Aquarius Radiometer Performance: Early On-Orbit Calibration and Results

The Aquarius/SAC-D observatory was launched into a 657-km altitude, 6-PM ascending node, sun-synchronous polar orbit from Vandenberg, California, USA on June 10, 2011. The Aquarius instrument was commissioned two months after launch and began operating in mission mode August 25. The Aquarius radiometer meets all engineering requirements, exhibited initial calibration biases within expected error bars, and continues to operate well. A review of the instrument design, discussion of early on-orbit performance and calibration assessment, and investigation of an on-going calibration drift are summarized in this abstract.

Piepmeier, Jeffrey R.↗

The First SIMBIOS Radiometric Intercomparison (SIMRIC-1), April-September 2001

This report describes the first SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) Radiometric Intercomparison (SIMRIC-1). The purpose of the SIMRIC-1 is to ensure a common radiometric scale of the calibration facilities that are engaged in calibrating in situ radiometers used for ocean color related research and to document the calibration procedures and protocols. SIMBIOS staff visited the seven participating laboratories for at least two days each. The SeaWiFS Transfer Radiometer SXR-II measured the calibration radiances produced in the laboratories. The measured radiances were compared with the radiances expected by the laboratories. Typically, the measured radiances were higher than the expected radiances by 0 to 2%. This level of agreement is satisfactory. Several issues were identified, where the calibration protocols need to be improved, especially the reflectance calibration of the reference plaques and the distance correction when using the irradiance standards at distances greater than the 50 cm. The responsivity of the SXR-II changed between 0.3% (channel 6) and 1.6% (channel 2) from December 2000 to December 2001. Monitoring the SXR-II with a portable light source showed a linear drift of the calibration, except for channel 1, where a 2% drop occurred in summer.

Meister, Gerhard↗

A liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration

Design, radiometric and thermal performance, and operation of a large diameter (78 cm) liquid-helium-cooled blackbody absolute reference cold load (CL) for the calibration of microwave radiometers is described. CL provides an absolute calibration near the liquid-helium (LHe) boiling point, with total uncertainty in the radiometric temperature of less than 30 mK over the 2.5-23 cm wavelength operating range. CL was used at several wavelengths at the South Pole, Antarctica and the White Mountain Research Center, California. Results show that, for the instruments operated at 20-, 12-, 7.9-, and 4.0 cm wavelength at the South Pole, the total corrections to the LHe boiling-point temperature (about 3.8 K) were 48 +/-23, 18 +/-10, 10 +/-18, and 15 +/-mK.

Bensadoun, Marc↗

A Generalized Logical Format for Inter-Calibrated Brightness Temperatures for the Global Precipitation Measurement Mission

An important aspect of the GPM mission is the merging of precipitation data from multiple radiometers on different satellites. This requires that each radiometer be consistently calibrated and that each be intercalibrated with a mission reference standard. For GPM the reference standard is to be the core satellite carrying a dual frequency precipitation radar and a well calibrated conically scanning radiometer. This paper describes a common format for representing these intercalibrated brightness temperatures which will be used for all radiometer products from GPM partner satellites. The use of common formats ensures that users obtain all the required information and also facilitates the rain retrieval algorithm code preparation as it can always except to have the data that it needs for the retrieval.

Stocker, Erich Franz↗

The optics and calibration of the Venus solar flux radiometer

The described instrument is to measure the net solar radiation as a function of altitude as the probe descends through the Venus atmosphere. The data are to provide a basis for the study of the mechanisms which are responsible for the high surface temperature of the planet Venus. The instrument consists of two separate sections, including an optical head and an electronics package. The radiance is measured with silicon and indium arsenide detectors. Details of radiometer design are discussed along with the characteristics of the optical system and the detectors. Angular and radiometric calibration procedures are also considered.

Palmer, J. M.↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Accuracy Assessments and Validation of an Expanded UV Irradiance Database from Satellite Total Ozone Mapping Spectrometer (TOMS)

