Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensible heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Thermal management of high power space based systems

Conventional techniques of using a portion of the spacecraft skin for radiation of waste heat will be inadequate for high powered payloads (50 to 100 kWe) due to the lack of sufficient area. A Shuttle type system using a pumped single phase fluid loop could be scaled up to higher power but this type of system would require excessive pump power and weight. A pumped two-phase heat transfer loop has a much lower pumping requirement due to the higher latent heat of vaporization of the fluid in comparison to the sensible heat it can absorb through a temperature change. Concepts for an evaporator and a condenser for a pumped two-phase system are described. The condenser uses capillary grooves and a separate pumped condensate return line to achieve high heat transfer coefficients and stable operation due to the separation of the vapor and liquid flows. The cold plate evaporator uses wicks to contain the liquid and transport it to the heated surface. It can also function as a condenser for warming components. Control concepts for the cold plate are discussed. Concepts for deployment or erection of large space radiators are also considered.

Hwangbo, H.↗

Assimilation of Satellite Soil Moisture for Improved Atmospheric Reanalyses

A newly developed, weakly coupled land and atmosphere data assimilation system for NASA’s Global Earth Observing System model is presented, and used to demonstrate the benefit of assimilating satellite soil moisture into an atmospheric reanalysis. Specifically, Advanced Scatterometer and Soil Moisture Ocean Salinity soil moisture retrievals are assimilated into a system that uses the same model, atmospheric assimilation system, and atmospheric observations as the Modern-Era Retrospective analysis for Research and Applications, version 2 (MERRA-2). The atmosphere is sensitive to soil moisture only under certain conditions. Hence, while the globally averaged model improvements were small, regionally, the soil moisture assimilation induced some substantial improvements. For example, in a large region spanning from western Europe across southern Russia, the soil moisture assimilation decreased the RMSE against independent station observations of daily maximum 2-m temperature (T(sup 2m, sub max)) by up to 0.4 K, and of 2-m specific humidity (q(exp 2m)) by up to 0.5 g/kg. Over all available stations, the mean T(sup 2m, sub max) RMSE was reduced from 2.82 to 2.79 K, while the mean q(exp 2m) RMSE was reduced from 1.25 to 1.20 g/kg. The soil moisture assimilation also reduced the mean RMSE across 29 flux tower sites from 34.2 to 32.6 Wm(exp −2) for latent heating, and from 37.7 to 36.5 Wm(exp −2) for sensible heating. For all variables evaluated, the soil moisture assimilation improved the model at monthly to seasonal, rather than daily, time scales. Based on the above experiments, it is recommended that satellite soil moisture be assimilated into future reanalyses, including the follow-on to MERRA-2.

Clara Draper↗

Experimental and Computational Investigation of Flow Boiling in Microgravity

This study explores use of Computational Fluid Dynamics (CFD) to predict near-saturated flow boiling of FC-72 in microgravity. The computational method employs transient analysis to predict detailed interfacial behavior and heat transfer characteristics along a rectangular channel heated along two opposite walls. Predicted results are validated against experimental temperature measurements and high-speed video images captured during a series of parabolic aircraft maneuvers for three sets of operating conditions which include variations of both mass velocity and wall heat flux. The computational method is based on the multi-phase volume of fluid (VOF) model, which is combined with appropriate phase change and turbulence models, and accounts for both shear-lift force on bubbles and conjugate heat transfer along the heating walls. A key advantage of the CFD method is ability to capture details that are very difficult to measure experimentally, including detailed spatial variations of bubble shape, void fraction, mixture fluid temperature, liquid velocity, and vapor velocity, results for which are presented for each of the three test cases. Different flow regimes predicted along the heated length exhibit a number of dominant mechanisms including bubble nucleation, bubble growth, coalescence, vapor blankets, interfacial waviness, and residual liquid sub-layer, all of which agree well with experiment. Vapor velocity is shown to increase appreciably along the heated length because of increased void fraction, while liquid velocity experiences large fluctuations. Non-equilibrium effects are accentuated with increasing mass velocity, contributing minor deviations of fluid temperature from simulations compared to those predicted by the analytical method. Predicted wall temperature is fairly uniform in the middle of the heated length but increases in the entrance region, due to sensible heat transfer in the subcooled liquid, and decreases toward the exit, mostly because of flow acceleration resulting from increased void fraction.

two-phase cooling; flow boiling; CFD; microgravity↗

Diabatic heating fields and the generation of available potential energy during FGGE

Global diabatic heating is estimated using fields of directly computed heating components, in particular those due to shortwave radiation, longwave radiation, sensible heating, and latent heating produced every 6 hours. The role of average fields of diabatic heating in the generation of available potential energy is examined. It is observed that latent heating is most significant in generating available potential energy.

