Search NASA⌕ Search

SEARCH · Search NASA

Results for “sequencing test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Experimental Results and Interfacial Lift-off Model Predictions of Critical Heat Flux for Flow Boiling with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

This study investigates critical heat flux (CHF) for subcooled flow boiling of n-Perfluorohexane based on results of pre-launch Earth-gravity Mission Sequence Tests (MSTs) of the Flow Boiling and Condensation Experiment (FBCE), which was launched to the International Space Station (ISS) in August 2021. CHF measurements were made in a rectangular channel having a 2.5 mm by 5 mm cross-section and a 114.6-mm long heated segment. Both single-sided and double-sided heating were tested in vertical upflow in Earth gravity for a variety of inlet conditions. The inlet subcooling was varied in the range of 0.4 – 32.0°C and encompassed both near-saturated and highly subcooled conditions. Experimental trends and high-speed video records were investigated to better understand the mechanism of CHF. Overall trends show CHF increases as flow rate and/or inlet subcooling are increased. Flow features from the events around CHF justify the applicability of the Interfacial Lift-off Model and the determination of limiting criteria for its application. The present experimental data are combined with prior databases for various flow orientations with respect to Earth gravity and microgravity data collected on parabolic flights. Predictions are made using the Interfacial Lift-off Model for this consolidated subcooled-inlet FBCE-CHF database. A heat utility ratio was included in the model to capture the effects of subcooling and corresponding thermodynamic non-equilibrium. An overall mean absolute error of 19.04% indicates good predictive capability of the model for both heating configurations, different gravity environments, and a wide range of inlet subcooling.

flow boiling↗

Experimental Heat Transfer Results and Flow Visualization of Vertical Upflow Boiling in Earth Gravity with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

Since 2012, researchers at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and NASA Glenn Research Center have been collaborating on a long-term effort to study flow boiling and condensation in microgravity. The ultimate goal has been to develop the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS). Based on the findings from prior flow boiling experiments both at different orientations in Earth gravity and onboard parabolic flights simulating short durations of microgravity, a final refined experiment design, construction, and operating procedure have been arrived at for long-duration microgravity flow boiling experiments onboard the ISS. This study investigates flow boiling of n-Perfluorohexane with subcooled inlet in a rectangular channel of dimensions 114.6 mm heated length, 2.5 mm width, and 5 mm height. These pre-launch experiments (Mission Sequence Testing) were conducted in vertical upflow orientation in Earth gravity using the same experimental rig that was launched to the ISS in August 2021. The various operating parameters varied are heating configuration (single- and double-sided), mass velocity (180 – 3200 kg/m2s), inlet subcooling (+0 – 32°C, encompassing both highly subcooled and near-saturated inlet conditions), and inlet pressure (119 – 191 kPa). High-speed video flow visualization images are presented to explain the two-phase interfacial physics within the channel’s heated section. Heat transfer results in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and averaged heat transfer coefficients are analyzed and parametric effects elucidated. Severe temporal thermodynamic equilibrium is observed for near-saturated inlet at very low velocities. Nucleate boiling degradation starts at larger heat fluxes for single-sided heating than double sided at low mass velocities with highly subcooled inlet, and conversely at high mass velocities with near-saturated inlet. Nucleate boiling degradation can be delayed to higher heat fluxes by highly subcooling the inlet and increasing mass velocity. The entire local heat transfer coefficient profiles are degraded at higher heat fluxes for near-saturated inlet, but only the downstream part for highly subcooled inlet. This study also confirmed reliability of the upcoming ISS experimental data for subcooled inlet conditions and the collected Earth-gravity data will be used for comparison against the ISS data.

flow boiling↗

Flow Visualization, Heat Transfer, and Critical Heat Flux of Flow Boiling in Earth Gravity with Saturated Liquid-Vapor Mixture Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

