Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse analysis measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A comparison of lightning and nuclear electromagnetic pulse response of tactical shelters

The internal response (electromagnetic fields and cable responses) of tactical shelters is addressed. Tactical shelters are usually well-shielded systems. Apart from penetrations by signal and power lines, the main leakage paths to the interior are via seams and the environment control unit (ECU) honeycomb filter. The time domain in three-dimensional finite-difference technique is employed to determine the external and internal coupling to a shelter excited by nuclear electromagnetic pulses (NEMP) and attached lightning. The responses of interest are the internal electromagnetic fields and the voltage, current, power, and energy coupled to internal cables. Leakage through the seams and ECU filter is accomplished by their transfer impedances which relate internal electric fields to external current densities. Transfer impedances which were experimentally measured are used in the analysis. The internal numerical results are favorably compared to actual shelter test data under simulated NEMP illumination.

Perala, R. A.↗

Stereo viewing 3-component, planar PIV utilizing fuzzy inference

An all electronic 3-D Digital Particle Image Velocimetry (DPIV) system has been developed for use in high velocity (supersonic) flows. Two high resolution CCD cameras mounted in a stereo viewing configuration are used to determine the out-of-plane velocity component from the difference of the in-plane velocity measurements. Double exposure image frames are acquired and Fuzzy inference techniques are used to maximize the validity of the velocity estimates obtained from the auto-correlation analysis. The CCD cameras are tilted relative to their respective lens axes to satisfy Scheimpflug's condition. Tilting the camera film plane ensures that the entire image plane is in focus. Perspective distortion still results, but can be corrected by proper calibration of the optical system. A calibration fixture is used to determine the experimental setup parameters and to assess the accuracy to which the z-plane displacements can be estimated. The details of the calibration fixture and procedure are discussed in the text. A pair of pulsed Nd:YAG lasers operating at 532 nm are used to illuminate the seeded flow from a convergent nozzle operated in an underexpanded condition. The light sheet was oriented perpendicular to the nozzle flow, yielding planar cross-sections of the 3-component velocity field at several axial stations. The key features of the supersonic jet are readily observed in the cross-plane vector plots.

Wernet, Mark P.↗

Thermal Field Imaging Using Ultrasound

It is often desirable to be able to determine the temperature field in the interiors of opaque fluids forced into convection by externally imposed temperature gradients. To measure the temperature at a point in an opaque fluid in the usual fashion requires insertion of a probe, and to determine the full field therefore requires either the ability to move this probe or the introduction of multiple probes. Neither of these solutions is particularly satisfactory, although they can lead to quite accurate measurements. As an alternative we have investigated the use of ultrasound as a relatively non-intrusive probe of the temperature field in convecting opaque fluids. The temperature dependence of the sound velocity can be sufficiently great to permit a determination of the temperature from timing the traversal of an ultrasound pulse across a chamber. In this paper we will present our results on convecting flows of transparent and opaque fluids. Our experimental cells consist of relatively narrow rectangular cavities made of thermally insulating materials on the sides, and metal top and bottom plates. The ultrasound transducer is powered by a pulser/receiver, the signal output of which goes to a very high speed signal averager. The average of several hundred to several thousand signals is then sent to a computer for storage and analysis. The experimental procedure is to establish a convective flow by imposing a vertical temperature gradient on the chamber, and then to measure, at several regularly spaced locations, the transit time for an ultrasound pulse to traverse the chamber horizontally (parallel to the convecting rolls) and return to the transducer. The transit time is related to the temperature of the fluid through which the sound pulse travels. Knowing the relationship between transit time and temperature (determined in a separate experiment), we can extract the average temperature across the chamber at that location. By changing the location of the transducer it is then possible to find the average temperature at different locations along the chamber, thereby determining the temperature profile along the system. (In the future we will construct an array of transducers. This will give us the capability to determine the temperature profile much more rapidly than at present, an important consideration if time-dependent phenomena are to be studied.) To validate our procedure we introduced encapsulated liquid crystal particles into glycerol. The liquid crystal particles' color varies depending on the temperature of the fluid. A photograph of the fluid through transparent sidewalls therefore gives a picture of the temperature field of the convecting fluid, independent of our ultrasound imaging. A representative result is shown in the Figure 1, which reveals a very satisfying correspondence between the two techniques. Therefore we have a great deal of confidence that the ultrasound imaging approach is indeed measuring the actual temperature profile of the fluid. The technique has also been applied to convecting liquid metal flows, and representative data will be presented from those experiments as well.

