Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Real-time jitter correction in a photonic analog-to-digital converter

A real-time jitter meter is used to measure and digitally sample the pulse-to-pulse timing error in a laser pulse train. The jitter meter is self-referenced using a single-pulse delay line interferometer and measures timing jitter using optical heterodyne detection between two frequency channels of the pulse train. Jitter sensitivity down to 3×10 -10 fs 2 /Hz at 500 MHz has been demonstrated with a pulse-to-pulse noise floor of 1.6 fs. Furthermore, as a proof of principle, the digital correction of the output of a high-frequency photonic analog-to-digital converter (PADC) is demonstrated with an emulated jitter signal. Up to 23 dB of jitter correction, down to the noise floor of the PADC, is accomplished with radio-frequency modulation up to 40 GHz.

47 OTHER INSTRUMENTATION↗

Estimating Soil Thermal Inertia Profiles From the Passive Equilibration of a Temperature Probe

Knowledge of the distribution of soil thermal properties is important for understanding subsurface hydrological and biogeochemical processes. This study describes and evaluates quick thermal profiling (QTP), a new measurement technique aimed at providing rapid, depth-resolved measurements of soil thermal inertia at numerous locations across the landscape. A cylindrical probe with temperature sensors at multiple depths is quickly inserted into the ground, and soil thermal inertia is estimated from how quickly the probe temperature equilibrates with the soil. To this end, a finite volume heat transfer model is used to generate temperature equilibration time series across combinations of controlling factors, and a gridded search inversion approach is applied to infer soil thermal inertia. Field tests in the Arctic indicate that QTP measurements have a minimum uncertainty of 0.14 J m −2 K −1 s −1/2 and covary with dual-probe heat pulse thermal analyzer measurements (concordance correlation coefficient = 0.56) with a root-mean-square error of 0.40 J m −2 K −1 s −1/2 . Besides demonstrating the value of QTP for estimating thermal inertia, this study identifies various sources of measurement uncertainty, particularly probe-soil contact resistance and frictional heating. Further, analysis of soil samples indicates that thermal inertia can be used to estimate thermal conductivity and dry bulk density in the studied area, although such inferences are highly site-specific. Overall, the QTP method holds promise to generate thermal inertia data products and to complement other characterization approaches for advancing understanding of soil properties across far more locations than is currently possible.

Lamb, J. R. [Lawrence Berkeley National Laboratory↗

Electric Field Measurements to Investigate Sheath Formation in a Nanosecond Pulsed Discharge

The objective of the research was to study the temporally and spatially resolved dynamics of sheath formation in a nanosecond pulsed plasma generated in a parallel plate electrode geometry at near atmospheric pressures. We have performed LIF dip measurements at the Sandia Low-Temperature Plasma Research Facility showing the capability to measure electric fields in near atmospheric pressure plasmas although with insufficient spatial resolution near the electrodes. Stark polarization spectroscopy implemented at the University of Minnesota was shown to be able to probe the formation of the sheaths in nanosecond pulsed plasmas. Within 30 ns, a reduction of the sheath thickness to about 250 μm is observed, coinciding with a gradual increase of the discharge current and proportional increase in electric field at the cathode. The electric field evolution as obtained by the fluid model is in excellent agreement with the measurements and shows that an enhanced ionization near the cathode is causing the space charge formation responsible for the increase in electric field. High resolution Stark polarization spectroscopy showed sheaths with dimensions of the order of 50 μm underlining the need of micrometer spatial resolution for sheath characterization in near atmospheric pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling Nonperturbative Field-Driven Vibronic Dynamics: Selective State Preparation and Nonlinear Spectroscopy

The partially linearized density matrix formalism for nonadiabatic dynamics is adapted to incorporate a classical external electromagentic field into the system Hamiltonian. This advancement encompasses the possibility of describing field-driven dynamics and computing a variety of linear and nonlinear spectroscopic signals beyond the perturbative limit. Here, the capabilities of the developed approach are demonstrated on a simple two-state vibronic model coupled to a bath, for which we (a) perform an exhaustive search in the field parameter space for optimal state preparation and (b) compute time-resolved transient absorption spectroscopy to monitor the effect of different pulse shapes on measurable experimental signals. While no restrictions on the form of the field have to be assumed, we focus here on Gaussian shaped (linearly) chirped pulses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A sensitive high repetition rate arrival time monitor for X-ray free electron lasers

