Search NASA⌕ Search

SEARCH · Search NASA

Results for “scintillator characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Spectral Hardness of X- and Gamma-Ray Emissions From Lightning Stepped and Dart Leaders

During the 2022 New Mexico monsoon season, we deployed two X-ray scintillation detectors, coupled with a 180 MHz data acquisition system to detect X-rays from natural lightning at the Langmuir Lab mountain-top facility, located at 3.3 km above mean sea level. Data acquisition was triggered by an electric field antenna calibrated to pick up lightning within a few km of the X-ray detectors. We report the energies of over 240 individual photons, ranging between 13 keV and 3.8 MeV, as registered by the LaBr3(Ce) scintillation detector. These detections were associated with four lightning flashes. Particularly, four-stepped leaders and seven dart leaders produced energetic radiation. Importantly, the reported photon energies allowed us to confirm that the X-ray energy distribution of natural stepped and dart leaders follows a power-law distribution with an exponent ranging between 1.09 and 1.96, with stepped leaders having a harder spectrum. Characterization of the associated leaders and return strokes was done with four different electric field sensing antennas, which can measure a wide range of time scales, from the static storm field to the fast change associated with dart leaders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of proton bunch parameters in the AWAKE experiment

A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. Finally, the analysis is tested on simulated data and then applied to the experimental data.

47 OTHER INSTRUMENTATION↗

Comparison of AGR-3/4 Fission Product Transport Model to Measurements and Extraction of Diffusivities via Analytical Fits

A one-dimensional finite-element model based on the MOOSE framework has been constructed, and overall transport estimates are predicted based on available diffusivities and sorption isotherms in the extant literature. The predicted transport profiles are compared to experimental results, where such results are available, including total inventory analysis of gamma emitters, liquid scintillation results for Sr-90 concentrations, radial deconsolidation leach-burn-leach within compacts, tomographic reconstructions based on detailed gamma scanning and destructive physical sampling of several rings. The magnitude of expected transport to the sink ring is generally predicted by the model for silver and cesium, however, modeled detailed concentration profiles are not consistent with experimental results. Strontium and europium transport is not well characterized by model results.

07 ISOTOPE AND RADIATION SOURCES↗

Industrial deposition of wavelength-shifting films for liquid argon photon detection systems

The Deep Underground Neutrino Experiment (DUNE) Phase-II Far Detector is considering an approximately 2000 m 2 photon detection system to achieve a target mean light yield of 180 PE/MeV. Meeting this requirement demands scalable, cost-effective, and high-quality wavelength-shifter (WLS) coatings capable of converting 127 nm liquid-argon scintillation light into visible photons with controlled and reproducible optical performance. We report on the successful realization of an industrial physical vapor deposition (PVD) process forp-terphenyl (pTP) coatings, adapted from vacuum deposition techniques developed for OLED display manufacturing, to produce uniform WLS layers on large-area inorganic substrates, a task traditionally challenged by adhesion and uniformity issues at organic-inorganic interfaces. Surface characterization by profilometry and spectroscopic measurements demonstrates edge-region thickness variation below 10% and emission spectra consistent with high-quality pTP reference samples. The industrial process demonstrates reproducibility, scalability, and significantly reduced production time compared to laboratory-based methods, while maintaining optical characteristics consistent with established pTP reference samples. These results establish a viable pathway for mass production of high-performance pTP coatings for DUNE FD3 and future neutrino experiments, from a coating manufacturing and process standpoint. Detector-level performance validation, including quantitative VUV conversion efficiency measurements at 127 nm, is identified as future work.

