Conceptual design of a high reactive-power ferroelectric fast reactive tuner

We present a novel design of a ferroelectric fast reactive tuner (FE-FRT) capable of modulating mega-VAR reactive power on a submicrosecond timescale. The high reactive power capability of our design extends the range of applications of reactive tuners to numerous applications. We present a detailed analytical model of the performance of a megawatt-class reactive power device and benchmark it against finite-element method eigenmode and frequency domain electromagnetic simulations. We introduce new features, including an annulus design for the ferroelectric capacitors and capacitive window coupling to the cavity. We consider thermal design issues and nonlinear effects in the ferroelectric. The model covers several configurations, allowing control of the frequency of superconducting and normal-conducting cavities in a variety of applications and frequencies. We calculate that the FE-FRT designed should be capable of handling around 0.45 MVAR of reactive power with around 3 kW of resistive losses, providing a frequency tuning range of 8 kHz in an example of 400 MHz cavity geometry. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Experimental Characterization of Hydrocarbons and Nitrogen Oxides Production in a Heavy-Duty Diesel–Natural Gas Reactivity-Controlled Compression Ignition Engine

Reactivity-Controlled Compression Ignition (RCCI) combustion is considered one of the most promising Low-Temperature Combustion (LTC) concepts aimed at reducing greenhouse gases for the transportation and power generation sectors. Due to the spontaneous combustion of a lean, nearly homogeneous mixture of air and low-reactivity fuel (LRF), ignited through the direct injection of a small quantity of high-reactivity fuel (HRF), RCCI (dual-fuel) shows higher efficiency and lower pollutants compared to conventional diesel combustion (CDC) if run at very advanced injection timing. Even though a HRF is used, the use of advanced injection timing leads to high ignition delays, compared to CDC, and generates high cycle-to-cycle variability, limited operating range, and high pressure rise rates at high loads. This work presents an experimental analysis performed on a heavy-duty single-cylinder compression ignited engine in dual-fuel diesel–natural gas mode. The objective of the present work is to investigate and highlight the correlations between combustion behavior and pollutant emissions, especially unburned hydrocarbons (HC) and oxides of nitrogen (NOx). Based on the analysis of crank-resolved pollutants measurements performed through fast FID and fast NOx systems under different engine operating conditions, two correlations were found demonstrating a good accordance between pollutant production and combustion behavior: Net Cyclic Hydrocarbon emission—cyclic IMEP variations (R 2 = 0.86), and Cyclic NOx—maximum value of the Rate of Heat Released (R 2 = 0.82).

33 ADVANCED PROPULSION SYSTEMS↗

Comparing Control Performance Between Simulation and Experiment using the Microreactor Automated Control System Testbed

In the advanced reactor domain, a flexible and scalable software/hardware infrastructure is crucial for integrating and validating various control technologies. This study used the Microreactor Automated Control System (MACS) hardware platform as a testbed. MACS was originally designed to mirror Idaho National Laboratory (INL)'s Microreactor Applications Research Validation and Evaluation (MARVEL), a 85-kW thermal fission microreactor. It features control drums for simulated reactivity control; lights that function as a surrogate reactor core, with the brightness being proportional to the reactor power; and light sensors that emulate neutron detectors. To transform MACS into a physical twin of MARVEL for evaluating control methods, the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software was employed. This software integrated the hardware with two models of the MARVEL core, based on Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The study aimed to demonstrate the gap between control theory and actual practice—a gap that often necessitates empirical adjustments such as control gain retuning, filters, time discretization, and integrator anti-windup measures. Controllers were developed based on increasingly complex simulations without hardware, starting from the base MARVEL model and then introducing actuator saturation constraints and sensor noise. The final control strategy was then tested using MACS, and a comparative performance analysis was conducted.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A Zonal Volt/VAR Control Mechanism for High PV Penetration Distribution Systems

This paper presents a zonal Volt/VAR control scheme for regulating voltage in unbalanced 3-phase distribution systems using inverter-based resources (IBR). First, the dependency between nodal voltage changes and IBR reactive power injections is derived via voltage sensitivity studies. Then, a fast-incremental clustering method is used to divide the distribution circuit into weakly-coupled zones based on correlations between nodal voltage sensitivities. The weak-coupling allows the voltage to be regulated independently within each zone using a rule-based voltage controller to dispatch IBR for voltage corrections. Simulation results on actual distribution feeder show that the proposed zone-based Volt/VAR control method maintains system voltages within their operational limits while reducing the runtime of the Volt/VAR controller from tens of second to a couple of milliseconds compared with centralized, optimization-based Volt/VAR control methods.

