Search NASA⌕ Search

SEARCH · Search NASA

Results for “smart enabled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Fleet-wide Electrification Impacts Assessment for the Valley Transportation Authority

This report explores the long-term electrification opportunities for the Valley Transit Authority’s (VTA) transit bus fleet. The potential for transit bus electrification at VTA as well as the economic impacts of partial and complete electrification are explored. We use the Revenue Operation and Device Optimization model to determine the optimal charging, operation and lowest capital and operating cost solution to achieve different levels of electrification to meet their existing routes. This study finds that, relying on only depot charging, around 70% of the daily trips by VTA’s transit bus fleet can be replaced with battery electric buses (BEBs) today. The benefits and drawbacks of five methods for improving the electrification potential beyond that achievable with only depot charging are discussed including (1) increase charger power, (2) purchase of larger vehicle batteries, (3) en-route charging, (4) purchasing additional buses and swapping them to enable the existing routes/blocks1 to be met, and (5) route/block redesign. A strategy is developed to enable full fleet electrification by increasing charger power or allowing intraday charging as a proxy for the options mentioned above. This method allows us to develop an understanding of the impacts and trade-offs of full fleet electrification. Two charging strategies are examined. Immediate charging, when the bus is charged as soon as it arrives at a depot or en-route charging station, and smart charging, which uses a controller to determine the best times to charge to achieve the lowest charging cost, while maintaining the same trip schedules. Smart charging is effective at reducing the peak power consumption, which can be reduced by between 31% and 65% compared to immediate charging. This translates directly to lower electricity demand charges and lower costs for possible distribution system upgrades. The total lifetime net present value (NPV) costs for different scenarios are presented in Figure ES-1. Scenarios are separated into three sections. The first stacked bar on the left is the base case (business-as-usual) where all buses are diesel hybrids, the next four bars include partial and full fleet electrification utilizing only immediate charging, and the last four bars include partial and full fleet electrification utilizing smart charging. The results show that smart charging scenarios are within ±4% of the lifetime NPV cost of the diesel-hybrid only (business-as-usual) scenario. The scenarios with full fleet electrification (i.e., including intraday charging) are 4% lower cost and those with partial fleet electrification (i.e., without intraday charging) are 2%–3% higher. However, it is important to note that the intraday charging scenarios do not include any additional costs for the equipment necessary to achieve intraday charging (e.g., additional chargers, larger batteries, new route design). Additionally, it is worth noting that the Low Carbon Fuel Standard (LCFS) credit received for implementing electric buses is essential to achieving these results.

33 ADVANCED PROPULSION SYSTEMS↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications: Preprint

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

900 MHz LTE network↗

Creating a Prototype Web Application for Spacecraft Real-Time Data Visualization on Mobile Devices

Mobile devices (smart phones, tablets) have become commonplace among almost all sectors of the workforce, especially in the technical and scientific communities. These devices provide individuals the ability to be constantly connected to any area of interest they may have, whenever and wherever they are located. The Huntsville Operations Support Center (HOSC) is attempting to take advantage of this constant connectivity to extend the data visualization component of the Payload Operations and Integration Center (POIC) to a person's mobile device. POIC users currently have a rather unique capability to create custom user interfaces in order to view International Space Station (ISS) payload health and status telemetry. These displays are used at various console positions within the POIC. The Software Engineering team has created a Mobile Display capability that will allow authenticated users to view the same displays created for the console positions on the mobile device of their choice. Utilizing modern technologies including ASP.net, JavaScript, and HTML5, we have created a web application that renders the user's displays in any modern desktop or mobile web browser, regardless of the operating system on the device. Additionally, the application is device aware which enables it to render its configuration and selection menus with themes that correspond to the particular device. The Mobile Display application uses a communication mechanism known as signalR to push updates to the web client. This communication mechanism automatically detects the best communication protocol between the client and server and also manages disconnections and reconnections of the client to the server. One benefit of this application is that the user can monitor important telemetry even while away from their console position. If expanded to the scientific community, this application would allow a scientist to view a snapshot of the state of their particular experiment at any time or place. Because the web application renders the displays that can currently be created with the POIC ground system, the user can tailor their displays for a particular device using tools that they are already trained to use.

