Search NASA⌕ Search

SEARCH · Search NASA

Results for “small lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Results of a Long-Term Demonstration of an Optical Multi-Gas Monitor on ISS

Previously at SAMAP we reported on the development of tunable diode laser spectroscopy (TDLS) based instruments for measuring small gas molecules in real time. TDLS technology has matured rapidly over the last 5 years as a result of advances in low power diode lasers as well as better detection schemes. In collaboration with two small businesses Vista Photonics, Inc. and Nanoracks LLC, NASA developed a 4 gas TDLS based monitor for an experimental demonstration of the technology on the International Space Station (ISS). Vista invented and constructed the core TDLS sensor. Nanoracks designed and built the enclosure, and certified the integrated monitor as a payload. The device, which measures oxygen, carbon dioxide, ammonia and water vapor, is called the Multi-Gas Monitor (MGM). MGM measures the 4 gases every few seconds and records a 30 second moving average of the concentrations. The relatively small unit draws only 2.5W. MGM was calibrated at NASA-Johnson Space Center in July 2013 and launched to ISS on a Soyuz vehicle in November 2013. Installation and activation of MGM occurred in February 2014, and the unit has been operating nearly continuously ever since in the Japanese Experiment Module. Data is downlinked from ISS about once per week. Oxygen and carbon dioxide data is compared with that from the central Major Constituents Analyzer. Water vapor data is compared with dew point measurements made by sensors in the Columbus module. The ammonia channel was tested by the crew using a commercial ammonia inhalant. MGM is remarkably stable to date. Results of 18 months of operation are presented and future applications including combustion product monitoring are discussed.

Mudgett, Paul↗

Detonation of insensitive high explosives by a Q-switched ruby laser.

Immediate longitudinal detonations have been observed in confined small-diameter columns of PETN, RDX, and tetryl by using a focused Q-switched ruby laser. The energy ranged from 0.8 to 4.0 J in a pulse width of 25 nsec. A 1000-A-thick aluminum film deposited on a glass window was used to generate a shock wave at the window-explosive interface when irradiated by the laser. In some cases, steady-state detonations were reached in less than .5 microsec with less than 10% variation in the detonation velocity.

Yang, L. C.↗

Experimental Study of Noise Shielding by a NACA 0012 Airfoil

The effects of sound source location, Mach number and angle of attack on the shielding of a laser-induced sound source by a NACA 0012 airfoil are examined. The sound source is a small plasma generated by a high energy, laser beam focused to a point. In-flow microphone measurements are acquired in the midspan plane of the airfoil over a broad range of streamwise stations, and shielding levels are calculated over different frequency ranges from the measurements acquired with and without the airfoil installed. Shielding levels are shown to increase as the source is positioned closer to the mid-chord of the airfoil, and to significantly decrease with increasing flow Mach number, except when the source is positioned near the leading edge of the airfoil. Both with and without flow, changes in angle of attack are associated with a corresponding shift of the shadow region. Finally, the effects of multipath signals, observer distance and signal scatter on the measured shielding levels are discussed.

Hutcheson, Florence V.↗

1047 nm laser diode master oscillator Nd:YLF power amplifier laser system

A master oscillator power amplifier (MOPA) laser transmitter system at 1047 nm wavelength using a semiconductor laser diode and a diode pumped solid state (Nd:YLF) laser (DPSSL) amplifier is described. A small signal gain of 23 dB, a near diffraction limited beam, 1 Gbit/s modulation rates and greater than 0.6 W average power are achieved. This MOPA laser has the advantage of amplifying the modulation signal from the laser diode master oscillator (MO) with no signal degradation.

