Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Study of solid state photomultiplier

Available solid state photomultiplier (SSPM) detectors were tested under low-background, low temperature conditions to determine the conditions producing optimal sensitivity in a space-based astronomy system such as a liquid cooled helium telescope in orbit. Detector temperatures varied between 6 and 9 K, with background flux ranging from 10 to the 13th power to less than 10 to the 6th power photons/square cm-s. Measured parameters included quantum efficiency, noise, dark current, and spectral response. Experimental data were reduced, analyzed, and combined with existing data to build the SSPM data base included herein. The results were compared to analytical models of SSPM performance where appropriate models existed. Analytical models presented here were developed to be as consistent with the data base as practicable. Significant differences between the theory and data are described. Some models were developed or updated as a result of this study.

Hays, K. M.↗

InGaAsSb/GaSb thermophotovoltaic cells

AstroPower is developing InGaAsSb thermophotovoltaic (TPV) devices. This photovoltaic cell is a two-layer epitaxial InGaAsSb structure formed by liquid-phase epitaxy on a GaSb substrate. The (direct) bandgap of the In(1 - x)Ga(x)As(1 -y)Sb(y) alloy is 0.50 to 0.55 eV, depending on its exact alloy composition (x, y); and is closely lattice-matched to the GaSb substrate The use of the quaternary alloy, as opposed to a ternary alloy - such as, for example, InGaAs/InP - permits low bandgap devices optimized for 1000 to 1500 C thermal sources with, with at the time, near-exact lattice matching to the GaSb substrate. Lattice-matching is important since even a small degree of lattice mismatch degrades device performance and reliability and increases processing complexity. For bandgaps of 0.52 eV,Fo internal quantum efficiencies as high as 95% have been measured at a wavelength of 2 microns. At 1 micron wavelengths, internal quantum efficiencies of 55% have been observed. The open-circuit voltage at currents of 0.3 A/sq cm is 0.220 volts and 0.260 V for current densities of 2 A/sq cm. Fill factors of 56% have also been measured. These preliminary results lead to the conclusion that the GaSb-based quaternary compounds provide a viable and high performance energy conversion solution for thermophotovoltaic systems operating with 1000 to 1500 C source temperatures.

Mauk, M. G.↗

Multi-Color QWIP FPAs for Hyperspectral Thermal Emission Instruments

Infrared focal plane arrays (FPAs) covering broad mid- and long-IR spectral ranges are the central parts of the spectroscopic and imaging instruments in several Earth and planetary science missions. To be implemented in the space instrument these FPAs need to be large-format, uniform, reproducible, low-cost, low 1/f noise, and radiation hard. Quantum Well Infrared Photodetectors (QWIPs), which possess all needed characteristics, have a great potential for implementation in the space instruments. However a standard QWIP has only a relatively narrow spectral coverage. A multi-color QWIP, which is compromised of two or more detector stacks, can to be used to cover the broad spectral range of interest. We will discuss our recent work on development of multi-color QWIP for Hyperspectral Thermal Emission Spectrometer instruments. We developed QWIP compromising of two stacks centered at 9 and 10.5 ?m, and featuring 9 grating regions optimized to maximize the responsivity in the individual subbands across the 7.5-12 ?m spectral range. The demonstrated 1024x1024 QWIP FPA exhibited excellent performance with operability exceeding 99% and noise equivalent differential temperature of less than 15 mK across the entire 7.5-12 ?m spectral range.

Infrared focal plane arrays (FPAs)↗

Quantum chemical studies of a model for peptide bond formation. 3. Role of magnesium cation in formation of amide and water from ammonia and glycine

The SN2 reaction between glycine and ammonia molecules with magnesium cation Mg2+ as a catalyst has been studied as a model reaction for Mg(2+)-catalyzed peptide bond formation using the ab initio Hartree-Fock molecular orbital method. As in previous studies of the uncatalyzed and amine-catalyzed reactions between glycine and ammonia, two reaction mechanisms have been examined, i.e., a two-step and a concerted reaction. The stationary points of each reaction including intermediate and transition states have been identified and free energies calculated for all geometry-optimized reaction species to determine the thermodynamics and kinetics of each reaction. Substantial decreases in free energies of activation were found for both reaction mechanisms in the Mg(2+)-catalyzed amide bond formation compared with those in the uncatalyzed and amine-catalyzed amide bond formation. The catalytic effect of the Mg2+ cation is to stabilize both the transition states and intermediate, and it is attributed to the neutralization of the developing negative charge on the electrophile and formation of a conformationally flexible nonplanar five-membered chelate ring structure.

