A High Dynamic-Range Photon-Counting Receiver for Deep Space Optical Communication

The Deep Space Optical Communication (DSOC) project will demonstrate free-space optical communication at almost 3 AU, or 3 orders of magnitude further than any previous attempt. DSOC will utilize the 5m Palomar Hale Telescope to receive the downlink signal, which will couple the downlink light onto an optical table and into a superconducting nanowire single photon detector (SNSPD). The output of the SNSPD is digitized by the Ground Laser Receiver Signal Processing Assembly (GSPA) using a high throughput streaming time to digital converter (TDC). The GSPA is a scalable FPGA-based receiver which demodulates and decodes the DSOC downlink signal through novel signal processing algorithms implemented on Xilinx UltraScale+ FPGAs, as well as Python-based software monitor and control routines. Exploiting the unique TDC-based architecture, the GSPA supports over four orders of magnitude of downlink data rates across multiple orders of magnitude of signal and background powers. In this paper we present an overview of the hardware, firmware and software architectures to implement this system, as well as performance analysis for links ranging from near-Earth to 2.8 AU.

Srinivasan, Meera↗

The Ice, Cloud, and Land Elevation Satellite-2 Mission: A Global Geolocated Photon Product Derived from the Advanced Topographic Laser Altimeter System

The Ice, Cloud, and land Elevation Satellite – 2 (ICESat-2) observatory was launched on 15 September 2018 to measure ice sheet and glacier elevation change, sea ice freeboard, and enable the determination of the heights of Earth’s forests. ICESat-2’s laser altimeter, the Advanced Topographic Laser Altimeter System (ATLAS) uses green (532 nm) laser light and single-photon sensitive detection to measure time of flight and subsequently surface height along each of its six beams. In this paper, we describe the major components of ATLAS, including the transmitter, the receiver and the components of the timing system. We present the major components of the ICESat-2 observatory, including the Global Positioning System, star trackers and inertial measurement unit. The ICESat-2 Level 1B data product (ATL02) provides the precise photon round-trip time of flight, among other data. The ICESat-2 Level 2A data product (ATL03) combines the photon times of flight with the observatory position and attitude to determine the geodetic location (i.e. the latitude, longitude and height) of the ground bounce point of photons detected by ATLAS. The ATL03 data product is used by higher-level (Level 3A) surface-specific data products to determine glacier and ice sheet height, sea ice freeboard, vegetation canopy height, ocean surface topography, and inland water body height.

ICESat-2↗

On Approaching the Ultimate Limits of Communication Using a Photon-Counting Detector

Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement scheme is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We analyze two binary modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with the state-of-the-art coherent-state on-off keying modulation. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

photon-counting measurement↗

Approaching the Ultimate Limits of Communication Efficiency with a Photon-Counting Detector

Coherent states achieve the Holevo capacity of a pure-loss channel when paired with an optimal measurement, but a physical realization of this measurement is as of yet unknown, and it is also likely to be of high complexity. In this paper, we focus on the photon-counting measurement and study the photon and dimensional efficiencies attainable with modulations over classical- and nonclassical-state alphabets. We first review the state-of-the-art coherent on-off-keying (OOK) with a photoncounting measurement, illustrating its asymptotic inefficiency relative to the Holevo limit. We show that a commonly made Poisson approximation in thermal noise leads to unbounded photon information efficiencies, violating the conjectured Holevo limit. We analyze two binary-modulation architectures that improve upon the dimensional versus photon efficiency tradeoff achievable with conventional OOK. We show that at high photon efficiency these architectures achieve an efficiency tradeoff that differs from the best possible tradeoff--determined by the Holevo capacity--by only a constant factor. The first architecture we analyze is a coherent-state transmitter that relies on feedback from the receiver to control the transmitted energy. The second architecture uses a single-photon number-state source.

thermal noises↗

Free-Free Transitions of the e-H System Inside a Dense Plasma Irradiated by a Laser Field at Very Low Incident-Electron Energies