Salstein, David A.↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Analysis of the surface heat balance over the world ocean

It is possible to estimate long term monthly mean latent and sensible heat fluxes over the ocean to within or approximately 20% relative accuracy of the bulk aerodynamic formulas, by using observations of the monthly mean surface wind speed and the monthly mean sea air temperature and humidity differences. It is possible to make an estimate of the fluxes on a month to month basis from monthly averaged surface data.

Esbensen, S. K.↗

Strong influence of convective heat transfer efficiency on the cooling benefits of green roof irrigation

Abstract By enhancing evapotranspiration (ET), green roofs provide cooling benefits for the urban environment and are recognized as a promising heat mitigation strategy. The evaporative cooling effects of green roofs strongly depend on the soil moisture conditions and thus irrigation may be needed to sustain the cooling benefits. It has been shown that the magnitude of cooling benefits offered by green roof irrigation varies spatially, but its controlling factors remain elusive. In this study, we combine a surface energy balance (SEB) model with global simulations generated by an improved Earth System Model to illustrate the key factors controlling the cooling benefits of green roof irrigation. We employ a simple irrigation scheme, which is only active when there is no ice in soil layers and when the soil moisture is below field capacity. As a result, most of the irrigation water leaves the green roof system via ET. We find that the magnitude and also the spatial variability of the cooling benefits of green roof irrigation are controlled by the irrigation amount, and a surface energy redistribution factor that encodes the efficiencies of different SEB components in transferring heat. Further analysis indicates that the enhancement of latent heat flux due to irrigation is largely balanced by the reduction of sensible heat flux on green roofs. Therefore, the amount of irrigation needed per unit decrease of green roof surface temperature is mainly controlled by the convective heat transfer efficiency. A lower convective heat transfer efficiency (e.g. under a lower wind speed) helps reduce the amount of irrigation needed per unit decrease of green roof surface temperature. This study highlights the importance of SEB in constraining the cooling benefits of green roof irrigation and provides valuable guidance for urban planners and policy makers in terms of heat mitigation and sustainable water management.

Wang, Linying (ORCID:0000000308769220)↗

Atmospheric model development in support of SEASAT. Volume 3: Prediction models

As part of the SEASAT program of NASA, a set of four hemispheric, atmospheric models are developed. The four models use a polar stereographic grid in the horizontal and a sigma coordinate in the vertical. Conservation forms of the difference equations are integrated using either a fifteen or four minute time step on a 381 km or 127 km grid (at 60 deg N) for the 63 x 63 or 187 x 187 models respectively. A nonlinear pressure smoother is used along with momentum and temperature diffusion to help control computational noise. The horizontal boundary conditions are insulated slippery walls. Centered time differencing with time averaging of the pressure gradient force term in the momentum equations is used. Robert time filtering on of the temperature and moisture solutions is used for computational stability. The moisture and heat source/sink terms are modeled. Terms representing evaporation and large scale condensation, sensible heat exchange, parameterized cumulus convection and precipitation, and solar and terrestrial radiation are included. Initialization of the models is based on a pattern conservation technique to obtain objective analysis of the state parameter structure from the surface to 50 mb.

Wellck, R. E.↗

A study of the surface energy balance on slopes in a tallgrass prairie

Four slopes (north, south, east, and west) were selected on the Konza Prairie Research Natural Area to study the effect of topography on surface energy balance and other micrometeorological variables. Energy fluxes, air temperature, and vapor pressure were measured on the sloped throughout the 1988 growing season. Net radiation was the highest on the south-facing slope and lowest on the north-facing slope, and the difference was more than 150 W/sq m (20 to 30 percent) at solar noon. For daily averages, the difference was 25 W/sq m (15 percent) early in the season and increased to 60 W/sq m (30 to 50 percent) in September. The east-facing and west-facing slopes had the same daily average net radiation, but the time of day when maximum net radiation occurred was one hour earlier for the east-facing slope and one hour later for the west-facing slope relative to solar noon. Soil heat fluxes were similar for all the slopes. The absolute values of sensible heat flux (h) was consistently lower on the north-facing slope compared with other slopes. Typical difference in the values of H between the north-facing and the south-facing slopes was 15 to 30 W/sq m. The south-facing slope had the greatest day to day fluctuation in latent heat flux as a result of interaction of net radiation, soil moisture, and green leaf area. The north-facing slope had higher air temperatures during the day and higher vapor pressures both during the day and at night when the wind was from the south.