Alrushoud, Asmaa↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters

As increasingly more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMS) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; altogether, the control algorithms seamlessly connect the states into a generic microgrid EMS that controls the nodal voltages and frequencies, becomes a virtual power plant (VPP) when connected to the main grid, and coordinates power sharing responsibility among GFM sources when islanded. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management systems↗

Summary of GNU Octave Lady Godiva Simulator

A pseudo real-time interactive reactor simulator for the Lady Godiva reactor has been developed using the GNU Octave software package. The simulator tracks the time-dependent power and fuel temperature behavior of the Lady Godiva reactor during sub-prompt critical transients. Users interact with the simulator by controlling reactivity input. This input occurs through users repositioning a control rod as desired during simulator operation. Various reactor parameters are displayed graphically in near “real time,” facilitating user assessment and feedback input. The reactor model consists of a lumped-fuel core, a single control rod, and a simple heat transfer mechanism that allows heat to be rejected from the core. The goal of the simulator is to demonstrate in real-time the system response to reactivity perturbations, the effect of reactivity feedback, and the effect of temperature-dependent equilibrium conditions. The dynamic behavior of the reactor is primarily driven by the relative characteristic time-constants between the delayed neutrons and the overall heat transfer parameter. The simulator will allow users to gain experience performing standard reactor operations, such as establishing steady-state at different fuel temperatures and making power level changes

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Efficient Phasor-Based Dynamic Volt/VAr and Volt/Watt Analysis of Large Distribution Grid with High Penetration of Smart Inverters

As the penetration of power-electronics based smart inverters (SIs) is increasing in distribution grids, it adds computational challenges in solving dynamic models of large-scale distribution feeders. Voltage and reactive power (Volt/VAr), and voltage and active power (Volt/Watt) dynamics have been analyzed at slower time scales akin to the control of legacy grid devices. However, smart inverters, being power-electronics based devices, can provide dynamic active/reactive power support at a faster time scale, which necessitates Volt/VAr and Volt/Watt dynamics to be analyzed at a faster time scale. The existing dynamic models are overly detailed and computationally intractable for distribution feeders with a large number of inverters. In this context, this proposed work aims towards developing a computationally tractable, scalable, and accurate phasor-based model for dynamic Volt/VAr and Volt/Watt analyses of large distribution systems with high penetration of smart inverters. Case studies demonstrate that the proposed phasor-based model sufficiently captures the Volt/VAr and Volt/Watt dynamics, and is computationally faster by one order of magnitude compared to the average model and by two orders of magnitude compared to the detailed switching model. Case studies also demonstrate the efficacy and scalability of the proposed model in analyzing Volt/VAr and Volt/Watt dynamics of large-scale power networks with hundreds of SIs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rotated-Droop Control for Enhanced Stability and Power Decoupling in Microgrids With Complex Line Impedances

Classical droop control in microgrids predominantly assumes inductive line impedance, which simplifies implementation but causes power coupling and steady-state errors in systems with resistive and inductive lines. This paper proposes a rotated-droop control strategy for grid-forming inverters that reformulates the power equations by incorporating the magnitude and angle of the line impedance within a rotated reference frame. This method enhances the decoupling of active and reactive power dynamics without increasing complexity or requiring communication links. A small-signal state-space model was created to capture the dynamic behavior of the system under varying impedance parameters, preserving the original droop gains by rotating the power control structure. This allows eigenvalue-based stability analysis and enhances damping and transient performance. Simulation and experimental results validated the improved power-sharing performance, faster response, and robustness of the proposed method under different impedance conditions. This approach maintains the decentralized structure of the conventional droop control while enabling greater adaptability and scalability, making it suitable for modern inverter-based microgrids with dynamic topologies.

Campo-Ossa, Daniel Dario [Univ. of Puerto Rico, Ag↗

Volt-VAR Optimization in Distribution Networks Using Twin Delayed Deep Reinforcement Learning

Modern distribution grids are undergoing new challenges due to the stochastic nature of distributed energy resources (DERs). High penetration of DERs has a significant impact on Volt-VAR profile and system power losses. This work proposes a deep reinforcement learning (DRL)-based Volt-VAR optimization approach for improving voltage profile and reducing system power loss under high penetration of distributed energy resources, such as battery energy storage and solar photovoltaic units in distribution grids. The twin delayed deep deterministic policy gradient (TD3) method-based DRL agent is proposed to configure optimal set-points of reactive power outputs of fast responding smart inverters. The agent schedules the reactive power of inverters according to their physical capabilities, such as minimum allowed power factor, e.g., 0.9 leading/lagging. The reward function of the proposed DRL scheme is designed carefully to ensure a proper voltage profile of the grids with effective scheduling of reactive power outputs from inverters. The performance of the proposed model is verified on modified IEEE 34- and 123-bus systems and compared with base case with no reactive supply by inverters, and local droop Volt-VAR control approach. The results show that the proposed method performs better than the local droop control and deep deterministic policy gradient (DDPG)-based DRL method for reducing voltage fluctuation and minimizing power loss.