Andereck, D.↗

Global Monitoring of Clouds and Aerosols Using a Network of Micro-Pulse Lidar Systems

Long-term global radiation programs, such as AERONET and BSRN, have shown success in monitoring column averaged cloud and aerosol optical properties. Little attention has been focused on global measurements of vertically resolved optical properties. Lidar systems are the preferred instrument for such measurements. However, global usage of lidar systems has not been achieved because of limits imposed by older systems that were large, expensive, and logistically difficult to use in the field. Small, eye-safe, and autonomous lidar systems are now currently available and overcome problems associated with older systems. The first such lidar to be developed is the Micro-pulse lidar System (MPL). The MPL has proven to be useful in the field because it can be automated, runs continuously (day and night), is eye-safe, can easily be transported and set up, and has a small field-of-view which removes multiple scattering concerns. We have developed successful protocols to operate and calibrate MPL systems. We have also developed a data analysis algorithm that produces data products such as cloud and aerosol layer heights, optical depths, extinction profiles, and the extinction-backscatter ratio. The algorithm minimizes the use of a priori assumptions and also produces error bars for all data products. Here we present an overview of our MPL protocols and data analysis techniques. We also discuss the ongoing construction of a global MPL network in conjunction with the AERONET program. Finally, we present some early results from the MPL network.

Welton, Ellsworth J.↗

Biotelemeters for Space Flights and Fetal Monitoring

Pill-shaped biotelemeters originally designed for space flight applications will soon be used for monitoring the health of a fetus during and after in-utero fetal surgery. The authors developed a family of biotelemeters that are not only small enough for rodent studies on board the space shuttle or international space station, but also fit through a 10 mm trocar, a plastic tube that is used in endoscopic fetal surgery to obtain minimally invasive access to the fetus. The first 'pill' measures pressure and temperature, and is currently undergoing long-term leakage and biocompatibility tests. A second pill under development measures pH and temperature. A prototype of the 'pH-pill' has been built and successfully tested and is presently being miniaturized into the same dimensions as the 'pressure pill'. Additional pills measuring heart rate, ECG, other ions such as calcium and potassium, and eventually glucose and blood gases, will follow. All pills are designed for ultra-low power consumption yielding lifetimes of up to 10 months in order to meet the requirements of fetal monitoring, but also to provide the capability of long-term space station experiments. Each pill transmits its pulse-interval-modulated signal on a unique carrier frequency in the frequency range of 174-216MHz. A custom-designed multi-channel receiver demodulates and decodes each pill signal and sends the data to a LabVIEW program that performs real-time data analysis and display. A patent for the pill family and its data analysis system is pending.

Mundt, Carsten W.↗

Micro-Pulse Lidar Signals: Uncertainty Analysis

Micro-pulse lidar (MPL) systems are small, autonomous, eye-safe lidars used for continuous observations of the vertical distribution of cloud and aerosol layers. Since the construction of the first MPL in 1993, procedures have been developed to correct for various instrument effects present in MPL signals. The primary instrument effects include afterpulse, laser-detector cross-talk, and overlap, poor near-range (less than 6 km) focusing. The accurate correction of both afterpulse and overlap effects are required to study both clouds and aerosols. Furthermore, the outgoing energy of the laser pulses and the statistical uncertainty of the MPL detector must also be correctly determined in order to assess the accuracy of MPL observations. The uncertainties associated with the afterpulse, overlap, pulse energy, detector noise, and all remaining quantities affecting measured MPL signals, are determined in this study. The uncertainties are propagated through the entire MPL correction process to give a net uncertainty on the final corrected MPL signal. The results show that in the near range, the overlap uncertainty dominates. At altitudes above the overlap region, the dominant source of uncertainty is caused by uncertainty in the pulse energy. However, if the laser energy is low, then during mid-day, high solar background levels can significantly reduce the signal-to-noise of the detector. In such a case, the statistical uncertainty of the detector count rate becomes dominant at altitudes above the overlap region.

Welton, Ellsworth J.↗

Receiver Signal to Noise Ratios for IPDA Lidars Using Sine-wave and Pulsed Laser Modulation and Direct Detections

