Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

WE-AB-202-09: Feasibility and Quantitative Analysis of 4DCT-Based High Precision Lung Elastography

Purpose: The purpose of this project is to derive high precision elastography measurements from 4DCT lung scans to facilitate the implementation of elastography in a radiotherapy context. Methods: 4DCT scans of the lungs were acquired, and breathing stages were subsequently registered to each other using an optical flow DIR algorithm. The displacement of each voxel gleaned from the registration was taken to be the ground-truth deformation. These vectors, along with the 4DCT source datasets, were used to generate a GPU-based biomechanical simulation that acted as a forward model to solve the inverse elasticity problem. The lung surface displacements were applied as boundary constraints for the model-guided lung tissue elastography, while the inner voxels were allowed to deform according to the linear elastic forces within the model. A biomechanically-based anisotropic convergence magnification technique was applied to the inner voxels in order to amplify the subtleties of the interior deformation. Solving the inverse elasticity problem was accomplished by modifying the tissue elasticity and iteratively deforming the biomechanical model. Convergence occurred when each voxel was within 0.5 mm of the ground-truth deformation and 1 kPa of the ground-truth elasticity distribution. To analyze the feasibility of the model-guided approach, we present the results for regions of low ventilation, specifically, the apex. Results: The maximum apical boundary expansion was observed to be between 2 and 6 mm. Simulating this expansion within an apical lung model, it was observed that 100% of voxels converged within 0.5 mm of ground-truth deformation, while 91.8% converged within 1 kPa of the ground-truth elasticity distribution. A mean elasticity error of 0.6 kPa illustrates the high precision of our technique. Conclusion: By utilizing 4DCT lung data coupled with a biomechanical model, high precision lung elastography can be accurately performed, even in low ventilation regions of the lungs. This material is based upon work supported by the National Science Foundation Graduate Research Fellowship under Grant No. DGE-1144087.

60 APPLIED LIFE SCIENCES↗

Quantitative analysis of optical and recombination losses in Cu(In,Ga)Se{sub 2} thin-film solar cells

Optical and recombination losses in a Cu(In,Ga)Se{sub 2} thin-film solar cell with a band gap of 1.36–1.38 eV are theoretically analyzed. The optical transmittance of the ZnO and CdS layers through which the radiation penetrates into the absorbing layer is determined. Using optical constants, the optical loss caused by reflection at the interfaces (7.5%) and absorption in the ZnO and CdS layers (10.2%) are found. To calculate the recombination loss, the spectral distribution of the quantum efficiency of CdS/CuIn{sub 1–x}Ga{sub x}Se{sub 2} is investigated. It is demonstrated that, taking the drift and diffusion components of recombination at the front and rear surfaces of the absorber into account, the quantum efficiency spectra of the investigated solar cell can be analytically described in detail. The real parameters of the solar cell are determined by comparing the calculated results and experimental data. In addition, the losses caused by the recombination of photogenerated carriers at the front and rear surfaces of the absorbing layer (1.8% and <0.1%, respectively), at its neutral part (7.6%), and in the space-charge region of the p–n heterojunction (1.0%) are determined. A correction to the parameters of Cu(In,Ga)Se{sub 2} is proposed, which enhances the charge-accumulation efficiency.

36 MATERIALS SCIENCE↗

Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents

General conditions and requirements for an internal standard useful in the determination of chemical warfare agents (CWAs) by the method of gas chromatography coupled with mass detection (GC/MS) were defined. The determination is based on a GC/MS analysis of a mixture of a CWA with an internal standard, conversion of the TIC chromatogram to a chromatogram extracted at a particular m / z ratio, and calculation of the CWA concentration from the internal standard concentration, response factor, and chromatographic peak areas. Available internal standards were identified, and they were verified for seven organophosphorus nerve-paralysing agents. Corresponding response factors were determined as a ratio of gradients of the linear functions of the peak area and compound concentration. Linearity, repeatability, and accuracy of the measurements were evaluated. The determination can be performed on all GC/MS systems of the Fire Rescue Service of the Czech Republic (FRS), where no CWA standards are available.

Capoun, Tomas↗

A Piecewise Local Partial Least Squares (PLS) Method for the Quantitative Analysis of Plutonium Nitrate Solutions

We have developed a piecewise local (PL) partial least squares (PLS) analysis method for total plutonium measurements by absorption spectroscopy in nitric acid-based nuclear material processing streams. Instead of using a single PLS model that covers all expected solution conditions, the method selects one of several local models based on an assessment of solution absorbance, acidity, and Pu oxidation state distribution. The local models match the global model for accuracy against the calibration set, but were observed in several instances to be more robust to variations associated with measurements in the process. The improvements are attributed to the relative parsimony of the local models. Not all of the sources of spectral variation are uniformly present at each part of the calibration range. Thus, the global model is locally overfitting and susceptible to increased variance when presented with new samples. A second set of models quantifies the relative concentrations of Pu(III), (IV), and (VI). Standards containing a mixture of these species were not at equilibrium due to a disproportionation reaction. Therefore, a separate principal component analysis is used to estimate of the concentrations of the individual oxidation states in these standards in the absence of independent confirmatory analysis. The PL analysis approach is generalizable to other systems where the analysis of chemically complicated systems can be aided by rational division of the overall range of solution conditions into simpler sub-regions.

