from or prevented from adhering to insect impingement areas of an aircraft, particularly on an inlet cowl of an engine, by heating the area to 180.degree.-500.degree. C. An apparatus comprising a means to bring hot air from the aircraft engine to a plenum contiguous to the insect impingement area provides for the heating of the insect impingement areas to the required temperatures. The plenum can include at least one tube with a plurality of holes contained in a cavity within the inlet cowl. It can also include an envelope with a plurality of holes on its surface contained in a cavity within the inlet cowl.

Spiro, Clifford Lawrence↗

Modeling of Fixed-Exit Porous Bleed Systems

A model has been developed to simulate a fixed-exit porous bleed system for supersonic inlets. The fixed-exit model allows the amount of bleed flow to vary according to local flow conditions and fixed-exit characteristics of the bleed system. This variation is important for the control of shock-wave/boundary-layer interactions within the inlet. The model computes the bleed plenum static pressure rather than requiring its specification. The model was implemented in the Wind-US computational fluid dynamics code. The model was then verified and validated against experimental data for bleed on a flat plate with and without an impinging oblique shock and for bleed in a Mach 3.0 axisymmetric, mixed-compression inlet. The model was able to accurately correlate the plenum pressures with bleed rates and simulate the effect of the bleed on the downstream boundary layer. Further, the model provided a realistic simulation of the initiation of inlet unstart. The results provide the most in-depth examination to date of bleed models for use in the simulation of supersonic inlets. The results also highlight the limitations of the models and aspects that require further research.

Slater, John W.↗

Amplitude of Supersonic Diffuser Flow Pulsations

A theoretical method for evaluating the stability characteristics and the amplitude and the frequency of pulsation of ram-jet engines without heat addition is presented herein. Experimental verification of the theoretical results are included where data were available. Theory and experiment show that the pulsation amplitude of a high mass-flow-ratio diffuser having no cone surface flow separation increases with decreasing mass flow. The theoretical trends for changes in amplitude, frequency, and mean-pressure recovery with changes in plenum-chamber volume were experimentally confirmed. For perforated convergent-divergent-type diffusers, a stability hysteresis loop was predicted on the pressure-recovery mass-flow-ratio curve. At a given mean mass-flow ratio, the higher.value of mean pressure recovery corresponded to oscillatory flow in the diffuser while the lower branch was stable. This hysteresis has been observed experimentally. The theory indicates that for a ram-jet engine of given diameter, the amplitude of pulsation of a supersonic diffuser is increased by decreasing the relative size of the plenum chamber with respect to the diffuser volume down to a critical value at which oscillations cease. In the region of these critical values, the stable mass-flow range of the diffuser may be increased either by decreasing the combustion chamber volume or by increasing the length of the diffuser.

Sterbentz, William H.↗

Membrane-Based Water Evaporator for a Space Suit

A membrane-based water evaporator has been developed that is intended to serve as a heat-rejection device for a space suit. This evaporator would replace the current sublimator that is sensitive to contamination of its feedwater. The design of the membrane-based evaporator takes advantage of recent advances in hydrophobic micropore membranes to provide robust heat rejection with much less sensitivity to contamination. The low contamination sensitivity allows use of the heat transport loop as feedwater, eliminating the need for the separate feedwater system used for the sublimator. A cross section of the evaporator is shown in the accompanying figure. The space-suit cooling loop water flows into a distribution plenum, through a narrow annulus lined on both sides with a hydrophobic membrane, into an exit plenum, and returns to the space suit. Two perforated metal tubes encase the membranes and provide structural strength. Evaporation at the membrane inner surface dissipates the waste heat from the space suit. The water vapor passes through the membrane, into a steam duct and is vented to the vacuum environment through a back-pressure valve. The back-pressure setting can be adjusted to regulate the heat-rejection rate and the water outlet temperature.

Ungar, Eugene K.↗

Paint-Overspray Catcher

An apparatus to catch paint overspray has been proposed. Overspray is an unavoidable parasitic component of spray that occurs because the flow of air or other gas in the spray must turn at the sprayed surface. Very small droplets are carried away in this turning flow, and some land on adjacent surfaces not meant to be painted. The basic principle of the paint-spray catcher is to divert the overspray into a suction system at the boundary of the area to be painted. The paint-spray catcher (see figure) would include a toroidal plenum connected through narrow throat to a nozzle that would face toward the center of the torus, which would be positioned over the center of the area to be spray-painted. The plenum would be supported by four tubes that would also serve as suction exhaust ducts. The downstream ends of the tubes (not shown in the figure) would be connected to a filter on a suction pump. The pump would be rated to provide a suction mass flow somewhat greater than that of the directed spray gas stream, so that the nozzle would take in a small excess of surrounding gas and catch nearly all of the overspray. A small raised lip at the bottom edge of the nozzle would catch paint that landed inside the nozzle. Even if the paint is directly piston pumped, the droplets entrain an air flow by time they approach the wall, so there is always a gas stream to carry the excess droplets to the side. For long-duration spraying operations, it could be desirable to include a suction-drain apparatus to prevent overflowing and dripping of paint from inside the lip. A version without an external contraction and with the throat angled downward would be a more compact version of catcher, although it might be slightly less efficient.

