Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Optimal sampling and sensitivity limits of integrating detector arrays in a space environment

The performance of integrating detectors with either destructive read-out or nondestructive direct read-out in a space environment subject to charge-particle and radiation hits was investigated by determining the optimal integration time for maximizing the performance in the presence of a given hit rate. The performance relative to that expected for background-limited performance was evaluated using a combination of analytic techniques and Monte Carlo simulations. Results are used to estimate the performance degradation, due to cosmic rays, of the long-wavelength spectrometer of the Space Infrared Telescope Facility. It was found that its performance may be a factor of 1-5 worse than the background limited performance.

Herter, T.↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Champey, Patrick↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Camera↗

Optimizing Lossy Compression Rate-Distortion from Automatic Online Selection between SZ and ZFP

With ever-increasing volumes of scientific data produced by high-performance computing applications, significantly reducing data size is critical because of limited capacity of storage space and potential bottlenecks on I/O or networks in writing/reading or transferring data. SZ and ZFP are two leading BSD licensed open source C/C++ libraries for compressed floating-point arrays that support high throughput read and write random access. However, their performance is not consistent across different data sets and across different fields of some data sets, which raises the need for an automatic online (during compression) selection between SZ and ZFP, with minimal overhead. In this paper, the automatic selection optimizes the rate-distortion, an important statistical quality metric based on the signal-to-noise ratio. To optimize for rate-distortion, we investigate the principles of SZ and ZFP. We then propose an efficient online, low-overhead selection algorithm that predicts the compression quality accurately for two compressors in early processing stages and selects the best-fit compressor for each data field. Here, we implement the selection algorithm into an open-source library, and we evaluate the effectiveness of our proposed solution against plain SZ and ZFP in a parallel environment with 1,024 cores. Evaluation results on three data sets representing about 100 fields show that our selection algorithm improves the compression ratio up to 70 percent with the same level of data distortion because of very accurate selection (around 99 percent) of the bestfit compressor, with little overhead (less than 7 percent in the experiments).

97 MATHEMATICS AND COMPUTING↗

Mars Reconnaissance Orbiter Uplink Analysis Tool

This software analyzes Mars Reconnaissance Orbiter (MRO) orbital geometry with respect to Mars Exploration Rover (MER) contact windows, and is the first tool of its kind designed specifically to support MRO-MER interface coordination. Prior to this automated tool, this analysis was done manually with Excel and the UNIX command line. In total, the process would take approximately 30 minutes for each analysis. The current automated analysis takes less than 30 seconds. This tool resides on the flight machine and uses a PHP interface that does the entire analysis of the input files and takes into account one-way light time from another input file. Input flies are copied over to the proper directories and are dynamically read into the tool s interface. The user can then choose the corresponding input files based on the time frame desired for analysis. After submission of the Web form, the tool merges the two files into a single, time-ordered listing of events for both spacecraft. The times are converted to the same reference time (Earth Transmit Time) by reading in a light time file and performing the calculations necessary to shift the time formats. The program also has the ability to vary the size of the keep-out window on the main page of the analysis tool by inputting a custom time for padding each MRO event time. The parameters on the form are read in and passed to the second page for analysis. Everything is fully coded in PHP and can be accessed by anyone with access to the machine via Web page. This uplink tool will continue to be used for the duration of the MER mission's needs for X-band uplinks. Future missions also can use the tools to check overflight times as well as potential site observation times. Adaptation of the input files to the proper format, and the window keep-out times, would allow for other analyses. Any operations task that uses the idea of keep-out windows will have a use for this program.

