Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Sensitivity of thermodynamic profiles retrieved from ground-based microwave and infrared observations to additional input data from active remote sensing instruments and numerical weather prediction models

Accurate and continuous estimates of the thermodynamic structure of the lower atmosphere are highly beneficial to meteorological process understanding and its applications, such as weather forecasting. In this study, the Tropospheric Remotely Observed Profiling via Optimal Estimation (TROPoe) physical retrieval is used to retrieve temperature and humidity profiles from various combinations of input data collected by passive and active remote sensing instruments, in situ surface platforms, and numerical weather prediction models. Among the employed instruments are microwave radiometers (MWRs), infrared spectrometers (IRSs), radio acoustic sounding systems (RASSs), ceilometers, and surface sensors. TROPoe uses brightness temperatures and/or radiances from MWRs and IRSs, as well as other observational inputs (virtual temperature from the RASS, cloud-base height from the ceilometer, pressure, temperature, and humidity from the surface sensors) in a physical iterative retrieval approach. This starts from a climatologically reasonable profile of temperature and water vapor, with the radiative transfer model iteratively adjusting the assumed temperature and humidity profiles until the derived brightness temperatures and radiances match those observed by the MWR and/or IRS instruments within a specified uncertainty, as well as within the uncertainties of the other observations, if used as input. In this study, due to the uniqueness of the dataset that includes all the above-mentioned sensors, TROPoe is tested with different observational input combinations, some of which also include information higher than 4 km above ground level (a.g.l.) from the operational Rapid Refresh numerical weather prediction model. These temperature and humidity retrievals are assessed against independent collocated radiosonde profiles under non-cloudy conditions to assess the sensitivity of the TROPoe retrievals to different input combinations.

54 ENVIRONMENTAL SCIENCES↗

High sensitivity pressure and temperature quantum sensing in pentacene-doped p-terphenyl single crystals

Quantum sensors’ responsiveness to their physical environment enables detection of variables such as temperature (T), pressure (P), and strain. We present a molecular platform for PT sensing using para-terphenyl crystals doped with pentacene (PDP), leveraging optically detected magnetic resonance (ODMR) of photoexcited triplet electron spins. We observe maximal frequency variations of df/dP=1.8 MHz/bar from 0-8 bar and df/dT=247 kHz/K from 79–330 K, over 1200 times and threefold greater, respectively, than those seen with nitrogen-vacancy centers in diamond and > 85-fold greater pressure sensitivity over the previous record. Density functional theory calculations indicate picometer-level PT-induced molecular orbital shifts are measurable via ODMR. PDP offers additional advantages including high sensor doping levels, narrow ODMR linewidths, high contrast, and low-cost single crystal growth. Overall, this work reports low-cost, optically-interrogated PT sensors and lays the foundation for increased versatility of quantum sensors through synthetic molecular design.

Magnetic properties and materials↗

Groundwater level elevation and temperature data, Oct 2018-Dec 2021, Slate River Floodplain, Crested Butte, CO

This data package includes a time series of water level and temperature measurements from October 2018 to December 2021 in groundwater and surface water from the Slate River floodplain outside Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data were recorded by pressure transducers were installed in four types of piezometers: 1) a network of gravel bed ("GB") drive-point piezometers with a 6-inch screen interval installed all at ~330 cm below ground surface. 2) a network of piezometers screened across the water table, used to measure evapotranspiration ("ET") using the White method. Each of these piezometers is screened along almost its entire length.3) a suite nested piezometers used the measure the vertical hydraulic gradient ("VHG") across the fines-cobble interface. Each of these piezometers uses a 6-inch screen length.4) a group of piezometers scattered across the boundaries of the floodplain, used to monitor boundary conditions ("BC") flowing into and out of the floodplain. With the exception of "SR-BD-WT", each of these piezometers is screened along its entire length. Within the data package, "FLMD.csv" describes file-level metadata and "dd.csv" defines column headers and universal terms across the dataset. The data package includes 11 "*data.csv" files, one for each piezometer type for each calendar year. Because piezometers have been added over time, not every sensor has data dating back to Oct 2018. Each "*data.csv" file has a corresponding "*_InstallationMethods.csv" file that describes the location, elevation, screen depth, sediment type and sensor metadata for each piezometer and pressure transducer.