Integrated path differential absorption (IPDA) lidar can be used to remotely measure the column density of gases in the path to a scattering target [1]. The total column gas molecular density can be derived from the ratio of the laser echo signal power with the laser wavelength on the gas absorption line (on-line) to that off the line (off-line). 80th coherent detection and direct detection IPDA lidar have been used successfully in the past in horizontal path and airborne remote sensing measurements. However, for space based measurements, the signal propagation losses are often orders of magnitude higher and it is important to use the most efficient laser modulation and detection technique to minimize the average laser power and the electrical power from the spacecraft. This paper gives an analysis the receiver signal to noise ratio (SNR) of several laser modulation and detection techniques versus the average received laser power under similar operation environments. Coherent detection [2] can give the best receiver performance when the local oscillator laser is relatively strong and the heterodyne mixing losses are negligible. Coherent detection has a high signal gain and a very narrow bandwidth for the background light and detector dark noise. However, coherent detection must maintain a high degree of coherence between the local oscillator laser and the received signal in both temporal and spatial modes. This often results in a high system complexity and low overall measurement efficiency. For measurements through atmosphere the coherence diameter of the received signal also limits the useful size of the receiver telescope. Direct detection IPDA lidars are simpler to build and have fewer constraints on the transmitter and receiver components. They can use much larger size 'photon-bucket' type telescopes to reduce the demands on the laser transmitter. Here we consider the two most widely used direct detection IPDA lidar techniques. The first technique uses two CW seeder lasers, one on-line and one offline that are intensity modulated by two different frequency sine-waves signals before being amplified by a common laser amplifier. The receiver uses narrowband amplitude demodulation, or lock-in, Signal processing at the given laser modulation frequencies [3,4]. The laser transmitter operates in a quasi CW mode with the peak power equal to twice the average power. The on-line and off-line lasers can be transmitted at the same time without interference. Another direct detection technique uses a low duty cycle pulsed laser modulation [5,6] with the laser wavelengths alternating between on-line and off-line on successive pulses. The receiver uses time resolved detection and can also provide simultaneous target range measurement. With a lower laser duty cycle it requires a much higher peak laser power for the same average power.

Sun, Xiaoli↗

Time-domain sensitivity enhancement in pulsed Pb-TDL gas monitors

A Pb-salt tunable diode laser (TDL) has found many applications in the field of atmospheric gas analysis. Its continuous tunablility and fine spectral purity in the mid infrared region are outstanding from other lasers. The only shortcoming is that it requires cryogenic operating temperatures, though, it is improved year by year towards the room temperature operation. A repeated pulse operation of Pb salt diode lasers is possible with a thermoelectric cooling device, which allows an instrument a portable geometry disusing a heavy, bulky and power consuming mechanical refrigerator. A derivative spectrometry was exploiting the quick tunability of Pb salt diode lasers, though they are continuous wave (cw) operated with refrigerator or liquid nitrogen so far. A new system for derivative spectrometry with a pulsed diode laser will extend its field of applications because of reduced weights and size of measuring instruments. A preliminary results is shown that demonstrates the feasibility of an attempt to implement the derivative spectrmetry with repeatedly pulse driven diode lasers. Atmospheric methane was measured with 8 ppm/m sensitivity. Further results of parametric optimization for the best signal to noise ratios under any given device characteristics as well as for available real devices is given.

Koga, R.↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗

Development of a Rayleigh scattering system for temperature measurements in combustor flows

A dual line laser induced Rayleigh scattering system has been developed to be used in high temperature gas flows such as in combustors, and preliminary tests have been performed in a hot air jet. The qualification measurements included the collection and analysis of Rayleigh signal for time-resolved gas temperature over the two lines of a copper-vapor laser. The dual line signal collection technique is a feature to be used in detecting and discriminating the surface scattered laser light in the Rayleigh signal. Optical fibers are used to transmit the laser beam to the optical probe bench and to carry the collected signal from the bench to the housing of the signal sensors. Incident laser intensity at the probe volume is measured for both lines at each pulse of the laser. This information is used to normalize the signal. Good agreement has been obtained between the two line Rayleigh scattering and thermocouple results in the particle free co-flowing air jet.

Otugen, M. V.↗

Photometric study of the X-ray pulsar 4U 1626-67

Results are reported for UBVR photometric observations of the optical candidate for the pulsating X-ray source 4U 1626-67. The data are found to be consistent with a constant V magnitude of approximately 19.00 and marginally consistent with constant B-V and U-B colors, but two averaged measures obtained about 2 hr apart suggest that the B-V and U-B colors are variable and that this variability may be entirely in U and B. Additional evidence for variability of the optical candidate is examined, and it is shown that the optical object is probably variable with a B amplitude of no more than about 0.5 mag and time scales as short as less than the order of 1 min. A power spectrum analysis reveals no significant peaks at or near the X-ray pulse period of 7.68 sec or its harmonics. It is concluded that although the optical data do not provide any additional evidence that 4U 1626-67 is a binary, a short-period binary system with the optical emission strongly dominated by an accretion disk is probably favored.