This study investigates flow boiling of n-Perfluorohexane with saturated two-phase mixture inlet in a rectangular channel of dimensions 114.6-mm heated length, 2.5-mm width, and 5 mm-height. The experiments were performed as part of the Mission Sequence Testing of the Flow Boiling and Condensation Experiment’s (FBCE) Flow Boiling Module (FBM) in the vertical upflow configuration in Earth gravity using the same experimental system that was launched to the International Space Station (ISS) in August 2021. The operating parameters varied are heating configuration (single- and double-sided), mass velocity (380 – 2400 kg/m2s), inlet quality (0.011 – 0.519), and inlet pressure (120 – 179 kPa). High-speed video photographs are presented to explain the two-phase flow patterns within the channel’s heated length. Flow patterns are constituted by low-density and high-density fronts moving along the channel, with the high-density fronts gradually reducing in length due to evaporation. Heat transfer results in terms of flow boiling curves, streamwise wall temperature profiles, streamwise heat transfer coefficient profiles, and average heat transfer coefficients are presented and trends discussed. CHF data from the present experiments are combined with prior databases to compile a consolidated FBCE-CHF database for saturated inlet to expand the ranges of operating conditions and include other flow orientations in Earth gravity. Experimental CHF trends are also discussed. The interfacial lift-off model shows a good CHF predictive accuracy evidenced by a mean absolute error of 11.97% for this consolidated database after constraining it to mass velocities greater than or equal to 500 kg/m2s. Finally, this study confirmed reliability of the upcoming ISS experiments for saturated inlet conditions and the collected Earth-gravity data will be compared to ISS microgravity data.

Flow boiling↗

Flow Boiling & Condensation Experiment (FBCE): Flow Boiling in Earth Gravity and Onboard the International Space Station

Two phase thermal management systems that capitalize on both latent and sensible heats of the working fluid can yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients and reduce size and weight of future space systems. Because the understanding of microgravity influences on two-phase flow and heat transfer is quite limited, there is presently an urgent need for a new experimental microgravity facility to enable investigators to perform long-duration flow boiling and condensation experiments in pursuit of reliable databases. This presentation will discuss results from the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between Purdue University and NASA Glenn Research Center. Experiments have been performed using the final system with the Flow Boiling Module (FBM) in vertical orientation in Earth gravity (Mission Sequence Tests, MST) and in microgravity onboard the International Space Station (ISS). High-speed-video flow visualization, heat transfer, and critical heat flux (CHF) results from the MST are presented for both subcooled liquid and saturated liquid-vapor inlet conditions. CHF predictions made using the Interfacial Lift-off Model are compared with a consolidated database made by compiling FBM datasets obtained in prior years for different orientations in Earth gravity and on parabolic flights. New explicit correlations for CHF and subcooled flow boiling heat transfer coefficient are developed and shown to be excellent in their predictive accuracies against consolidated experimental databases. Computations are performed for flows in microgravity and horizontal flows in Earth gravity, the results of which show a good predictive accuracy for both void fraction and wall temperature. Finally, similar preliminary results from the recent ISS experiments are presented.

Issam Mudawar↗

Integration of SARS-CoV-2 testing and genomic sequencing into influenza sentinel surveillance in Uganda, January to December 2022