Khanampompan, Teerapat↗

Process prediction and detection of faults using probabilistic bidirectional recurrent neural networks on real plant data

Attaining Industry 4.0 for manufacturing operations requires advanced monitoring systems and real-time data analytics of plant data, among other topics. We propose a Probabilistic Bidirectional Recurrent Network (PBRN) for industrial process monitoring for the early detection of faults. The model is based on a Gated Recurrent Unit (GRU) neural network that allows the model to retain long-term dependencies between sensor data along a time horizon, hence learning the dynamic behavior of the process. To reduce the false-positive detection rate of the model, we compel the model to learn from a highly noisy sensor reading while outputting noise-free sensor outputs. The performance of the proposed model is compared to other data-driven statistical process monitoring schemes using real plant data from an industrial Air Separations Unit (ASU) containing noisy sensor readings. We show that the model can learn from noisy data without reducing its performance. Using two different fault cases, we demonstrate the model’s ability to carry out early fault detection with average false-positive rates of 2.9% and 4.9% for both fault cases. The missed detection rates are 0.1% and 0.2%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hierarchical Data Format for Nuclear Data Sensitivities

The SCALE code system includes capabilities for sensitivity and uncertainty (S/U) analysis as part of its TSUNAMI code suite. The sensitivity of a quantity of interest (for example, an application’s $k_{eff}$) to nuclear data is stored as a profile in a text-based file, which is known as a sensitivity data file (SDF). The sensitivity profile can be used to calculate uncertainties, correlation coefficients, and similarity indices. One of the goals of the present work was to seek general performance improvements in the TSUNAMI code suite, starting with the TSUNAMI-IP code for calculating similarity indices. Through profiling, it was found that reading the text-based sensitivity files was a performance bottleneck in the TSUNAMI-IP code. In a typical TSUNAMI-IP calculation, an application might be compared to thousands of benchmarks, thus requiring the reading of thousands of SDFs. Reading of binary-based data is generally faster than reading text-based data. Hierarchical Data Format 5 (HDF5) is a binary-based format that also benefits from being portable, and it can be inspected with nonproprietary tools. This paper describes an HDF5-based file format that has been introduced for SDFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Fermilab Test Beam Facility Data Acquisition System Based on $otsdaq$

The Real-Time Systems Engineering Department of the Scientific Computing Division at Fermilab has deployed set of customizations to our Off-The-Shelf Data Acquisition solution (otsdaq) at the Fermilab Test Beam Facility (FTBF) to read out the beamline instrumentation in support of FTBF users. In addition to reading out several detectors which use various detection technologies and readout hardware, the FTBF Data Acquisition system (DAQ) can perform basic track reconstruction through the facility in real time and provide data to facility users. An advanced prototype smart coincidence module, known as the NIM+, performs trigger distribution and throttling, allowing the beamline instrumentation to be read out at different rates. Spill data are saved to disk for studies of the facility performance, and hit data are also made available on the FTBF network for experiments' use. A web-based run control and configuration GUI are provided, and the online monitoring snapshots created after each beam spill are viewable from any computer connected to the Fermilab network. The integrated DAQ system for the facility provides users with high-precision tracking data along the beamline and a single location for obtaining data from the facility detectors, which set the baseline for testing their own detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of BISON metallic fuel performance modeling against experimental measurements within FIPD and IMIS databases

Simulations were conducted using the BISON fuel performance code on an automated process to read initial and operating conditions from two databases—the Fuels Irradiation and Physics Database (FIPD) and Integral Fast Reactor Materials Information System (IMIS) database. These databases contain metallic fuel data from the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF). The work demonstrates use of an integrated framework to access EBR-II fuel pin data for evaluating fuel performance models contained within BISON to predict fuel performance of next-generation metallic fuel systems. Between IMIS and FIPD, there is enough information to conduct 1,977 unique EBR-II metallic fuel pin histories from 29 different experiments, and 338 pins from FFTF MFF-3 and MFF-5 with varying levels of details between the two databases. Each of these fuel performance histories includes a high-resolution power history, flux history, coolant channel flow rates, and coolant channel temperatures, and new model developments in BISON since the initial demonstration of this integrated framework. Fission gas release (FGR), cumulative damage fraction, fuel axial swelling, FCCI wastage thickness, cladding profilometry, and burnup were all simulated in BISON and compared to post-irradiation examination (PIE) results to evaluate BISON fuel performance modeling. Implementation of new fuel performance models into a generic BISON input file coupled with IMIS and FIPD yielded results with a better representation of physics than the initial evaluation of the integrated framework. Cladding profilometry, FGR, and fuel axial swelling were found to be in good agreement with PIE measurements for most of the pins simulated. The chosen mechanical contact solver was found to significantly impact the axial fuel swelling and cladding strain predictions when used in conjunction with the U-Pu-Zr hot-pressing model since it bound the fuel to prevent further swelling and increased hydrostatic stresses. This work suggests that fuel performance modeling in BISON under steady-state conditions represents the PIE data well and should be reassessed when new PIE data become available in IMIS and FIPD databases and when improved physical models to better capture fuel performance are added to BISON.