Magnesium/chemistry↗

NASA Tech Briefs, March 2008

Topics covered include: WRATS Integrated Data Acquisition System; Breadboard Signal Processor for Arraying DSN Antennas; Digital Receiver Phase Meter; Split-Block Waveguide Polarization Twist for 220 to 325 GHz; Nano-Multiplication-Region Avalanche Photodiodes and Arrays; Tailored Asymmetry for Enhanced Coupling to WGM Resonators; Disabling CNT Electronic Devices by Use of Electron Beams; Conical Bearingless Motor/Generators; Integrated Force Method for Indeterminate Structures; Carbon-Nanotube-Based Electrodes for Biomedical Applications; Compact Directional Microwave Antenna for Localized Heating; Using Hyperspectral Imagery to Identify Turfgrass Stresses; Shaping Diffraction-Grating Grooves to Optimize Efficiency; Low-Light-Shift Cesium Fountain without Mechanical Shutters; Magnetic Compensation for Second-Order Doppler Shift in LITS; Nanostructures Exploit Hybrid-Polariton Resonances; Microfluidics, Chromatography, and Atomic-Force Microscopy; Model of Image Artifacts from Dust Particles; Pattern-Recognition System for Approaching a Known Target; Orchestrator Telemetry Processing Pipeline; Scheme for Quantum Computing Immune to Decoherence; Spin-Stabilized Microsatellites with Solar Concentrators; Phase Calibration of Antenna Arrays Aimed at Spacecraft; Ring Bus Architecture for a Solid-State Recorder; and Image Compression Algorithm Altered to Improve Stereo Ranging.

Source record↗

Influence of Growth Parameters and Annealing on Properties of MBE Grown GaAsSbN SQWs

In this paper we report the growth of GaAsSbN/GaAs single quantum well (SQW) heterostructures by molecular beam epitaxy (MBE) and their properties. A systematic study has been carried out to determine the effect of growth conditions, such as the source shutter opening sequence and substrate temperature, on the structural and optical properties of the layers. The substrate temperatures in the range of 450-470 C were found to be optimal. Simultaneous opening of the source shutters (SS) resulted in N incorporation almost independent of substrate temperature and Sb incorporation higher at lower substrate temperatures. The effects of ex-situ annealing in nitrogen ambient and in-situ annealing under As ovepressure on the optical properties of the layers have also been investigated. A significant increase in photoluminescence (PL) intensity with reduced full width at half maxima (FWHM) in conjunction with a blue shift in the emission energy was observed on 10 annealing the samples. In in-situ annealed samples, the PL line shapes were more symmetric and the temperature dependence of the PL peak energy indicated significant decrease in the exciton localization energy as exhibited by a less pronounced S-shaped curve. The inverted S-shaped curve observed in the temperature dependence of PL FWHM is also discussed. 1.61 micrometer emission with FWHM of 25 meV at 20K has been obtained in in-situ annealed GaAsSbN/GaAs SQW grown at 470 C by SS.

Wu, Liangjin↗

Advanced Inductively Coupled Plasma Etching Processes for Fabrication of Resonator-Quantum Well Infrared Photodetector

Resonator-quantum well infrared photodetectors (R-QWIPs) are the next generation of QWIP detectors that use resonances to increase the quantum efficiency (QE). To achieve the expected performance, the detector geometry must be produced in precise specification. In particular, the height of the diffractive elements (DE) and the thickness of the active resonator must be uniformly and accurately realized to within 0.05 lm accuracy and the substrates of the detectors have to be removed totally. To achieve these specifications, two optimized inductively coupled plasma (ICP) etching processes are developed. Using these etching techniques, we have fabricated a number of R-QWIP test detectors and FPAs with the required dimensions and completely removed the substrates of the test detectors and FPAs. Their QE spectra were tested to be in close agreement with the theoretical predictions. The operability and spectral non-uniformity of the FPA is about 99.57% and 3% respectively.

plasma etching process↗

A Gaussian measure of quantum phase noise

We study the width of the semiclassical phase distribution of a quantum state in its dependence on the average number of photons (m) in this state. As a measure of phase noise, we choose the width, delta phi, of the best Gaussian approximation to the dominant peak of this probability curve. For a coherent state, this width decreases with the square root of (m), whereas for a truncated phase state it decreases linearly with increasing (m). For an optimal phase state, delta phi decreases exponentially but so does the area caught underneath the peak: all the probability is stored in the broad wings of the distribution.

