Search NASA⌕ Search

SEARCH · Search NASA

Results for “soaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

198 records · Page 11

Approximation of Engine Casing Temperature Constraints for Casing Mounted Electronics

The performance of propulsion engine systems is sensitive to weight and volume considerations. This can severely constrain the configuration and complexity of the control system hardware. Distributed Engine Control technology is a response to these concerns by providing more flexibility in designing the control system, and by extension, more functionality leading to higher performing engine systems. Consequently, there can be a weight benefit to mounting modular electronic hardware on the engine core casing in a high temperature environment. This paper attempts to quantify the in-flight temperature constraints for engine casing mounted electronics. In addition, an attempt is made at studying heat soak back effects. The Commercial Modular Aero Propulsion System Simulation 40k (C-MAPSS40k) software is leveraged with real flight data as the inputs to the simulation. A two-dimensional (2-D) heat transfer model is integrated with the engine simulation to approximate the temperature along the length of the engine casing. This modification to the existing C-MAPSS40k software will provide tools and methodologies to develop a better understanding of the requirements for the embedded electronics hardware in future engine systems. Results of the simulations are presented and their implications on temperature constraints for engine casing mounted electronics is discussed.

Engine↗

Thermal Analysis of Propulsion Components for the Europa Clipper Mission

This presentation describes the thermal analysis and model development that occurred for selected components on the propulsion module subsystem of the Europa Clipper mission, which will fly to Jupiter's icy moon Europa and collect science data from orbit. An overview of a bipropellant system is given, as well as a description of a typical thermal propulsion design. A comparison is also provided, describing the unique Europa Clipper thermal design, which is atypical in many respects. The engine thermal model development is also discussed, including hot-firing tests with nozzle convection correlation, as well as thermal vacuum tests to measure and correlate the emissivity of critical nozzle surfaces. A description of engine firing, as well as valve soak back, is also provided, including temperature maps and results of engine cases. A summary is also provided, of lessons learned regarding thermal propulsion considerations.

propulsion module subsystem↗

Optothermal Stability of Large ULE and Zerodur Mirrors

Marshall Space Flight Center's (MSFC) X-ray and Cryogenic Test Facility (XRCF) has tested the optothermal stability of two low-CTE, large-aperture mirrors in a thermal vacuum chamber. The mirrors deformed from several causes such as: thermal gradients, thermal soaks, coefficient of thermal expansion (CTE) gradients, CTE mismatch, and stiction. This paper focuses on how the aforementioned conditions affected the surface figure of the large optics while in vacuum at temperatures ranging from 230 to 310 K (-43 to 37 ˚C). The presented data, conclusions, and taxonomy are useful for designing mirrors and support structures for telescopes. The data is particularly useful for telescopes that require extreme dimensional stability or telescopes that operate at a temperature far from ambient.

Brooks, Thomas E.↗

Frostwing Co-Operation in Aircraft Icing Research

e aerodynamic effects of Cold Soaked Fuel Frost have become increasingly significant as airworthiness authorities have been asked to allow it during aircraft take-off. The Federal Aviation Administration and the Finnish Transport Safety Agency signed a Research Agreement in aircraft icing research in 2015 and started a research co-operation in frost formation studies, computational fluid dynamics for ground de/anti-icing fluids, and de/anti-icing fluids aerodynamic characteristics. The main effort has been so far on the formation and aerodynamic effects of CSFF. To investigate the effects, a generic high-lift common research wind tunnel model and DLR-F15 airfoil, representing the wing of a modern jet aircraft, was built including a wing tank cooling system. Real frost was generated on the wing in a wind tunnel test section and the frost thickness was measured with an Elcometer gauge. Frost surface geometry was measured with laser scanning and photogrammetry. The aerodynamic effect of the frost was studied in a simulated aircraft take-off sequence, in which the speed was accelerated to a typical rotation speed and the wing model was then rotated to an angle of attack used at initial climb. Time histories of the lift coefficient were measured with a force balance. The experiments showed that depending on the ambient temperature the frost may evaporate/melt during the take-off sequence. Lift losses after rotation with CSFF contamination at ambient temperatures of 4˚ to 7˚C above freezing point were measured to be 4 to 5 % for roughness values, k/c, below 10(exp -3). For comparison, lift loss tests with typical anti-icing fluids were to roughly equal lift losses. This paper gives an overview of the performed activities.

