Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Warm Unit Stand Analysis for Proton Improvement Project II

The Proton Improvement Project II, commonly referred to as PIP II, is a linear accelerator overhaul at Fermilab to eventually double the output of its existing proton beam to continue to be the leading force in high energy physics. The proton beam is created through a series of high frequency cryomodules that must be connected utilizing a combination of magnets and vacuum pumps to ensure the beam is properly aligned. A housing mechanism for the magnets and vacuum pumps (Warm Units) will be placed between the cryomodules for realignment and require multiple stages of 6 degree-of-freedom adjustment options, to ensure that the beam alignment can fit all realistic requirements. Extensive testing and design modifications on the Warm Unit stand was completed to confirm not only the strength of the unit in nominal configuration, but also at each possible adjustment orientation for each 6 degree-of-freedom option. Structural analysis was also completed for various unique loading conditions i ncluding transportation loading and confirming the unit satisfies international building code. Simultaneously, testing and design modifications were done to confirm that the frequency modes of the system resided outside of concern ranges, which is determined by Fermilab safety codes and is set to exceed 15 Hz. Design changes that simultaneously stiffen the system to raise the lowest frequency modes while expanding access for technicians and allow for easier fabrication were developed and implemented into the Warm Unit stand. Various relationships between the design changes and the overall vibrational patterns were also developed for future use and study as the rest of PIP II matures.

43 PARTICLE ACCELERATORS↗

Finite element analysis of the impact of beam heating mode in molten salt corrosion experiments employing simultaneous ion irradiation

Finite element analysis was used to investigate the temperature and stress profiles that develop in 316L stainless steel membranes being irradiated using different proton beam conditions in contact with a molten salt environment. It was shown that in addition to a nonuniform irradiation profile, a focused 2 MeV proton beam leads to very strong temperature and stress gradients in the membrane, introducing highly localized driving forces that complicate and even compromise the integrity and reliability of the experimental results of corrosion studies. Here, the use of a focused beam in corrosion studies can create experimental artifacts that may misrepresent the true corrosion behavior. In contrast, the use of a rastered beam is shown to distribute the protons and resulting radiation damage uniformly across the membrane face, and more importantly, results in temperature and stress profiles that are not only very uniform but are of much lower magnitude. The use of a rastered beam during molten salt corrosion experiments is therefore recommended to achieve uniform damage rates, thereby reducing both gradients and magnitudes of the temperature and stress distributions.

43 - PARTICLE ACCELERATORS↗

Feasibility of using crystal channeling for the beam loss mitigation in slow extraction at 8GeV

In the accelerator applications of slow extraction for High Energy Physics (HEP), one of the prime challenges is the mitigation of beam losses, which is becoming increasingly critical with the continuous rise in beam power. A significant breakthrough was achieved earlier at CERN through the successful deployment of proton beam channeling in a crystal at 400GeV, effectively diverting the beam away from extraction septa and offering new avenues for improving slow extraction efficiency. However, a crucial question remains whether this approach is still effective at lower and medium proton beam energies. In this paper, we present the promising results of the computer simulation studies of the septum shadowing at 8GeV for the Mu2e project slow extraction at Fermilab. In conclusion, across the wide range of beam parameters, the beam loss reduction is shown to range between 40% and factor of three.

43 PARTICLE ACCELERATORS↗

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Space Charge Driven Emittance Growth and the Effect of Octupoles in IOTA

The Integrable Optics Test Accelerator (IOTA) at Fermilab is a small machine dedicated to a broad frontier accelerator physics program. An important aspect of this program is to investigate the potential benefits of the resonance free tune spread achievable with integrable optics to store and accelerate high intensity proton beams for which space charge is significant. In this context, a good understanding of proton beam emittance growth and particle loss mechanisms is essential. Assuming nominal design parameters, simulations show that for a bunched beam, the bulk of emittance growth takes place immediately following injection, typically within tens of turns. We attempt to account for this growth using a simplified RMS mismatch theory; some of its limitations and possible improvements are briefly discussed. We then compare theoretical predictions to simulations performed using the PIC code pyORBIT. Further exploring ways to mitigate emittance growth and reduce particle loss, we compare two beam matching strategies: (1) matching at the injection point (2) matching at the center of the nonlinear (octupole) insertion region where $\beta_x = \beta_y$. To observe how nonlinearity affects emittance growth and whether it dominates growth due to mismatch, we track two different distributions. Finally, we explore the potential of using octupoles in a quasi-integrable configuration to mitigate growth using a variety of initial distributions both at reduced and full intensities.

