Search NASA⌕ Search

SEARCH · Search NASA

Results for “small angle scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Tunable thermoplastic elastomer gels derived from controlled-distribution triblock copolymers with crystallizable endblocks

Thermoplastic elastomers (TPEs), a commercially important category of triblock copolymers, are employed alone or upon physical modification with a midblock-selective oil (to form TPE gels, TPEGs) in a broad range of contemporary technologies. While most copolymers in this class of self-networking macromolecules possess glassy polystyrene endblocks and a rubbery polydiene or polyolefin midblock, we investigate TPEGs fabricated from a novel controlled-distribution copolymer with crystallizable polyolefin endblocks and a random-copolymer midblock. According to both electron microscopy and small-angle scattering, the morphologies of these TPEGs remain largely invariant up to 40 wt% oil and then transform considerably at higher oil levels. Although reductions in endblock melting point and crystallinity measured by thermal calorimetry accompany increasing oil content, mechanical properties such as the uniaxial strain at break and fracture toughness improve in some cases by over 50% between 5 and 40 wt% oil. In fact, the strain at break can reach 2500% within this range, thereby confirming that (i) the structure–property relationships of these unique TPEGs are highly composition-tunable and (ii) these TPEGs, stabilized by crystallizable endblocks, provide an attractive alternative for ultrasoft and stretchy recyclable materials.

36 MATERIALS SCIENCE↗

Probing nonlinear velocity profiles of shear-thinning, nematic platelet dispersions in Couette flow using x-ray photon correlation spectroscopy

In this study, we report experiments employing x-ray photon correlation spectroscopy (XPCS) to characterize the velocity profiles of complex fluids in Couette flow. The approach involves modeling the XPCS correlation functions obtained with the incident x-ray beam passing tangentially through the Couette cell gap at various distances from the inner wall. We first demonstrate the technique with measurements on a dilute colloidal dispersion in the Newtonian liquid glycerol, where the expected linear velocity profiles are recovered. We then employ the technique to map the shear-rate-dependent velocity profiles of a shear-thinning dispersion of nematically ordered Gibbsite platelets. The nonlinear velocity profiles of the Gibbsite dispersion include a narrow slip region adjacent to the outer wall and a band with a small velocity gradient in the interior of the gap that evolves into a region increasingly resembling plug flow with increasing shear rate. Variations in the velocity profile along the vorticity direction indicate an instability in the interface between this region of small velocity gradient and a region of high velocity gradient near the inner wall. The analysis of the small-angle scattering patterns provides information about the spatial and temporal variations in the nematic order of the Gibbsite dispersion and their coupling to the velocity profile. Additional potential applications of this XPCS-based technique and comparisons with established methods for characterizing velocity profiles are discussed.

42 ENGINEERING↗

Laboratory tests of CO2 laser collective Thomson scattering for measurements of ion temperature in the divertor

Collective Thomson scattering (CTS) is a diagnostic method that measures the ion velocity distribution of a plasma. CO2 laser CTS measurements are challenging because of the inherently small Doppler broadening and scattering signals that are difficult to detect. We implemented a heterodyne detection scheme to measure spectrum changes of less than a GHz. To maximize the collected light at small scattering angles, we designed a unique light collection approach consisting of a customized conical-shaped (axicon) lens with a hole in the center. The axicon lens is used to collect the scattered light emitted within an annular cross-section from the scattering volume while the probe beam is passed through the hole at the center of the lens. The performance of the heterodyne detection scheme and annular collection approach was demonstrated using a Transverse Excited Atmospheric pressure CO2 laser with a pulse energy of 160 mJ at λ = 10.59 µm.

Instruments & Instrumentation↗

A discretized representation for Monte Carlo simulation of deformed semiflexible chains

In this study, we present a novel orientation discretization approach based on the rhombic triacontahedron for Monte Carlo simulations of semiflexible polymer chains, aiming at enhancing structural analysis through rheo-small-angle scattering (rheo-SAS). Our approach provides a more accurate representation of the geometric features of semiflexible chains under deformation, surpassing the capabilities of traditional lattice structures. Validation against the Kratky–Porod chain system demonstrated superior consistency, underscoring its potential to significantly improve the precision of uncovering geometric details from rheo-SAS data. Further, this approach opens new avenues for investigating the conformations of semiflexible polymers and mechanically induced phase transitions in more complex polymer structures, offering deeper insights into their behavior under various conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