Lang, Jeremy S.↗

Experimental Test Bed to Enable Realistic Evaluations for Direct Transfer Trip Relaying via Private Wireless LTE Communications

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. This paper demonstrates an experimental test bed to enable the realistic evaluation of communications system characteristics for direct transfer trip (DTT) relaying of a photovoltaic inverter system using a private 900-MHz spectrum wireless LTE network. Private LTE network communications can be deployed to many remote DERs and other grid-edge devices to prevent costly infrastructure upgrades across distribution systems. In addition, this paper provides a framework for evaluating the impact of signal strength and network traffic in communications systems. The results shown develop a better understanding of the best practices for using LTE communications systems across multiple utility applications, such as protective relaying, voltage regulation, and supervisory control and data acquisition system messages.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Custom Controls for Improved Demand Response from Heat Pump Water Heaters

As part of a Grid Modernization Laboratory Consortium (GMLC) project looking at defining grid services for a range of devices, NREL used a custom controller to investigate the ability of a HPWH to provide load add and load shed in hybrid and electric resistance mode using standard set point control. Based on those results, changes were made to the controls to increase the amount of grid services delivered, especially in the load-add case, and speed up the recovery from those events. The custom controls also include less common methods, such as duty cycling of the heat pump or elements. The improved controls led to an increase the amount of demand response that could be provided and enabled faster recovery. Results from the laboratory experiments will be presented, along with details about the custom controls that were implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Center for Efficiency in Sustainable Energy Systems

The main goal of the Center for Efficiency in Sustainable Energy Systems is to produce a methodology that evaluates a variety of energy systems. Task I. Improved Energy Efficiency for Industrial Processes: This task, completed in partnership with area manufacturers, analyzes the operation of complex manufacturing facilities to provide flexibilities that allow them to improve active-mode power efficiency, lower standby-mode power consumption, and use low cost energy resources to control energy costs in meeting their economic incentives; (2) Identify devices for the efficient transformation of instantaneous or continuous power to different devices and sections of industrial plants; and (3) use these manufacturing sites to demonstrate and validate general principles of power management. Task II. Analysis of a solid oxide fuel cell operating on landfill gas: This task consists of: (1) analysis of a typical landfill gas; (2) establishment of a comprehensive design of the fuel cell system (including the SOFC stack and BOP), including durability analysis; (3) development of suitable reforming methods and catalysts that are tailored to the specific SOFC system concept; and (4) SOFC stack fabrication with testing to demonstrate the salient operational characteristics of the stack, including an analysis of the overall energy conversion efficiency of the system. Task III. Demonstration of an urban wind turbine system: This task consists of (1) design and construction of two side-by-side wind turbine systems on the YSU campus, integrated through power control systems with grid power; (2) preliminary testing of aerodynamic control effectors (provided by a small business partner) to demonstrate improved power control, and evaluation of the system performance, including economic estimates of viability in an urban environment; and (3) computational analysis of the wind turbine system as an enabling activity for development of smart rotor blades that contain integrated sensor/actuator/controller modules to enhance energy capture and reduce aerodynamic loading and noise by way of virtual aerodynamic shaping. Accomplishments: Task I. Improved Energy Efficiency for Industrial Processes: We organized an energy management training session held on February 22, 2011, which was advertised through a regional manufacturing association to provide wide-ranging notification. Over two dozen companies were represented a the seminar, ranging from heavy manufacturing businesses with $5,000,000 per year energy expenses, to small, light manufacturing facilities. Task 2. Landfill Fuel Cell Power Generation Solid Oxide Fuel Cells (SOFCs) were constructed and evaluated as a means of obtaining electrical energy from landfill gas. Analysis of landfill gas. Attempts at collecting gas samples at the landfill and evaluating them on campus were still unsuccessful. Even a Teflon® sample bag would lose its H2S content. Evaluation of Gas Clean-up We consider this a confirmation of the CO2 effect on the solubility of H2S in water making much less sulfide available for the photocatalyst. It also means that another method should be employed to clean up landfill gas. Nonetheless, composition of impurities in landfill gas was reduced sufficiently to allow successful operation of the test fuel cell. Comparison to a PEM fuel cell system. If a PEMFC were to be operated with landfill gas as the fuel, the gas would have to be treated for sulfur removal, and then processed in a reformer large enough to drive the equilibrium far toward the products, so that negligible CO would flow into the fuel cell. Analysis of a fuel cell running on landfill gas. Using a Gow-Mac gas chromatograph with a thermal conductivity detector, unambiguous determination of CO can be made, at least as a primary constituent Task 3: Task 3 Plasma Controlled Turbine Blades Wind Turbine Selection. After carefully reviewing the various model available in the market the team selected the ARE 110 (2.5kW). The ARE 110 provides a very long life with little maintenance due to their relatively low rotational speeds (low RPM). The turbines large swept area (10.2ms2/110sq.ft), high-efficiency blades, purpose built alternator, and optimized power electronics ensure maximum energy capture from a wide range of wind speeds. Two wind turbines were installed side-by-side at the Melnick Hall site to compare their performance. Evaluate and Optimize Aerodynamically Enhanced Turbine Blades Due to delays in the installation of the wind turbines, no actual data was obtained within the contract period. At this time, the turbines are installed and operational at YSU with standard blades. We are in contact with Orbital Research and in discussion as to how best the required data can be obtained.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform

