Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Spectroscopic Probe Molecule Selection Using Quantum Theory, First-Principles Calculations, and Machine Learning

Probe molecule vibrational spectra have a long history of being used to characterize materials including metals, oxides, metal-organic frameworks, and even human proteins. Furthermore, recent advances in machine learning have enabled computationally generated spectra to aid in detailed characterization of complex surfaces with probe molecules. Despite widespread use of probe molecules, the science of probe molecule selection is underdeveloped. Here, we develop physical concepts, including orbital interaction energy and the energy overlap integral, to explain and predict the ability of probe molecules to discriminate structural descriptors. We resolve the crystal orbital overlap population (COOP) to specific molecular orbitals and quantify their bonding character, which directly influences vibrational frequencies. Using only a single adsorbate calculation from density function theory (DFT), we compute the interaction energy of individual adsorbate molecular orbitals with adsorption site atomic orbitals across many different sites. Combining the molecular orbital resolved COOP and changes in orbital interaction energy enables probe molecule selection for improved discrimination of various sites. We demonstrate these concepts by comparing the predicted effectiveness of carbon monoxide (CO), nitric oxide (NO), and ethylene (C 2 H 4 ) to probe Pt adsorption sites. Finally, using a previously developed machine learning framework, we show that models trained on hundreds of thousand C 2 H 4 spectra, computed from DFT, which regress surface binding-type and generalized coordination number (GCN), outperform those trained using CO and NO spectra. Lastly, a python package, pDOS_overlap, for implementing the electron density based analysis on any combination of adsorbates and materials, is also made available.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Overview of Key Saturn Probe Mission Trades

Ongoing studies, performed at NASA/JPL over the past two years in support of NASA's SSE Roadmap activities, proved the feasibility of a NF class Saturn probe mission. I. This proposed mission could also provide a good opportunity for international collaboration with the proposed Cosmic Vision KRONOS mission: a) With ESA contributed probes (descent modules) on a NASA lead mission; b) Early 2017 launch could be a good programmatic option for ESA-CV/NASA-NF. II. A number of mission architectures could be suitable for this mission: a) Probe Relay based architecture with short flight time (approx. 6.3-7 years); b) DTE probe telecom based architecture with long flight time (-11 years), and low probe data rate, but with the probes decoupled from the carrier, allowing for polar trajectories I orbiter. This option may need technology development for telecom; c) Orbiter would likely impact mission cost over flyby, but would provide significantly higher science return. The Saturn probes mission is expected to be identified in NASA's New Frontiers AO. Thus, further studies are recommended to refine the most suitable architecture. International collaboration is started through the KRONOS proposal work; further collaborated studies will follow once KRONOS is selected in October under ESA's Cosmic Vision Program.

probes↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

X-59 Air Data Probe Calibration Wind Tunnel Test

NASA's aeronautical innovators are working with Lockheed Martin to design and build a supersonic X-plane, the X-59, under the the Low Boom Flight Demonstrator (LBFD) Project, that produces a gentle thump rather than a loud sonic boom. The plane will be used to collect human response data over select U.S. communities. The data from the X-59 test flights will be provided to U.S. and international regulators to potentially allow supersonic flight over land, drastically reducing travel time within the U.S. and around the world. Two wind tunnel tests were conducted in the NASA Glenn Research Center (GRC) 8- by 6-Foot Supersonic Wind Tunnel to calibrate the nose probe for the X-59. The probe was successfully tested and calibrated at 19 Mach numbers between Mach 0.25 and Mach 1.7. Most data were collected using continuous roll angle sweeps at a set Mach number and pitch angle. About 725 high quality data runs were recorded during testing to be used in the calibration of the probe. A backup nose probe was also run through the same test matrix as the primary probe. The probe will be the primary instrument for the flight test of the X-59 for determining angle of attack, angle of sideslip, airspeed, and pressure altitude of the aircraft in flight. Knowing the aircraft's speed and attitude is critical for flight safety and is also critical data for the Sonic Boom mission. Areas of interest for the test were sea level takeoff and landing at Mach 0.2, subsonic cruise at Mach 0.9, and supersonic cruise at Mach 1.4. During Phase I flight testing, the air data nose probe and air data system as a whole will be further calibrated in flight to account for additional installed effects of the airframe on the air data system.