47 OTHER INSTRUMENTATION↗

Devising novel methods for the controlled synthesis with morphology and size control of scintillator materials

Nanoscale scintillators represent an important class of materials underlying the functioning of high resolution, high ‘light yield’ radiation detection equipment, applicable for medicine in addition to security and environmental monitoring. This current study has focused on the controlled synthesis of Cs 2 ZnX 4 (X = Cl, Br) not only due to its very fast and promising radioluminescence decay time but also because no reliable synthesis protocols have been reported for producing nanoscale motifs of this material, to date. Solution-based methods can be used to synthesize products, possessing different, discrete morphologies with the ability to dictate particle size and shape. Specifically, we have demonstrated that a hot injection technique can be used to fabricate nanoscale rods and plates. Using this method, we systematically studied the effect of varying reaction variables, such as (i) reaction temperature, (ii) surfactants, and (iii) reaction time. As synthesized nanorods of Cs 2 ZnCl 4 possessed lengths of 101.3 ± 24.4 nm with widths of 17.3 ± 4.5 nm, whereas Cs 2 ZnBr 4 , created under identical conditions, were characterized by lengths of 206 ± 50 nm and widths of 26.7 ± 12.6 nm. Ligand-assisted re-precipitation (LARP) was used to produce the corresponding micron-sized particles. Under these conditions, we successfully synthesized spindles and spherical particles of Cs 2 ZnCl 4 with sizes of 1.58 ± 0.16 μm and 1.03 ± 0.34 μm, respectively, whereas plates of Cs 2 ZnBr 4 were prepared with average sizes of 0.76 ± 0.21 μm. High resolution synchrotron mapping, using the hard X-ray nanoprobe at NSLS II, was used to confirm the expected spatial distribution of Cs, Zn, and Cl within the as-produced crystals. Nanorods of Cs 2 ZnCl 4 and Cs 2 ZnBr 4 were subsequently tested for scintillation light yield and decay times. Preliminary results showed that Cs 2 ZnCl 4 maintained a light yield of 100–300 photons per MeV with a fast decay component of 2.6 ns. Finally, the Cs 2 ZnBr 4 analogue did not give rise to any perceptible scintillation emission.

36 MATERIALS SCIENCE↗

Structural and Optical Properties of High Entropy (La,Lu,Y,Gd,Ce)AlO 3 Perovskite Thin Films

Mixtures of Ce-doped rare-earth aluminum perovskites are drawing a significant amount of attention as potential scintillating devices. However, the synthesis of complex perovskite systems leads to many challenges. Designing the A-site cations with an equiatomic ratio allows for the stabilization of a single-crystal phase driven by an entropic regime. This work describes the synthesis of a highly epitaxial thin film of configurationally disordered rare-earth aluminum perovskite oxide (La 0.2 Lu 0.2 Y 0.2 Gd 0.2 Ce 0.2 )AlO 3 and characterizes the structural and optical properties. The thin films exhibit three equivalent epitaxial domains having an orthorhombic structure resulting from monoclinic distortion of the perovskite cubic cell. An excitation of 286.5 nm from Gd 3+ and energy transfer to Ce 3+ with 405 nm emission are observed, which represents the potential for high-energy conversion. These experimental results also offer the pathway to tunable optical properties of high-entropy rare-earth epitaxial perovskite films for a range of applications.

36 MATERIALS SCIENCE↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double β decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li 2 100 MoO 4 crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of α particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 ± 0.2) keV FWHM at the Q-value of 100 Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors’ mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an α particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research in Neutrino Physics (Final Technical Report)

The goal of the experimental neutrino efforts at Louisiana State University is to measure the properties of neutrinos and to improve our understanding of neutrino interactions. In pursuit of this goal, the group will continue its Intensity Frontier work on the DUNE experiment at Fermilab and the T2K experiment at J-PARC, Japan. The current work is focused on understanding how neutrinos change flavor and on the possibility for asymmetry between neutrinos and anti-neutrinos. The effort on T2K includes physics measurements using the collected T2K data and preparation for the second phase T2K-II data with an increased beam power and the newly upgraded ND280 detector, featuring a novel 3D fine grained scintillation tracker with 4π acceptance and 3D readout. T2K is in a position to improve our understanding of neutrino nucleus interactions which continue to be one of the largest systematic uncertainties for neutrino oscillation measurements. On DUNE, the effort is on analyzing the data collected by the ProtoDUNE-SP prototype at CERN and on the design, installation, and commissioning of ProtoDUNE-II and later the DUNE Far Detector cold electronics. The final DUNE Module-1 components will be fully characterized by ProtoDUNE-II and the collected data will be used to improve and tune simulation and reconstruction algorithms, and to measure hadron scattering cross section, used to improve the modeling of neutrino final state interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study and improvement of the trigger system in ICARUS