Schleich, Wolfgang P.↗

The ILRS: Approaching 20 Years and Planning for the Future

The International Laser Ranging Service (ILRS) was established by the International Association of Geodesy (IAG) in 1998 to support programs in geodesy, geophysics, fundamental constants and lunar research, and to provide the International Earth Rotation Service with data products that are essential to the maintenance and improvement in the International Terrestrial Reference Frame (ITRF), the basis for metric measurements of changes in the Earth and Earth–Moon system. Other scientific products derived from laser ranging include precise geocentric positions and motions of ground stations, satellite orbits, components of Earth’s gravity field and their temporal variations, Earth Orientation Parameters, precise lunar ephemerides and information about the internal structure of the Moon. Laser ranging systems are already measuring the one-way distance to remote optical receivers in space and are performing very accurate time transfer between remote sites in the Earth and in Space. The ILRS works closely with the IAG’s Global Geodetic Observing System. The ILRS develops (1) the standards and specifications necessary for product consistency, and (2) the priorities and tracking strategies required to maximize network efficiency. The service collects, merges, analyzes, archives and distributes satellite and lunar laser ranging data to satisfy a variety of scientific, engineering, and operational needs and encourages the application of new technologies to enhance the quality, quantity, and cost effectiveness of its data products. The ILRS works with (1) new satellite missions in the design and building of retroreflector targets to maximize data quality and quantity, and (2) science programs to optimize scientific data yield. Since its inception, the ILRS has grown to include forty laser ranging stations distributed around the world. The ILRS stations track more than ninety satellites from low Earth orbit (LEO) to the geosynchronous orbit altitude as well as retroreflector arrays on the surface of the Moon. Applications have been expanded to include time transfer, asynchronous ranging for targets at extended ranges, free space quantum telecommunications, and the tracking of space debris. Laser ranging technology is moving to lower energy, higher repetition rates (kHz), single-photon-sensitive detectors, shorter pulse widths, shorter normal point intervals for faster data acquisition, and increased pass interleaving, automated to autonomous operation with remote access, and embedded software for real-time updates and decision making. An example of pass interleaving is presented for the Yarragadee station (see Fig. 4); tracking of LEO satellites is often accommodated during break in LEO and GNSS passes. New satellites arrays provide more compact targets and work continues on the development of lighter less expensive arrays for satellites and the moon. The service now provides operational ITRF products including daily/ weekly station positions and daily resolution Earth orientation products; the flow of weekly combination of satellite orbit files for LAGEOS/Etalon-1 and -2 has recently been established. New products are under testing through a pilot project on systematic error monitoring currently underway. The article will give an overview of activities underway within the service, paths forward presently envisioned, and current issues and challenges.

Laser retroreflectors↗

Comparison of 2- and 10-micron coherent Doppler lidar performance

The performance of 2- and 10-micron coherent Doppler lidar is presented in terms of the statistical distribution of the maximum-likelihood velocity estimator from simulations for fixed range resolution and fixed velocity search space as a function of the number of coherent photoelectrons per estimate. The wavelength dependence of the aerosol backscatter coefficient, the detector quantum efficiency, and the atmospheric extinction produce a simple shift of the performance curves. Results are presented for a typical boundary layer measurement and a space-based measurement for two regimes: the pulse-dominated regime where the signal statistics are determined by the transmitted pulse, and the atmospheric-dominated regime where the signal statistics are determined by the velocity fluctuations over the range gate. The optimal choice of wavelength depends on the problem under consideration.

Frehlich, Rod↗

Transition-Edge Hot-Electron Microbolometers for Millimeter and Submillimeter Astrophysics

The millimeter and the submillimeter wavelengths of the electromagnetic spectrum hold a wealth of information about the evolution of the universe. In particular, cosmic microwave background (CMB) radiation and its polarization carry the oldest information in the universe, and provide the best test of the inflationary paradigm available to astronomy today. Detecting gravity waves through their imprint on the CMB polarization would have extraordinary repercussions for cosmology and physics. A transition-edge hot-electron micro - bolometer (THM) consists of a superconducting bilayer transition-edge sensor (TES) with a thin-film absorber. Unlike traditional monolithic bolometers that make use of micromachined structures, the THM em ploys the decoupling between electrons and phonons at millikelvin temperatures to provide thermal isolation. The devices are fabricated photolithographically and are easily integrated with antennas via microstrip transmission lines, and with SQUID (superconducting quantum interference device) readouts. The small volume of the absorber and TES produces a short thermal time constant that facilitates rapid sky scanning. The THM consists of a thin-film metal absorber overlapping a superconducting TES. The absorber forms the termination of a superconducting microstripline that carries RF power from an antenna. The purpose of forming a separate absorber and TES is to allow flexibility in the optimization of the two components. In particular, the absorbing film's impedance can be chosen to match the antenna, while the TES impedance can be chosen to match to the readout SQUID amplifier. This scheme combines the advantages of the TES with the advantages of planar millimeter-wave transmission line circuits. Antenna-coupling to the detectors via planar transmission lines allows the detector dimensions to be much smaller than a wavelength, so the technique can be extended across the entire microwave, millimeter, and submillimeter wavelength ranges. The circuits are fabricated using standard microlithographic techniques and are compatible with uniform, large array formats. Unlike traditional monolithic bolometers that make use of micromachined structures, the THM employs the decoupling between electrons and phonons at millikelvin temperatures to provide thermal isolation. There is no fragile membrane in the structure for thermal isolation, which improves the fabrication yield.