Hossain, Rakib↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diversity in Photoprotection and Energy Balancing in Terrestrial and Aquatic Phototrophs

The evolution of oxygenic photosynthesis enabled organisms to use sunlight as an energy source, allowing them to colonize new niches. At the same time, life (as we know it) places severe constraints on photosynthesis. For example, the initial reactions of photosynthesis involve highly energetic intermediates that, if not controlled, can generate highly toxic side products (especially reactive oxygen species, ROS), that can damage other essential components of the organisms it powers. Photosynthesis must therefore be tightly regulated to balance the need for efficient energy conversion with the necessity of avoiding photodamage (Gust D, Kramer D, Moore A, Moore T, Vermaas W, Mater Res Bull 33:383–389, 2008). A related constraint on photosynthesis is the need to precisely balance how much energy is stored in ATP and NADPH to precisely meet biochemical demands. If this balancing does not occur, the system will fail, leading to photodamage (Kramer DM, Evans JR, Plant Physiol 155:70–78, 2011). Consideration of these requirements is essential for efforts to improve the efficiency of photosynthesis by introducing CO 2 concentrating mechanisms, altering metabolism or biosynthetic pathways to shunt energy to alternative products (Kramer DM, Evans JR, Plant Physiol 155:70–78, 2011). These balancing processes must be extremely robust to contend with the rapid and unpredictable fluctuations in environmental conditions and metabolic demands that occur in nature. A large body of work has come from model systems, especially terrestrial higher plants and the green alga Chlamydomonas reinhardtii, leading to a model for the regulation of light reactions that involves 1) sensing of the pH gradient component of the thylakoid proton motive force (pmf), and 2) the redox state of the plastoquinone- and stromal pools. Over the short term, these sensors trigger regulation of light capture by altering the activity of ATP synthase leading to adjustments in lumen pH, which fine tunes light capture through nonphotochemical quenching (NPQ) and control of electron flow by adjusting the rate of PQH 2 oxidation at the b 6 f complex. Simultaneously, this system controls the balance of ATP/NADPH by adjusting electron flux to linear and cyclic electron flow pathways to balance ATP/NADPH. This integrated “pmf paradigm” model explains much of the existing data on plants and green algae, but may not extend to other diverse organisms. This review considers how advances in our understanding of photosynthesis over the past 7–8 years, particularly in the discoveries of diverse biochemical/biophysical mechanisms in aquatic photosynthetic species, affects the view of energy balance, including the shunting of electrons to O 2 through the flavodiiron proteins (FLV), the plastid terminal oxidase, the dissipation of electric field by ion movements, and the activation of alternative electron sinks. Furthermore, we will introduce the basic model that has been developed for higher plant chloroplasts, then contrast these with selected aquatic systems, focusing on how the differences impact the needs to re-balance both energy input and its partitioning into energy currencies.

Kanazawa, Atsuko↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗

Transformational challenge reactor analysis to inform preconceptual core design decisions: Sensitivity study of transient analysis in a hydride-moderated microreactor

The Transformational Challenge Reactor (TCR) program aims to demonstrate a revolutionary design approach enabled by advanced manufacturing and data analytics in the design of nuclear reactors. This article discusses scoping analyses of preconceptual designs to inform TCR design decisions and the evaluation of sensitivities and uncertainties on postulated transient scenarios. The applicability of the systems codes TRACE and RELAP5-3D to TCR transient analysis are examined, and RELAP5-3D models are used to examine the transient response of two candidate core designs at multiple power levels. Then, the uncertainty quantification code RAVEN is used to quantify the effect of several design parameters on reactivity-initiated accident (RIA) progression at hot zero power (HZP) and hot full power (HFP) as well as to assess the impact of uncertainties in transient parameters for the pressurized loss of forced cooling (PLOFC).When results were compared, TRACE and RELAP5-3D showed good agreement in their ability to predict system behavior, but RELAP5-3D calculations were closer to analytical predictions for the RIA. Furthermore, models for a PLOFC accident in two designs (a UO2 and TRISO core) at multiple power levels showed greater temperature margins for the TRISO core at all power levels. Using this information, along with other scoping analyses and constraints, the TCR design team selected a power level of 3 MWth and a TRISO-based core design. For this design RAVEN was applied to vary RIA parameters in RELAP5-3D models at HZP and HFP to understand the effect on figures of merit such as peak power, fuel and coolant temperature, and energy deposition. This sensitivity study found that the inserted reactivity worth was the most important parameter controlling all figures of merit, but for insertion up to 1.5$ no failure of TCR fuel is anticipated. For constant reactivity insertions, the magnitude of the fuel temperature coefficient was found to have the greatest effect on all figures of merit under most circumstances. These results not only demonstrate the anticipated robust safety of the proposed TCR fuel form but also provide a reference for future metal-hydride moderated systems to understand RIA behavior. In the PLOFC, the impact of heat transfer enhancement due to wavy flow channel effects dominated the variance in peak temperatures, and variations in heat exchanger elevation provided the greatest control on natural circulation flow rate. Additionally, no fuel particle failure is anticipated in the PLOFC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and↗

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