Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Damage Detection in Composite Structures with Wavenumber Array Data Processing

Guided ultrasonic waves (GUW) have the potential to be an efficient and cost-effective method for rapid damage detection and quantification of large structures. Attractive features include sensitivity to a variety of damage types and the capability of traveling relatively long distances. They have proven to be an efficient approach for crack detection and localization in isotropic materials. However, techniques must be pushed beyond isotropic materials in order to be valid for composite aircraft components. This paper presents our study on GUW propagation and interaction with delamination damage in composite structures using wavenumber array data processing, together with advanced wave propagation simulations. Parallel elastodynamic finite integration technique (EFIT) is used for the example simulations. Multi-dimensional Fourier transform is used to convert time-space wavefield data into frequency-wavenumber domain. Wave propagation in the wavenumber-frequency domain shows clear distinction among the guided wave modes that are present. This allows for extracting a guided wave mode through filtering and reconstruction techniques. Presence of delamination causes spectral change accordingly. Results from 3D CFRP guided wave simulations with delamination damage in flat-plate specimens are used for wave interaction with structural defect study.

Tian, Zhenhua↗

Discovery of Rapidly Moving Partial X-Ray Absorbers Within Cassiopeiae

Gamma Cassiopeiae is an enigmatic Be star with unusually strong hard X-ray emission. The Suzaku observatory detected six rapid X-ray spectral hardening events called "softness dips" in a approx.100 ks observation in 2011. All the softness dip events show symmetric softness-ratio variations, and some of them have flat bottoms apparently due to saturation. The softness dip spectra are best described by either approx.40% or approx.70% partial covering absorption to kT approx.12 keV plasma emission by matter with a neutral hydrogen column density of approx.(2−8) ×10(exp 21)/sq cm, while the spectrum outside these dips is almost free of absorption. This result suggests the presence of two distinct X-ray-emitting spots in the gamma Cas system, perhaps on a white dwarf (WD) companion with dipole mass accretion. The partial covering absorbers may be blobs in the Be stellar wind, the Be disk, or rotating around the WD companion. Weak correlations of the softness ratios to the hard X-ray flux suggest the presence of stable plasmas at kT approx 0.9 and 5 keV, which may originate from the Be or WD winds. The formation of a Be star and WD binary system requires mass transfer between two stars; gamma Cas may have experienced such activity in the past.

tars: emission-line↗

Detecting Phycocynanin-Pigmented Microbes in Reflected Light

A recently invented method of measuring concentrations of phycocynanin-pigmented algae and bacteria in water is based on measurement of the spectrum of reflected sunlight. When present in sufficiently high concentrations, phycocynanin-pigmented microorganisms can be hazardous to the health of humans who use, and of animals that depend on, an affected body of water. The present method is intended to satisfy a need for a rapid, convenient means of detecting hazardous concentrations of phycocynanin-pigmented microorganisms. Rapid detection will speed up the issuance of public health warnings and performance of corrective actions. The method involves the measurement of light reflected from a body of water in at least two, but preferably five wavelength bands. In one version of the method, the five wavelength bands are bands 1, 3, 4, 5, and 7 of the Thematic Mapper (TM) multispectral imaging instrument aboard the Landsat-7 satellite (see table). In principle, other wavelength bands indicative of phycocynanin could be used alternatively or in addition to these five. Moreover, although the method was originally intended specifically for processing Landsat- 7 TM data, it is equally applicable to processing of data from other satellite-borne instruments or from airborne, hand-held, buoy-mounted, tower-mounted, or otherwise mounted instruments that measure radiances of light reflected from water in the wavelength bands of interest.