X-59↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10-5 for the non-dimensional total pressure and 2.88 x 10-5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10 -5 for the non-dimensional total pressure and 2.88 x 10 -5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Wind Tunnel Test of A Scale Model of A Venus Probe to Determine Aeroacoustics Environment

The Zephyr probe for NASA’s DAVINCI project is being designed to fly to Venus and collect measurements to characterize the Venusian atmosphere while it descends towards the surface. Despite a slow descent speed as the probe approaches the surface, the very dense atmosphere means the vibro-acoustic environment that the probe must withstand could be very harsh. A wind tunnel test campaign was conducted to characterize the surface-pressure fluctuations (acoustics) on the external surface of the probe during the descent. The goal was to provide forcing functions for vibro-acoustic analysis of all instruments inside the probe. A 25% scale-model of the Zephyr probe was manufactured, instrumented with 18 microphones, and tested in two wind tunnels located in the Fluid Mechanics Lab at NASA Ames Research Center at velocities ranging from 13 m/s to 48 m/s. Trip strips were added to the model to ensure a turbulent boundary layer on the model. Microphones were located appropriately to provide spectra of pressure fluctuations in regions with different flow characteristics as well as for calculating various two-point statistics. The acoustic spectra measured in the wind tunnel tests were scaled up to flight-scale using the estimated flight trajectory information. Besides fluctuating surface-pressure measurements, hot-film velocity measurements as well as smoke-laser flow visualization were conducted to better understand the flow around the probe. Lastly, several different geometry configurations were tested to see whether any reduction in acoustic levels could be achieved, but none of the configurations that were tested offered significant improvements. The flow visualization showed 3 primary flow regimes on the model: an attached turbulent boundary layer on the front of the model, a region of separated flow upstream of the flared lip, and a large, separated wake at the rear of the model. The acoustic spectra generally show three different shapes corresponding to these flow regions, with the highest levels seen at the rear of the model, and directly in front of the drag plate. The scaled overall levels of pressure fluctuations were found to be high: in the range of 130dB to 155dB.

planetary probe↗

Pop-up Langmuir probe diagnostic in the water cooled divertor of Wendelstein 7-X

The design, development, and successful implementation of pop-up Langmuir probes installed in the water-cooled divertor of W7-X are described. The probes are controlled by drive coils (actuators) installed behind the divertor plates. These drive coils make use of the magnetic field in W7-X to move the probe tips into and out of the plasma. The drive coils were installed in the vacuum vessel after extensively testing the durability of the coils and analyzing the criteria for safe operation. The probe design is carefully tailored for each of the 36 probe tips in order to be suitable for the different magnetic field configurations used in W7-X and ensure that the probes do not present leading edges to the magnetic flux tubes. An electronic bridge circuit is used for measurement to compensate for the effects of signal propagation time on the long cable lengths used. The diagnostic is integrated with the segment control of W7-X for automated operation and control of the diagnostic. The evaluation of the results from the plasma operation is presented after accounting for appropriate sheath expansion for negative bias voltage on the probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches

Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 10 13 cm –3 , the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliability of double probe measurements in nanodusty plasmas

