Search NASA⌕ Search

SEARCH · Search NASA

Results for “regression test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Bayesian probability of agreement for comparing the similarity of response surfaces

For a variety of linear and generalized linear models, there may be interest in evaluating whether the expected response values in two different populations are sufficiently similar to be considered practically equivalent. The probability of agreement has been introduced as a strategy for quantifying the similarity between two groups. We propose a Bayesian version of the probability of agreement to quantify the similarity between linear and generalized linear response surfaces. The proposed methodology is based on Markov chain Monte Carlo estimation and it allows for an intuitive interpretation based directly on population parameters. As demonstrated, the methodology can be flexibly applied to a variety of different models. We illustrate its use with three examples for which the response depends on predictor variables through a linear, logistic, or Poisson regression model. The computation associated with this approach has been automated with a freely available R Shiny app.

97 MATHEMATICS AND COMPUTING↗

Characterization, Operation and Analysis of Test Motors Containing Aluminized Hybrid Fuels

NASA Marshall Space Flight Center's Materials and Processes Department, with support from the Propulsion Systems Department, has renewed the development and maintenance of a hybrid test bed for exposing ablative thermal protection materials to an environment similar to that seen in solid rocket motors (SRM). The Solid Fuel Torch (SFT), operated during the Space Shuttle program, utilized gaseous oxygen for oxidizer and an aluminized hydroxyl-terminated polybutadiene (HTPB) fuel grain to expose a converging section of phenolic material to a 400 psi, 2-phase flow combustion environment. The configuration allows for up to a 2 foot long, 5 inch diameter fuel grain cartridge. Wanting to now test rubber insulation materials with a turn-back feature to mimic the geometry of an aft dome being impinged by alumina particles, the throat area has now been increased by several times to afford flow similarity. Combined with the desire to maintain a higher operating pressure, the oxidizer flow rate is being increased by a factor of 10. Out of these changes has arisen the need to characterize the fuel/oxidizer combination in a higher mass flux condition than has been previously tested at MSFC, and at which the literature has little to no reporting as well. Testing for fuel regression rate comprised a two-level, full factorial design available over Aluminum loading level, mass flow rate, pressure, and diameter. The data taken significantly surpasses the previous available data on regression rate of aluminized HTPB fuel burning with gaseous oxygen. It encompasses higher mass fluxes, and appears to generate more consistent data. The good test article and facility design and testing work of the Penn State HPCL combined with careful analysis of the data and good planning has made this possible. This should be able to assist with developing rate laws that are useful both for research planning and for developing flight system sizing relationships that can help optimize hybrid rocket concepts for trade studies. The successful approach of this DOE and test setup is applicable to other propellant combinations as well.

Kibbey, Timothy P.↗

Characterization, Operation and Analysis of Test Motors Containing Aluminized Hybrid Fuels

NASA Marshall Space Flight Center's Materials and Processes Department, with support from the Propulsion Systems Department, has renewed the development and maintenance of a hybrid test bed for exposing ablative thermal protection materials to an environment similar to that seen in solid rocket motors (SRM). The Solid Fuel Torch (SFT), operated during the Space Shuttle program, utilized gaseous oxygen for oxidizer and an aluminized hydroxyl-terminated polybutadiene (HTPB) fuel grain to expose a converging section of phenolic material to a 400 psi, 2-phase flow combustion environment. The configuration allows for up to a 2 foot long, 5 inch diameter fuel grain cartridge. Wanting to now test rubber insulation materials with a turn-back feature to mimic the geometry of an aft dome being impinged by alumina particles, the throat area has now been increased by several times to afford flow similarity. Combined with the desire to maintain a higher operating pressure, the oxidizer flow rate is being increased by a factor of 10. Out of these changes has arisen the need to characterize the fuel/oxidizer combination in a higher mass flux condition than has been previously tested at MSFC, and at which the literature has little to no reporting as well. Testing for fuel regression rate comprised a two-level, full factorial design available over Aluminum loading level, mass flow rate, pressure, and diameter. The data taken significantly surpasses the previous available data on regression rate of aluminized HTPB fuel burning with gaseous oxygen. It encompasses higher mass fluxes, and appears to generate more consistent data. The good test article and facility design and testing work of the Penn State HPCL combined with careful analysis of the data and good planning has made this possible. This should be able to assist with developing rate laws that are useful both for research planning and for developing flight system sizing relationships that can help optimize hybrid rocket concepts for trade studies. The successful approach of this DOE and test setup is applicable to other propellant combinations as well.