The TOMS UV irradiance database (1978 to 2000) has been expanded to include 5 new products (noon irradiance at 305, 310, 324, and 380 nm, and noon erythemal-weighted irradiance), in addition to the existing erythemal daily exposure, which permit direct Comparisons with ground-based measurements from UV spectrometers. Sensitivity studies are conducted to estimate uncertainties of the new TOMS UV irradiance data due to algorithm apriori assumptions. Comparisons with Brewer spectrometers as well as filter radiometers are used to review of the sources of known errors. Inability to distinguish between snow and cloud cover using only TOMS data results in large errors in estimating surface UV using snow climatology. A correction is suggested for the case when the regional snow albedo is known from an independent source. The summer-time positive bias between TOMS UV estimations and Brewer measurements can be seen at all wavelengths. This suggests the difference is not related to ozone absorption effects. We emphasize that uncertainty of boundary layer UV aerosol absorption properties remains a major source of error in modeling UV irradiance in clear sky conditions. Neglecting aerosol absorption by the present TOMS algorithm results in a positive summertime bias in clear-sky UV estimations over many locations. Due to high aerosol variability the bias is strongly site dependent. Data from UV-shadow-band radiometer and well-calibrated CIMEL sun-sky radiometer are used to quantify the bias at NASA/GSFC site in Greenbelt, MD. Recommendations are given to enable potential users to better account for local conditions by combining standard TOMS UV data with ancillary ground measurements.

Krotkov, N. A.↗

Radio metric errors due to mismatch and offset between a DSN antenna beam and the beam of a troposphere calibration instrument

Two components of the error of a troposphere calibration measurement were quantified by theoretical calculations. The first component is a beam mismatch error, which occurs when the calibration instrument senses a conical volume different from the cylindrical volume sampled by a Deep Space Network (DSN) antenna. The second component is a beam offset error, which occurs if the calibration instrument is not mounted on the axis of the DSN antenna. These two error sources were calculated for both delay (e.g., VLBI) and delay rate (e.g., Doppler) measurements. The beam mismatch error for both delay and delay rate drops rapidly as the beamwidth of the troposphere calibration instrument (e.g., a water vapor radiometer or an infrared Fourier transform spectrometer) is reduced. At a 10-deg elevation angle, the instantaneous beam mismatch error is 1.0 mm for a 6-deg beamwidth and 0.09 mm for a 0.5-deg beam (these are the full angular widths of a circular beam with uniform gain out to a sharp cutoff). Time averaging for 60-100 sec will reduce these errors by factors of 1.2-2.2. At a 20-deg elevation angle, the lower limit for current Doppler observations, the beam-mismatch delay rate error is an Allan standard deviation over 100 sec of 1.1 x 10(exp -14) with a 4-deg beam and 1.3 x 10(exp -l5) for a 0.5-deg beam. A 50-m beam offset would result in a fairly modest (compared to other expected error sources) delay error (less than or equal to 0.3 mm for 60-sec integrations at any elevation angle is greater than or equal to 6 deg). However, the same offset would cause a large error in delay rate measurements (e.g., an Allan standard deviation of 1.2 x 10(exp -14) over 100 sec at a 20-deg elevation angle), which would dominate over other known error sources if the beamwidth is 2 deg or smaller. An on-axis location is essential for accurate troposphere calibration of delay rate measurements. A half-power beamwidth (for a beam with a tapered gain profile) of 1.2 deg or smaller is desired for calibration of all types of radio metrics. A water-vapor radiometer calibration beam of this size with very low sidelobes would require a clear aperture antenna with a diameter of at least 1.5 m if the primary water vapor sensing channel were in the 20-22 GHz range.

R P Linfield↗

Characterization and Calibration of an AERONET-OC Radiometer

The Ocean Color component of the global Aerosol Robotic Network (AERONET-OC) utilizes CE-318 sun photometers modified for above-water radiometry from fixed structures such as oil rigs, lighthouses and service platforms. Primarily, AERONET-OC measurements allow determination of the water-leaving radiance required for the validation of ocean color satellite data products. In this study, we characterized and calibrated one instrument from the AERONET-OC network, identified as AERONET #080. A laser-illuminated integrating sphere of known radiance enabled determination of the absolute radiance responsivity for 7 bands. We compared the results to calibrations from the AERONET facility at the Goddard Space Flight Center of the National Aeronautics and Space Administration and from the Joint Research Centre of the European Commission. These results agree within the estimated mean comparison uncertainty of 1.88 % (k = 2). We also assessed these results using calibrated lamp-illuminated integrating spheres and observed a spectral dependence to the comparison results that is unexplained.

B. C. Johnson↗

Radiometer Design Analysis Based Upon Measurement Uncertainty

This paper introduces a method for predicting the performance of a radiometer design based on calculating the measurement uncertainty. The variety in radiometer designs and the demand for improved radiometric measurements justify the need for a more general and comprehensive method to assess system performance. Radiometric resolution, or sensitivity, is a figure of merit that has been commonly used to characterize the performance of a radiometer. However when evaluating the performance of a calibration design for a radiometer, the use of radiometric resolution has limited application. These limitations are overcome by considering instead the measurement uncertainty. A method for calculating measurement uncertainty for a generic radiometer design including its calibration algorithm is presented. The result is a generalized technique by which system calibration architectures and design parameters can be studied to optimize instrument performance for given requirements and constraints. Example applications demonstrate the utility of using measurement uncertainty as a figure of merit.