43 PARTICLE ACCELERATORS↗

Laser-assisted high-energy proton pulse extraction for feasibility study of co-located muon source at the SNS

Here, we have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (μSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H - ) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam based on laser neutralization causes only 0.2% reduction of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neutron facilities, and thus the proposed method will result in negligible impact on the SNS operation. This paper describes the development of a fiber/solid-state hybrid laser system that has high flexibility of pulse structure and output power, initial experiments on laser neutralization of beam and separation of H 0 beam from the existing SNS accelerator beam line, conversion of H 0 to proton at the SNS linac dump, and measurement results of 30 ns/50 kHz proton pulses. This system conclusively demonstrates the feasibility of laser-based proton beam extraction to power a world-leading μSR facility at the SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancement of LANSCE accelerator facility as a 1-MW Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is considered to be a testbed for scientific understanding of material degradation in future nuclear fusion reactors (Zinkle and Moeslang, 2013; Summary Report on the FPNS Workshop, 2018; Pitcher et al., 2019). The primary mission of FPNS is to provide a damage rate in iron samples of 8-11 dpa/calendar year with He/dpa ratio of 10 appm in irradiation volume of 50 cm 3 or larger with irradiation temperature 300–1000 °C and flux gradient less than 20%/cm in the plane of the sample. The Los Alamos Neutron Science Center (LANSCE) is an attractive candidate for the FPNS project. The Accelerator Facility was designed and operated for an extended period as a 0.8-MW Meson Factory. The existing setup of the LANSCE accelerator complex can nearly fulfill requirements of the fusion neutron source station. The primary function of the upgraded accelerator systems is the safe and reliable delivery of a 1.25-mA continuous proton beam current at 800-MeV beam energy from the switchyard to the target assembly to create 1 MW power of proton beam interacting with a solid tungsten target. The present study describes existing accelerator setup and further development required to meet the needs of FPNS project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gigacycle Fatigue Strength Evaluation of Welded 316L Stainless Steels for Mercury Target Vessel

At the Materials and Life Science Experimental Facility (MLF) in J-PARC, liquid mercury target for the pulsed spallation neutron source is in operation. An enclosure vessel for the liquid mercury target made of type 316L stainless steel (SS316L) suffers two kinds of cyclic stress during operation. One is the thermal stress due to the internal heating and swings by proton beam trip. The other is the impulsive stress by the pressure waves generated by the proton beam injection. The total number of loading cycles for the former is ∼104, and the latter is ∼4 × 108 for a year operation in the J-PARC mercury target vessel. The target vessel is assembled by an electron beam welding (EBW) and a gas tungsten arc welding (GTAW). However, fatigue data of welded SS316L up to gigacycle is limited. Ultrasonic fatigue testing, applying load cycles by utilizing ultrasonic resonance, for the welded SS316L was performed to investigate the effect of welding on fatigue behavior up to a gigacycle. The result showed that the fatigue strength degradation by EBW and EBW with GTAW were not recognized up to 109 cycles. Crack initiation in welded specimens nucliated at off-center areas of the specimen whereas the cracks in base metal specimen originated at the specimen center.

Naoe, Takashi [Japan Atomic Energy Agency (JAEA)]↗

Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector

The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive techniques. The MI uses ionization profile monitors as its only profile system. An alternative technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. This type of device was installed in MI and initial studies of it have been previously presented. This paper will present the status and recent studies of the device utilizing different techniques.