Weinstein, Leonard M.↗

Emission Spectroscopy and Radiometric Measurements in the NASA Ames IHF Arc Jet Facility

Plasma diagnostic measurement campaigns in the NASA Ames Interaction Heating Facility (IHF) have been conducted over the last several years with a view towards characterizing the flow in the arc jet facility by providing data necessary for modeling and simulation. Optical emission spectroscopy has been used in the plenum and in the free jet of the nozzle. Radiation incident over a probe surface has also been measured using radiometry. Plenum measurements have shown distinct radial profiles of temperature over a range of operating conditions. For cases where large amounts of cold air are added radially to the main arc-heated stream, the temperature profiles are higher by as much as 1500 K than the profiles assumed in flow simulations. Optical measurements perpendicular to the flow direction in the free jet showed significant contributions to the molecule emission through inverse pre-dissociation, thus allowing determination of atom number densities from molecular emission. This has been preliminarily demonstrated with the N2 1st Positive System. Despite the use of older rate coefficients, the resulting atom densities are reasonable and surprisingly close to flow predictions.

Winter, Michael W.↗

Active Aircraft Pylon Noise Control System

An active pylon noise control system for an aircraft includes a pylon structure connecting an engine system with an airframe surface of the aircraft and having at least one aperture to supply a gas or fluid therethrough, an intake portion attached to the pylon structure to intake a gas or fluid, a regulator connected with the intake portion via a plurality of pipes, to regulate a pressure of the gas or fluid, a plenum chamber formed within the pylon structure and connected with the regulator, and configured to receive the gas or fluid as regulated by the regulator, and a plurality of injectors in communication with the plenum chamber to actively inject the gas or fluid through the plurality of apertures of the pylon structure.

Thomas, Russell H.↗

Active Aircraft Pylon Noise Control System

An active pylon noise control system for an aircraft includes a pylon structure connecting an engine system with an airframe surface of the aircraft and having at least one aperture to supply a gas or fluid therethrough, an intake portion attached to the pylon structure to intake a gas or fluid, a regulator connected with the intake portion via a plurality of pipes, to regulate a pressure of the gas or fluid, a plenum chamber formed within the pylon structure and connected with the regulator, and configured to receive the gas or fluid as regulated by the regulator, and a plurality of injectors in communication with the plenum chamber to actively inject the gas or fluid through the plurality of apertures of the pylon structure.

Thomas, Russell H.↗

Sorbent-Based Atmosphere Revitalization System

The present invention is a sorbent-based atmosphere revitalization (SBAR) system using treatment beds each having a bed housing, primary and secondary moisture adsorbent layers, and a primary carbon dioxide adsorbent layer. Each bed includes a redirecting plenum between moisture adsorbent layers, inlet and outlet ports connected to inlet and outlet valves, respectively, and bypass ports connected to the redirecting plenums. The SBAR system also includes at least one bypass valve connected to the bypass ports. An inlet channel connects inlet valves to an atmosphere source. An outlet channel connects the bypass valve and outlet valves to the atmosphere source. A vacuum channel connects inlet valves, the bypass valve and outlet valves to a vacuum source. In use, one bed treats air from the atmosphere source while another bed undergoes regeneration. During regeneration, the inlet, bypass, and outlet valves sequentially open to the vacuum source, removing accumulated moisture and carbon dioxide.

Knox, James C↗

MODELING STRATEGIES TO COMPUTE NATURAL CIRCULATION USING CFD IN A VHTR AFTER A LOFA

A prismatic gas-cooled very high temperature reactor (VHTR) is being developed under the next generation nuclear plant program (NGNP) of the U.S. Department of Energy, Office of Nuclear Energy. In the design of the prismatic VHTR, hexagonal shaped graphite blocks are drilled to allow insertion of fuel pins, made of compacted TRISO fuel particles, and coolant channels for the helium coolant. One of the concerns for the reactor design is the effects of a loss of flow accident (LOFA) where the coolant circulators are lost for some reason, causing a loss of forced coolant flow through the core. In such an event, it is desired to know what happens to the (reduced) heat still being generated in the core and if it represents a problem for the fuel compacts, the graphite core or the reactor vessel (RV) walls. One of the mechanisms for the transport of heat out of the core is by the natural circulation of the coolant, which is still present. That is, how much heat may be transported by natural circulation through the core and upwards to the top of the upper plenum? It is beyond current capability for a computational fluid dynamic (CFD) analysis to perform a calculation on the whole RV with a sufficiently refined mesh to examine the full potential of natural circulation in the vessel. The present paper reports the investigation of several strategies to model the flow and heat transfer in the RV. It is found that it is necessary to employ representative geometries of the core to estimate the heat transfer. However, by taking advantage of global and local symmetries, a detailed estimate of the strength of the resulting natural circulation and the level of heat transfer to the top of the upper plenum is obtained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