Racette, Paul E.↗

The absolute radiometric calibration of the advanced very high resolution radiometer

The measurement conditions are described for an intensive field campaign at White Sands Missile Range for the calibration of the AVHRRs on NOAA-9, NOAA-10 and NOAA-11, LANDSAT-4 TM and SPOT. Three different methods for calibration of AVHRRs by reference to a ground surface site are reported, and results from these methods are compared. Significant degradations in NOAA-9 and NOAA-10 AVHRR responsivities occurred since prelaunch calibrations were completed. As of February 1988, degradations in NOAA-9 AVHRR responsivities were on the order of 37 percent in channel and 41 percent in channel 2, and for the NOAA-10 AVHRR these degradations were 42 and 59 percent in channels 1 and 2, respectively.

Slater, P. N.↗

Microwave and mm-Wave Radiometry for Earth and Planetary Science

Microwave radiometry has been an indispensable tool for observing Earth and the solar system since the 1960s. On Earth, microwave radiometers are used to observe ocean, land, ice, and atmosphere. Calibrating a microwave radiometer and measuring an LNA noise figure use the same principals. There is opportunity to improve upon the state-of-the-art methods in both space and lab environments by leveraging lessons learned in one for the other.

microwave radiometry↗

Calibration of field reference panel and radiometers used in FIFE 1989

Remote sensing of the earth's surface features involves the measurement of reflected solar radiation and the interpretation of the data in biophysical terms. Reflected radiation is a function of the surface properties and incident solar irradiance. The amount of radiation reflected from a surface is compared to the amount of solar radiation received at the surface as a means of comparing information from different times of day as well as for different days of the year. Thus, it is imperative to calibrate the instruments used to measure the incoming and reflected radiation.

Blad, Blaine L.↗

Validation of a Digital Noise Power Integration Technique for Radiometric Clear Sky Attenuation Estimation at Q-band

This paper presents the validation of a digital signal processing technique that can be used to estimate radiometric sky noise, and hence, atmospheric absorption, within existing digital receivers at little/no additional cost. To demonstrate this, a receiver was constructed that simultaneously records the beacon signal power from the ALPHASAT Aldo Paraboni technology demonstration payload, as well as the integrated noise power in the adjacent band. Calibration from the digital radiometer is performed using tip-curve calibration procedures. Atmospheric fading is then obtained by observing the beacon as well as the radiometric signals. This enables the comparison of fading obtained by the two techniques and provides a means to calibrate the received beacon power level to obtain total atmospheric attenuation. It is shown that for low levels of fading, up to a few dB, the two techniques provide good agreement. This approach can therefore provide a low-cost option for geostationary mmwave satellite channel measurements in the low fading regime, which can be useful in the design and operation of the feeder links in emerging satcom systems.

radiometer↗

Development of a High-Stability Microstrip-based L-band Radiometer for Ocean Salinity Measurements

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This measurement requires the L-band radiometers to have calibration stabilities of less than or equal to 0.05 K over 2 days. This research has focused on determining the optimum radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that allows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and DC bias, system linearity, optimum noise diode injection calibration, and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability.

Pellerano, Fernando A.↗

System calibration of the 1.4 GHz and 5 GHz radiometers for soil moisture remote sensing

Two microwave radiometers at the frequencies of 1.4 GHz and 5 GHz were mounted on a mobile tower and used for a remote sensing of soil moisture experiment at a Beltsville Agriculture Research Center test site. The experiment was performed in October 1979 over both bare field and fields covered with grass, soybean, and corn. The calibration procedure for the radiometer systems which forms the basis of obtaining the final radiometric data product is described. It is estimated from the calibration results that the accuracy of the 1.4 GHz radiometric measurements is about + or - 3 K. The measured 5 GHz brightness temperatures over bare fields with moisture content greater than 10 percent by dry weight are about 8 K lower than those taken simultaneously at 1.4 GHz. This could be due to either (1) a 5 GHz antenna side lobe seeing the cold brightness of the sky, or (2) the thermal microwave emission from a soil being less sensitive to surface roughness at 5 GHz than at 1.4 GHz.

Wang, J.↗