Paaren, Kyle M.↗

Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

Purpose: In this study, the authors present a silicon photomultiplier (SiPM)-based positron emission tomography (PET) insert dedicated to small animal imaging with high system performance and robustness to temperature change. Methods: The insert consists of 64 LYSO-SiPM detector blocks arranged in 4 rings of 16 detector blocks to yield a ring diameter of 64 mm and axial field of view of 55 mm. Each detector block consists of a 9 × 9 array of LYSO crystals (1.2 × 1.2 × 10 mm{sup 3}) and a monolithic 4 × 4 SiPM array. The temperature of each monolithic SiPM is monitored, and the proper bias voltage is applied according to the temperature reading in real time to maintain uniform performance. The performance of this PET insert was characterized using National Electrical Manufacturers Association NU 4-2008 standards, and its feasibility was evaluated through in vivo mouse imaging studies. Results: The PET insert had a peak sensitivity of 3.4% and volumetric spatial resolutions of 1.92 (filtered back projection) and 0.53 (ordered subset expectation maximization) mm{sup 3} at center. The peak noise equivalent count rate and scatter fraction were 42.4 kcps at 15.08 MBq and 16.5%, respectively. By applying the real-time bias voltage adjustment, an energy resolution of 14.2% ± 0.3% was maintained and the count rate varied ≤1.2%, despite severe temperature changes (10–30 °C). The mouse imaging studies demonstrate that this PET insert can produce high-quality images useful for imaging studies on the small animals. Conclusions: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a Stiffness-Based Chemistry Load Balancing Scheme, and Optimization of Input/Output and Communication, to Enable Massively Parallel High-Fidelity Internal Combustion Engine Simulations

A closed-cycle gasoline compression ignition engine simulation near top dead center (TDC) was used to profile the performance of a parallel commercial engine computational fluid dynamics code, as it was scaled on up to 4096 cores of an IBM Blue Gene/Q supercomputer. The test case has 9 million cells near TDC, with a fixed mesh size of 0.15 mm, and was run on configurations ranging from 128 to 4096 cores. Profiling was done for a small duration of 0.11 crank angle degrees near TDC during ignition. Optimization of input/output performance resulted in a significant speedup in reading restart files, and in an over 100-times speedup in writing restart files and files for post-processing. Improvements to communication resulted in a 1400-times speedup in the mesh load balancing operation during initialization, on 4096 cores. An improved, “stiffness-based” algorithm for load balancing chemical kinetics calculations was developed, which results in an over 3-times faster run-time near ignition on 4096 cores relative to the original load balancing scheme. With this improvement to load balancing, the code achieves over 78% scaling efficiency on 2048 cores, and over 65% scaling efficiency on 4096 cores, relative to 256 cores.