The free-free transition is studied for an electron-hydrogen atom in ground state when a low-energy electron (external) is injected into hydrogenic plasma in the presence of an external homogenous, monochromatic, and linearly polarized laser field. The effect of plasma screening is considered in the Debye-Huckel approximation. The calculations are performed in the soft photon limit. The incident electron is considered to be dressed by the laser field in a nonperturbative manner by choosing the Volkov solutions in both the initial and final channels. The space part of the scattering wave function for the electron is solved numerically by taking into account the electron exchange. The laser-assisted differential and total cross sections are calculated for single-photon absorption or emission and no-photon exchange in the soft photon limit, the laser intensity being much less than the atomic field intensity. The calculations have been carried out for various values of Debye parameter, ranging from 0.005 to 0.12. A strong suppression is noted in the laser-assisted cross sections as compared to the field-free situation. A significant difference is noted for the singlet and triplet cross sections. The suppression is much more in the triplet states.

Bhatia, A. K.↗

Airborne Demonstration of Atmospheric Oxygen Optical Depth Measurements with an Integrated Path Differential Absorption Lidar

We report on an airborne demonstration of atmospheric oxygen (O2) optical depth measurements with an Integrated Path Differential Absorption (IPDA) lidar using a fiber-based laser transmitter and photon counting detectors. Accurate atmospheric temperature and pressure measurements are needed for NASA's Active Sensing of CO2 Emissions over Nights, Days and Seasons (ASCENDS) mission. Since O2 is uniformly mixed in the atmosphere, its spectrum can be used to estimate the dry mixing ratio of CO2. In its airborne configuration, the IPDA lidar uses an Erbium Doped Fiber amplifier, a frequency doubler and single photon counting detectors to measure O2 absorption at multiple wavelengths near 765 nm. This instrument was deployed in 2013 and 2014 aboard NASA's DC-8 airborne laboratory as part of two campaigns to measure CO2 mixing ratios over a wide range of topography and weather conditions from altitudes ranging between 3 km and 13 km. In this paper we will review a summary of the results from our flights, discuss the errors that limit the precision and accuracy of the measurement and identify possible areas of improvement.

Methane↗

Design and Performance of a Multi-mode Photon-counting Receiver for the NASA O2O Mission

The NASA Orion O2O mission was designed and tested to support high-rate bi-directional optical communications between one of multiple ground sites and a crewed capsule during a 10-day mission. This paper focuses on the design and performance of the receiver that will be based at the NASA White Sands Complex, New Mexico, USA. The main receiver components consist of two 40-cm apertures, each coupled to a specialty multi-mode optical fiber; each fiber coupled to a custom array of superconducting nanowire single-photon detectors; a high-speed, high-channel-count time-to-digital converter; and custom digitizing electronics to perform deserialization, demodulation, clock recovery, and forward error correction with a powerful serially-concatenated pulse-position-modulation turbo code. We show error-free data communication performance up to the maximum required data rate of 267 Mb/s.

optical↗

Free-Free Transitions of e-H System Inside a Dense Plasma Irradiated by a Laser Field at Very Low Incident Electron Energies

The free-free transition is studied for an electron-hydrogen in the ground state at low incident energies in the presence of an external homogenous, monochromatic, and linearly polarized laser-field inside a hot dense plasma.The effect of plasma screening is considered in the Debye-Huckel approximation. The calculations are performed in the soft photon limit, assuming that the plasma frequency is much higher than the laser frequency. The incident electron is considered to be dressed by the laser field in a nonperturbative manner by choosing the Volkov solutions in both the initial and final channels. The space part of the scattering wave function for the electron is solved numerically by taking into account the electron exchange. The laser-assisted differential and total cross sections are calculated for single-photon absorption /emission and no photon exchange in the soft photon limit, the laser intensity being much less than the atomic field intensity. The calculations have been carried out for various values of Debye parameter, ranging from 0.005 to 0.12. A strong suppression is noted in the laser-assisted cross sections as compared to the field-free situation. A significant difference is noted for the singlet and triplet cross sections. The suppression is much more in the triplet states.