43 PARTICLE ACCELERATORS↗

Progress on an Electron Beam Profile Monitor at the Fermilab Main Injector

The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam intensities in the Main Injector (MI) that will exceed 2 MW. Measuring the transverse profiles of these high intensity beams in a ring requires non-invasive techniques. The MI uses ionization profile monitors as its only profile system. An alternative technique involves measuring the deflection of a probe beam of electrons with a trajectory perpendicular to the proton beam. This type of device was installed in MI and initial studies of it have been previously presented. This paper will present the status and recent studies of the device utilizing different techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A skew quadrupole for the AGS to minimize the polarization losses of the polarized beams

The partial helices installed in the Alternating Gradient Synchrotron (AGS) 9 [1] eliminate both, the imperfection and the vertical intrinsic spin resonances thus yielding a 70% polarized proton beam with rigidity 79.4 [Tm] with 2x10 11 protons/bunch at the end of the AGS acceleration cycle. The initial beam polarization at the exit of the 200 MeV Linac is measured to be 80%. The 10% loss of the polarization at the end of the AGS acceleration cycle is due to the horizontal spin resonances which are caused by the betatron oscillations of the beam in the presence of the partial helices. To reduce the effect of these horizontal spin resonances on the beam polarization, the “jump Quads method” is applied in the AGS [2] which eliminates, almost all, the horizontal spin resonances and increases the final polarization of the proton beam to the value of 70%. A study [3] shows that these horizontal spin resonances can be totally eliminated by introducing into the AGS ring, skew quadrupoles which linearly couple the beam motions to excite new horizontal spin resonances which minimize the horizontal-spin-resonances caused by the partial-helices.

43 PARTICLE ACCELERATORS↗

A Compact Gas Liquid Separator for the Spallation Neutron Source Mercury Process Loop

Upgrades at the spallation neutron source (SNS) accelerator at Oak Ridge National Laboratory are underway to double its proton beam power from 1.4 to 2.8 MW. About 2 MW will go to the current first station while the rest will go to the future Second Target Station. The increase of beam power to the first target station is especially challenging for its mercury target. When the short proton beam hits the target, strong pressure waves are generated, causing cavitation erosion and challenging stresses for the target's weld regions. SNS has successfully operated reliably at 1.4 MW by mitigating the pressure wave with the injection of small Helium bubbles into the mercury. To operate reliably at 2 MW, more gas will be injected into mercury to mitigate the pressure wave further. However, the mercury process loop was not originally designed for gas injection, and the accumulation of gas in the pipes is a concern. Due to space constraints, a custom gas liquid separator (GLS) was designed to fit a 90-deg horizontal elbow space in the SNS mercury loop. Simulations and experiments were performed, and a successful design was developed that has the desired efficiency while keeping the pressure losses acceptable.

42 ENGINEERING↗

A Dedicated Muon EDM Experiment in the `g-2 Storage Ring

Spin precession experiments offer exciting motivations to search for new physics. We propose here an idea of using a modified version of the Muon g-2 storage ring for a potential new scientific program to search for a non-zero muon electric dipole moment (EDM). Using both electric and magnetic dipole fields to produce a "frozen spin" condition for the MDM (all the while enhancing the EDM spin precession), the storage ring would operate at a lower central muon momentum than for the present Muon g-2 measurement. The incident proton beam on target for the muon production can be obtained from the PIP-II high intensity proton beam. Preliminary calculations and simulation results of muon production at 800 MeV PoT, along with the determination of the closed orbit inside the hybrid 'g-2' storage ring configuration, shall be presented. Possibilities of using the 'g-2' storage ring as a test bench to demonstrate the freezing of the MDM spin precession shall be discussed. The operational range of the muon's momentum and energy, and their respective window of electric and magnetic field values to establish the frozen spin condition, shall be presented. We shall also briefly discuss the physics prospects and improvements in muon EDM bounds upon using Fermilab's PIP-II beam.