54 ENVIRONMENTAL SCIENCES↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗

In situ characterization of the biological performance of a Francis turbine retrofitted with a modular guide vane

There are two strategies to lower overall project costs to an extent that will make many potential sustainable hydropower sites economically viable: (1) design standardized/modular components; (2) use advanced tools to reduce environmental evaluation costs. In this study an autonomous sensor device (Sensor Fish) was used to study a Francis turbine retrofitted with a modular guide vane. The median nadir pressures measured were 74.7, 66.6, and 56.6 kPaA for 90-, 190-, and 380-kW operating conditions respectively. These nadir pressures were compared to other Francis turbines studied using Sensor Fish and were found to be within the same range. The proportion of Sensor Fish releases with severe acceleration events (acceleration = 95G) was also investigated. The proportion ranged from 73 to 80% (runner region), 50 to 64% (guide vane region), and 9 to 28% (draft tube region), which was within the range of the other turbines used for comparison. The Sensor Fish testing that was conducted at Hurley Dam demonstrates that the modular guide vane that was retrofitted to the existing Francis turbine is potentially a suitable replacement that can provide biological performance similar to the guide vane used with other existing Francis turbines, but with the benefit of reduced fabrication costs.

13 HYDRO ENERGY↗

Robust Carbon Dioxide Plume Imaging Using Joint Tomographic Inversion of Seismic Onset Time and Distributed Pressure and Temperature Measurements (Final Report)

We develop and demonstrate rapid and cost-effective methodologies for spatiotemporal tracking of CO2 plumes during geologic sequestration using joint inversion of seismic data and distributed pressure and temperature measurements. Key elements of our methodology are: (a) a computationally efficient approach to pressure and temperature propagation, (b) analysis of time lapse seismic data using a novel ‘seismic onset time’ approach to detect fluid front propagation, and (c) data assimilation and uncertainty assessment via joint inversion of pressure, temperature and time lapse seismic data, and (d) validating the numerical tomographic inversion using a CO2 injection demonstration projects, specifically data collected from the from the Petra Nova Parish Holdings CCUS project in the West Ranch Field, Texas and the Chester-16 reef CO2 injection site in Northern Michigan which is part of the DOE Midwestern Carbon Sequestration Project. The research team is led by Texas A&M University and includes Battelle as a subcontractor with support from Shell, Anadarko, Chevron and JX Nippon. A carbon dioxide (CO2) water-alternating-gas (WAG) pilot was conducted to gain insights into tertiary oil recovery potential via CO2 flood in the West Ranch Field as part of the Petra Nova project, the world’s largest post-combustion CO2 capture and utilization initiative. With a fluvial formation geology and large contrasts in permeability, this is a challenging and novel application of CO2 enhanced oil recovery (EOR). We build a predictive dynamic model of the subsurface that incorporates the multiphase and compositional data acquired during the pilot operation. The calibrated model is used for the carbon dioxide plume imaging. The study began with an initialization of the pilot sector model extracted from a calibrated full-field model. The pilot model calibration follows a two-step hierarchical workflow. First, we performed a large-scale update of the permeability distribution by integrating available bottomhole pressure and multiphase production data. In the second step, local permeability field is fine-tuned using a streamline-based method to match CO2 breakthrough times at the producers. The predictive capability of the calibrated model was verified through two blind validation tests: (1) the model showed good agreement with saturation logs acquired at two observation wells; and (2) the model reproduced the CO2 recovery as a fraction of the injected CO2. The use of seismic onset times has shown great promise for integrating near-continuous seismic surveys for updating geologic models. In this