Search NASA⌕ Search

SEARCH · Search NASA

Results for “proton transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Nuclear emulsion measurements of the astronauts' radiation exposure on the Apollo-Soyuz mission

On the Apollo-Soyuz mission each astronaut carried one passive dosimeter containing nuclear photographic emulsions, plastic foils, TLD chips, and neutron-activation foils for recording radiation exposure. This report is limited to the presentation of data retrieved from nuclear emulsions. Protons, most of them trapped particles encountered in numerous passes through the South Atlantic Anomaly, contributed by far the largest share to the mission dose. Their linear energy transfer (LET) spectrum was established from track and grain counts in a G.5 emulsion which is used for medium and high energies, and from ender counts in a K.2 emulsion which is used for low energies. The total mission fluence of protons was found to be equivalent to a unidirectional beam of 448,500 square centimeters. The broad spectrum was broken down into small LET intervals, which allowed for the computation of absorbed doses and dose equivalents. The totals are 51 millirad and 74 millirem. Counts of disintegration stars in K.2 emulsion are incomplete at present. While a total of 467 stars were identified, counting their prong numbers is still in progress. It was concluded that the Apollo-Soyuz astronauts' radiation exposure as such did not contain anything out of the ordinary that would seem to require special attention.

Schaefer, H. J.↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Ion Transmission to the Focal Plane of the Chandra X-Ray Observatory

The severe degradation in spectrometric performance observed by the AXAF CCD Imaging Spectrometer (ACIS) instrument on-board the Chandra X-ray Observatory (CXO) was associated with a sharp increase in charge transfer inefficiency combined with relatively constant dark current. It was also observed that damage occurred only during passage through the earth's radiation belts, and only when ACIS remained in the focal plane during the passage. Subsequent measurements and analyses support the conjecture that the damaging radiation entered through the Observatory's High-Resolution Mirror Assembly (HRMA) aperture. A mechanism whereby low energy magnetospheric protons and/or heavier ions are scattered through the HRMA and reach the focal plane with just enough energy to stop in the CCD's charge transfer region currently provides a reasonably consistent explanation of all observed phenomena. In this paper, we will describe analyses which support this conclusion. Simulations using standard ion transmission codes were used to generate a bi-directional response function (BDRF) for the mirror surfaces and transmission through the various path elements. The BDRF was convolved with the geometry via ray-trace. Damage estimates using measured proton fluence and ground measurements of ACIS- type CCD damage vs. proton energy will be presented and compared with observed on- orbit damage.

Kolodziejczak, J. J.↗

A simple parameterization for quality factor as a function of linear energy transfer

The paper presents a simple analytic approximation of the radiation quality factor (Q) as a function of linear energy transfer for use in radiation protection calculations. The paper also presents estimated quality factors in water for protons over a broad range of incident energies. It is shown that the quality factors are less than unity for all proton energies greater than 13 MeV.

Townsend, Lawrence W.↗

Space radiation dosimetry on US and Soviet manned missions

Radiation measurements obtained on board U.S. and Soviet spacecraft are presented and discussed. A considerable amount of data has now been collected and analyzed from measurements with a variety of detector types in low-Earth orbit. The objectives of these measurements have been to investigate the dose and Linear Energy Transfer (LET) spectra within the complex shielding of large spacecraft. The shielding modifies the external radiation (trapped protons, electrons, cosmic ray nuclei) which, in turn, is quite dependent on orbital parameters (altitude, inclination). For manned flights, these measurements provide a crew exposure record and a data base for future spacecraft design and flight planning. For the scientific community they provide useful information for planning and analyzing data from experiments with high sensitivity to radiation. In this paper, results of measurements by both passive and active detectors are described. High-LET spectra measurements were obtained by means of plastic nuclear track detectors (PNTD's) while thermoluminescent dosimeters (TLD's) measured the dose.