Bhatia, A. K.↗

Quantum synchrotron spectra from semirelativistic electrons in teragauss magnetic fields

Synchrotron spectra are calculated from quantum electrodynamic transition rates for thermal and power-law electron distributions. It is shown that quantum effects appear in thermal spectra when the photon energy is greater than the electron temperature, and in power-law spectra when the electron energy in units of the electron rest mass times the magnetic field strength in units of the critical field strength is of order unity. These spectra are compared with spectra calculated from the ultrarelativistic approximation for synchrotron emission. It is found that the approximation for the power-law spectra is good, and the approximation for thermal spectra produces the shape of the spectrum accurately but fails to give the correct normalization. Single photon pair creation masks the quantum effects for power-law distributions, so only modifications to thermal spectra are important for gamma-ray bursts.

Brainerd, J. J.↗

Recommended Practices in Laser-Induced Fluorescence (LIF) Diagnostics for Electric Propulsion

Laser-induced fluorescence (LIF) spectroscopy uses Doppler-shifted laser photons to excite a bound electron transition in an atom or ion, with subsequent fluorescence emission detected in order to measure the local velocity distribution function (VDF) and/or particle density. Due to its non-invasive nature, high spatial resolution, and acceptable difficulty of implementation, LIF has become a favored diagnostic for electric propulsion (EP) plasmas, particularly in the study of Hall thrusters. This paper presents recommended best practices for LIF measurements in electric thrusters, drawn from over three decades of implementation heritage in the EP community. Focusing on both single-photon LIF (typically used to measure VDFs) and two-photon LIF (TALIF, typically used to determine densities), the paper covers selection of atomic transitions to target, experimental setups, and interpretation of data. A number of special topics and advanced applications are discussed, including uncertainty analysis, techniques for high-speed measurements, and applications to a variety of propellants.

plasma plume↗

Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation

A common problem in optical detection is determining the arrival time of a weak optical pulse that may comprise only one to a few photons. Currently, this problem is solved by using a photodetector to convert the optical signal to an electronic signal. The timing of the electrical signal is used to infer the timing of the optical pulse, but error is introduced by random delay between the absorption of the optical pulse and the creation of the electrical one. To eliminate this error, a time-to-space converter separates a sequence of optical pulses and sends them to different photodetectors, depending on their arrival time. The random delay, called jitter, is at least 20 picoseconds for the best detectors capable of detecting the weakest optical pulses, a single photon, and can be as great as 500 picoseconds. This limits the resolution with which the timing of the optical pulse can be measured. The time-to-space converter overcomes this limitation. Generally, the time-to-space converter imparts a time-dependent momentum shift to the incoming optical pulses, followed by an optical system that separates photons of different momenta. As an example, an electro-optic phase modulator can be used to apply longitudinal momentum changes (frequency changes) that vary in time, followed by an optical spectrometer (such as a diffraction grating), which separates photons with different momenta into different paths and directs them to impinge upon an array of photodetectors. The pulse arrival time is then inferred by measuring which photodetector receives the pulse. The use of a time-to-space converter mitigates detector jitter and improves the resolution with which the timing of an optical pulse is determined. Also, the application of the converter enables the demodulation of a pulse position modulated signal (PPM) at higher bandwidths than using previous photodetector technology. This allows the creation of a receiver for a communication system with high bandwidth and high bits/photon efficiency.

Birnbaum, Kevin↗

Development of High Quantum Efficiency UV/Blue Photocathode Epitaxial Semiconductor Heterostructures for Scintillation and Cherenkov Radiation Detection

The primary goal of this research project was to further extend the use of advanced heteroepitaxial-semiconductor crystal growth techniques such as molecular beam epitaxy (MBE) and to demonstrate significant gains in UV/blue photonic detection by designing and fabricating atomically-tailored heteroepitaxial GaAlN/GaInN photocathode device structures. This NASA Explorer technology research program has focused on the development of photocathodes for Cherenkov and scintillation radiation detection. Support from the program allowed us to enhance our MBE system to include a nitrogen plasma source and a magnetic bearing turbomolecular pump for delivery and removal of high purity atomic nitrogen during GaAlN/GaInN film growth. Under this program we have also designed, built and incorporated a cesium activation stage. In addition, a connected UHV chamber with photocathode transfer/positioner components as well as a hybrid phototube stage was designed and built to make in-situ quantum efficiency measurements without ever having to remove the photocathodes from UHV conditions. Thus we have constructed a system with the capability to couple atomically-tailored MBE-grown photocathode heterostructures with real high gain readout devices for single photon detection evaluation.