47 OTHER INSTRUMENTATION↗

Quantitative analysis of multilayer organization of proteins and RNA in nuclear speckles at super resolution

Nuclear speckles are self-assembled organelles composed of RNAs and proteins. They are proposed to act as structural domains that control distinct steps in gene expression, including transcription, splicing and mRNA export. Earlier studies identified differential localization of a few components within the speckles. It was speculated that the spatial organization of speckle components might contribute directly to the order of operations that coordinate distinct processes. Here, by performing multi-color structured illumination microscopy, we characterized the multilayer organization of speckles at a higher resolution. We found that SON and SC35 (also known as SRSF2) localize to the central region of the speckle, whereas MALAT1 and small nuclear (sn)RNAs are enriched at the speckle periphery. Coarse-grained simulations indicate that the non-random organization arises due to the interplay between favorable sequence-encoded intermolecular interactions of speckle-resident proteins and RNAs. Finally, we observe positive correlation between the total amount of RNA present within a speckle and the speckle size. These results imply that speckle size may be regulated to accommodate RNA accumulation and processing. Accumulation of RNA from various actively transcribed speckle-associated genes could contribute to the observed speckle size variations within a single cell.

Fei, Jingyi↗

Dataset for Top Model Decision Tree: Selecting Segmentation Models for Reliable Quantitative Analysis in Low- and Ultralow-Dose CryoEM

Motivation Multiple deep learning model architectures can be used to segment bacterial membranes in cryoEM images. However, an AI-based tool advancement is often presented with only a single segmentation model for broad use, and this single model may show inconsistent results across datasets from different users. Here, we present the Top Model Decision Tree, a model screening framework to screen for the best model to generate bacterial inner and outer membrane masks based on user priorities. We use pre-trained segmentation models from YOLOv11, YOLO26, U-Net, Detectron2 and SAM3 fine-tuned on bacterial inner and outer membranes imaged with cryoEM. Run the Framework This notebook must be opened in Google Colab. Mount Google Drive and run with a GPU-based runtime. Open the notebook and follow steps to git clone in folders and files within this repository. There will be a repeating top_model_decision_tree.ipynb (notebook clone) that will not be used. Save your .png binary mask files and .csv table outputs within your Google Drive or download before closing the notebook. The models and all analysis/training scripts are available at [GitHub: https://github.com/Lynnicia/CryoEM_membranes_top_model_decision_tree and https://github.com/Sireesiru/Semantic-Segmentation-of-bacterial-cell-envelope-using-U-Nets.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative analysis of toxic metals lead and cadmium in water jet by laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) has been applied to the analysis of toxic metals Pb and Cd in Pb(NO{sub 3}){sub 2} and Cd(NO{sub 3}){sub 2}.4H{sub 2}O aqueous solutions, respectively. The plasma is generated by focusing a nanosecond Nd:YAG ({lambda}=1064 nm) laser on the surface of liquid in the homemade liquid jet configuration. With an assumption of local thermodynamic equilibrium (LTE), calibration curves of Pb and Cd were obtained at different delay times between 1 to 5 {mu}s. The temporal behavior of limit of detections (LOD) was investigated and it is shown that the minimum LODs for Pb and Cd are 4 and 68 parts in 10{sup 6} (ppm), respectively. In order to demonstrate the correctness of the LTE assumption, plasma parameters including plasma temperature and electron density are evaluated, and it is shown that the LTE condition is satisfied at all delay times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Education and Outreach in the Life Sciences: Quantitative Analysis Report

The DOE's National Nuclear Security Agency (NNSA) asked Pacific Northwest National Laboratory (PNNL) to consider the role of individual scientists in upholding safety and security. The views of scientists were identified as being a critical component of this policy process. Therefore, scientists, managers, and representatives of Institutional Biosafety Committees (IBCs) at the national labs were invited to participate in a brief survey. This report presents the results from the web survey.

60 APPLIED LIFE SCIENCES↗

Strategic Sequencing for State Distributed PV Policies: A Quantitative Analysis of Policy Impacts and Interactions

State and local policymakers show increasing interest in spurring the development of customer-sited distributed generation (DG), in particular solar photovoltaic (PV) markets. Prompted by that interest, this analysis examines the use of state policy as a tool to support the development of a robust private investment market. This analysis builds on previous studies that focus on government subsidies to reduce installation costs of individual projects and provides an evaluation of the impacts of policies on stimulating private market development.