Hsieh, Wen-Ting↗

Noise in Josepson effect mixers and the RSJ model

Josephson effect mixers have previously been observed to display 'excess' noise both in experiments with point contacts and in numerical simulations using the resistively shunted junction (RSJ) model. This excess noise causes the mixer noise temperature to be a factor of typically 20-100 times the physical temperature of the device. Previously, this excess was ascribed to conversion from unwanted sidebands of the local oscillator and Josephson frequencies and their harmonics. Our numerical modeling of the RSJ equations has led to a new understanding of the excess noise, which is simply due to the intrinsic Josephson oscillations of the device. In addition, we have extended the modeling to include the previously ignored case of finite device capacitance (i.e. RSJ capacitance parameter beta(sub c) does not equal 0, which is more realistic for lithographically defined Josephson such as shunted tunnel junctions or SNS bridges. For some cases, this yields an improvement of a factor of two in noise temperature from the zero capacitance models. We will discuss the device parameters which optimize the mixer performance for frequencies approaching the characteristic frequency of the device, which is given by the Josephson frequency at the I(sub c)R(sub n) voltage (nu = 2eI(sub c)R(sub n)/h). These modeling results predict good conversion efficiency and a noise temperature within a factor of a few of the physical temperature. Experiments are in progress to determine the accuracy of this modeling using a waveguide mixer at 100 GHz with optimized, resistively shunted Nb tunnel junctions. If the modeling results are valid, they are particularly encouraging for mixers in the submillimeter regime, given the possibility of obtaining non-hysteretic Josephson devices with I(sub c)R(sub n) products in excess of a millivolt, using for instance, high-T(sub c) SNS bridges. We discuss the modifications to the classical RSJ model which are necessary in the quantum regime (h nu greater than kT), and conclude the Josephson mixers may attain noise temperatures less than ten times the quantum limit at high frequencies.

Schoelkopf, R.↗

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

AladynPi – Adaptive Neural Network Molecular Dynamics Simulation Code with Physically Informed Potential: Computational Materials Mini-Application

This report provides an overview and description of commands used in the Computational Materials mini-application, AladynPi. AladynPi is an extension of a previously released mini-application, Aladyn (https://github.com/nasa/aladyn; Yamakov, V.I., and Glaessgen, E.H., NASA/TM-2018-220104). Aladyn and AladynPi are basic molecular dynamics codes written in FORTRAN 2003, which are designed to demonstrate the use of adaptive neural networks (ANNs) in atomistic simulations. The role of ANNs is to efficiently reproduce the very complex energy landscape resulting from the atomic interactions in materials with the accuracy of the more expensive quantum mechanics-based calculations. The ANN is trained on a large set of atomic structures calculated using the density functional theory method. An input for the ANN is a set of structure coefficients, characterizing the local atomic environment of each atom, for which the atomic energy is obtained in the ANN inference process. In Aladyn, the ANN gives directly the energy of interatomic interactions. In AladynPi, the ANN gives optimized parameters for a predefined empirical function, known as bond-order-potential (BOP). The parameterized BOP function is then used to calculate the energy. AladynPi code is being released to serve as a training testbed for students and professors in academia to explore possible optimization algorithms for parallel computing on multicore central processing unit (CPU) computers or computers utilizing manycore architectures based on graphic processing units (GPUs). The effort is supported by the High Performance Computing incubator (HPCi) project at NASA Langley Research Center.