Kibbey, Timothy P.↗

Learning epistatic polygenic phenotypes with Boolean interactions

Detecting epistatic drivers of human phenotypes is a considerable challenge. Traditional approaches use regression to sequentially test multiplicative interaction terms involving pairs of genetic variants. For higher-order interactions and genome-wide large-scale data, this strategy is computationally intractable. Moreover, multiplicative terms used in regression modeling may not capture the form of biological interactions. Building on the Predictability, Computability, Stability (PCS) framework, we introduce the epiTree pipeline to extract higher-order interactions from genomic data using tree-based models. The epiTree pipeline first selects a set of variants derived from tissue-specific estimates of gene expression. Next, it uses iterative random forests (iRF) to search training data for candidate Boolean interactions (pairwise and higher-order). We derive significance tests for interactions, based on a stabilized likelihood ratio test, by simulating Boolean tree-structured null (no epistasis) and alternative (epistasis) distributions on hold-out test data. Finally, our pipeline computes PCS epistasis p-values that probabilisticly quantify improvement in prediction accuracy via bootstrap sampling on the test set. We validate the epiTree pipeline in two case studies using data from the UK Biobank: predicting red hair and multiple sclerosis (MS). In the case of predicting red hair, epiTree recovers known epistatic interactions surrounding MC1R and novel interactions, representing non-linearities not captured by logistic regression models. In the case of predicting MS, a more complex phenotype than red hair, epiTree rankings prioritize novel interactions surrounding HLA-DRB1 , a variant previously associated with MS in several populations. Taken together, these results highlight the potential for epiTree rankings to help reduce the design space for follow up experiments.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-497: Semi-Automated in Vivo Radiochromic Film Dosimetry Using a Novel Image Processing Algorithm

Purpose: To validate an automated image processing algorithm designed to detect the center of radiochromic film used for in vivo film dosimetry against the current gold standard of manual selection. Methods: An image processing algorithm was developed to automatically select the region of interest (ROI) in *.tiff images that contain multiple pieces of radiochromic film (0.5x1.3cm{sup 2}). After a user has linked a calibration file to the processing algorithm and selected a *.tiff file for processing, an ROI is automatically detected for all films by a combination of thresholding and erosion, which removes edges and any additional markings for orientation. Calibration is applied to the mean pixel values from the ROIs and a *.tiff image is output displaying the original image with an overlay of the ROIs and the measured doses. Validation of the algorithm was determined by comparing in vivo dose determined using the current gold standard (manually drawn ROIs) versus automated ROIs for n=420 scanned films. Bland-Altman analysis, paired t-test, and linear regression were performed to demonstrate agreement between the processes. Results: The measured doses ranged from 0.2-886.6cGy. Bland-Altman analysis of the two techniques (automatic minus manual) revealed a bias of -0.28cGy and a 95% confidence interval of (5.5cGy,-6.1cGy). These values demonstrate excellent agreement between the two techniques. Paired t-test results showed no statistical differences between the two techniques, p=0.98. Linear regression with a forced zero intercept demonstrated that Automatic=0.997*Manual, with a Pearson correlation coefficient of 0.999. The minimal differences between the two techniques may be explained by the fact that the hand drawn ROIs were not identical to the automatically selected ones. The average processing time was 6.7seconds in Matlab on an IntelCore2Duo processor. Conclusion: An automated image processing algorithm has been developed and validated, which will help minimize user interaction and processing time of radiochromic film used for in vivo dosimetry.

60 APPLIED LIFE SCIENCES↗

Sierra/SolidMechanics 4.46 Example Problems Manual

Presented in this document are tests that exist in the Sierra Solid Mechanics example problem suite. The purpose of these examples is to showcase common and advanced code capabilities. Note that many other regression and verification tests exist in the Sierra/SM test suite that have not been included in this manual.