14 SOLAR ENERGY↗

Quantitative analysis of concrete using portable x-ray fluorescence: Method development and validation

During Decommissioning and Demolition (D&D) activities at SRS, it is important that the building be screened for radionuclides and heavy metals to ensure that the proper safety and disposal metrics are in place. A major source of contamination at DOE facilities is the accumulation of mercury contamination, from nuclear material processing and Liquid Waste System (LWS). This buildup of mercury could possibly cause harm to any demolition crew or the environment should this material be released. The current standard method is to take core samples in various places in the facility and use X-ray fluorescence (XRF) to detect the contamination. This standard method comes with a high financial value due to the security levels of these sample facilities with unknown contamination levels. Here in we propose the use of portable XRF units to detect for this contamination on-site. To validate this method, the instrument has to be calibrated to detect the heavy metal contamination, be both precise with the known elemental concentrations and consistent with its actual results of a sample concrete and pristine contaminant, and be able to detect changes in the sample concrete’s composition. After receiving the various concrete samples with their compositions found by a XRF wave-dispersive method, the calibration factor’s linear regressions were adjusted to give the baseline concentration of the concrete with no contamination. Samples of both concrete and concrete/flyash were evaluated; their standard deviations revealed that the measurements were consistent with the known composition. Finally, the samples were contaminated with different concentrations of sodium tungsten dihydrate, allowed to air dry, and measured. When the contaminated samples were analyzed, the heavy metal contamination was seen within the spectrum of the instrument, but there was not a trend of quantification based on the concentration of the solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Energy Efficiency of Plants: Quantitative Analysis of Carbon Flux

The efficiency in harvesting light energy is essential for both crop and feedstock productivity. Key targets for optimization of energy efficiency include energy capture, conversion, translocation and storage. Surprisingly little is known about the mechanisms of carbon allocation and the communication between source and sink. We surmise that regulatory networks that coordinate carbon partitioning and allocation might be control points and thus suitable for optimization by engineering. At a first step towards identifying such regulatory networks, our lab identified key players in missing steps of allocation, specifically cellular sugar uptake (SUT family, founding members identified by my team) and cellular efflux carriers (SWEET superfamily, founding members identified by my team). In plants, both classes of transporters are encoded by multigene families. We show that specific subsets of SWEETs serve critical roles in cellular sucrose efflux in the leaf for phloem loading, in seeds for seed filling, as well as in nectar section and vacuolar storage; similarly SUTs play critical roles in cellular uptake during phloem loading and seed filling. Access to the plant SWEETs provided the clues needed for identifying novel bacterial and human sugar transporters. Moreover, we found that pathogens hijack SWEETs to access the plants energy resources. In contrast to SUTs, which are predominantly proton symporters, SWEETs appear to function as facilitators, and thus must be tightly regulated to prevent spillover of carbon into cell walls. One of the key goals of this project was to identify such carriers, characterize the role of key members in carbon allocation. To decrypt the biological circuits we need novel diagnostic tools that, analogous to oscilloscopes in electrical engineering of circuit boards, allow us to quantify fluxes; here by monitoring sugars. Such probes can provide crucial information on systems properties such as metabolic impedance. To measure steady state metabolite levels with minimal invasive methods, and to develop impedance measurements in vivo, we constructed and optimized a set of probes, namely Förster Resonance Energy Transfer (FRET) nanosensors for glucose and sucrose. The probes monitor the concentration of a specific metabolite with high temporal resolution, and, since encoded genetically, can be targeted to specific cells or even specific cellular compartments and thus obtain measurements with cellular and subcellular resolution. We also developed a new platform for monitoring such sensors in vivo, the RootChip.

09 BIOMASS FUELS↗

Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling

We investigate the existence of the principal-agent (PA) problem in non-government, non-mall commercial buildings in the U.S. in 2003. The analysis concentrates on space heating and cooling energy consumed by centrally installed equipment in order to verify whether a market failure caused by the PA problem might have prevented the installation of energy-efficient devices in non-owner-occupied buildings (efficiency problem) and/or the efficient operation of space-conditioning equipment in these buildings (usage problem). Commercial Buildings Energy Consumption Survey (CBECS) 2003 data for single-owner, single-tenant and multi-tenant occupied buildings were used for conducting this evaluation. These are the building subsets with the appropriate conditions for assessing both the efficiency and the usage problems. Together, these three building types represent 51.9percent of the total floor space of all buildings with space heating and 59.4percent of the total end-use energy consumption of such buildings; similarly, for space cooling, they represent 52.7percent of floor space and 51.6percent of energy consumption. Our statistical analysis shows that there is a usage PA problem. In space heating it applies only to buildings with a small floor area (<_50,000 sq. ft.). We estimate that in 2003 it accounts for additional site energy consumption of 12.3 (+ 10.5 ) TBtu (primary energy consumption of 14.6 [+- 12.4] TBtu), corresponding to 24.0percent (+- 20.5percent) of space heating and 10.2percent (+- 8.7percent) of total site energy consumed in those buildings. In space cooling, however, the analysis shows that the PA market failure affects the complete set of studied buildings. We estimate that it accounts for a higher site energy consumption of 8.3 (+-4.0) TBtu (primary energy consumption of 25.5 [+- 12.2]TBtu), which corresponds to 26.5percent (+- 12.7percent) of space cooling and 2.7percent (+- 1.3percent) of total site energy consumed in those buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