Vincent, Robert K.↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

Microelectronic DNA assay for the detection of BRCA1 gene mutations

Mutations in BRCA1 are characterized by predisposition to breast cancer, ovarian cancer and prostate cancer as well as colon cancer. Prognosis for this cancer survival depends upon the stage at which cancer is diagnosed. Reliable and rapid mutation detection is crucial for the early diagnosis and treatment. We developed an electronic assay for the detection of a representative single nucleotide polymorphism (SNP), deletion and insertion in BRCA1 gene by the microelectronics microarray instrumentation. The assay is rapid, and it takes 30 minutes for the immobilization of target DNA samples, hybridization, washing and readout. The assay is multiplexing since it is carried out at the same temperature and buffer conditions for each step. The assay is also highly specific, as the signal-to-noise ratio is much larger than recommended value (72.86 to 321.05 vs. 5) for homozygotes genotyping, and signal ratio close to the perfect value 1 for heterozygotes genotyping (1.04).

Validation Studies↗

CONGO²: Scalable Online Anomaly Detection and Localization in Power Electronics Networks

Rapid and accurate detection and localization of electronic disturbances simultaneously are important for preventing its potential damages and determining potential remedies. Existing anomaly detection methods are severely limited by the low accuracy, the expensive computational cost and the need for highly trained personnel. There is an urgent need for a scalable online algorithm for in-field analysis of large-scale power electronics networks. Here in this paper, we propose a fast and accurate algorithm for anomaly detection and localization of power electronics networks: stratified colored-node graph (CONGO2). This algorithm hierarchically models the change of correlated waveforms and then correlated sensors using the colored-node graph. By aggregating the change of each sensor with its neighbors’ inputs, we can spontaneously identify and localize the anomaly that cannot be detected by data collected from a single sensor. As our proposed method only focuses on the changes within a short time frame, it is highly computational efficient and only needs small data storage. Thus, our method is ideal for online and reliable anomaly detection and localization of large-scale power electronic networks. Compared to existing anomaly detection methods, our method is entirely data-driven without training data, highly accurate and reliable for wide-spectrum anomalies detection, and more importantly, capable of both detection and localization. Thus, it is ideal for infield deployment for large-scale power electronic networks. As illustrated by a distributed energy resources (DERs) power grid with 37-node, our method can effectively detect and localize various cyber and physical attacks.

42 ENGINEERING↗

Automatic Detection and Classification of Radio Galaxy Images by Deep Learning

Abstract Surveys conducted by radio astronomy observatories, such as SKA, MeerKAT, Very Large Array, and ASKAP, have generated massive astronomical images containing radio galaxies (RGs). This generation of massive RG images has imposed strict requirements on the detection and classification of RGs and makes manual classification and detection increasingly difficult, even impossible. Rapid classification and detection of images of different types of RGs help astronomers make full use of the observed astronomical image data for further processing and analysis. The classification of FRI and FRII is relatively easy, and there are more studies and literature on them at present, but FR0 and FRI are similar, so it is difficult to distinguish them. It poses a greater challenge to image processing. At present, deep learning has made breakthrough progress in the field of image analysis and processing and has preliminary applications in astronomical data processing. Compared with classification algorithms that can only classify galaxies, object detection algorithms that can locate and classify RGs simultaneously are preferred. In target detection algorithms, YOLOv5 has outstanding advantages in the classification and positioning of small targets. Therefore, we propose a deep-learning method based on an improved YOLOv5 object detection model that makes full use of multisource data, combining FIRST radio with SDSS optical image data, and realizes the automatic detection of FR0, FRI, and FRII RGs. The innovation of our work is that on the basis of the original YOLOv5 object detection model, we introduce the SE Net attention mechanism, increase the number of preset anchors, adjust the network structure of the feature pyramid, and modify the network structure, thereby allowing our model to demonstrate galaxy classification and position detection effects. Our improved model produces satisfactory results, as evidenced by experiments. Overall, the mean average precision (mAP@0.5) of our improved model on the test set reaches 89.4%, which can determine the position (R.A. and decl.) and automatically detect and classify FR0s, FRIs, and FRIIs. Our work contributes to astronomy because it allows astronomers to locate FR0, FRI, and FRII galaxies in a relatively short time and can be further combined with other astronomically generated data to study the properties of these galaxies. The target detection model can also help astronomers find FR0s, FRIs, and FRIIs in future surveys and build a large-scale star RG catalog. Moreover, our work is also useful for the detection of other types of galaxies.