The Uganda Virus Research Institute, National Influenza Center laboratory integrated SARS-CoV-2 polymerase chain reaction testing and genomic sequencing into the influenza surveillance program that was established in 2007. A total of 7,698 nasopharyngeal/oropharyngeal (NP/OP) swab samples were collected and analyzed from ILI/SARI sentinel sites across the country from January to December 2022. All samples were tested for influenza and SARS-CoV-2. Of these, 252 (3.3%), 162 (2.1%), and 589 (7.7%) were positive for influenza A, influenza B, and SARS-CoV-2, respectively. Out of 414 influenza-positive samples, 122 (29.5%) were AH1pdm09, 130 (31.4%) were AH3, and 162 (39.1%) were B-Victoria. All SARS-CoV-2 sequenced samples were of the Omicron variant, with subvariants of concern known to evade the immune system being detected, such as BQ.1 and XBB.2. Other SARS-CoV-2 positive samples collected from other health centers in the community outside the surveillance sites were included into SARS-CoV-2 genomic sequencing with similar patterns with respect to variants. In all, the ILI/SARI surveillance system has shown to be an efficient, cost-effective, and sustainable program, providing a ready platform to monitor the circulation of SARS-CoV-2 in communities at the national level while remaining vigilant for the persistent threat of influenza. The integration of SARS-CoV-2 detection and genomic surveillance into the influenza surveillance program will strengthen the laboratory response capacity, as well as facilitate the timely release of SARS-CoV-2 genomic information to be used to complement the multiple response strategies for COVID-19 pandemic mitigation.

59 BASIC BIOLOGICAL SCIENCES↗

A Pattern Dictionary Method for Anomaly Detection

In this paper, we propose a compression-based anomaly detection method for time series and sequence data using a pattern dictionary. The proposed method is capable of learning complex patterns in a training data sequence, using these learned patterns to detect potentially anomalous patterns in a test data sequence. The proposed pattern dictionary method uses a measure of complexity of the test sequence as an anomaly score that can be used to perform stand-alone anomaly detection. We also show that when combined with a universal source coder, the proposed pattern dictionary yields a powerful atypicality detector that is equally applicable to anomaly detection. The pattern dictionary-based atypicality detector uses an anomaly score defined as the difference between the complexity of the test sequence data encoded by the trained pattern dictionary (typical) encoder and the universal (atypical) encoder, respectively. We consider two complexity measures: the number of parsed phrases in the sequence, and the length of the encoded sequence (codelength). Specializing to a particular type of universal encoder, the Tree-Structured Lempel–Ziv (LZ78), we obtain a novel non-asymptotic upper bound, in terms of the Lambert W function, on the number of distinct phrases resulting from the LZ78 parser. This non-asymptotic bound determines the range of anomaly score. As a concrete application, we illustrate the pattern dictionary framework for constructing a baseline of health against which anomalous deviations can be detected.

97 MATHEMATICS AND COMPUTING↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence K - Raw Data

Sequence K: Step AOA, Probes (P) This sequence was designed to quantify the 3-D blade static angle-of-attack response in the presence of rotational influences by varying the blade pitch angle. Sequence K used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 6 m/s to 20 m/s, and data were collected at yaw angles of 0° and 30°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°, the flow was allowed to stabilize, and the pitch angle was held for 8 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 96 seconds to 6 minutes, depending on the pitch angle range. Some short points were collected at 0° yaw and 3° pitch to verify the functionality of the instrumentation. The file name convention used the initial letter K, followed by two digits specifying wind speed, followed by two digits for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle-of-attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down then step up). This sequence is related to sequences L and R.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 3 - Raw Data

Sequence 3: Tower Wake Measure (P) Sequence 3 used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds for this sequence corresponded to subcritical [7 m/s], transitional [15 m/s], and supercritical [20 m/s] Reynolds number regimes for the circular cross-section tower. The yaw angle and blade tip pitch angles were selected to traverse the probe tip across the tower wake, while keeping the probe axis approximately parallel to the tunnel centerline. The rotor was parked with the instrumented blade at 180° azimuth. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

The Jimsonde - A high resolution temperature sensor.

The Jimsonde, a high-resolution lightweight temperature sensor developed for use with the FPS-16 Radar/Jimsphere wind system, and its related systems are discussed; and an error analysis that shows the sonde to have an rms error of 0.41 C at sea level and 0.56 C at 18 km is presented. Five flight tests, a sequence of four tests and one individual test, of the Jimsonde were made. For comparative purposes, radiosonde temperature data are presented along with the Jimsonde data.