In recent years, intriguing experimental neutrino anomalies have emerged. If confirmed, they could hint at the presence of additional sterile neutrino states playing in neutrino mixing. The Short-Baseline Neutrino project at Fermilab aims to delve into these anomalies, utilizing three Liquid Argon Time Projection Chamber detectors along the Booster Neutrino Beam. The SBND detector serves as nearby instruments, while MicroBooNE and ICARUS function as far detectors and also explore the NuMI beam off-axis. A relevant aspect in the functioning of all SBN detectors is the trigger system, that determines which interactions are recorded. In particular, in ICARUS, it relies on the synchronization of prompt signals from scintillation light within the LAr-TPC, detected by a system of Photo-Multiplier Tubes, with the proton beam’s spill extraction. The existing majority-based logic of the trigger system could potentially be enhanced through adder boards that sum analog signals from PMTs in groups of 15. This sum-based triggering might aid in identifying events near TPC walls, where light is abundant but captured by only a few PMTs, potentially bypassing the majority condition. Comprehensive tests have been performed to characterize these adder boards.

43 PARTICLE ACCELERATORS↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VUV light collection enhancement with metasurface lenses

Vacuum-ultraviolet (VUV) light has applications in many areas of fundamental research and technology, including high-energy physics (HEP) experiments and especially those based on scintillation of noble elements (xenon and argon).There are persistent challenges associated with the detection of the VUV photons in particle detectors, e.g. strong absorption by structural materials and low detection efficiency of the photosensors.Metasurfaces are relatively novel nano-fabricated devices which offer unprecedented control of light with a wide field of view and diffraction-limited focusing.This contribution will present the first linear metasurface lens operating in the VUV spectral range with the measured diffraction efficiencies above 50%.The design and fabrication processes will be described in detail, as well as the characterization measurements, and possible applications in the HEP experiments will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of the trigger performance of the ICARUS T600 detector at Fermilab

In recent years, experimental neutrino anomalies were reported: if confirmed, they could hint at the existence of additional sterile neutrino states participating in the mixing phenomenon. The future Short-Baseline Neutrino (SBN) project at Fermilab will pursue sterile neutrino searches, by exploiting three Liquid Argon (LAr) Time Projection Chamber (TPC) detectors located on-axis along the Booster Neutrino Beam (BNB). Aside from SBND and MicroBooNE, ICARUS will be the far detector and will also be interested by the NuMI beam (off-axis). The trigger system is a key component of the detector: it is based on the coincidence of prompt signals from scintillation light in the LAr-TPC (recorded by a system of PhotoMultiplier Tubes, PMTs) with the proton spill extraction of the beam. The present system exploits a majority-based logic and may be complemented by a trigger system based on adder boards, that add the analog signals of the PMTs in groups of 15. Triggering on the sum may help in identifying events closer to the TPC walls, in which there is plenty of light collected by few PMTs and for which the majority condition may not be satisfied. Many tests were carried out to characterize the adder boards, both on the hardware and software sides.

43 PARTICLE ACCELERATORS↗

Characterization and description of a spectrum unfolding method for the $\mathrm{CATRiNA}$ neutron detector array

We report the CATRiNA deuterated neutron detector array at Florida State University consists of 16 2" x 2" and 16 $" x 2" EJ-315 detectors with characteristic light output and pulse-shape discrimination capabilities. The unique properties of the detectors, in part due to the anisotropic nature of (d,n) scattering, are used to extract the energy of neutrons via pulse-height spectrum unfolding. The unfolding method uses the light output and response matrix of the detectors to extract neutron energies, independent of the traditional time-of-flight (ToF) technique. Detailed response matrices of the CATRiNA detectors were measured at the Edwards Accelerator Laboratory at Ohio University via the 9 Be(d,n) and 27 Al(d,n) reactions. Full characterization of the detectors using digital electronics, as well as a description of the unfolding method are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