The goal of the Scalable Thin Light-Emitting Diode (LED) Light Sheet Platform project is to derisk the manufacturing scalability for a high chip count heterogeneous smart lighting platform, with the potential to enable significant energy savings through dynamic directional light control and custom. Specifically, the project derisks the scalability of a disruptive new computer controlled microassembly fabrication process SRI International is developing, to address fundamental cost barriers to mass production of high chip count systems. This is key for enabling mass adoption and thus maximum societal energy savings impact. The LED light sheet technology is a smart illumination platform that can be applied to lighting, signage, and display. It has features and a form factor similar to bendable or conformal OLED light sheets but uses more efficient LEDs with a remote phosphor layer that is very close to the LED to deliver a luminous efficacy that exceeds 125 lumen/Watt and enable > 50% Lighting Application Efficiency (LAE) energy savings. During Budget Period 1 (BP1), all of the BP1 milestones were successfully completed: (M2.0.1) Design demonstrator details that will meet the final project goals, (M6.1.1) Show lighting output model can predict illuminance, spatial, spectral distribution for specific light-sheet designs and use case, (M3.2.1) Automated loading supports 200 chip arrays, and (M3.3.1) Finish first interconnect process run for 200 chip array. The BP1 Go/No-Go Decision Point (G/NG 1) 200 chip demonstrator sample was in the process of final assembly and test at the end of BP1 on December 31, 2023. The objective was successfully achieved on January 16, 2024, when a wired 200-chip sample underwent confirmation testing that demonstrated a 93.75% first pass electrical yield that successfully exceeded the 75% first-pass electrical yield BP1 G/NG requirement. In addition, all 93.75% of the sample devices lit up, further demonstrating the ability to assemble and transfer small LED chips without damaging their functionality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Hardware-in-the-Loop Testbed to Evaluate FLISR Implemented with OpenFMB

With the increasing complexity of the distribution smart grid architecture, algorithms such as the fault location, isolation, and service restoration (FLISR) scheme rely on robust communications that are resilient to natural and man-made adverse conditions and exhibit robustness. Existing communications infrastructure for information exchange are centralized at the distribution management system, with very little autonomy or intelligence at the grid-edge. As a first step towards achieving grid-edge self-healing, this paper aims to bridge this shortcoming by implementing a centrally coordinated rules-based FLISR scheme and integrating it with Open Field Message Bus (OpenFMB), which is a flexible publish-subscribe architecture with the potential to enable point-to-multipoint communications and is more robust and resilient to natural and man-made adverse conditions. A proof of concept is developed to validate the centrally coordinated FLISR and OpenFMB mounted on an SEL-3360 computer that interacts with a simple feeder network of five SEL-651R relays, an SEL-3530 RTAC, and a hardware-in-the-loop testbed. Results demonstrate the efficacy of this approach in enabling direct, low-latency information exchange. OpenFMB's publish-subscribe data model also opens new ways to enable grid-edge interoperability among devices of different vendors interacting with different protocols.