Abstract Nonthermal plasmas are attractive sources for nanoparticles synthesis, however, their plasma properties are notoriously difficult to assess due to the chemically reactive environment and high nanoparticle concentrations. Here, we are using a floating double probe to measure the plasma properties of a nanoparticle-forming argon:silane plasma. We demonstrate good stability of current–voltage characteristics over several minutes of operation. However, unexpectedly larger electron temperatures are measured with increasing the silane mole fraction. To test the validity of these results, we developed a zero-dimensional global model to investigate the effect of the presence of nanoparticles on the plasma properties. Using this model, we show that increasing particle concentration leads to an increasing electronegativity of the plasma, causing an increase of the reduced electric field. However, this causes only a moderate increase in mean electron energy, in contrast to the much larger increase measured by the double probe. We argue that these large electron temperatures are based on the fact that a double probe measures an ‘apparent’ electron temperature, which is defined by the negative inverse slope of the logarithm of the electron energy probability function (EEPF) at an energy corresponding to the probe’s floating potential. As the silane mole fraction is increased, the plasma becomes more electronegative and the probe’s floating potential moves closer to the plasma potential. Combined with the strong non-Maxwellian EEPF, this leads to the large apparent electron temperatures obtained by the probe. Thus, the apparent electron temperatures measured with the double probe do not follow the trends in mean electron energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Flux Detection Probe to Quantify Dynamic Groundwater-Surface Water Exchange in the Hyporheic Zone

A new probe was designed to quantify groundwater-surface water exchange in the hyporheic zone under dynamic stage condition. Current methods focus on either vertical pore water velocity or Darcy flux measurements. Both parameters must be understood to evaluate residence time and mass flux of constituents. Furthermore, most instruments are not well suited for monitoring instantaneous velocity or flux under dynamic exchange conditions. For this reason, the flux detection probe (FDP) was designed that employs electrogeophysical measurements to estimate in situ sediment porosity, which can be used to convert pore water velocity to Darcy flux. Dynamic pore water velocity is obtained by monitoring fluid conductivity and temperature along the FDP probe. Pressure sensors deployed at the top and bottom of the probe provide the additional information necessary to estimate vertical permeability. This study focuses on the use of a geophysical method to estimate pore water velocity, porosity, and permeability within a controlled soil column where simulated river water displaces simulated groundwater. The difference between probe derived and theoretical pore water velocity using natural tracers such as electrical conductivity and temperature was -4.9 and 3.9% for downward flow and 1.1 and 12.8% for upward flow, respectively. The difference in porosity calculated from mass and volume packed in the soil column and probe measure porosity ranged between -3.2% and 1.5%. Also, the calculated hydraulic conductivity differed from probe derived values by -8.9%.

54 ENVIRONMENTAL SCIENCES↗

Multi-modal dynamic radiography using short-pulse laser-generated probe beams

Radiography is an important tool for the interrogation of dynamic experiments in the fields of dynamic properties of materials, and in condensed matter, high explosive, and high-energy-density physics. Multi-modal radiography advances the hypothesis that combining the information delivered by multiple radiographic modalities can lead to more constrained (improved) “reconstruction” of the scene than can be obtained from a single probe. We identify four modalities: multi-probe, time sequence, multi-view, and multi-messenger. Multi-probe radiography is a promising candidate for a next-generation dynamic radiographic facility. High-energy X-rays are the most frequently used probe for dynamic radiography, although recent developments show the utility of proton (pRad), electron (eRad), and neutron probe beams. Because each probing species interacts with material in the radiographic scene through quantitatively different mechanisms, each returns independent information about the scene, which can add extra constraints to the reconstruction process. How to conduct detailed, quantitative “co-analysis” of multiple data streams remains an area of active research. Multi-beam, short-pulse, laser-generated probes offer sufficient dose, an appropriate spectrum, and appropriate spatio-temporal resolution to produce high-quality dynamic radiographs. This paper reports on technology development to advance the state of the art of multi-modal/multi-probe radiography and the pursuit of both deterministic and inferential (AI/ML assisted) co-analysis methodologies to produce more constrained reconstructions from multi-modal data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outer planet entry probe system study. Volume 1: Summary

General mission considerations and science prospectus, which are of a general nature that applies to several or all planetary applications, are presented. Five probe systems are defined: nominal Jupiter probe system, and Jupiter probe-dedicated alternative probe system, Jupiter spacecraft radiation-compatible alternative probe system, Saturn probe system, and Saturn probe applicability for Uranus. Parametric analysis is summarized for mission analysis of a general nature, and then for specific missions to Jupiter, Saturn, Uranus, and Neptune. The program is also discussed from the hardware availability viewpoint and the aspect of commonality.