Parnell, T. A.↗

Large-angle p-d scattering at 580 Mev

Proton-deuteron elastic large angle scattering cross sections, noting backward peak consistent with baryon exchange mechanism with resonance transfer

Boschitz, E. T.↗

Ices in planetary rings

Understanding the structure and behavior of Saturnian rings in terms of properties of ices is basic for evolutionary planetology. The available information indicates the presence of quite pure, probably amorphous water ice in the form of medium-grained frost in a fairy castle structure with a low thermal inertia. Tidal forces and interparticle collisions lead to continuous break-up and re-formation of loose aggregates of smaller particles. Micrometeoroid bombardment and proton irradiation are important for explaining the mechanical and optical properties of the surfaces of ring particles. The transfer of angular momentum and mass among the rings should homogenize the chemical and structural characteristics of the ring ices. Uranian rings may be made of carbon-covered methane ice particles.

Smoluchowski, R.↗

Managing Radiation Degradation of CCDs on the Chandra X-ray Observatory

The CCDs on the Chandra X ray Observatory are sensitive to radiation damage particularly from low-energy protons scattering off the telescope's mirrors onto the focal plane. In its highly elliptical orbit, Chandra passes through a spatially and temporally varying radiation environment, ranging from the radiation belts to the solar wind. Translating thc Advanced CCD Imaging Spectrometer (ACIS) out of the focal position during radiation-belt passages has prevented loss of scientific utility and eventually functionality. However, carefully managing the radiation damage during the remainder of the orbit, without unnecessarily sacrificing observing time, is essential to optimizing the scientific value of this exceptional observatory throughout its planned 10-year mission. In working toward this optimization, the Chandra team developed aid applied radiation-management strategies. These strategies include autonomous instrument safing triggered by the on-board radiation monitor, as well as monitoring, alerts, and intervention based upon real-time space-environment data from NOAA and NASA spacecraft. Furthermore, because Chandra often spends much of its orbit out of the solar wind (in the Earth's outer magnetosphere and magnetosheath), the team developed the Chandra Radiation Model to describe the complete low-energy-proton environment. Management of the radiation damage has thus far succeeded in limiting degradation of the charge-transfer inefficiency (CTI) to less than 4.4*10^-6 and 1.4*10^-6 per year for the front-illuminated and back-illuminated CCDs, respectively.

ODell, Stephen L.↗

Radiation dosimetry measurements during U.S. Space Shuttle missions with the RME-III

Time-resolved radiation dosimetry measurements inside the crew compartment have been made during recent Shuttle missions with the U.S. Air Force Radiation Monitoring Equipment-III (RME-III), a portable battery-powered four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. Half of the missions had orbital inclinations of 28.5 degrees with the remainder at inclinations of 57 degrees or greater; altitudes ranged from 300 to 600 km. The determined dose equivalent rates ranged from 70 to 5300 microSv/day. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicles. Measurements indicate that medium- and high-LET particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Isocontours of fluence, dose and dose equivalent rate have been developed from measurements made during the STS-28 mission. The drift rate of the South Atlantic Anomaly is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and GCR dose for the STS-28 mission was significantly lower than the measured values.

STS-28 Shuttle Project↗

Modulational and decay instabilities of Alfven waves - Effects of streaming He(2+)

The parametric instability of a circularly polarized Alfven wave propagating along the background magnetic field are considered, with emphasis on the effects of a second ion species, He(2+), which drifts relative to the protons. Even though its abundance is small, the He(2+) modifies the dispersion relation of the 'pump' Alfven wave and introduces a new sound wave (alpha sound) in addition to the usual sound wave carried primarily by the electrons and protons. Instabilities which are close to the He(2+) gyroresonance are found. This may provide a means of directly transferring Alfven wave energy to the alpha particles, if the alphas are able to resonantly extract energy from the unstable waves without quenching the instability altogether. Instabilities which are close to the alpha particle sound speed are also found.

Hollweg, Joseph V.↗

Proton radiation effects on multi-pinned-phased CCDs

Three Tektronix 1024 x 1024 multi-pinned-phased (MPP) charge coupled devices were irradiated with protons to obtain data on CCD performance degradation in a proton radiation environment. The devices were irradiated with a spectrum of energies up to 120 MeV, simulating the total radiation dose of a long-term space experiment. Basic parameters such as charge transfer efficiency, dark current, noise, and full well were measured before and after irradiation. A test was also performed to determine the effectiveness of various thicknesses of tantalum shielding in protecting the CCD from damage. Dark current increase and CTE degradation were the most noticeable effects of proton radiation. This paper will present the objectives, test data, and conclusions of the proton testing, and will identify future testing to be performed.