97 MATHEMATICS AND COMPUTING↗

Core Body Temperature Predictions Using Metabolic Energy Expenditure and Heart Rate During Simulated Extravehicular Activity

Long duration spaceflight missions will require crew to become more autonomous in conducting extravehicular activities (EVA) without direct communication with Mission Control for biomedical support. To enable such autonomy, we are developing a Crew State and Risk Model (CSRM) as a collection of key physiology domains that drive EVA crew capabilities and workloads. One model component of CSRM is human thermal regulation. In this paper, customized development of a baseline model to predict core body temperature is presented using physiology inputs of heart rate and metabolic rate. The model development dataset included a baseline study where participants (n=6, equal male and female) performed a 5-hour EVA in a two-part session while wearing a hybrid space suit simulator (HS3). The first session included an end-to-end EVA traversing 1500 meters to a geology site and traversing back to a habitat conducting geology, payload relocation, and maintenance operations every 500 meters. The second session included standalone tasks of a 2000-meter traverse followed by geology tasks. Thermal measures of core body temperature, local skin temperature, liquid cooling garment temperature, heart rate, and metabolic rate were collected through the test duration. Multiple regression was used to build a linear equation to predict core body temperature from inputs of heart rate and metabolic rate. Heat storage was calculated via predicted core body temperature plus LCG and skin temperatures. The model was tested against a dataset from a pressurized suited test (n=6, equal male and female) in the NASA Active Response Gravity Offload System (ARGOS) conducting similar end-to-end EVA and standalone tasks. Predicted error of the model against the raw test cases was 0.2±0.15 °C. The baseline prediction of core body temperature using heart rates and metabolic rates allows for simple real-time tracking from data collected in-flight to monitor crew consumables and thermal flight limits during EVA.

Bradley Hoffmann↗

Strain Gauge Balance Uncertainty Analysis at NASA Langley: A Technical Review

This paper describes a method to determine the uncertainties of measured forces and moments from multi-component force balances used in wind tunnel tests. A multivariate regression technique is first employed to estimate the uncertainties of the six balance sensitivities and 156 interaction coefficients derived from established balance calibration procedures. These uncertainties are then employed to calculate the uncertainties of force-moment values computed from observed balance output readings obtained during tests. Confidence and prediction intervals are obtained for each computed force and moment as functions of the actual measurands. Techniques are discussed for separate estimation of balance bias and precision uncertainties.

John S Tripp↗

High-pressure ignition delay time measurements of a four-component gasoline surrogate and its high-level blends with ethanol and methyl acetate

Ignition delay times of a gasoline surrogate (iso-octane/toluene/n-heptane/1-hexene at 55/25/15/5% by liquid volume, developed in McCormick et al. 2017) with high-level bioblendstock-gasoline surrogate blends (50% and 85% biofuel by liquid volume of each ethanol and methyl acetate) were collected behind reflected shock waves. Post-reflected-shock temperatures ranged from 968 to 1361 K at pressures of about 4, 10, 25, and 50 atm. Data were collected for real fuel–air mixtures at fuel lean and stoichiometric conditions (φ = 0.5, 1.0) with focus on the more-practical, fuel-lean conditions. Ignition delay times were measured from OH* chemiluminescence around 307 nm using an endwall diagnostic. The RON and MON of the surrogate were 90.3 and 84.7, respectively. Ethanol was chosen due to its wide use in flex-fuel vehicles and availability, while also providing an increased octane rating. Methyl acetate was chosen for its especially high octane rating to investigate the effect of an extreme case. To validate the gasoline surrogate, the data are compared to real gasoline (RD387) and several gasoline surrogate experiments from the literature. Using the wide range of pressures studied, the gasoline surrogate’s pressure dependence was quantified to account for test-to-test variations using regression analysis. Similarly, a global correlation for gasoline and its surrogates was developed using all available data from the literature. Two modern chemical kinetics models targeting gasoline and its surrogates are compared to the ignition delay time measurements. These new high-pressure, high-bioblendstock concentration tests provide required chemical kinetic data for optimizing fuel and engine design.