Astronomy & Astrophysics↗

Smartphone-Based Device for Colorimetric Detection of MicroRNA Biomarkers Using Nanoparticle-Based Assay

The detection of microRNAs (miRNAs) is emerging as a clinically important tool for the non-invasive detection of a wide variety of diseases ranging from cancers and cardiovascular illnesses to infectious diseases. Over the years, miRNA detection schemes have become accessible to clinicians, but they still require sophisticated and bulky laboratory equipment and trained personnel to operate. The exceptional computing ability and ease of use of modern smartphones coupled with fieldable optical detection technologies can provide a useful and portable alternative to these laboratory systems. Herein, we present the development of a smartphone-based device called Krometriks, which is capable of simple and rapid colorimetric detection of microRNA (miRNAs) using a nanoparticle-based assay. The device consists of a smartphone, a 3D printed accessory, and a custom-built dedicated mobile app. We illustrate the utility of Krometriks for the detection of an important miRNA disease biomarker, miR-21, using a nanoplasmonics-based assay developed by our group. We show that Krometriks can detect miRNA down to nanomolar concentrations with detection results comparable to a laboratory-based benchtop spectrophotometer. With slight changes to the accessory design, Krometriks can be made compatible with different types of smartphone models and specifications. Thus, the Krometriks device offers a practical colorimetric platform that has the potential to provide accessible and affordable miRNA diagnostics for point-of-care and field applications in low-resource settings.

Krishnan, Tushar (ORCID:0000000342610336)↗

An expert system for fault diagnosis in a Space Shuttle main engine

The detection and diagnosis of SSME faults in an early stage is important in order to allow enough time for fault preventive or corrective measurements. Since most of the faults in a complex system like SSME develop rapidly, early detection and diagnosis of faults is critical for the survival of space vehicles. An expert system has been designed for automatic learning, detection, identification, verification, and correction of anomalous propulsion system operations. This paper describes an innovative machine learning approach which is employed for the automatic training of this expert system.

Ali, Moonis↗

Aerosol Chemical Speciation Monitor (ACSM) Composition-Dependent Collection Efficiency (CDCE) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform that measures many of these aerosol properties in situ. The Aerodyne aerosol chemical speciation monitor (ACSM) is a baseline instrument deployed in the AOS. The ACSM provides a quantitative measurement of aerosol particle chemical composition for non-refractory (operationally defined as components that evaporate on the 600ºC vaporizer) aerosol components in real time. Standard output is the mass concentration of particulate organics, nitrate, sulfate, chloride, and ammonium. One well-known limitation to the accuracy of the ACSM data is in evaluating the fraction of the ambient aerosol particles that are detected by the instrument. This quantity is referred to as the collection efficiency (CE) and is often less than unity. This is attributed to particles rebounding after impaction onto the heated vaporizer rather than being trapped, volatilized rapidly, and detected. Other factors, such as divergence of the aerosol particle beam, may also impact CE, but the particle rebound effect is the dominant factor. Scientists will sometimes assume CE = 0.5 (i.e., one half of sampled particles are detected) for ambient particles collected during field missions. However, parameterizations have been developed that express CE as a function of the measured chemical composition, referred to as the composition-dependent collection efficiency (CDCE). The physical explanation for a CDCE, supported by laboratory studies, is that rebound from the vaporizer is a function of the particle phase, with liquid-like particles “sticking” to the vaporizer and solid-like or crystalline particles “bouncing” from the vaporizer. Thus, particles with compositions are liquids-like under the measurement conditions (e.g., certain organics, acidic particles, particles enriched in nitrate) have CE close to unity while crystalline or solid particles (e.g., deliquesced ammonium sulfate) have lower CE. This value-added product (VAP) implements the procedure described by Middlebrook et al. (2012) to correct the ACSM data for the composition-dependent collection efficiency. Applying this parameterization improves the accuracy of the ACSM data and brings them into better agreement with other co-located aerosol measurements.