Leopold, Daniel J.↗

Radioactive transitions in the helium isoelectronic sequence

The principles of the atomic spectrum theory are used to quantitatively analyze radiation transitions in two-electron helium-like atomic systems. Quantum theoretical methods, describing absorption and emission of a single photon in a radiative transition between two stationary states of an atomic system, reproduced the energy level diagram for the low lying states of helium. Reliable values are obtained from accurate variationally determined two-electron nonrelativistic wave functions for radiative transition probabilities of 2 3p states in the helium isoelectric sequence, and for the 2 1s and 2 3s1 states of the helium sequence.

Dalgarno, A.↗

Photodissociation of nitrogen dioxide by pulsed laser light at 6943 A.

Nitrogen dioxide was photodissociated using a pulsed ruby laser at 6943 A. The energy of a single photon at this wavelength was equivalent to only 57% of the dissociation energy. The mechanism proposed to account for the results was the consecutive absorption of two photons, the first resulting in a short-lived excited state. The second photon is then absorbed by the excited species resulting in dissociation.

Gerstmayr, J. W.↗

Imaging techniques in X-ray astronomy.

Some of the imaging problems encountered in space-borne X-ray astronomy are reviewed, along with the techniques considered for their solution. Following a discussion of X-ray focussing and X-ray image processing, the development of X-ray imaging devices is surveyed. It is shown that the imaging devices that will be used in X-ray astronomy will take advantage of developments intended for infrared and optical astronomy. The special requirements of X-ray observation - especially, single photon detection and high time resolution - rule out the use of existing devices, particularly because of readout problems.

Gursky, H.↗

Self-scanned Digicon - A digital image tube for astronomical spectroscopy

We have successfully fabricated, tested, and operated a digital image tube consisting of a magnetically focused image intensifier tube in which a self-scanned linear array of 1024 silicon photodiodes operating in the EBS mode serves as the photoelectron image detector, amplifier, and intermediate image storage device. Integral on-chip MOS shift registers driven by an external clock sequentially interrogate the photodiodes through MOS FET multiplex switch arrays. Each output frame is a sequence of 256 analog pulses on each of four video lines. Laboratory and observing tests show that the output signal is photoelectron shot noise limited over at least a range of 1-100,000 detected photoelectrons per picture element, indicating that single photon detection is achieved. High-resolution astronomical spectroscopy has been carried out in the coude spectrograph of the 2.7-m telescope at McDonald Observatory. Examples are shown.

Tull, R. G.↗

Short time transient periodicities from Cyg X-1

The temporal behavior of three new events of modulated optical emission from Cyg X1, detected in July 1975, is presented. Short time periodicities in the optical band are investigated. Single photon pulses from the photomultiplier are recorded on magnetic tape together with a very accurate 1 kHz reference frequency. During playback of the tape, the reference signal gives a 1 ms timing to a scaler interfaced with a small processor and the number of photon per millisecond is recorded on a digital tape.

Auriemma, G.↗

High-resolution imaging X-ray detector

The paper describes an X-ray detector using microchannel plates as a photocathode surface and imaging photoelectron multiplier, and a crossed wire grid as a two-dimensional position-sensitive detector. The position resolution is 10 microns. The crossed wire grid consists of 100-micron-diam wires on 200-micron centers. Position sensing is accomplished by electronic interpolation to 1/20 of the wire spacing. The quantum efficiency of the microchannel plates varies from 29% at 0.28 keV to 5% at 3 keV. This detector will provide second-of-arc X-ray imaging in the focal plane of the 342.9-cm focal length grazing-incidence telescope being prepared for the HEAO-B observatory. By addition of suitable photocathodes, it can be used for single-photon imaging light detection in the UV, visible, and near-IR-ranges. In all cases, it gives a very low dark counting rate, allows timing of individual events to 1 microsec or less, and can handle counting rates up to 10,000 per sec.

Kellogg, E.↗