Nie, D.↗

Precipitation rates in the tropics based on the Q1-budget method - 1 June 1984-31 May 1987

The 'apparent' heat source method (Q1 budget) is used to compute the total derivative of dry static energy from 30 deg N to 30 deg S for the period June 1, 1984-May 31, 1987. The dataset is produced from the ECMWF global analyses and consists of twice-daily values of temperature, geopotential height, horizontal wind components, and vertical velocity at increments of 2.5 x 2.5 deg lat/long at seven pressure levels. Vertically integrated values of ds/dt, which are equal to total diabatic heating, Q1, are combined with estimates of net columnar radiation and surface sensible heat exchange to compute mean monthly precipitation rates, P0, as the residual in the Q1 budget. The accuracy of these P0 values is thoroughly examined, and it is suggested that the technique produces reliable estimates of precipitation over tropical oceanic areas on a monthly basis. Time series of mean monthly P0 for several geographic regions of the Southern Hemisphere tropics and the equatorial western Pacific (TOGA-COARE region) reveal that (1) the South Pacific convergence zone has the highest precipitation rates in the Southern Hemisphere; (2) a clear and distinct seasonal cycle is prominent in all regions; and (3) the 1986-87 ENSO event is easily identified, particularly in the TOGA-COARE region.

Vincent, Dayton G.↗

Surface energy fluxes on four slope sites during FIFE 1988

Four slopes (facing north, south, east, and west) in the Konza Prairie Research Natural Area were selected to study the effect of topography on surface energy balance and other micrometeorological variables. Energy fluxes, air temperature, and vapor pressure were measured on the slopes throughout the 1988 growing season. Net radiation was highest on the south facing slope and lowest on the north facing slope, and the difference was more than 150 W/sq m (20-30 percent) at solar noon. For daily averages the difference was about 25 W/sq m (15 percent) early in the season and increased to about 60 W/sq m (30-50 percent) in September. Soil heat fluxes were similar for all the slopes. The absolute values of sensible heat flux were consistently lower on the north facing slope compared with other slopes. The south facing slope had the greatest day-to-day fluctuation in latent heat flux as a result of the interaction of net radiation, soil moisture, and green leaf area. Differences were found in the partitioning of the available energy among the slopes, and the north facing slope had a higher percentage of energy dissipated into latent heat flux. The north facing slope had higher air temperatures during the day and higher vapor pressures both during the day and at night when the wind was from the south.

Nie, D.↗

Mechanisms Associated with Daytime and Nighttime Heat Waves over the Contiguous United States

Heat waves are extreme climate events that have the potential to cause immense stress on human health, agriculture, and energy systems, so understanding the processes leading to their onset is crucial. There is no single accepted definition for heat waves, but they are generally described as a sustained amount of time where temperature exceeds a local threshold. Multiple different temperature variables are potentially relevant, as high values of both daily maximum (Tmax) and minimum (Tmin) temperatures can be detrimental to human health. In this study, we focus explicitly on the different mechanisms associated with summertime heat waves manifested during daytime versus nighttime hours over the contiguous United States. Heat waves are examined using the National Aeronautics and Space Administration (NASA) Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2). Over 1980–2018, the increase in the number of heat wave days per summer was generally stronger for nighttime heat wave days than daytime heat wave days, with localized regions of significant positive trends. Processes linked with daytime and nighttime heat waves are identified through composite analysis of precipitation, soil moisture, clouds, humidity and fluxes of heat and moisture. Daytime heat waves are associated with dry conditions, reduced cloud cover, and increased sensible heating. Mechanisms leading to nighttime heat waves differ regionally across the US, but they are typically associated with increased clouds, humidity and/or low-level temperature advection. In the Midwest US, enhanced moisture is transported from the Gulf of Mexico during nighttime heat waves.

Extreme events↗

Modeling tropical Pacific sea surface temperature with satellite-derived solar radiative forcing

Two independent datasets for the solar radiation at the surface derived from satellites are compared. The data derived from the Earth Radiation Budget Experiment (ERBE) is for the net solar radiation at the surface whereas the International Satellite Cloud Climatology Project (ISCCP) data is for the downward flux only and was corrected with a space- and time-varying albedo. The ISCCP net flux is at all times higher than the ERBE flux. The difference can be divided into an offset that decreases with latitude and another component that correlates with high tropical cloud cover. With this latter exception the two datasets provide spatial patterns of solar flux that are very similar. A tropical Pacific Ocean model is forced with these two datasets and observed climatological winds. The upward heat flux is parameterized taking into account separately the longwave radiative, latent, and sensible heat fluxes. Best fit values for the uncertain parameters are found using an optimization procedure that seeks to minimize the difference between model and observed SST by varying the parameters within a reasonable range of uncertainty. The SST field the model produces with the best fit parameters is the best the model can do. If the differences between the model and data are larger than can be accounted for by remaining uncertainties in the heat flux parameterization and forcing data then the ocean model must be held to be at fault. Using this method of analysis, a fundamental model fault is identified. Inadequate treatment of mixed layer/entrainment processes in upwelling regions of the eastern tropical Pacific leads to a large and seasonally varying error in the model SST. Elsewhere the model SST is insufficiently different from observed to be able to identify model errors.