54 ENVIRONMENTAL SCIENCES↗

Kilonova Detectability with Wide-field Instruments

Abstract Kilonovae are ultraviolet, optical, and infrared transients powered by the radioactive decay of heavy elements following a neutron star merger. Joint observations of kilonovae and gravitational waves can offer key constraints on the source of Galactic r -process enrichment, among other astrophysical topics. However, robust constraints on heavy element production require rapid kilonova detection (within ∼1 day of merger) as well as multiwavelength observations across multiple epochs. In this study, we quantify the ability of 13 wide-field-of-view instruments to detect kilonovae, leveraging a large grid of over 900 radiative transfer simulations with 54 viewing angles per simulation. We consider both current and upcoming instruments, collectively spanning the full kilonova spectrum. The Roman Space Telescope has the highest redshift reach of any instrument in the study, observing kilonovae out to z ∼ 1 within the first day post-merger. We demonstrate that BlackGEM, DECam, GOTO, the Vera C. Rubin Observatory’s LSST, ULTRASAT, VISTA, and WINTER can observe some kilonovae out to z ∼ 0.1 (∼475 Mpc), while DDOTI, MeerLICHT, PRIME, Swift/UVOT, and ZTF are confined to more nearby observations. Furthermore, we provide a framework to infer kilonova ejecta properties following nondetections and explore variation in detectability with these ejecta parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Utilization of Data Augmentation Techniques in Automated Inspection Systems for Defect Detection in Metals With Limited Data

Accurate identification of defects on metal surfaces is of great interest to many industry sectors, such as the automotive and aerospace industries. In contrast to conventional manual inspection techniques, recent automated inspection systems employ deep learning models trained to detect defects rapidly and precisely. The development of these models often requires a substantial image dataset to acquire adequate knowledge of defect features and enhance their predictive accuracy. When data is limited, augmentation techniques are often used to improve the precision and accuracy of defect detection systems. This study examined the prediction performance of two object detection models, namely Faster Region‐based Convolutional Neural Network (Faster R‐CNN) and You Only Look Once version 8 (YOLOv8), to identify dent defects in limited images of cast iron cylinder head surfaces. The original image set contains 46 images with 563 dents. To overcome limited data availability, common image augmentation techniques along with a copy‐paste method were applied. Results show that standard augmentation improved YOLOv8 accuracy by 8.00% and average precision (AP) by 3.00%. On the other hand, the copy‐paste technique achieved a 20.00% increase in accuracy and a 1% increase in AP with just 200 synthetic dents. Furthermore, these results provide support for using the copy‐paste augmentation strategy to enhance defect detection performance, with a limited dataset, contributing to more accurate defect identification in remanufacturing processes.

36 MATERIALS SCIENCE↗

Deep learning models map rapid plant species changes from citizen science and remote sensing data

Anthropogenic habitat destruction and climate change are reshaping the geographic distribution of plants worldwide. However, we are still unable to map species shifts at high spatial, temporal, and taxonomic resolution. Here, we develop a deep learning model trained using remote sensing images from California paired with half a million citizen science observations that can map the distribution of over 2,000 plant species. Our model— Deepbiosphere— not only outperforms many common species distribution modeling approaches (AUC 0.95 vs. 0.88) but can map species at up to a few meters resolution and finely delineate plant communities with high accuracy, including the pristine and clear-cut forests of Redwood National Park. These fine-scale predictions can further be used to map the intensity of habitat fragmentation and sharp ecosystem transitions across human-altered landscapes. In addition, from frequent collections of remote sensing data, Deepbiosphere can detect the rapid effects of severe wildfire on plant community composition across a 2-y time period. These findings demonstrate that integrating public earth observations and citizen science with deep learning can pave the way toward automated systems for monitoring biodiversity change in real-time worldwide.