Yu, A. W.↗

Electro-optic Lightning Detector

The design, alignment, calibration, and field deployment of a solid-state lightning detector is described. The primary sensing component of the detector is a potassium dihydrogen phosphate (KDP) electro-optic crystal that is attached in series to a flat plate aluminum antenna; the antenna is exposed to the ambient thundercloud electric field. A semiconductor laser diode (lambda = 685 nm), polarizing optics, and the crystal are arranged in a Pockels cell configuration. Lightning-caused electric field changes are related to small changes in the transmission of laser light through the optical cell. Several hundred lightning electric field change excursions were recorded during five thunderstorms that occurred in the summer of 1998 at the NASA Marshall Space Flight Center (MSFC) in northern Alabama.

Koshak, William J.↗

Electro-Optic Lighting Detector

The design, alignment, calibration, and field deployment of a solid-state lightning detector is described. The primary sensing component of the detector is a potassium dihydrogen phosphate electro-optic crystal that is attached in series to a flat-plate aluminum antenna; the antenna is exposed to the ambient thundercloud electric field. A semiconductor laser diode (lambda = 685 nm), polarizing optics, and the crystal are arranged in a Pockels cell configuration. Lightning-caused electric field changes are related to small changes in the transmission of laser light through the optical cell. Several hundred lightning electric field change excursions were recorded during five thunderstorms that occurred in the summer of 1998 at the NASA Marshall Space Flight Center in northern Alabama.

Koshak, William J.↗

On-Orbit Cross Calibration Between the Osiris-Rex Orbiting Laser Altimeter and Navigation Camera

Accurate shape models of small bodies provide both science value and resources for precision relative navigation. One instrument commonly used for generating shape models is the laser altimeter. Laser altimeters require accurate intrinsic and extrinsic calibration knowledge to produce accurate shape models. Here, we describe a method used for updating the intrinsic and extrinsic calibration parameters of the laser altimeter onboard the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) spacecraft, OLA (OSIRISREx Laser Altimeter). We perform the calibration update by comparing the OLA scans with monocular camera images of the asteroid surface captured by the primary navigation camera.

Andrew J. Liounis↗

Electro-Optic Lightning Detector

The design, alignment, calibration, and field deployment of a solid-state lightning detector is described. The primary sensing component of the detector is a potassium dihydrogen phosphate (KDP) electro-optic crystal that is attached in series to a flat plate aluminum antenna; the antenna is exposed to the ambient thundercloud electric field. A semiconductor laser diode (lambda = 685 nm), polarizing optics, and the crystal are arranged in a Pockels cell configuration. Lightning-caused electric field changes are then related to small changes in the transmission of laser light through the optical cell. Several hundred lightning electric field change excursions were recorded during 4 thunderstorms that occurred in the summer of 1998 at the NASA Marshall Space Flight Center (MSFC) in Northern Alabama.

Koshak, Willliam↗

Laser-Guided Space Interferometer

The mirrors of astronomical interferometers need to be aligned within a fraction of a wavelength relative to one another. This would be especially challenging for optical instruments with mirrors separated by hundreds of meters flying in Earth’s orbit. However, in this work, we show that this alignment can be achieved by means of: (i) flying the mirror cluster in a particular orbital configuration; (ii) closing a coarse positioning loop using GNSS (Global Navigation Satellite System); and (iii) closing a fine wavefront-control loop using light from a laser guide star. The orbital configuration is designed to keep the mirrors passively pointing at the target star (up to a small orbital perturbation) while the interferometer cluster is orbiting and changing its baseline. The laser guide star would be flying in the same orbit but in the opposite direction. In medium- or high-Earth orbit, the interferometer would be able to observe a star for several hours per orbit. In this work, we analyzed the performance of an optical space interferometer consisting of nine 20 cm mirrors mounted on CubeSats and flying 3 km apart (together with a combiner and a laser guide star small satellite). This configuration supports a resolution of 0.04 milliarcseconds - an order of magnitude better than current ground-based interferometers. We estimate the performance of this system imaging stellar surfaces assuming perfect wavefront estimation and control.