X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

47 OTHER INSTRUMENTATION↗

Megahertz Rate Optical Diagnostics of Explosively Generated Soot

Detonation of a solid explosive produces a turbulent and luminous post‐detonation fireball containing condensed carbon soot. Diagnostics of soot dynamics are needed for model validation and to interpret emission signals. Diffuse back‐illumination extinction imaging (DBI‐EI) and laser‐induced incandescence (LII) are two common optical diagnostics for flame soot. This work extends both to measure time‐resolved soot dynamics from a 12 mm HMX hemisphere. DBI‐EI measured line‐of‐sight optical extinction exceeds 99% in some regions. Results are tomographically inverted to obtain a signal proportional to the soot volume fraction. Pulse‐burst LII measures are presented at 1 MHz. For the first time, LII results are combined with DBI‐EI extinction measurements to quantify and correct for signal trapping. Following this, spatially and temporally resolved DBI‐EI and LII measures are shown to be in reasonable agreement. Finally, experimental results are compared against recently developed simulations. Quantitative differences in the soot mixing dynamics are resolved. These findings motivate future model improvements and demonstrate ongoing needs for diagnostic advancements for heavily sooting environments.

diffuse back-illumination extinction imaging↗

Hot-pressed ceramic Fe:ZnSe gain-switched laser

We report the first room temperature gain-switched Fe:ZnSe hot-pressed ceramic laser pumped by 2.94 µm radiation of mechanically Q-switched Er:YAG laser. The maximum output energy at 4.2 µm was 41 mJ at 3 Hz repetition rate and 120 ns pulse duration. The measured slope efficiency was 25% with respect to the absorbed energy. This technique could be attractive for the future development of high-energy short-pulse solid-state mid-IR systems.

36 MATERIALS SCIENCE↗

Rapid and precise tracking of water influx and efflux across cell membranes induced by a pulsed electric field

Quantitative measurements of water content within a single cell are notoriously difficult. In this work, we introduce a single-shot optical method for tracking the intracellular water content, by mass and volume, of a single cell at video rate. We utilize quantitative phase imaging and a priori knowledge of a spherical cellular geometry, leveraging a two-component mixture model to compute the intracellular water content. We apply this technique to study CHO-K1 cells responding to a pulsed electric field, which induces membrane permeabilization and rapid water influx or efflux depending upon the osmotic environment. The effects of mercury and gadolinium on water uptake in Jurkat cells following electropermeabilization are also examined.

59 BASIC BIOLOGICAL SCIENCES↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Femtosecond electronic structure response to high intensity XFEL pulses probed by iron X-ray emission spectroscopy

We report the time-resolved femtosecond evolution of the K-shell X-ray emission spectra of iron during high intensity illumination of X-rays in a micron-sized focused hard X-ray free electron laser (XFEL) beam. Detailed pulse length dependent measurements revealed that rapid spectral energy shift and broadening started within the first 10 fs of the X-ray illumination at intensity levels between 10 17 and 10 18 W cm -2 . We attribute these spectral changes to the rapid evolution of high-density photoelectron mediated secondary collisional ionization processes upon the absorption of the incident XFEL radiation. These fast electronic processes, occurring at timescales well within the typical XFEL pulse durations (i.e., tens of fs), set the boundary conditions of the pulse intensity and sample parameters where the widely-accepted ‘probe-before-destroy’ measurement strategy can be adopted for electronic-structure related XFEL experiments.

99 GENERAL AND MISCELLANEOUS↗

When Do Band Gap Calculations Agree with Experiments in Monolayer-Protected Cu 14 and Au 20 Atomically Precise Nanoclusters? A (TD)-DFT Comparison of HOMO–LUMO, Fundamental, Optical, and Electrochemical Energy Gaps