Gillespie, Lauren E.↗

Microbial potentiometric sensor technology for real-time detecting and monitoring of toxic metals in aquatic matrices

Considering that toxic metals can affect metabolic processes in microorganisms adversely, it can be hypothesized that these metals in water matrices would induce a decrease in metabolic activity of the biofilm microorganisms populating the surface of a sensing electrode, which could be registered as a change in the open-circuit potential (OCP) generated by the biofilm microorganisms. The goal of this study was to test this hypothesis and demonstrate the underlying principle that microbial potentiometric sensor (MPS) technology could be used for long-term and real-time monitoring and detection of rapid changes in metal concentrations in realistic aquatic environments. To address the goal, four objective were addressed: (1) a batch reactor with three graphite-based MPS electrodes was fabricated; (2) a set of single-ion solutions and one multiple ion solution were prepared reflecting realistic concentrations of metals found in electroplating wastewaters; (3) the responses of the MPS to the simultaneous presence of multiple toxic metal ions in a single solution were measured; and (4) the changes of the MPS signals to the presence of individual metal ion solutions were examined. While the hypothesis was validated, the study also revealed that the MPS was sufficiently sensitive to not only detect, but also quantify, toxic metal ion concentrations in aqueous solutions. The coefficients of determination, which were R 2 > 0.995, and responsiveness of <1 μmol/L for some toxic metal cations, strongly support the performance of MPS technology in the echelons of expensive analytical tools capable detecting and measuring trace elements.The magnitude of the MPS response was toxic metal specific. When the molar concertation normalizes the inhibition portion of the signal area, the assessed sensitivity order was: Se>Cd>Pb>Ag>Ni> Zn. The study provides valuable information for enforcement agents, environmental professionals, and wastewater treatment operators, so toxic metal pollution and its detrimental impacts can be prevented and mitigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

RFI at L-band in Synthetic Aperture Radiometers

The spectral window at 1.413 GHz (L-band), set aside for passive use only, is critical for passive remote sensing of the earth from space. It is the largest spectral window available in the long wavelength end of the microwave spectrum where measurements are needed to monitor parameters of the surface such as soil moisture and sea surface salinity. The sensitivity to these parameters is rapidly lost at higher frequencies and is compromised by the ionosphere and antenna size at lower frequencies. Instruments for remote sensing from space in this spectral window are being developed by NASA (Aquarius) and ESA (SMOS) and are expected to be in orbit in a few years (2006). Although the band at 1.413 GHz is protected for passive use, RFI is a common problem. For example, the synthetic aperture radiometer, ESTAR (L-band, Horizontal polarization), has frequently experienced problems with RFI. During the Southern Great Plains Experiments (1997 and 1999), ESTAR experienced RFI significant enough to warrant changes in flight lines. The largest sources of RFI were identified as originating in airports and a likely source is air traffic control radar. In experiments in the vicinity of Richmond, VA, RFI in the form of periodic spikes was recorded, again suggestive of radar. However, in most cases the sources of the RFI are unknown. RFI is a sufficiently common problem that the first step in processing ESTAR data is a screening for RFI (a filter is used to detect large, rapid changes in brightness). Recently, measurements have been made with a new synthetic aperture radiometer, 2D-STAR. Examples of RFI observed simultaneously with ESTAR and the new synthetic aperture radiometer will be presented. 2D-STAR is an airborne instrument designed to develop the technology of aperture synthesis in two dimensions. It employs dual polarized patch antennas arranged in a cross configuration (+). Synthesis in two dimensions offers the potential for optimal thinning, but because of the wide field of view of the individual antennas it is potentially more susceptible to RFI. The 2D-STAR instrument was flown together with ESTAR in a series of test flights on the NASA P-3 aircraft near the Wallops Flight Facility during the summer of 2002. Both instruments experienced RFI over common locations. Examples will be presented and a comparison between instruments presented.