Camp, D. W.↗

The NASA computer aided design and test system

A family of computer programs facilitating the design, layout, evaluation, and testing of digital electronic circuitry is described. CADAT (computer aided design and test system) is intended for use by NASA and its contractors and is aimed predominantly at providing cost effective microelectronic subsystems based on custom designed metal oxide semiconductor (MOS) large scale integrated circuits (LSIC's). CADAT software can be easily adopted by installations with a wide variety of computer hardware configurations. Its structure permits ease of update to more powerful component programs and to newly emerging LSIC technologies. The components of the CADAT system are described stressing the interaction of programs rather than detail of coding or algorithms. The CADAT system provides computer aids to derive and document the design intent, includes powerful automatic layout software, permits detailed geometry checks and performance simulation based on mask data, and furnishes test pattern sequences for hardware testing.

Gould, J. M.↗

Omega flight-test data reduction sequence

Computer programs for Omega data conversion, summary, and preparation for distribution are presented. Program logic and sample data formats are included, along with operational instructions for each program. Flight data (or data collected in flight format in the laboratory) is provided by the Ohio University Omega receiver base in the form of 6-bit binary words representing the phase of an Omega station with respect to the receiver's local clock. All eight Omega stations are measured in each 10-second Omega time frame. In addition, an event-marker bit and a time-slot D synchronizing bit are recorded. Program FDCON is used to remove data from the flight recorder tape and place it on data-processing cards for later use. Program FDSUM provides for computer plotting of selected LOP's, for single-station phase plots, and for printout of basic signal statistics for each Omega channel. Mean phase and standard deviation are printed, along with data from which a phase distribution can be plotted for each Omega station. Program DACOP simply copies the Omega data deck a controlled number of times, for distribution to users.

Lilley, R. W.↗

Masking by Gratings Predicted by an Image Sequence Discriminating Model: Testing Models for Perceptual Discrimination Using Repeatable Noise

Adding noise to stimuli to be discriminated allows estimation of observer classification functions based on the correlation between observer responses and relevant features of the noisy stimuli. Examples will be presented of stimulus features that are found in auditory tone detection and visual vernier acuity. using the standard signal detection model (Thurstone scaling), we derive formulas to estimate the proportion of the observers decision variable variance that is controlled by the added noise. one is based on the probability of agreement of the observer with him/herself on trials with the same noise sample. Another is based on the relative performance of the observer and the model. When these do not agree, the model can be rejected. A second derivation gives the probability of agreement of observer and model when the observer follows the model except for internal noise. Agreement significantly less than this amount allows rejection of the model.

Ahumada, Albert J., Jr.↗

Test Input Generation for Red-Black Trees using Abstraction

We consider the problem of test input generation for code that manipulates complex data structures. Test inputs are sequences of method calls from the data structure interface. We describe test input generation techniques that rely on state matching to avoid generation of redundant tests. Exhaustive techniques use explicit state model checking to explore all the possible test sequences up to predefined input sizes. Lossy techniques rely on abstraction mappings to compute and store abstract versions of the concrete states; they explore under-approximations of all the possible test sequences. We have implemented the techniques on top of the Java PathFinder model checker and we evaluate them using a Java implementation of red-black trees.

Visser, Willem↗

Irreducible Tests for Space Mission Sequencing Software

As missions extend further into space, the modeling and simulation of their every action and instruction becomes critical. The greater the distance between Earth and the spacecraft, the smaller the window for communication becomes. Therefore, through modeling and simulating the planned operations, the most efficient sequence of commands can be sent to the spacecraft. The Space Mission Sequencing Software is being developed as the next generation of sequencing software to ensure the most efficient communication to interplanetary and deep space mission spacecraft. Aside from efficiency, the software also checks to make sure that communication during a specified time is even possible, meaning that there is not a planet or moon preventing reception of a signal from Earth or that two opposing commands are being given simultaneously. In this way, the software not only models the proposed instructions to the spacecraft, but also validates the commands as well.To ensure that all spacecraft communications are sequenced properly, a timeline is used to structure the data. The created timelines are immutable and once data is as-signed to a timeline, it shall never be deleted nor renamed. This is to prevent the need for storing and filing the timelines for use by other programs. Several types of timelines can be created to accommodate different types of communications (activities, measurements, commands, states, events). Each of these timeline types requires specific parameters and all have options for additional parameters if needed. With so many combinations of parameters available, the robustness and stability of the software is a necessity. Therefore a baseline must be established to ensure the full functionality of the software and it is here where the irreducible tests come into use.