Seager, Richard↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Development of Numerical Model of Metal Foam with PCM for the Estimation of Effective Thermal Conductivity

Global warming due to climate change is a threat to humankind. Nuclear energy is one of the promising solutions to reduce fossil fuel usage. Nuclear energy can handle the base load, compensating for the volatility of renewable energy. If nuclear energy could achieve load following capability, the combination with renewable energy would be more suitable. Thermal energy storage (TES) is one of the options for enabling load following of nuclear reactors. The TES makes it possible to store surplus nuclear thermal energy and release it later as needed. In Idaho National Laboratory (INL), a new concept of latent heat TES integrated with high-temperature heat pipe has been proposed and is under development, which is called Heat pipe-Integrated Thermal Battery (HITB). HITB exchanges thermal energy between the reactor system and TES via heat pipe. The heat transferred to TES medium, made of phase change material (PCM), stores energy as sensible heat and/or latent heat. As PCM typically has poor thermal conductivity, however, various heat transfer enhancement techniques are required to achieve a rapid charging cycle. There are many techniques to enhance the heat transfer ability of TES medium such as disk, fin, and metal foam. Among them, metal foam is an appropriate option to enhance the heat transfer because it maximizes the heat transfer area through metal wicks. Metal foam is a lightweight metal structure that has a high porosity of over 0.9. The typical materials for metal foam are Aluminum, Copper, Nickel, and Silicon Carbide (SiC). Metal foam not only enhances heat transfer via conduction but also increases contact surface area. In the HITB design , the metal foam is being considered as one of the options to enhance the heat transfer of TES medium (PCM) [1]. To predict the enhanced thermal performance of TES, one should properly estimate the effective thermal conductivity of metal foam combined with PCM material or calculate heat transfer in distributed model. There are many experimental works that provides effective thermal conductivity of metal foam with various PCM [2,3]. Also, many theoretical models were developed based on the unit cell model of metal foam [4,5]. With a distributed model, on the other hand, detail heat transfer characteristics between metal foam and PCM material can be analyzed considering the geometry or buoyancy effect. However, due to the complex geometry of metal foam pores, the computational cost for three-dimensional modeling highly increases. Therefore, if metal foam structure can be modeled in simple and repetitive design, the computational cost would decrease Among the various metal foam models [2], lattice model is one of the simple and extendable design. The porosity and pores per inch (PPI) can be characterized by the size and spatial distance of lattice structure. If the three-dimensional metal foam model consists of lattice structure could properly estimate the heat transfer, which is characterized by effective thermal conductivity, it would be a good option to assess the thermal performance of metal foam with PCM. In this study, a three-dimensional numerical model was developed to simulate conductive heat transfer between metal foam and PCM. The three-dimensional lattice structure of square pillars was selected as a basic structure of the metal foam. The calculation result was characterized by the effective thermal conductivity of the whole domain. A sensitivity study was conducted for mesh size, domain size, and PPI to check whether the calculation result gives a converged result or not. Lastly, the effective thermal conductivity from the lattice model was compared with existing experimental data to validate the model result

25 ENERGY STORAGE↗

Estimating ocean-air heat fluxes during cold air outbreaks by satellite

Nomograms of mean column heating due to surface sensible and latent heat fluxes were developed. Mean sensible heating of the cloud free region is related to the cloud free path (CFP, the distance from the shore to the first cloud formation) and the difference between land air and sea surface temperatures, theta sub 1 and theta sub 0, respectively. Mean latent heating is related to the CFP and the difference between land air and sea surface humidities q sub 1 and q sub 0 respectively. Results are also applicable to any path within the cloud free region. Corresponding heat fluxes may be obtained by multiplying the mean heating by the mean wind speed in the boundary layer. The sensible heating estimated by the present method is found to be in good agreement with that computed from the bulk transfer formula. The sensitivity of the solutions to the variations in the initial coastal soundings and large scale subsidence is also investigated. The results are not sensitive to divergence but are affected by the initial lapse rate of potential temperature; the greater the stability, the smaller the heating, other things being equal. Unless one knows the lapse rate at the shore, this requires another independent measurement. For this purpose the downwind slope of the square of the boundary layer height is used, the mean value of which is also directly proportional to the mean sensible heating. The height of the boundary layer should be measurable by future spaceborn lidar systems.

Chou, S. H.↗