When x-rays alter the course of your experiments

The continuing increase in the brilliance of synchrotron radiation beamlines allows for many new and exciting experiments that were impossible before the present generation of synchrotron radiation sources came on line. However, the exposure to such intense beams also tests the limits of what samples can endure. Whilst the effects of radiation induced damage in a static experiment often can easily be recognized by changes in the diffraction or spectroscopy curves, the influence of radiation on chemical or physical processes, where one expects curves to change, is less often recognized and can be misinterpreted as a 'real' result instead of as a 'radiation influenced result'. This is especially a concern in time-resolved materials science experiments using techniques as powder diffraction, small angle scattering and x-ray absorption spectroscopy. In this work, the effects of radiation (5–50 keV) on some time-resolved processes in different types of materials and in different physical states are discussed. We show that such effects are not limited to soft matter and biology but rather can be found across the whole spectrum of materials research, over a large range of radiation doses and is not limited to very high brilliance beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying electron cyclotron power deposition broadening in DIII-D and the potential consequences for the ITER EC system

Abstract The injection of electron cyclotron (EC) waves fulfills a number of important tasks in nuclear fusion devices for which detailed knowledge of the spatial power deposition profile is critical. This deposition profile is commonly determined using forward models such as beam or ray tracing. Recent numerical and experimental studies have shown that small-angle scattering of the EC beam as it passes through the turbulent plasma edge can cause significant broadening of the effective deposition profile, leading to considerable underestimation of the deposition width by forward methods. However, traditional inverse methods to determine the deposition profile from measurements overestimate the deposition profile width due to transport broadening. In this work, we implement three novel methods to resolve the EC power deposition profile from measurements that counteract transport broadening by simultaneously resolving transport and power deposition. We validate their assumptions and compare the results from these methods to the traditional break-in-slope method as well as to the TORAY ray-tracing code in a set of DIII-D discharges spanning five different confinement modes. We show that the four different inverse methods, novel and established, paint a consistent picture of deposition broadening. Specifically, we show that the measured power deposition profile is between 1.6 and 3.6 times wider than the TORAY profiles. Moreover, we show the considerable consequences that this level of broadening can have for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bayesian inference of nuclear-matter density from proton scattering

Background: Proton elastic scattering at intermediate energy is widely employed as a tool for determining the matter radius of atomic nuclei. Here, the sensitivity of the approach relies on high-resolution measurements at small scattering angles and low-momentum transfer. Under these conditions, the Glauber multiple scattering theory accurately describes the proton-nucleus elastic cross section. Purpose: Investigate the sensitivity of the Glauber multiple scattering theory to uncertainties associated with input parameters such as the nuclear-matter density distribution and nucleon-nucleon data. Method: A joint Bayesian inference was performed using 12 angular distributions of elastic scattering at different energies on 58 Ni, 90 Zr, and 208 Pb targets. A Metropolis-Hastings algorithm was implemented to make an uncertainty quantification analysis for the input parameters used in the Glauber multiple scattering theory. Results: The experimental cross sections were fitted simultaneously using a joint Bayesian inference approach. Posterior probability density distributions of 42 input parameters were obtained from the analysis. A moderate correlation between the nuclear density parameters and the nucleon-nucleon cross sections was found. This correlation impacts the extraction of the nuclear-matter radius. Conclusions: The present analysis provided a consistent method for extracting the nuclear-matter density distribution of 58 Ni, 90 Zr, and 208 Pb from data across different incident energies. Due to the correlation of the nucleon-nucleon cross sections with the other input parameters, a constrained Bayesian inference using free nucleon-nucleon cross section data was performed. The nuclear-matter radii obtained from the analysis are in good agreement with multiple results reported in the literature.

190 ≤ A ≤ 219↗

Experimental evidence for the two-path description of neutron spin echo

Here, we describe an experiment that strongly supports a two-path interferometric model in which the spin-up and spin-down components of each neutron propagate coherently along spatially separated parallel paths in a typical neutron spin-echo small-angle scattering (SESANS) experiment. Specifically, we show that the usual semi-classical, single-path treatment of Larmor precession of a polarized neutron in an external magnetic field predicts a damping as a function of the spin-echo length of the SESANS signal obtained with a periodic phase grating when the transverse width of the neutron wave packet is finite. However, no such damping is observed experimentally, implying either that the Larmor model is incorrect or that the transverse extent of the wave packet is very large. In contrast, we demonstrate theoretically that a quantum-mechanical interferometric model in which the two mode-entangled (i.e., intraparticle entangled) spin states of a single neutron are separated in space when they interact with the grating accurately predicts the measured SESANS signal, which is independent of the wave packet width.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray Thomson scattering spectra from density functional theory molecular dynamics simulations based on a modified Chihara formula