study, we analyze the impact of seismic survey frequency on the onset time approach aiming to extend the application of onset time to infrequent seismic surveys. In addition, we quantitatively examine the nonlinearity of the onset time method and compare it to the commonly used amplitude inversion method. We carry out a sensitivity analysis of seismic survey frequency based on the complete seismic survey data (over 175 surveys) of steam injection in a heavy oil reservoir (Peace River Unit) in Canada. Our results show that an adequate onset time map can be obtained from the infrequent seismic surveys by interpolation between seismic surveys as long as there is no change in the dominant underlying physics between the successive surveys. The study also shows that nonlinearity of the onset time method can be -smaller than that of the amplitude inversion method by several orders of magnitude. Application to the Brugge benchmark case shows that the onset time method obtains comparable permeability update as the traditional seismic amplitude inversion method with faster computation and improved convergence characteristics. We extend the streamline-based data integration approach to incorporate distributed temperature sensor (DTS) data using the concept of thermal tracer travel time. Then, a hierarchical workflow composed of evolutionary and streamline methods is employed to jointly history match the DTS and pressure data. Finally, CO2 saturation and streamline maps are used to visualize the CO2 plume movement during the sequestration process. The hierarchical workflow is applied to a carbon sequestration project in a carbonate reef reservoir within the Northern Niagaran Pinnacle Reef Trend in Michigan, USA. The monitoring data set consists of distributed temperature sensing (DTS) data acquired at the injection well and a monitoring well, flowing bottom-hole pressure data at the injection well, and time-lapse pressure measurements at several locations along the monitoring well. The history matching results indicate that the CO2 movement is mostly restricted to the intended zones of injection which is consistent with an independent warm-back analysis of the temperature data. In addition to employing simulation models and inverse methods for CO2 plume imaging, we also initialized a data-driven technology for detecting inter-well connectivity based on production and pressure data. Our machine-learning framework is built on the statistical recurrent unit (SRU) model and interprets well-based injection/production data into inter-well connectivity without relying on a geologic model. We test it on synthetic and field-scale CO2 EOR projects utilizing the water-alternating-gas (WAG) process. The validation of the proposed data-driven inter-well connectivity assessment is performed using synthetic data from simulation models where inter-well connectivity can be easily measured using the streamline-based flux allocation. The SRU model is shown to offer excellent prediction performance on the synthetic case. Despite significant measurement noise and frequent well shut-ins imposed in the field-scale case, the SRU model offers good prediction accuracy, the overall relative error of the phase production rates at most producers ranges from 10% to 30%. It is shown that the dominant connections identified by the data-driven method and streamline method are in close agreement. Texas A&M University, the lead organization in the project, was primarily responsible for the development of tomographic approaches for CO2 plume mapping in conjunction with distributed pressure, temperature and seismic onset time data. Battelle, as a subcontractor, was primarily responsible for the development of analytical and empirical methods for analyzing transient injection rate and pressure data from point/line sources such as injection and monitoring wells. An additional area of emphasis for Battelle was the use of machine learning for such tasks as inferring reservoir connectivity information from injection-production data, and identifying variable importance for machine learning-based proxy models developed from full-physics simulations. The two organizations also collaborated on the application of the tomographic inversion methodology for a field data set.