Sundararajan, Aditya↗

Mapping Rare Earths and Toxics in E-Waste via Hyperspectral Imaging and Machine Learning

Electronic waste (e-waste) presents a mounting challenge to environmental sustainability due to its complex composition, which includes high-value rare earth elements, hazardous organic compounds, and non-recyclable plastics. Accurate and scalable material classification is essential for enabling efficient resource recovery and safe recycling practices. This study introduces a confidence-aware classification pipeline that combines mid-infrared hyperspectral imaging (HSI), spectral angle mapping (SAM), and iterative machine learning to perform pixel-level material identification across e-waste devices. A curated spectral library encompassing artificial materials (e.g., plastic iron oxide, galvanized metals), minerals (e.g., allanite, hematite), and organic compounds (e.g., benzanthracene, toluene) was used to generate pseudo-labels, each assigned a confidence score based on SAM-derived spectral similarity. High-confidence samples from seven consumer electronics—digital cameras, keyboards, laptop fans, modems, motherboards, TV remotes, and speakers—were iteratively expanded and classified using models such as Support Vector Machine (SVM), Random Forest, Gradient Boosting Classifier, Partial Least Squares Discriminant Analysis (PLSDA) and Logistic Regression. The best-performing classifiers achieved macro F1 scores approaching 1.0. Results revealed widespread plastic content (dominated by plastic iron oxide), the presence of rare earth-bearing minerals like cerium-containing allanite, and pervasive detection of hazardous organics such as benzanthracene. Principal Component Analysis (PCA) visualizations and confusion matrices confirmed high separability and robust classification performance. This methodology enables precise, non-destructive, and scalable classification of heterogeneous e-waste streams. It supports automated, hazard-aware sorting in recycling workflows, facilitating selective recovery of critical materials and compliance with circular economy goals. The confidence-aware framework provides a foundation for real-time deployment in industrial settings, offering significant implications for smart e-recycling infrastructure and policy-driven material stewardship.

Circular economy↗

VOLTTRON-Based System for Providing Ancillary Services with Residential Building Loads

Ancillary services entail controlled modulation of building equipment to maintain a stable balance of generation and load in the power system. Ancillary services include frequency regulation and contingency reserves, whose acting time ranges from several seconds to several minutes. Many pilot studies have been implemented to use industrial loads to provide ancillary services, and some have explored services from commercial building loads or electric vehicle charging loads. Residential loads, such as space conditioning and water heating, represent a largely untapped resource for providing ancillary services. The residential building sector accounts for a significant fraction of the total electricity use in the United States. Many loads in residential buildings are flexible and could potentially be curtailed or shifted at the request of the grid. However, there are many barriers that prevent residential loads being widely used for ancillary services. One of the major technical barriers is the lack of communication capabilities between end-use devices and the grid. End-use devices need to be able to receive the automatic generation control (AGC) signal from the grid operator and supply certain types of telemetry to verify response. With the advance of consumer electronics, communication-enabled, or 'connected,' residential equipment has emerged to overcome the communication barrier. However, these end-use devices have introduced a new interoperability challenge due to the existence of numerous standards and communication protocols among different end devices. In this paper, we present a VOLTTRON-based system that overcomes these technical challenges and provides ancillary services with residential loads. VOLTTRON is an open-source control and sensing platform for building energy management, facilitating interoperability solutions for end devices. We have developed drivers to communicate and control different types of end devices through standard-based interfaces, manufacturer-provided application programming interfaces, and proprietary communication interfaces. We document the ability to manage nine appliances, using four different standards or proprietary communication methods. A hardware-in-the-loop test was performed in a laboratory environment where the loads of a laboratory home and a large number of simulated homes are controlled by an aggregator. Upon receipt of an AGC signal, the VOLTTRON home energy management system (HEMS) of the laboratory home adjusts the end-device controls based on the comfort criteria set by the end users and sends telemetry to the aggregator to verify response. The aggregator then sends the AGC signal to other simulated homes in attempts to match the utility request as closely as possible. Frequency regulation is generally considered a higher value service than other ancillary services but it is also more challenging due to the constraint of short response time. A frequency regulation use case has been implemented with the regulation signals sent every 10 seconds. Experimental results indicate that the VOLTTRON-controlled residential loads are able to be controlled with sufficient fidelity to enable an aggregator to meet frequency regulation requirements. Future work is warranted, such as understanding the impact of this type of control on equipment life, and market requirements needed to open up residential loads to ancillary service aggregators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open Circuit Resonant (SansEC) Sensor Technology for Lightning Mitigation and Damage Detection and Diagnosis for Composite Aircraft Applications