Leonid Pogorelyuk↗

Portable aerosol-particle counter

Device makes real-time, precise measurements of aerosols of small particle size. Measurement combines laser velocimetry and light scattering. Technique offers advantages over currently practiced techniques: by measuring aerosol size in real-time, measuring size precisely, and having high sensitivity in size range of greatest biological concern.

Weber, F. N., Jr.↗

Surface measuring technique

Measurement of the surface contour of a large electrostatically formed concave reflector using a modified Foucault or knife edge test is described. The curve of the actual electrostatically formed reflector surface is compared to a curve representing a reference sphere. Measurements of surface slope and deviation are calculated every 15 cm along the reflector's horizontal and vertical diameters. Characterization of surface roughness on a small scale compared to the laser spot size at the reflector are obtained from the increased laser spot size at a distant projection screen.

Spiers, R. B., Jr.↗

Particle field holography data reduction by Fourier transform analysis

The size distribution of a particle field hologram is obtained with a Fourier transformation of the Fraunhofer diffraction pattern of the reconstructed hologram. Off-axis absorption holograms of particle fields with known characteristics were obtained and analyzed with a commercially available instrument. The mean particle size of the reconstructed hologram was measured with an error of + or - 5 percent, while the distribution broadening was estimated within + or - 15 percent. Small sections of a pulsed laser hologram of a synthetic fuel spray were analyzed with this method thus yielding a spatially resolved size distribution. The method yields fast and accurate automated analysis of particle field holograms.

Hess, Cecil F.↗

The flight demonstration program and selection process

The Orbital Refueling System (ORS); force torque sensor; Plasma Motor/Generator (PMG) proof of function; voice controlled system; infrared intercommunications; superfluid helium on orbit transfer; laser docking sensor; and the Small Expendable Deployment System (SEDS) are summarized.

Levin, G. M.↗

A planar Mie scattering technique for visualizing supersonic mixing flows

A planar Mie scattering technique is described which allows for the direct visualization of fluid mixing in supersonic flows. The mixed fluid is visualized by laser light sheet scattering from small alcohol droplets which condense as a result of the mixing of a vapor laden subsonic stream with a cold supersonic stream. Issues related to the formation, growth and size of the droplets are addressed. The technique reveals details of the turbulent structure which are masked by the spatial integration of schlieren and shadowgraph methods. Comparative visualizations using the vapor screen method to uniformly mark the high-speed fluid are also shown.

Clemens, N. T.↗

The Use of Spontaneous Raman Scattering for Hydrogen Leak Detection

A fiber optic probe has been built and demonstrated that utilizes back scattered spontaneous Raman spectroscopy to detect and identify gaseous species. The small probe, coupled to the laser and data acquisition equipment with optical fibers, has applications in gaseous leak detection and process monitoring. The probe design and data acquisition system are described. Raman scattering theory has been reviewed and the results of intensity calculations of hydrogen and nitrogen Raman scattering are given. Because the device is in its developmental stage, only preliminary experimental results are presented here. Intensity scans across the rotational-vibrational Raman lines of nitrogen and hydrogen are presented. Nitrogen at a partial pressure of 0.077 MPa was detected. Hydrogen at a partial pressure of 2 kPa approached the lower limit of detectability with the present apparatus. Potential instrument improvements that would allow more sensitive and rapid hydrogen detection are identified.

Degroot, Wim A.↗

Unsteady spot heating of a drop in a microgravity environment

The unsteady localized spot heating of a liquid drop under zero-g conditions is examined theoretically. This pertains to space experiments to measure thermal properties of materials and the purpose here is to predict the thermal behavior of such systems. Spot heating can be achieved by a laser beam focused on a small region of the drop surface. The present theoretical model deals with situations of weak Marangoni flows, whereby the thermal transport is conduction dominated. The heat flow in the drop is treated as unsteady while the surrounding gaseous region is considered to be quasisteady. The ensuing thermally driven flow is analyzed in the Stokes regime.

Sadhal, Satwindar Singh↗