Yamakov, Vesselin I.↗

InGaAs concentrator cells for laser power converters and tandem cells

In(0.53)Ga(0.47)As N-on-P concentrator cells were made as part of an effort to develop 1.315 micron laser power converters. The 1.315 micron laser power conversion efficiency was estimated as 29.4 percent (at 5.57 W/cm(sup 2)) based on an 86 percent measured external quantum efficiency at 1.315 microns, and a measured open circuit voltage (484 mV), and fill-factor (67 percent) at the equivalent AM0 short-circuit photocurrent (5.07 A/cm(sup 2)). A 13.5 percent percent AMO efficiency was achieved at 89 suns and 25 C. Measured one-sun and 100-sun AMO efficiency, log I-V analysis, and quantum efficiency are presented for InGaAs cells with and without InP windows to passivate the front surface. Windowed cells performed better at concentration than windowless cells. Lattice mismatch between InGaAs epilayers and InP substrate was less than 800 ppm. Theoretical efficiency is estimated for 1.315 microns laser power converters versus the bandgap energy. Adding aluminum to InGaAs to form In(x)Al(y)Ga(1-x-y)As is presented as a way to achieve an optimal bandgap for 1.315 microns laser power conversion.

Wojtczuk, S.↗

The Dolinar Receiver in an Information Theoretic Framework

Optical communication at the quantum limit requires that measurements on the optical field be maximally informative, but devising physical measurements that accomplish this objective has proven challenging. The Dolinar receiver exemplifies a rare instance of success in distinguishing between two coherent states: an adaptive local oscillator is mixed with the signal prior to photodetection, which yields an error probability that meets the Helstrom lower bound with equality. Here we apply the same local-oscillator-based architecture with aninformation-theoretic optimization criterion. We begin with analysis of this receiver in a general framework for an arbitrary coherent-state modulation alphabet, and then we concentrate on two relevant examples. First, we study a binary antipodal alphabet and show that the Dolinar receiver's feedback function not only minimizes the probability of error, but also maximizes the mutual information. Next, we study ternary modulation consistingof antipodal coherent states and the vacuum state. We derive an analytic expression for a near-optimal local oscillator feedback function, and, via simulation, we determine its photon information efficiency (PIE). We provide the PIE versus dimensional information efficiency (DIE) trade-off curve and show that this modulation and the our receiver combination performs universally better than (generalized) on-off keying plus photoncounting, although, the advantage asymptotically vanishes as the bits-per-photon diverges towards infinity.

optical communications↗

Development of Large-Scale Magnetic Calorimeter Arrays

We describe performance of large-scale arrays of metallic magnetic calorimeters (MMCs) we are developing to meet requirements of the Lynx X-ray Microcalorimeter (LXM) instrument in the astrophysics mission concept Lynx. We have fabricated prototypes with 55,800 x-ray pixels thermally connected to 5,688 MMC sensors. Subarrays demonstrate three types of pixels, which have different energy and spatial resolution goals in LXM. Pixel pitch is 50 or 25 µm. For two subarrays, use of position sensitive detectors, in a "hydra" configuration with 25 x-ray absorbers per sensor, helps achieve a large focal plane by increasing pixel count relative to readout channels. Since each absorber has a different thermal link to its sensor, it generates a different pulse shape and enables discrimination of pixel position. Superconducting wiring from all sensors was brought out to the perimeter of the overall array using multiple buried metal layers planarized by Chemical Mechanical Planarization to achieve high critical current, low inductance, and high fabrication yield. An automated, algorithmic approach was used to layout the complex wiring pattern. For readout with existing small arrays of Superconducting Quantum Interference (SQUID) amplifiers, 112 selected pixels were connected to wire bond pads. In hydras, we successfully identified 25 pulse shapes using rise-time and pulse height. Pulse shapes were similar to simulations. We measured noise and responsivity to substrate temperature and applied x-ray pulses. While we designed sensors to have high inductance to relative to stray inductance of wiring, we had only mismatched (lower input inductance) SQUIDs available in our current apparatus, giving non-optimized resolution. We compared measured and calculated energy resolutions. We have the required sensitivity to reach < 3 eV FWHM resolution for 6 keV x-rays, required for the LXM Main Array, and the ability to discriminate the 25 different absorber pixels down to energies < 300 eV.

microcalorimeters↗

Near-infrared cathodoluminescence imaging of defect distributions in In(0.2)Ga(0.8)As/GaAs multiple quantum wells grown on prepatterned GaAs

The defect distribution in a highly strained In(0.2)Ga(0.8)As/GaAs multiple-quantum-well (MQW) structure grown on a patterned GaAs substrate is examined with cathodoluminescence imaging and spectroscopy in the near IR. By spatially correlating the luminescence arising from the MQW exciton recombination (950 nm) with the longer wavelength (1000-1200 nm) luminescence arising from the defect-induced recombination, it is demonstrated that it is possible to determine the regions of highest film quality in both the mesa and valley regions. The present approach enables a judicious determination of the optimal regions to be used for active pixels in InGaAs/GaAs spatial light modulators.

Rich, D. H.↗