Narayanan, Aakaash [Fermilab] (ORCID:0000000157944↗

A Dedicated Muon EDM Experiment in the `g-2 Storage Ring

Spin precession experiments offer exciting motivations to search for new physics. We propose here an idea of using a modified version of the Muon g-2 storage ring for a potential new scientific program to search for a non-zero muon electric dipole moment (EDM). Using both electric and magnetic dipole fields to produce a "frozen spin" condition for the MDM (all the while enhancing the EDM spin precession), the storage ring would operate at a lower central muon momentum than for the present Muon g-2 measurement. The incident proton beam on target for the muon production can be obtained from the PIP-II high intensity proton beam. Preliminary calculations and simulation results of muon production at 800 MeV PoT, along with the determination of the closed orbit inside the hybrid 'g-2' storage ring configuration, shall be presented. Possibilities of using the 'g-2' storage ring as a test bench to demonstrate the freezing of the MDM spin precession shall be discussed. The operational range of the muon's momentum and energy, and their respective window of electric and magnetic field values to establish the frozen spin condition, shall be presented. We shall also briefly discuss the physics prospects and improvements in muon EDM bounds upon using Fermilab's PIP-II beam.

Narayanan, Aakaash [Fermilab] (ORCID:0000000157944↗

PIP-II Particle Accelerator Project

The PIP-II project is an essential upgrade of Fermilab’s particle accelerator complex. Groundbreaking occurred in March 2019. The upgrade will enable Fermilab’s accelerators to generate an unprecedented stream of neutrinos—subtle, subatomic particles that could hold the key to understanding the universe’s evolution—by creating the world’s most intense high-energy neutrino beams. This capability positions Fermilab to be the world leader in accelerator-based neutrino research. It enables the scientific program for the international, Fermilab-hosted Deep Underground Neutrino Experiment (DUNE) and Long-Baseline Neutrino Facility (LBNF). The key to PIP-II is power. When the PIP-II project is complete, Fermilab will be able to generate proton beams greater than 1 megawatt—60 percent higher than current capabilities. These powerful beams of protons will in turn create intense beams of neutrinos. Future PIP-II upgrades will triple the lab’s current beam power. PIP-II’s high-intensity proton beams will provide a flexible platform for the long-term future of the Fermilab accelerator complex and the U.S. accelerator-based particle physics program.

Fermilab, Fermilab↗

Neutrino oscillation prospects with a dual-baseline beam from BNL to SNOLAB and SURF

The Electron-Ion Collider (EIC) is a next-generation accelerator primarily designed to study the internal structure of nucleons through high-precision electron-hadron collisions. In this work, we explore the feasibility of employing a 1 MW fraction of the EIC proton beam to generate a high-intensity GeV-scale neutrino beam for long-baseline oscillation studies. We have simulated proton-target interactions and optimize the resulting neutrino fluxes for water-based liquid scintillator (WbLS) detectors located at distinct baselines of 900 km and at 2900 km. Oscillation analyses performed with GLoBES show that extended baselines allow access to multiple oscillation maxima, significantly enhancing sensitivity to leptonic CP violation. The study also examines the interplay between matter effects and the intrinsic CP violating phase in shaping observable asymmetries. We note that simplified systematics and no backgrounds are used in this analysis to establish the baseline physics potential. These results suggest that the EIC proton beam could provide a novel and complementary source for precision neutrino physics, extending the scientific reach of the EIC program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton irradiation of simple gas mixtures: Influence of irradiation parameters

In order to get information about the influence of irradiation parameters on radiolysis processes of astrophysical interest, methane gas targets were irradiated with 6.5 MeV protons at a pressure of 1 bar and room temperature. Yields of higher hydrocarbons like ethane or propane were found by analysis of irradiated gas samples using gas chromatography. The handling of the proton beam was of great experimental importance for determining the irradiation parameters. In a series of experiments current density of the proton beam and total absorbed energy were shown to have a large influence on the yields of produced hydrocarbons. Mechanistic interpretations of the results are given and conclusions are drawn with regard to the chemistry and the simulation of various astrophysical systems.

Sack, Norbert J.↗