Traditional methods to protect composite aircraft from lightning strike damage rely on a conductive layer embedded on or within the surface of the aircraft composite skin. This method is effective at preventing major direct effect damage and minimizes indirect effects to aircraft systems from lightning strike attachment, but provides no additional benefit for the added parasitic weight from the conductive layer. When a known lightning strike occurs, the points of attachment and detachment on the aircraft surface are visually inspected and checked for damage by maintenance personnel to ensure continued safe flight operations. A new multi-functional lightning strike protection (LSP) method has been developed to provide aircraft lightning strike protection, damage detection and diagnosis for composite aircraft surfaces. The method incorporates a SansEC sensor array on the aircraft exterior surfaces forming a "Smart skin" surface for aircraft lightning zones certified to withstand strikes up to 100 kiloamperes peak current. SansEC sensors are open-circuit devices comprised of conductive trace spiral patterns sans (without) electrical connections. The SansEC sensor is an electromagnetic resonator having specific resonant parameters (frequency, amplitude, bandwidth & phase) which when electromagnetically coupled with a composite substrate will indicate the electrical impedance of the composite through a change in its resonant response. Any measureable shift in the resonant characteristics can be an indication of damage to the composite caused by a lightning strike or from other means. The SansEC sensor method is intended to diagnose damage for both in-situ health monitoring or ground inspections. In this paper, the theoretical mathematical framework is established for the use of open circuit sensors to perform damage detection and diagnosis on carbon fiber composites. Both computational and experimental analyses were conducted to validate this new method and system for aircraft composite damage detection and diagnosis. Experimental test results on seeded fault damage coupons and computational modeling simulation results are presented. This paper also presents the shielding effectiveness along with the lightning direct effect test results from several different SansEC LSP and baseline protected and unprotected carbon fiber reinforced polymer (CFRP) test panels struck at 40 and 100 kiloamperes following a universal common practice test procedure to enable damage comparisons between SansEC LSP configurations and common practice copper mesh LSP approaches. The SansEC test panels were mounted in a LSP test bed during the lightning test. Electrical, mechanical and thermal parameters were measured during lightning attachment and are presented with post test nondestructive inspection comparisons. The paper provides correlational results between the SansEC sensors computed electric field distribution and the location of the lightning attachment on the sensor trace and visual observations showing the SansEC sensor's affinity for dispersing the lightning attachment.

Szatkowski, George N.↗

Spinoff 2013

Topics covered include: Innovative Software Tools Measure Behavioral Alertness; Miniaturized, Portable Sensors Monitor Metabolic Health; Patient Simulators Train Emergency Caregivers; Solar Refrigerators Store Life-Saving Vaccines; Monitors Enable Medication Management in Patients' Homes; Handheld Diagnostic Device Delivers Quick Medical Readings; Experiments Result in Safer, Spin-Resistant Aircraft; Interfaces Visualize Data for Airline Safety, Efficiency; Data Mining Tools Make Flights Safer, More Efficient; NASA Standards Inform Comfortable Car Seats; Heat Shield Paves the Way for Commercial Space; Air Systems Provide Life Support to Miners; Coatings Preserve Metal, Stone, Tile, and Concrete; Robots Spur Software That Lends a Hand; Cloud-Based Data Sharing Connects Emergency Managers; Catalytic Converters Maintain Air Quality in Mines; NASA-Enhanced Water Bottles Filter Water on the Go; Brainwave Monitoring Software Improves Distracted Minds; Thermal Materials Protect Priceless, Personal Keepsakes; Home Air Purifiers Eradicate Harmful Pathogens; Thermal Materials Drive Professional Apparel Line; Radiant Barriers Save Energy in Buildings; Open Source Initiative Powers Real-Time Data Streams; Shuttle Engine Designs Revolutionize Solar Power; Procedure-Authoring Tool Improves Safety on Oil Rigs; Satellite Data Aid Monitoring of Nation's Forests; Mars Technologies Spawn Durable Wind Turbines; Programs Visualize Earth and Space for Interactive Education; Processor Units Reduce Satellite Construction Costs; Software Accelerates Computing Time for Complex Math; Simulation Tools Prevent Signal Interference on Spacecraft; Software Simplifies the Sharing of Numerical Models; Virtual Machine Language Controls Remote Devices; Micro-Accelerometers Monitor Equipment Health; Reactors Save Energy, Costs for Hydrogen Production; Cameras Monitor Spacecraft Integrity to Prevent Failures; Testing Devices Garner Data on Insulation Performance; Smart Sensors Gather Information for Machine Diagnostics; Oxygen Sensors Monitor Bioreactors and Ensure Health and Safety; Vision Algorithms Catch Defects in Screen Displays; and Deformable Mirrors Capture Exoplanet Data, Reflect Lasers.