CFD, Mira, Supercomputing, High Performance Comput↗

Deep Gaze Velocity Analysis During Mammographic Reading for Biometric Identification of Radiologists

Several studies have confirmed that the gaze velocity of the human eye can be utilized as a behavioral biometric or personalized biomarker. In this study, we leverage the local feature representation capacity of convolutional neural networks (CNNs) for eye gaze velocity analysis as the basis for biometric identification of radiologists performing breast cancer screening. Using gaze data collected from 10 radiologists reading 100 mammograms of various diagnoses, we compared the performance of a CNN-based classification algorithm with two deep learning classifiers, deep neural network and deep belief network, and a previously presented hidden Markov model classifier. The study showed that the CNN classifier is superior compared to alternative classification methods based on macro F1-scores derived from 10-fold cross-validation experiments. Our results further support the efficacy of eye gaze velocity as a biometric identifier of medical imaging experts.

59 BASIC BIOLOGICAL SCIENCES↗

Algorithm for Identifying Erroneous Rain-Gauge Readings

An algorithm analyzes rain-gauge data to identify statistical outliers that could be deemed to be erroneous readings. Heretofore, analyses of this type have been performed in burdensome manual procedures that have involved subjective judgements. Sometimes, the analyses have included computational assistance for detecting values falling outside of arbitrary limits. The analyses have been performed without statistically valid knowledge of the spatial and temporal variations of precipitation within rain events. In contrast, the present algorithm makes it possible to automate such an analysis, makes the analysis objective, takes account of the spatial distribution of rain gauges in conjunction with the statistical nature of spatial variations in rainfall readings, and minimizes the use of arbitrary criteria. The algorithm implements an iterative process that involves nonparametric statistics.

Rickman, Doug↗

Evolution of the ROOT Tree I/O

The ROOT TTree data format encodes hundreds of petabytes of High Energy and Nuclear Physics events. Its columnar layout drives rapid analyses, as only those parts (“branches”) that are really used in a given analysis need to be read from storage. Its unique feature is the seamless C++ integration, which allows users to directly store their event classes without explicitly defining data schemas. In this contribution, we present the status and plans of the future ROOT 7 event I/O. Along with the ROOT 7 interface modernization, we aim for robust, where possible compile-time safe C++ interfaces to read and write event data. On the performance side, we show first benchmarks using ROOT’s new experimental I/O subsystem that combines the best of TTrees with recent advances in columnar data formats. A core ingredient is a strong separation of the high-level logical data layout (C++ classes) from the low-level physical data layout (storage backed nested vectors of simple types). We show how the new, optimized physical data layout speeds up serialization and deserialization and facilitates parallel, vectorized and bulk operations. This lets ROOT I/O run optimally on the upcoming ultra-fast NVRAM storage devices, as well as file-less storage systems such as object stores.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-120: Dosimetric Characteristics Study of NanoDotâ,,¢ for In-Vivo Dosimetry

Purpose: The purpose of the study was to analyze the dosimetric characteristics (energy dependence, reproducibility and dose linearity) of nanoDot™ optically stimulated luminescence dosimeters (OSLDs) and validate their potential use during in-vivo dosimetry, specifically TBI. The manufacturer stated accuracy is ±10% for standard nanoDot™. Methods: At AKUH, the InLight microStar OSL dosimetry system for patient in-vivo dosimetry is in use since 2012. Twenty-five standard nanoDot™ were used in the analysis. Sensitivity and reproducibility was tested in the first part with 6MV and 18 MV Varian x-ray beams. Each OSLD was irradiated to 100cGy dose at nominal SSD (100 cm). All the OSLDs were read 3 times for average reading. Dose linearity and calibration were also performed with same beams in common clinical dose range of 0 - 500 cGy. In addition, verification of TBI absolute dose at extended SSD (500cm) was also performed. Results: The reproducibility observed with the OSLD was better than the manufacturer stated limits. Measured doses vary less than ±2% in 19(76%) OSLDs, whereas less than ±3% in 6(24%) OSLDs. Their sensitivity was approximately 525 counts per cGy. Better agreement was observed between measurements, with a standard deviation of 1.8%. A linear dose response was observed with OSLDs for both 6 and 18MV beams in 0 - 500 cGy dose range. TBI measured doses at 500 cm SSD were also confirmed to be within ±0.5% and ±1.3% of the ion chamber measured doses for 6 and 18MV beams respectively. Conclusion: The dosimetric results demonstrate that nanoDot™ can be potentially used for in-vivo dosimetry verification in various clinical situations, with a high degree of accuracy and precision. In addition OSLDs exhibit better dose reproducibility with standard deviation of 1.8%. There was no significant difference in their response to 6 and 18MV beams. The dose response was also linear.