Here, we study ab initio approaches for calculating x-ray Thomson scattering spectra from density functional theory molecular dynamics simulations based on a modified Chihara formula that expresses the inelastic contribution in terms of the dielectric function. We study the electronic dynamic structure factor computed from the Mermin dielectric function using an ab initio electron-ion collision frequency in comparison to computations using a linear-response time-dependent density functional theory (LR-TDDFT) framework for hydrogen and beryllium and investigate the dispersion of free-free and bound-free contributions to the scattering signal. A separate treatment of these contributions, where only the free-free part follows the Mermin dispersion, shows good agreement with LR-TDDFT results for ambient-density beryllium, but breaks down for highly compressed matter where the bound states become pressure ionized. LR-TDDFT is used to reanalyze x-ray Thomson scattering experiments on beryllium demonstrating strong deviations from the plasma conditions inferred with traditional analytic models at small scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opportunities for imaging light nuclei with a second interaction region at the Electron-Ion Collider

The upcoming Electron-Ion Collider (EIC) will address several outstanding puzzles in modern nuclear physics. Key questions—such as the partonic structure of nucleons and nuclei and the origin of their mass and spin—can be explored through high-energy electron-proton and electron-nucleus collisions. Here, to maximize its scientific reach, the EIC community has advocated for the addition of a second interaction region equipped with a detector complementary to the EIC general purpose collider detector, ePIC. The preconceptual design of this interaction region aims to provide a different configuration from the first interaction region, which enhances forward acceptance at very small scattering angles (𝜃 ∼0 mrad). This machine configuration would significantly benefit exclusive, tagging, and diffractive physics programs, complementing those of the ePIC experiment. In particular, accessing coherent diffractive processes on light nuclei by tagging of the full, intact nucleus is essential for mapping their spatial parton distributions. In this work, we present an exploratory study of the detection capabilities for light nuclei at a second EIC interaction region, with a detailed discussion of the accessible kinematic phase space and its implications for imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION↗

Mechanism of structural colors in binary mixtures of nanoparticle-based supraballs

Inspired by structural colors in avian species, various synthetic strategies have been developed to produce noniridescent, saturated colors using nanoparticle assemblies. Nanoparticle mixtures varying in particle chemistry and size have additional emergent properties that affect the color produced. For complex multicomponent systems, understanding the assembled structure and a robust optical modeling tool can empower scientists to identify structure-color relationships and fabricate designer materials with tailored color. Here, we demonstrate how we can reconstruct the assembled structure from small-angle scattering measurements using the computational reverse-engineering analysis for scattering experiments method and use the reconstructed structure in finite-difference time-domain calculations to predict color. We successfully, quantitatively predict experimentally observed color in mixtures containing strongly absorbing nanoparticles and demonstrate the influence of a single layer of segregated nanoparticles on color produced. The versatile computational approach that we present is useful for engineering synthetic materials with desired colors without laborious trial-and-error experiments.

36 MATERIALS SCIENCE↗

sas-temper

Modeling remains a considerable challenge for practitioners of SAXS and SANS because the materials being studied are not highly ordered, the length scales being studied are large, and the information content of the data is low. Data analysis is both challenging and time consuming. Novices often rely on the assistance of an expert, such as the instrument scientist who supported them at the facility where the experiment was performed, to analyze their data. The high flux provided by modern facilities makes it possible to study dozens of samples or sample conditions during a single trip. Ultimately, the high throughput of modern instruments limits access to instrument scientists. A bottleneck in the research effort results that reduces facility productivity. Sas-temper seeks to address this problem, as well as the intrinsic difficulties of being confident in non-linear least squared fitting of data, by providing tools that automate much of the manual process of initial data fitting and refinement, as well as by providing tools for characterizing the nature of the parameter space that fits the measured data. The tools provided by sas-temper help small-angle scattering practitioners transition data into results.

Heller, William [Oak Ridge National Lab. (ORNL), O↗

GSAS-II (GENERAL STRUCTURE AND ALAYSIS SYSTEM-II)

GSAS-II is a comprehensive data analysis and simulation software package for determining atomistic structures from single-crystal and powder diffraction data. X-ray, neutron and electron data may be used. Constant-wavelength, time-of-flight and pink-beam sources may be employed and analyses may combine different types of data. The package is oriented towards materials characterization problems, but protein crystallography, pair-distribution function analysis, small-angle scattering and reflectometry analysis are all included. GSAS-II provides tools for indexing and solving structures from powder diffraction data, in addition to structure, data and results visualization tools

TOBY, BRIANH↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EQ-SANS Detector Distance Check with Laser Alignment Method

In Small-Angle Scattering experiments, accurate distance information between sample and the detector is important. During the winter outage, January 2021, positions of detector, especially along the beam direction, were measured with the laser alignment tool to confirm values regularly deduced from silver behenate measurements. The results show that the current detector-z position of the EQ-SANS is accurate at all typically used detector positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