42 ENGINEERING↗

Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher's exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade {>=}3 acute or late toxicity was 6.8% (14 patients). Fisher's exact test resulted in significant median splits for grade {>=}3 toxicity at V12 = 3.78 cm{sup 3} (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm{sup 3} (RR 13, P=.0013), V20 = 0.11 cm{sup 3} (RR 6, P=0.01), and V22 = 0.0 cm{sup 3} (RR 13, P=.0013). The median split for D2.5 cm{sup 3} (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm{sup 3}. One hundred percent (n = 7) of grade {>=}4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade {>=}3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are associated with development of grade {>=}4 toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting tropical cyclone intensity using satellite measured equivalent blackbody temperatures of cloud tops

A regression technique was developed to forecast 24 hour changes of the maximum winds for weak (maximum winds less than or equal to 65 Kt) and strong (maximum winds greater than 65 Kt) tropical cyclones by utilizing satellite measured equivalent blackbody temperatures around the storm alone and together with the changes in maximum winds during the preceding 24 hours and the current maximum winds. Independent testing of these regression equations shows that the mean errors made by the equations are lower than the errors in forecasts made by the peristence techniques.

Gentry, R. C.↗

Unilateral Prostate Cancer Cannot be Accurately Predicted in Low-Risk Patients

Purpose: Hemiablative therapy (HAT) is increasing in popularity for treatment of patients with low-risk prostate cancer (PCa). The validity of this therapeutic modality, which exclusively treats PCa within a single prostate lobe, rests on accurate staging. We tested the accuracy of unilaterally unremarkable biopsy findings in cases of low-risk PCa patients who are potential candidates for HAT. Methods and Materials: The study population consisted of 243 men with clinical stage {<=}T2a, a prostate-specific antigen (PSA) concentration of <10 ng/ml, a biopsy-proven Gleason sum of {<=}6, and a maximum of 2 ipsilateral positive biopsy results out of 10 or more cores. All men underwent a radical prostatectomy, and pathology stage was used as the gold standard. Univariable and multivariable logistic regression models were tested for significant predictors of unilateral, organ-confined PCa. These predictors consisted of PSA, %fPSA (defined as the quotient of free [uncomplexed] PSA divided by the total PSA), clinical stage (T2a vs. T1c), gland volume, and number of positive biopsy cores (2 vs. 1). Results: Despite unilateral stage at biopsy, bilateral or even non-organ-confined PCa was reported in 64% of all patients. In multivariable analyses, no variable could clearly and independently predict the presence of unilateral PCa. This was reflected in an overall accuracy of 58% (95% confidence interval, 50.6-65.8%). Conclusions: Two-thirds of patients with unilateral low-risk PCa, confirmed by clinical stage and biopsy findings, have bilateral or non-organ-confined PCa at radical prostatectomy. This alarming finding questions the safety and validity of HAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical model to perform error analysis of curve fits of wind tunnel test data using the techniques of analysis of variance and regression analysis

The considered research had the objective to design a statistical model that could perform an error analysis of curve fits of wind tunnel test data using analysis of variance and regression analysis techniques. Four related subproblems were defined, and by solving each of these a solution to the general research problem was obtained. The capabilities of the evolved true statistical model are considered. The least squares fit is used to determine the nature of the force, moment, and pressure data. The order of the curve fit is increased in order to delete the quadratic effect in the residuals. The analysis of variance is used to determine the magnitude and effect of the error factor associated with the experimental data.

Alston, D. W.↗

A neural network for beam background decomposition in Belle II at SuperKEKB

Here, we describe a neural network for predicting the background hit rate in the Belle II detector produced by the SuperKEKB electron-positron collider. The neural network, BGNet, learns to predict the individual contributions of different physical background sources, such as beam-gas scattering or continuous top-up injections into the collider, to Belle II sub-detector rates. The samples for learning are archived 1 Hz time series of diagnostic variables from the SuperKEKB collider subsystems and measured hit rates of Belle II used as regression targets. We test the learned model by predicting detector hit rates on archived data from different run periods not used during training. We show that a feature attribution method can help interpret the source of changes in the background level over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of a statistical approach to rainfall estimation using Nimbus 5 6.7 micrometers and 11.5 micrometers THIR data