60 APPLIED LIFE SCIENCES↗

Strong and Efficient Consistency with Consistency-aware Durability

We introduce consistency-aware durability or C ad , a new approach to durability in distributed storage that enables strong consistency while delivering high performance. We demonstrate the efficacy of this approach by designing cross-client monotonic reads , a novel and strong consistency property that provides monotonic reads across failures and sessions in leader-based systems; such a property can be particularly beneficial in geo-distributed and edge-computing scenarios. We build O rca , a modified version of ZooKeeper that implements C ad and cross-client monotonic reads. We experimentally show that O rca provides strong consistency while closely matching the performance of weakly consistent ZooKeeper. Compared to strongly consistent ZooKeeper, O rca provides significantly higher throughput (1.8--3.3×) and notably reduces latency, sometimes by an order of magnitude in geo-distributed settings. We also implement C ad in Redis and show that the performance benefits are similar to that of C ad ’s implementation in ZooKeeper.

Computer Science↗

Xavier: High-Performance X-Drop Adaptive Banded Pairwise Alignment (Xavier) v1.0

Pairwise sequence alignment is one of the most compute-intense challenges for the analysis of genomics data and it can account for more than 90% of the runtime depending on the application. Despite the effort to reduce the computational cost introducing heuristics such as banded and x-drop alignment, the performance of state-of-the-art software is often unsatisfactory for long sequences. Recent advances in single-molecule sequencing technologies keep increasing the length of the sequences to align at the cost of higher error rates b ranging from 5% to 15% b, emphasizing the need for fast and accurate software. Our long-read alignment software, named Xavier, computes high-performance x-drop adaptive banded pairwise alignment exploiting instruction-level parallelism via Single-Instruction-Multiple-Data (SIMD) operations. Xavier uses a narrow bandwidth that appreciably improves performance reducing the search space for the optimal alignment. In our experiment, the adaptive mechanism enables Xavier to find the optimal alignment between related sequences even when the error rate is as high as 50%. Xavier achieves speed-up up to 5X over competitor software when enabling the x-drop termination and up to 415X when disabling it, with negligible accuracy loss.

Guidi, Giulia↗

T1044: sPHENIX Calorimetry Tests

The sPHENIX upgrade to the PHENIX detector is designed to study jets in heavy ion collisions at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory and address questions about the nature of the perfect fluid quark-gluon plasma. The upgrade consists of a 2 Tesla superconducting magnetic solenoid of radius 70 cm surrounded by electromagnetic and hadronic calorimeters with uniform coverage over a rapidity range of IT'ii < 1 and 2n in azimuth. The sPHENIX detector concept takes advantage of technological developments to enable a compact design with excellent performance. A tungsten-scintillator electromagnetic calorimeter read out with silicon photomultipliers (SiPMs) allows for a physically thin device, which can operate in a magnetic field, without the bulk of photomultiplier tubes and the need for high voltage distribution. The smaller electromagnetic calorimeter also allows the hadron calorimeter to be less massive, and the use of silicon photomultipliers for the hadron calorimeter allow for nearly identical electronic readout for the two major systems. The requirements for the sPHENIX electromagnetic calorimeter lead to a design that is compact (i.e. has a small Molie 're radius and short radiation length), has a high degree of segmentation (0.024 x 0.024 in TJ and

Mannel, Eric↗