02 PETROLEUM↗

Virtual sensing-enabled digital twin framework for real-time monitoring of nuclear systems leveraging deep neural operators

Abstract Real-time monitoring is a foundation of nuclear digital twin technology, crucial for detecting material degradation and maintaining nuclear system integrity. Traditional physical sensor systems face limitations, particularly in measuring critical parameters in hard-to-reach or harsh environments, often resulting in incomplete data coverage. Machine learning-driven virtual sensors offer a transformative solution by complementing physical sensors in monitoring critical degradation indicators. This paper introduces the use of Deep Operator Networks (DeepONet) to predict key thermal-hydraulic parameters in the hot leg of pressurized water reactor. DeepONet acts as a virtual sensor, mapping operational inputs to spatially distributed system behaviors without requiring frequent retraining. Our results show that DeepONet achieves low mean squared and Relative L2 error, making predictions 1400 times faster than traditional CFD simulations . These characteristics enable DeepONet to function as a real-time virtual sensor, synchronizing with the physical system to track degradation conditions and provide insights within the digital twin framework for nuclear systems.

Hossain, Raisa↗

Steel Creek, Pen Branch, and D-Area Watershed Stream Gauging Stations

A network of stream gauging systems were installed in the Steel Creek, Pen Branch, D-Area Discharge Canal, and the D006 Stream in support of the groundwater modeling efforts for the P-Area Groundwater Operable Unit (OU); Chemical, Metals, and Pesticides (CMP) Pits OU; and the D-Area Watershed, respectively. Each location is monitored by a MACE Floseries3 FloPro data logger and a MACE doppler ultrasonic area/velocity sensor. Each stream gauging system is powered by an internal 12-volt battery supplied by a solar panel with a trickle charger. Information collected by each data logger is logged internally and telecommunicated via a cellular network to an online server for real time analysis and monitoring. The MACE doppler ultrasonic area/velocity sensor can measure stream depth and velocities to give output values of flow rates, total flow, net flow, and volumes. The water depth is measured by a ceramic pressure transducer located on the top of the sensor. The velocity is measured by a continuous wave doppler sensor to give an average velocity across the whole stream profile. This report discusses the equipment and methods used to install continuous stream gauging stations and provides a summary of data collected through FY2025.

54 ENVIRONMENTAL SCIENCES↗

Rock Physics-Based Data Assimilation of Integrated Continuous Active-Source Seismic and Pressure Monitoring Data during Geological Carbon Storage

Summary There has been substantial controversy concerning the role of geological carbon storage (GCS) in sequestering anthropogenic carbon emissions to mitigate climate change and global warming. Arguments center on the inability to monitor a geological storage site precisely and continuously, especially highlighting the associated costs and spatiotemporal trade-offs when using conventional subsurface monitoring techniques (well logs, core samples, chemical tracers, and 4D seismics). Active surveillance of GCS sites is essential for managing and mitigating potential leaks but is also required by regulation. With the goal of enhancing the monitoring capability at GCS sites, we present a rock physics-based joint data assimilation model to study a popular GCS site at Cranfield, Mississippi, USA. Synthetic continuous active-source seismic monitoring (CASSM) data (in the form of Vp and Qp measurements) and wellbore pressure monitoring data are assimilated with an ensemble of reservoir realizations to monitor gas saturation and reservoir pressure changes over a period of 100 years. Synthetic seismic attributes are generated using rock physics models (RPMs) and wellbore pressure monitoring data are extracted from the ground truth. Two assimilation methods, ensemble Kalman filter (EnKF) and ensemble Kalman smoother (EnKS), are tested in an observation system simulation experiment (OSSE) environment to assess the prediction accuracy of the individual and composite observation systems. The joint monitoring system achieves more accurate estimates of gas saturation and pressure, across the time span from start of injection to end of forecast, as compared to a single type of monitoring tool and irrespective of data assimilation algorithm choice. These results indicate that jointly assimilated data from two types of sensors (in this case, crosswell seismic and downhole pressure) may lead to a more risk-reducing monitoring design. One would expect that more data, vis-à-vis inclusion of a new sensor type, will improve the accuracy of any GCS monitoring system. However, from a practical standpoint, one important question is whether such a gain in accuracy is worth the additional cost associated with the new sensor. This paper focuses on quantifying the gain in accuracy, such that a practitioner can answer this question.

Engineering↗

Manufacturing control systems and logic for prognosis of defects in composite materials

Presented are manufacturing control systems for composite-material structures, methods for assembling/operating such systems, and transfer molding techniques for predicting and ameliorating void conditions in fiber-reinforced polymer panels. A method for forming a composite-material construction includes receiving a start signal indicating a fiber-based preform is inside a mold cavity, and transmitting a command signal to inject pressurized resin into the mold to induce resin flow within the mold cavity and impregnate the fiber-based preform. An electronic controller receives, from a distributed array of sensors attached to the mold, signals indicative of pressure and/or temperature at discrete locations on an interior face of the mold cavity. The controller determines a measurement deviation between a calibrated baseline value and the pressure and/or temperature values for each of the discrete locations. If any one of the respective measurement deviations exceeds a calibrated threshold, a void signal is generated to flag a detected void condition.

36 MATERIALS SCIENCE↗

Evaluation of measuring thermal conductivity of isotropic and anisotropic thermally insulating materials by transient plane source (Hot Disk) technique