In view of the tremendous progress in atomically precise metal nanoclusters where electrochemical and optical energetics are routinely supported by computations to establish structure−function correlations, we explore the relationship between different protocols for measuring and computing band gaps of two distinct organic ligand-protected nanoclusters: [Cu 14 H 10 (MBN) 3 (PPh 3 ) 8 ] + and Au 20 (TBBT) 16 . Through UV/visible spectroscopy and differential pulse voltammetry, we measure optical and electrochemical band gaps in those systems. We then compare these experimentally determined gaps to HOMO−LUMO gaps, fundamental gaps, vertical excitation energies, and E o ox − E o red potentials computed using different density functional theory (DFT) or time-dependent DFT (TDDFT) methods. Specifically, in both copper and gold nanoclusters, we test the effect of truncating inert ligands from the model and compare density functionals with varying degrees of Hartree−Fock (HF) exchange from 0 to 50%, range-separated hybrids with a varying long-range tuning parameter, different correlation functionals, basis sets, and (equilibrium and nonequilibrium) continuum solvation models. Despite having different frontier orbital characters (the copper nanocluster has a metal-to-ligand charge transfer character while the gold nanocluster has metal-centered frontier orbitals), both nanoclusters display a similar sensitivity of the HOMO−LUMO gap to the HF exchange that is partially mitigated when computing the fundamental, optical, and electrochemical gaps. Other factors, such as the nature of the correlation functional, basis set, and geometry relaxation, have a considerably smaller effect on computed band gaps in these systems. Overall, this work provides guidelines for factors of varied importance for correlating computed and experimental band gap values.

Chemical calculations↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Tangential extreme ultraviolet and soft x-ray diagnostic system for time-resolved temperature measurement on the High Beta Tokamak-Extended Pulse

The High Beta Tokamak-Extended Pulse has recently incorporated a tangential multi-energy extreme ultraviolet and soft x-ray diagnostic system. This system enables measurements of the electron temperature and the examination of mode dynamics within the tokamak. While other systems have been built for poloidal views over similar temperature ranges, this is the first multi-energy tangential-view system designed to work in a temperature range below 200 eV in a tokamak. To facilitate these measurements, a filter wheel comprising five distinct groups of dual-filters has been developed and implemented. By employing a combination of 0.1 μm aluminum and 0.2 μm titanium filters, the system allows estimation of electron temperature profiles through reconstruction of the emission profile using the standard “double-foil” technique. The influence of impurities and filter oxide layers on measurement outcomes is examined. Results reveal that, while the absolute electron temperature values may exhibit some deviations, key characteristics like the electron temperature profile shape and inversion radius during sawtooth events remain consistent. This consistency confirms the system’s suitability for core plasma studies. This system has proven effective in detecting and analyzing internal magnetohydrodynamic phenomena, such as sawteeth.

Instruments & Instrumentation↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

A Platform-Independent X-ray Diffraction Diagnostic for Phase Transition Kinetics in Traditional and Synthetic Microstructure Materials (LDRD Project 213088 Final Report)

Pulsed-power generators using the magnetic loading technique are able to produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength-strain rate dependence, structural phase transitions, and density of crystal defects such as dislocations. Here, we present a cost effective, compact X-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically-driven ramp compression of materials with single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials community. The success in fielding this new XRD diagnostic dramatically improves our predictive capability and understanding of rate-dependent behavior at or near phase transition. As Sandia plans the next-generation pulse-power driver platform, a key element needed to deliver new state-of-the-art experiments will be having the necessary diagnostic tools to probe new regimes and phenomena. These diagnostics need to be as versatile, compact, and portable as they are powerful. The development of a platform-independent XRD diagnostic gives Sandia researchers a new window to study the microstructure and phase dynamics of materials under load. This project has paved the way for phase transition research in a variety of materials with mission interest.

36 MATERIALS SCIENCE↗

Study of the Design and Characteristics of a Modified Pulsed Plasma Thruster with Graphite and Tungsten Trigger Electrodes

The paper presents experimental results for a modified pulsed plasma thruster (PPT) with solid propellant, using a coaxial anode–cathode design. Graphite from pencil leads served as propellant, and a tungsten trigger electrode was tested to reduce carbonization effects. Experiments were performed in a vacuum chamber at 0.001 Pa, employing diagnostics such as discharge current/voltage recording, power measurement, ballistic pendulum, time-of-flight (TOF) method, and a Faraday cup. Current and voltage waveforms matched an oscillatory RLC circuit with variable plasma channel resistance. Key discharge parameters were measured, including current pulse duration/amplitude and plasma channel formation/decay dynamics. Impulse bit values, obtained with a ballistic pendulum, reached up to 8.5 μN·s. Increasing trigger capacitor capacitance reduced thrust due to unstable “pre-plasma” formation and partial pre-discharge energy loss. Using TOF and Faraday cup diagnostics, plasma front velocity, ion current amplitude, current density, and ion concentration were determined. Tungsten electrodes produced lower charged particle concentrations than graphite but offered better adhesion resistance, minimal carbonization, and stable long-term performance. The findings support optimizing trigger electrode materials and PPT operating modes to extend lifetime and stabilize thrust output.

Faraday cup↗