Source record↗

Properties of the wake of small Langmuir probes on sounding rockets

Split Langmuir probes have been used to study the near wake of small Langmuir probes on sounding rockets. Experiments have been performed on two rocket flights using planar disk and cylindrical geometries, and the results are presented. Significant wake perturbations in plasma density and temperature were found due to the probe body itself, even though the probes were of the order of or smaller than the Debye length. The largest effects of the wake are seen in the electron collection characteristics of the probe. The wake of small probes show apparent magnetic field aligned structure, even though the probes were much smaller than the ion gyroradius. On one flight, a space charge potential large enough to substantially alter photoemission, -3.5 volts, was observed.

Bering, E. A.↗

Probe corrected far-field reconstruction from measurements on a cylinder: A novel formulation and efficient algorithm

A novel and numerically efficient method of far field evaluation from measurements taken on a cylinder is based on the representation of both the antenna and the probe fields as superpositions of plane waves. A system of two integral equations are established whose unknown functions are the azimuthal and elevation components of the antenna pattern and whose known terms are the set of measurement data taken with two different probes - the second probe in most practical instances being simply the same probe with a different geometrical orientation. The equations express the known data - for each angular position of the antenna under measurement - as the integrals of the products of the corresponding components of the unknown antenna and known probe patterns multiplied by a phase term. The convolutional nature of the integral equations makes their solutions straight-forward. If, as is virtually always the case, the probe is small or of moderate size so that the axis of rotation of the antenna mount is in the far field of the probe, the intervention of asymptotic techniques makes the solution numerically very efficient. The agreement of calculated and experimental patterns is excellent.

Borgiotti, G. V.↗

The infinite line pressure probe

The infinite line pressure probe provides a means for measuring high frequency fluctuating pressures in difficult environments. A properly designed infinite line probe does not resonate; thus its frequency response is not limited by acoustic resonance in the probe tubing, as in conventional probes. The characteristics of infinite line pressure probes are reviewed and some applications in turbine engine research are described. A probe with a flat-oval cross section, permitting a constant-impedance pressure transducer installation, is described. Techniques for predicting the frequency response of probes with both circular and flat-oval cross sections are also cited.

Englund, D. R.↗

Ram-wake effects on plasma current collection of the PIX 2 Langmuir probe

The Plasma Interaction Experiment 2 (PIX 2) Langmuir probe readings of the same polar magnetospheric regions taken on consecutive orbits showed occasional apparent densities as much as 10 times lower than the average, although each pass clearly showed density structures related to the day/night boundary. At other points in the orbit, Langmuir probe currents varied by as much as a factor of 20 on a time scale of minutes. The hypothesis is advanced that these apparent inconsistencies in Langmuir probe current are the results of the probe's orientation relative to the body of the spacecraft and the velocity vector. Theoretical studies predict a possible depletion in collected electron current by a factor of 100 in the wake. Experimental results from other spacecraft indicate that a wake electron depletion by a factor of 10 or so is realistic. This amount of depletion is consistent with the PIX 2 data if the spacecraft was rotating. Both the Sun sensor and temperature sensor data on PIX 2 show a complex variation consistent with rotation of the Langmuir probe into and out of the spacecraft wake on a time scale of minutes. Furthermore, Langmuir probe data taken when the probe was not in the spacecraft wake are consistent from orbit to orbit. This supports the interpretation that ram/wake effects may be the source of apparent discrepancies at other orientations.

Ferguson, D. C.↗

The infinite line pressure probe

The infinite line pressure probe provides a means for measuring high frequency fluctuating pressures in difficult environments. A properly designed infinite line probe does not resonate; thus its frequency response is not limited by acoustic resonance in the probe tubing, as in conventional probes. The characteristics of infinite line pressure probes are reviewed and some applications in turbine engine research are described. A probe with a flat-oval cross section, permitting a constant-impedance pressure transducer installation, is described. Techniques for predicting the frequency response of probes with both circular and flat-oval cross sections are also cited.

Englund, D. R.↗