Grindlay, J. E.↗

Doppler Global Velocimetry at NASA Glenn Research Center: System Discussion and Results

A ruggedized Doppler Global Velocimetry system has been built and tested at NASA Glenn Research Center. One component of planar velocity measurements of subsonic and supersonic flows from an under-expanded free jet are reported, which agree well with predicted values. An error analysis evaluates geometric and spectral error terms, and characterizes speckle noise in isotropic data. A multimode, fused fiber optic bundle is demonstrated to couple up to 650 mJ/pulse of laser light without burning or fiber ablation, and without evidence of Stimulated Brillouin Scattering or other spectral-broadening problems. Comparisons are made between spinning wheel data using illumination by freespace beam propagation and fiber optic beam delivery. The fiber bundle illumination is found to provide more spatially even and stable illumination than is typically available from pulsed Nd:YAG laser beams. The fiber bundle beam delivery is also a step toward making remote measurements and automatic real-time plume sectioning feasible in wind tunnel environments.

Lant, Christian T.↗

The Unit of Lightning

For the past century, scientists have made quantitative measurements of lightning discharges. In the process, they refined the definition of a lightning unit, or basic quantum of lightning, in order to base it on observable parameters. Although many components of a lightning discharge have been identified, lightning usually occur in groups of discharges or pulses that, although complex, can be organized into units of flashes. This unit definition is based mainly on measurements of lightning from electric field, video, and ground flash lightning locating networks. More recent instrumentation with various combinations of high sensitivity, high temporal, or high spatial resolution often measure signals produced by lightning that do not cleanly divide into flashes. The data from these systems indicate the need or a more fundamental unit for lightning. Such a unit would be of benefit for both basic understanding of lightning and comparing lightning information between instruments. Without a common lightning unit definition, intercomparisons are difficult. For an example, the Lightning Detection And Ranging system (LDAR) at Kennedy Space Center (KSC) have detected ,flash' rates as high as 600 per minute while analysis based on the Advanced Ground Based Field Mill network (AGBFM) detect only 33 "flashes" per minute in the same area and time periods. The satellite based Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) sometimes see single "flashes" that last longer than 10 seconds. Such long duration flashes are not found in electric field records or ground strike location system data sets. The unit of lightning should be based on the fundamental components of the lightning discharge. This should make the unit as generally applicable as possible. For example, studies of NO(x) production by lightning depend on parameters of the individual lightning channels and not the summary flash characteristics. For such studies, the best unit of lightning may be closer to the classical stroke in the electric field data sets, flash in the LDAR data sets, and group in the OTD/LIS data sets. For this type of study, however, more than just the stroke count information is needed. In this paper, we will outline the current definitions of the unit of lightning and propose new basic definitions for the unit of lightning. Since different instruments detect lightning in different ways and different studies may need almost mutually exclusive aspects of the lightning discharge, there may not be a single definition of the unit of lightning that can be applied to all systems and all studies. However, common components can be found since all instrumentation are detecting aspects of the same phenomenon.

Mach, Douglas M.↗

Raman Lidar Measurements during the International HZO Project: Instrumentation and Analysis Techniques, Popular Summary - 1

The amount of water vapor in the atmosphere helps to determine the likelihood that severe storms may develop. The concentration of water vapor, though, is highly variable in space and time. And yet small changes in water vapor concentration over a short period of time or over a short spatial distance can determine whether a storm may or may not develop. Therefore, in order to improve the ability to forecast severe weather such as thunderstorms it is important to measure water vapor in the atmosphere with high spatial and temporal resolution. One of the most attractive research tools for measuring water vapor in the atmosphere with high spatial and temporal resolution is a Raman lidar. A Raman lidar consists of a laser transmitter, a telescope receiver and optics and electronics for processing opticand electronic signals. A laser pulse is emitted into the atmosphere and it interacts with molecules in the atmosphere causing them to become excited and to emit, through the Raman process, photons of different wavelength than emitted by the laser. The molecule that emitted these emitted. This is the way that a Raman lidar identifies water vapor molecules in the atmosphere. can be identified based on the wavelength of the photons One of the great challenges in Raman lidar measurements has been to make useful daytime measurements of the water vapor profile under bright daytime conditions. In this first of two papers, we describe the instrumentation and analysis of the first documented Raman lidar that is able to measure water vapor in the daytime with sufficient quality to permit the study of developing storm systems.