LeVine, David M.↗

Validation, Comparison, and Integration of GOCI, AHI, MODIS, MISR, and VIIRS Aerosol Optical Depth Over East Asia During the 2016 KORUS-AQ Campaign

Recently launched multichannel geostationary Earth orbit (GEO) satellite sensors, such as the Geostationary Ocean Color Imager (GOCI) and the Advanced Himawari Imager (AHI), provide aerosol products over East Asia with high accuracy, which enables the monitoring of rapid diurnal variations and the transboundary transport of aerosols. Most aerosol studies to date have used low Earth orbit (LEO) satellite sensors, such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Multi-angle Imaging Spectroradiometer (MISR), with a maximum of one or two overpass daylight times per day from midlatitudes to low latitudes. Thus, the demand for new GEO observations with high temporal resolution and improved accuracy has been significant. In this study the latest versions of aerosol optical depth (AOD) products from three LEO sensors – MODIS (Dark Target, Deep Blue, and MAIAC), MISR, and the Visible/Infrared Imager Radiometer Suite (VIIRS), along with two GEO sensors (GOCI and AHI), are validated, compared, and integrated for a period during the Korea–United States Air Quality Study (KORUS-AQ) field campaign from 1 May to 12 June 2016 over East Asia. The AOD products analyzed here generally have high accuracy with high R (0.84–0.93) and low RMSE (0.12–0.17), but their error characteristics differ according to the use of several different surface-reflectance estimation methods. High-accuracy near-real-time GOCI and AHI measurements facilitate the detection of rapid AOD changes, such as smoke aerosol transport from Russia to Japan on 18–21 May 2016, heavy pollution transport from China to the Korean Peninsula on 25 May 2016, and local emission transport from the Seoul Metropolitan Area to the Yellow Sea in South Korea on 5 June 2016. These high-temporal-resolution GEO measurements result in more representative daily AOD values and make a greater contribution to a combined daily AOD product assembled by median value selection with a 0.5∘×0.5∘ grid resolution. The combined AOD is spatially continuous and has a greater number of pixels with high accuracy (fraction within expected error range of 0.61) than individual products. This study characterizes aerosol measurements from LEO and GEO satellites currently in operation over East Asia, and the results presented here can be used to evaluate satellite measurement bias and air quality models.

Myungje Choi↗

Shot‐Noise‐Driven Macroscopic Vibrations and Displacement Transduction in Quantum Tunnel Junctions

Back‐action is an inevitable result of quantum measurement. Although the microscopic impacts of shot‐noise back‐action have been explored, macroscopic evidence is seldom documented, especially in the field of electrical transport. Tunneling shot‐noise has been shown to excite the fundamental flexural mode of the host crystal using a sub‐GHz lumped‐element radio‐frequency quantum point contact (QPC). Here, in this study, this aspect of shot‐noise back‐action is examined at much higher operational frequencies and wider bandwidths by employing a GaAs QPC integrated into a planar superconducting cavity within the circuit‐QED framework, leading to the observation of the excitation of multiple mechanical modes. The device operates in the shot‐noise‐limited regime. Constructed on a piezoelectric platform, there is positive feedback between the electrical and mechanical degrees of freedom within the QPC. Shot‐noise excites piezoelectric vibrational modes; concurrently the resulting polarization charges enhance tunneling and develop peaks in the shot‐noise spectra at the modal frequencies. The excitation of vibrational modes is a macroscopic demonstration of measurement back‐action, and the amplitudes of the noise‐peaks enable us to calibrate the displacement sensitivity of the QPC‐resonator systems, which is in the range $≈ 35 fm/√ Hz$, making it an excellent sensor for ultra‐sensitive and rapid strain/displacement detection.

Kumbhakar, Prasanta [Indian Institute of Science E↗