sequencing test↗

Solid rocket booster thrust vector control subsystem test report (D-1)

The results of the sequence of tests performed on the space shuttle solid rocket booster thrust vector control subsystem are presented. The operational characteristics of the thrust vector control subsystem components, as determined from the tests, are discussed. Special analyses of fuel consumption, basic steady state characteristics, GN2 spin, and actuator displacement were reviewed which will aid in understanding the performance of the auxiliary power unit. The possibility of components malfunction is also discussed.

Pagan, B.↗

Comparison of Fault Detection Algorithms for Real-time Diagnosis in Large-Scale System

In this paper, we present a review of different real-time capable algorithms to detect and isolate component failures in large-scale systems in the presence of inaccurate test results. A sequence of imperfect test results (as a row vector of I's and O's) are available to the algorithms. In this case, the problem is to recover the uncorrupted test result vector and match it to one of the rows in the test dictionary, which in turn will isolate the faults. In order to recover the uncorrupted test result vector, one needs the accuracy of each test. That is, its detection and false alarm probabilities are required. In this problem, their true values are not known and, therefore, have to be estimated online. Other major aspects in this problem are the large-scale nature and the real-time capability requirement. Test dictionaries of sizes up to 1000 x 1000 are to be handled. That is, results from 1000 tests measuring the state of 1000 components are available. However, at any time, only 10-20% of the test results are available. Then, the objective becomes the real-time fault diagnosis using incomplete and inaccurate test results with online estimation of test accuracies. It should also be noted that the test accuracies can vary with time --- one needs a mechanism to update them after processing each test result vector. Using Qualtech's TEAMS-RT (system simulation and real-time diagnosis tool), we test the performances of 1) TEAMSAT's built-in diagnosis algorithm, 2) Hamming distance based diagnosis, 3) Maximum Likelihood based diagnosis, and 4) HidderMarkov Model based diagnosis.

Kirubarajan, Thiagalingam↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2

This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.

Platt, R.↗

Particle Filter Based Inference Testing

The primary intent of PAR-FIT (Particle Filter based Inference Testing) is to provide hard inductive evidence that a machine learning model is capable and proven for an individual test input. By examining training data used to form the underlying model functional correlation, an estimate of the reliability that a model will make the correct prediction can be made. The Sequential Probability Ratio Test is used to derive a qualitative evaluation for reliability based on hypothesis testing. The PAR-FIT framework achieves this by implementing a particle filter and the sequential probability ratio test algorithms on the machine learning model training data to determine relevancy of new individual test samples to the training dataset. The kernel function evaluates the local proximity and density of training data used to derive a prediction outcome. Particles are used to probabilistically determine which training data to evaluate for proximity. For test samples that are within a close proximity to and surrounded by multiple training data points, the evaluated reliability of the prediction is high. For test samples that are anomalies not represented by the training dataset, in low density data clusters, or are far from existing data points, the evaluated reliability is low as insufficient training evidence exists to suggest the model is capable of making the correct prediction. Sequential Probability Ratio Test is further used to determine when a hypothesis on whether a signal can be rejected or accepted for use. The ratio test collects sequence information from the particle filter to test whether the signal is anomalous or normal via hypothesis testing of the underlying distributions.

Chen, Edward [Idaho National Laboratory (INL), Ida↗