Source record↗

The Plug-and-Play Electricity Era: Interoperability to Integrate Anything, Anywhere, Anytime

The advent of the information age continues to transform the mechanics of integrating electric power devices and systems from coordinated operations based purely on the physics of electric power engineering to an increasing blend of power with information and communications technology engineering. Integrating electric system components is not just about attaching electric power wires but requires the connection of computer-based automation systems and their associated sensing and communications equipment. The architectural impacts are significant. Well-considered and commonly held concepts, principles, and organizational structures have been emerging to address the complexity of the integrated operational challenges that drives our society to expect more flexibility in configuring the electric power system, while simultaneously achieving greater efficiency, reliability, and resilience. Architectural concepts such as modularity and composability contribute to forming structures that enable the connection of power system equipment characterized by clearly-defined interfaces that consist of physical connections and cyber connections. Overall, the result of successful integration of the components of the electric power system is interoperation; the discipline that drives the integration to be simple and reliable is the topic of interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ion Gating in Nanopore Electrode Arrays with Hierarchically Organized pH-Responsive Block Copolymer Membranes

Inspired by biological ion channels, artificial nanopore-based architectures have been developed for smart ion/molecular transport control with potential applications to iontronics and energy conversion. Advances in nanofabrication technology enable simple, versatile construction methods, and post-fabrication functionalization delivers nanochannels with unique ion transport-control attributes. Here, we characterize a pH-responsive, charge-selective dual-gating block copolymer (BCP) membrane composed of polystyrene-b-poly(4-vinylpyridine) (PS 48400 -b-P4VP 21300 ), capable of self-organizing into highly ordered nanocylindrical domains. Because the PS-b-P4VP membrane exhibits pH-dependent structural transitions, it is suitable for designing intelligent pH-gated biomimetic channels, for example, exhibiting on–off transport switching at pH values near the pK a of P4VP with excellent anion permselectivity at pH < pK a . Introducing the BCP membrane onto nanopore electrode arrays (BCP@NEAs) allows the BCP to serve as a pH-responsive gate controlling ion transfer into the NEA nanopores. Such selectively transported and confined ions are detected by using a 100 nm gap dual-ring nanoelectrode structure capable of enhancing current output by efficient redox cycling with an amplification factor >10 2 . In addition, BCP@NEAs exhibit extraordinary pH-gated ion selectivity, resulting in a 3380-fold current difference between anion and cation probes at pH 3.0. Furthermore, this hierarchically organized BCP-gated NEA system can serve as a template for the development of other stimulus-responsive ion gates, for example, those based on temperature and ligand gating, thus exploiting the intrinsic advantages of NEAs, such as enhanced sensitivity based on redox cycling, which may lead to technological applications such as engineered biosensors and iontronic devices.