Murata-Seawalt, D.↗

Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

Mir Project↗

A comparison of quality factors and weighting factors for characterizing astronaut radiation exposures

Radiation exposures are typically characterized by two quantities. The first is the absorbed dose, or the energy deposited per unit mass for specific types of radiation passing through specified materials. The same amount of energy deposited in material by two different types of radiation, however, can result in two different levels of risk. Because of this, for the purpose of radiation protection operations, absorbed dose is modified by a second factor intended to normalize the risk associated with a given exposure. We present here an inter-comparison of methods for this modification. First is the radiation quality factor (Q), as defined by ICRP publication 60. This quantity is related functionally to the unrestricted linear energy transfer (LET) of a given radiation, and is multiplied by the absorbed dose to derive the dose equivalent (H). The second method for modifying absorbed dose is the radiation weighting factor, also given in ICRP-60, or as modified in NCRP report 115. To implement the weighting factor, the absorbed dose resulting from incidence of a particular radiation is multiplied by a factor assigned to that type of radiation, giving the equivalent dose. We compare calculations done based on identical fields of radiation representative of that encountered by the MIR space station, applying each of these two methods. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Proton-deuteron double scattering

A simple but accurate form for the proton-deuteron elastic double scattering amplitude, which includes both projectile and target recoil motion and is applicable at all momentum transfer, is derived by taking advantage of the restricted range of Fermi momentum allowed by the deuteron wave function. This amplitude can be directly compared to approximations which have neglected target recoil or are limited to small momentum transfer; the target recoil and large momentum transfer effects are evaluated explicitly within the context of a Gaussian model.

Wilson, J. W.↗

Accreting X-ray pulsar atmospheres heated by Coulomb deceleration of protons

Results are presented from detailed self-consistent models of accreting magnetized neutron star atmospheres, heated by the gradual deceleration of infalling protons via Coulomb encounters. The temperature and density gradients are calculated assuming momentum and energy balance, coupled with the radiative transfer for two polarizations. The cyclotron resonance effects were treated approximately. These models are characterized by power-law energy spectra, with single pulses at higher frequencies and multiple pulses at lower ones for some aspect angles, as well as a phase-dependent spectral index.

Meszaros, P.↗

Radiation measurements in low Earth orbit: U.S. and Russian results

The radiation environment in low-Earth orbital flights is complex. It is strongly influenced by altitude, orbital inclination, time within a given solar cycle, flight duration, and shielding configuration. At any specified shielded location, both primary and secondary particles generated by nuclear interactions of primary particles with spacecraft structure are present. In addition, there are atmospheric secondary albedo protons and neutrons. No single detector can adequately measure this complex radiation field, and measurements of very high linear energy transfer target fragmentation products are particularly difficult. Crew radiation exposure have exclusively been measured using passive thermoluminescent detectors (TLDs). The cosmonaut exposures on the Mir station, uncorrected for the TLD inefficiency and neutron contribution, have varied from a low of 2.43 cGy to a high of 8.70 cGy. These correspond to dose rates of 144 microGy d(-1) to 468 microGy d(-1). These are consistent with rates observed by the D2 ion-chamber. Using the rates measured by the D1 chamber, dose rates under 4 cm of water vary from about 60 microGy d-1 to about 350 microGy d(-1). There is variation of about a factor of two between the dose rates at various locations in the same module. There is also a variation of dose rates of about a factor two between various modules. The highest astronaut dose for a Shuttle flight (STS-82) was 3.205 cGy with a dose rate of 3,221 microGy d(-1). Neutron contribution could be 36 +/- 15% of the astronaut charged particle dose equivalent. East-West asymmetry of dose rate is significant for spacecrafts that fly in an fixed altitude, such as the International Space Station.

NASA Center JSC↗