Nimbus 5 6.7 mm and 11.5 mm temperature humidity infrared radiometer (THIR) data were used in a simple multiple regression scheme to test the feasibility of using these data to estimate hourly rainfall. Throughout the test area (85 W to 105 W and 45 N to 30 N) subareas (8 deg x 6 deg) were chosen from which point to point and areal statistics were obtained. Four subsets of data were used. The first consisted of only those surface stations indicating precipitation whose latitude and longitude coincided with the THIR grid points. A second used surface stations 0.1 degree from the THIR grid points. The third was a combination of subsets one and two. A reciprocal distance weighting scheme was used to derive precipitation values in data sparse areas. A fourth subset was made using these data combined with the data from subsets one and two. Point estimates resulted in negative correlations between estimated and grid derived "surface" precipitation. One degree areal estimates showed a slight improvement with a correlation coefficient of approximately 0.11. Single regression areal estimates resulted in correlations of approximately 0.11 and 0.20 for the 6.7 mm and 11.5 mm data respectively. These poor results were attributed to problems which are inherent in the satellite data (location errors, short temporal span of data, wavelength of sensors, etc.) and the lack of sufficient surface data to better verify the satellite estimate.

Ormsby, J. P.↗

Development of Data-Driven Models for Performance Prediction and Chemical Dosing of a Full-Scale Controlled Phosphorus Precipitation Reactor

This study evaluated the use of data-driven models to improve control of a struvite precipitation reactor that removes phosphorus from wastewater while producing a fertilizer product. The researchers developed predictive models for influent orthophosphate concentration, effluent orthophosphate concentration, and phosphorus removal using operational data from a full-scale MagPrex™ reactor at a water resource recovery facility in Denver, Colorado. Model predictions were used to recommend magnesium chloride dosing adjustments needed to achieve a target effluent phosphorus concentration. Several machine learning approaches were tested, with ridge regression providing the best predictions for influent orthophosphate concentration and phosphorus removal, and XGBoost providing the best predictions for effluent orthophosphate concentration. Simulation results indicated that the decision-support approach could correctly identify dosing adjustments in most cases and reduce chemical use. Full-scale implementation achieved lower accuracy due to changing operating conditions and limited historical data in some operating ranges. Here, the results demonstrate the potential of data-driven tools to support phosphorus recovery process control while also identifying practical limitations that affect deployment in full-scale systems.

42 ENGINEERING↗

Tissue sampling in the era of precision medicine: comparison of percutaneous biopsies performed for clinical trials or tumor genomics versus routine clinical care

Purpose: The purpose of the study was to determine if patients undergoing percutaneous biopsy for genetic profiling are undergoing more biopsies (procedures, passes per procedure), or experiencing more procedure-related complications. Methods: 60 patients undergoing biopsy procedures for genetic profiling were retrospectively compared with 60 consecutive control patients undergoing routine biopsies. Procedural details and related complications were collected. Results were analyzed using t-tests and logistic regression. Results: Biopsied organs included mainly lung (n = 31), liver (n = 50), and lymph nodes (n = 18). The average number of core biopsy passes was 3.45 in the study group and 2.18 in the control group (0.73, 1.81; p = 0.0001). The average study patient underwent 1.44 biopsy procedures by radiology from 2016 to 2017, whereas the average control patient underwent 1.08 (0.1657, 0.5010, p = 0.0002). Results were similar when looking at the subset of patients undergoing liver biopsies. In our cohort of 120 patients total, only 6 complications were noted. There were 4 complications in the control patients and 2 complications in the study patients, all of which were pneumothoraces in patients undergoing lung biopsy; only 2 of these required treatment. The odds ratio for a complication occurring from an increase in one core biopsy is 1.07 (0.601, 1.573; p = 0.775), suggesting no significant relationship among the number of biopsies taken and the probability of complication in this cohort. Conclusions: Patients being biopsied for genetic profiling or clinical study enrollment are undergoing more biopsy procedures and more biopsy passes per procedure, but are not experiencing a detectable increased rate of complications in this small cohort, single-center study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