36 MATERIALS SCIENCE↗

Enabling Advanced Automation in Spacecraft Operations with the Spacecraft Emergency Response System

True autonomy is the Holy Grail of spacecraft mission operations. The goal of launching a satellite and letting it manage itself throughout its useful life is a worthy one. With true autonomy, the cost of mission operations would be reduced to a negligible amount. Under full autonomy, any problems (no matter the severity or type) that may arise with the spacecraft would be handled without any human intervention via some combination of smart sensors, on-board intelligence, and/or smart automated ground system. Until the day that complete autonomy is practical and affordable to deploy, incremental steps of deploying ever-increasing levels of automation (computerization of once manual tasks) on the ground and on the spacecraft are gradually decreasing the cost of mission operations. For example, NASA's Goddard Space Flight Center (NASA-GSFC) has been flying spacecraft with low cost operations for several years. NASA-GSFC's SMEX (Small Explorer) and MIDEX (Middle Explorer) missions have effectively deployed significant amounts of automation to enable the missions to fly predominately in 'light-out' mode. Under light-out operations the ground system is run without human intervention. Various tools perform many of the tasks previously performed by the human operators. One of the major issues in reducing human staff in favor of automation is the perceived increased in risk of losing data, or even losing a spacecraft, because of anomalous conditions that may occur when there is no one in the control center. When things go wrong, missions deploying advanced automation need to be sure that anomalous conditions are detected and that key personal are notified in a timely manner so that on-call team members can react to those conditions. To ensure the health and safety of its lights-out missions, NASA-GSFC's Advanced Automation and Autonomy branch (Code 588) developed the Spacecraft Emergency Response System (SERS). The SERS is a Web-based collaborative environment that enables secure distributed fault and resource management. The SERS incorporates the use of intelligent agents, threaded discussions, workflow, database connectivity, and links to a variety of communications devices (e.g., two-way paging, PDA's, and Internet phones) via commercial gateways. When the SERS detects a problem, it notifies on-call team members, who then can remotely take any necessary actions to resolve the anomalies.The SERS goes well beyond a simple '911' system that sends out an error code to everyone with a pager. Instead, SERS' software agents send detailed data (i.e., notifications) to the most appropriate team members based on the type and severity of the anomaly and the skills of the on-call team members. The SERS also allows the team members to respond to the notifications from their wireless devices. This unique capability ensures rapid response since the team members no longer have to go to a PC or the control center for every anomalous event. Most importantly, the SERS enables safe experimentation with various techniques for increasing levels of automation, leading to robust autonomy. For the MIDEX missions at NASA GSFC, the SERS is used to provide 'human-in-the-loop' automation. During lights-out operations, as greater control is given to the MIDEX automated systems, the SERS can be configured to page remote personnel and keep them informed regarding actions taking place in the control center. Remote off-duty operators can even be given the option of enabling or inhibiting a specific automated response in near real time via their two-way pagers. The SERS facilitates insertion of new technology to increase automation, while maintaining the safety and security of mission resources. This paper will focus on SERS' overall functionality and how SERS has been designed to handle the monitoring and emergency response for missions with varying levels of automation. The paper will also convey some of the key lessons learned from SERS' deployment across of variety of missions, highlighting this incremental approach to achieving 'robust autonomy'.

Breed, Julie↗

Managing Multi-Instrument Data Streams in Secure Environments

The capture and curation of all primary instrument data is a potentially valuable source of added insight into experiments or diagnostics in laboratory experiments. The data can, when properly curated, enable analysis beyond the current practice that uses just a subset of the as-measured data. Complete curated data can also be input for machine learning and other data exploration tools. Conveniently storing and accessing instrument data requires that the instruments are connected to databases and users through a networking infrastructure. This infrastructure needs to accommodate a wide array of instruments which can range from single laboratory mounted probes for environment monitoring to computers managing multiple instruments. These resources may also include mobile devices on which researchers record instrument and experiment state related notes. These varied data sources bring with them the challenges of different communications capabilities and protocols as well as the primary data typically being produced in proprietary formats. These challenges are further compounded when the instruments need to operate in secure environments such as required in national laboratories. We will discuss the SmartLab, an ongoing effort to set up a system for instrument and simulation data curation at NASA Langley Research Center. We will outline the challenges faced in managing the data sources required for ongoing research activities and the solutions that are being considered and implemented to address those challenges.

instrument data management↗