Whiteman, D. N.↗

Effect of an Additional, Parallel Capacitor on Pulsed Inductive Plasma Accelerator Performance

A model of pulsed inductive plasma thrusters consisting of a set of coupled circuit equations and a one-dimensional momentum equation has been used to study the effects of adding a second, parallel capacitor into the system. The equations were nondimensionalized, permitting the recovery of several already-known scaling parameters and leading to the identification of a parameter that is unique to the particular topology studied. The current rise rate through the inductive acceleration coil was used as a proxy measurement of the effectiveness of inductive propellant ionization since higher rise rates produce stronger, potentially better ionizing electric fields at the coil face. Contour plots representing thruster performance (exhaust velocity and efficiency) and current rise rate in the coil were generated numerically as a function of the scaling parameters. The analysis reveals that when the value of the second capacitor is much less than the first capacitor, the performance of the two-capacitor system approaches that of the single-capacitor system. In addition, as the second capacitor is decreased in value the current rise rate can grow to be twice as great as the rise rate attained in the single capacitor case.

Polzin, Kurt A.↗

Analysis of Doppler lidar data

Dual Doppler lidar analyses of data taken by pulsed lidars demonstrated feasibility of deriving wind fields from coordinated lidar scans. Limited case histories of thunderstorm outflows were obtained. Co-located comparison between Marshall Space Flight Center lidar and NCAR 5.5 cm radar demonstrated desirability of lidar in cases of marginal radar reflectivity in clear air and low-elevation scans. Analysis continued on backscattered intensity and velocity measurements made from April 1983 to February 1984. A slant path method was used to calculate vertical profiles of volumetric backscatter and adsorption in the lower troposphere. High-quality VAD scans were identified as candidates for investigating feasibility of calculating horizontal motion fields using single Doppler lidar. Activities during FY-85 also included participation in Fall 1984 airborne Doppler lidar flight experiments. Preliminary data review was begun using McIdas system. Analysis of backscatter and absorpiton profiles continues. Focus is on understanding spatial and temporal variations, as well as frequency distribution, of backscatter at several tropospheric levels. Results from this study provide input to evaluation of clean/dirty airmass hypothesis of aerosol distribution. Assistance is being given to preparation of a comprehensive, global backscatter measurement plan. Analysis of data from Fall 1984 flight experiments is just beginning. Work has begun on preprocessing data to minimize errors due to electro-optic modulator malfunction during flights.

Rothermel, J.↗

Vibrational Energy Coupling in Expanding N2/O2/NO Admixtures

Recent direct measurements of N2 and O2 vibrational populations in expansions of synthetic air show a closer coupling of the vibrational energies than indicated by adapting earlier experimental results from shock compressions to the nozzle expansion problem. An important difference between the shock wave and nozzle flow problems is the presence of NO in significant amounts throughout the relaxation in the case of a nozzle flow. This may account for the stronger coupling since NO is well suited to promote vibrational energy exchange. The results of a series of experiments and analysis examining vibrational energy coupling in expansions of admixtures approximating air are reported. N2 and O2 vibrational populations are determined by a single-pulse spontaneous Raman scattering technique. NO vibrational populations are determined by broadband absorption by the NO(y) system. The resulting data permit the role of NO in promoting vibrational energy coupling to be better understood, and are used to evaluate models of vibrational energy exchange for application to expanding flows.

Gilmore, John O.↗

Green Propellant Infusion Mission (GPIM) Thruster Valve Testing

The Green Propellant Infusion Mission (GPIM) is a project in the NASA Technology Demonstration Missions (TDM) that will perform a spaceflight demonstration of an AF-M315E propulsion system. The mission is led by Ball Aerospace & Technologies Corporation, with participation across industry and government. The spacecraft is based on the Ball BCP-100 bus, with an Aerojet propulsion system. NASA GSFC provides system testing and analysis of the flow within the AF-M315E propulsion system. A facility was developed at the NASA GSFC propulsion test site to safely use and test the AF-M315E propellant. Testing was performed on multiple 1 N and 22 N non-flight thruster valves provided by Aerojet. A mock-up of the flight system was driven at multiple pressures and temperatures to approximate different flight conditions. Testing was conducted to observe how AF-M315E behaves in fight-like conditions due to the propellant's mass properties heavy dependence on changes in temperature. The testing consisted of driving the different thruster valves at a set on-time and off-time for all and varying the driving pressure from 125 psig to 410 psig. Individual pulses were measured and analyzed for each valve to compare the various rise times and fall times of each thruster valve. The rise times and fall times were then analyzed for thruster valves by measuring the differential pressure from directly upstream and downstream of the valve. The rise times and fall times were also analyzed by measuring the amperage trace of the thruster valve measured with an oscilloscope. The pressure and amperage rise and fall times were compared collectively and individually for the various thruster valves. These results were compared to the fall time data provided by Aerojet.

Hynous, Andrew T.↗