The transient plane source (TPS) technique, also referred as the Hot Disk method, has been widely used due to its ability to measure the thermal properties of an extensive range of materials (solids, liquids, and powder). Recently, it has been recognized that typical Hot Disk sensors can influence TPS results of thermally insulating materials and lead to an overestimation of thermal conductivity. Although improvements have been proposed, they have not yet been implemented in the commercial TPS, leaving researchers with non-standardized modifications or options provided by a commercial Hot Disk apparatus. An empirical study of thermally insulating materials such as extruded polystyrene (XPS) and aerogel blanket is conducted in order to address the factors that affect the reliability of thermal conductivity k obtained using the commercial TPS apparatus. Sensor size, input power, duration of the measurements, applied pressure, and, in the case of anisotropic materials, heat capacity are investigated, and the results are compared with those using a Heat Flow Meter apparatus. The effect of sensor size on the k value is ascribed to heat loss through connecting leads and is more pronounced in smaller sensors and in materials with lower k values . In the case of XPS and aerogel, the effect becomes minimal for sensors with a radius r ≥ 6.4 mm. The low input power yields a high scattering of the results and should be avoided. Applied contact pressure and the tested region of the specimen play an important role in experiments with low-density fibrous materials due to the large percentage of heat being transferred by radiation and the heterogeneous nature of the samples, respectively. Additionally, the sensitivity of anisotropic measurements to the value of the material’s volumetric heat capacity ( ρC p ) is shown, emphasizing the need for the precise determination.

thermal conductivity↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

Optical Fiber Sensors Capable of Monitoring Hydrogen in the Subsurface Hydrogen Storage Environment

Subsurface hydrogen storage is a cost-effective and environmentally friendly storage option in a large quantity. Hydrogen would be stored in subsurface storage reservoirs at high temperature/pressure under very humid condition. Monitoring hydrogen concentration in those harsh storage environments is crucial to ensure the integrity and safety of the hydrogen storage infrastructure. Thus, this project focuses on the development of optical fiber hydrogen sensors capable of monitoring hydrogen in the harsh environments that are representative of underground storage conditions. The optical fiber hydrogen sensor developed at NETL consists of a palladium-based sensing film with a filter layer which minimizes the environmental impacts on hydrogen sensing. The developed sensor has demonstrated significant improvement on hydrogen sensing at 80℃ under high humidity condition (99% RH) without the baseline drift. The hydrogen sensor also showed negligible cross-sensitivity to CO2 and CH4 which would be present as a cushion gas inside the underground hydrogen storage reservoir. Moreover, the sensor has demonstrated the stable monitoring of hydrogen concentration at high pressure (1000 psi) and 80 ℃ in the presence of biological samples. The optical fiber hydrogen sensor developed would enable reliable monitoring of hydrogen concentration in subsurface hydrogen storage facilities.

Kim, Daejin↗

Temperature and Pressure Instrumentation for LYNM PE1 Chemical Explosive Testing

Underground chemical explosive testing has been conducted at the Nevada National Security Site under the Physics Experiment 1 (PE1) to validate explosive computer modeling and, ultimately, improve the accuracy of subsurface explosive detection. This SAND Report describes the dynamic temperature and pressure measurements within the chamber induced by the chemical explosive for the first of three experiments, PE1-A. The report details the instrumentation used for the experiment, the emplacement of the hardware, and the measured results. Dynamic temperature measurements were accomplished with the use of optical spectrometers and dynamic pressure was measured with a series of high-rated pressure transducers. This report includes details of the design and results of four cavity sensor systems used to measure early-time temperature, early-time pressure, late-time temperature, and late time pressure. The outcomes of PE1-A were used to inform the design of the remaining PE1 series experiments, PE1-B and PE1-DL.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Microbarograph - ESRL Hi-Res Microbarograph, Troutdale - Raw Data

High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

17 WIND ENERGY↗

Microbarograph - ESRL Hi-Res Microbarograph, Bonneville - Raw Data

High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

17 WIND ENERGY↗

Microbarograph - ESRL Hi-Res Microbarograph, Goldendale - Raw Data

High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

17 WIND ENERGY↗

Microbarograph - ESRL Hi-Res Microbarograph, Hood River - Raw Data

High-precision barometers (Paroscientific 6000-16B-IS) are combined with Nishiyama-Bedard Quad Disk pressure probes, measuring pressure (mb) at the surface, nominally 2 m above ground level. Data are sampled at 20 Hz for potential studies of turbulence. The sensors' high accuracy makes them useful for determining horizontal pressure gradients and their relation to wind ramp events, as well as the temporal variability of pressure associated with mountain wakes and waves. **Note different ASCII file formats for Goldendale (z04) and Walla Walla (z09) sites.**

17 WIND ENERGY↗