Koivisto, Pekka↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell.Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing. During arc jet testing, the heat flux sensors embedded in the SLA-561V panels exhibited an unexpected temporary reduction in the heat flux sensor temperature and response. After review of the test results, it was determined that this unexpected response was confined to the two heat flux sensors that experienced the greatest thermal shock condition. This condition consisted of a liquid nitrogen (LN2) bath that induced temperatures of approximately -190°C, and then a transition (thermal shock) to an arc jet test at a heat rate of approximately 21 W/cm2. Both heat flux sensors that were exposed to this thermal shock experienced a blister in the thermal coating during the arc jet test.Two heat flux sensor thermal shock test series were performed to investigate the cause of the blistering and subsequent energy release. In these tests, the heat flux sensor was first cold soaked in either a dry ice or LN2 bath to induce temperatures of approximately -78°C or -190°C, respectively. Then the sensors were thermally shocked using two propane torches with a heat rate of either approximately 8 W/cm2 or 21 W/cm2. The key findings indicated that there is a correlation between thermal shock and the blistering observed in the DNH test series, and that the cause appeared to be rooted in the heat flux sensor epoxy that encapsulates the sensor thermopile.Since the heat flux sensors are required to measure heat fluxes up to 15 W/cm2 during the Mars 2020 entry, a third test series was designed to determine if blistering is an issue at this maximum expected flight heat flux. Results from all three thermal shock test series and a discussion about whether or not blistering of the heat flux sensor thermal coating could be an issue for the Mars 2020 mission will be presented.

Miller, R. A.↗

Molten Target Sputtering: Non-Conventional Method for High Mobility Si0.15Ge0.85 Growth at 500°C

Since electrons travel over 100 times faster in Silicon-Germanium (SiGe) than in pure Si due to the low effective masses associated with Ge and SiGe-based devices continue to replace Si-based solid-state electronic devices. SiGe thin film on sapphire was successfully grown at 890°C, using a magnetron sputtering system within heteroepitaxial framework. However, SiGe growth at 890oC is a costly and difficult process to produce as a uniform wafer for semiconductor device manufacturing due to thermal soak times, and geometric thermal shadowing from the wafer holder. To leverage the semiconducting capabilities of SiGe, novel processing techniques for SiGe film growth with decreased thermal loading are required. This paper introduces the Molten Target Sputtering (MTS) method that produces high mobility SiGe on sapphire below 500°C. This non-conventional method has the advantage of high kinetic energy, high-energy latency, and high flux density of sputtered atoms by combining benefits of both magnetron sputtering and thermal evaporation. For the MTS method, a 1~2 mm (depth and width) ring-shaped groove was cut between the center magnet and surrounded by electromagnets creating a circular cavity between the copper plate and source target materials that melt the target material. The SiGe grown from the MTS shows continuous morphology and 99.7% single crystal Si0.15Ge0.85 films. The Hall electron mobilities of the Si0.15Ge0.85 are 456 sq. cmV(exp -1)s(exp -1) and 123.9 sq. cmV(exp -1)s(exp -1) at 5.59 x 10(exp 18) cubic cm and 3.5 x 10(exp 20) cubic cm carrier concentration at 22.38°C, respectively. This is approximately 5.5 times higher than that of Si and similar to the Ge value at equivalent carrier concentrations and temperatures.

High mobility SiGe↗

Experimental Study on Mitigation of Lifetime-Limiting Dielectric Cracking in Extreme Temperature 4H-SiC JFET Integrated Circuits

While NASA Glenn Research Center's "Generation 10" 4H-SiC Junction Field Effect Transistor (JFET) integrated circuits (ICs) have uniquely demonstrated 500 °C electrical operation for durations of over a year, this experimental work has also revealed that physical cracking of chip dielectric passivation layers ultimately limits extreme-environment operating lifetime [1-3]. The prevention of such dielectric passivation cracks should therefore improve IC high temperature durability and yield, leading to more beneficial technology adoption into aerospace, automotive, and energy systems. This report describes Generation 10.2, 11.1, and 11.2 die tested under unbiased and unpackaged accelerated age testing at 500 °C, 600 °C, 720 °C, and 800 °C in air-atmosphere ovens for 100- and 200-hour duration. Additional samples were separately subjected to 10 thermal cycles between the same high temperatures (with 10-hour high-temperature soak each cycle) and 50 °C. It is shown that having two stoichiometric Si3N4 layers in the interconnect dielectric stack substantially decreases the amount of dielectric cracking observed following these oven tests.

Spry, D. J.↗

Development of Unsteady Pressure-Sensitive Paint Application on NASA Space Launch System

The key measurement to acquire for understanding unsteady flow is surface pressure. Unsteady Pressure-Sensitive Paint (uPSP) is an emerging optical technique used in wind tunnel testing to measure fluctuating surface pressures. Recently, tests were conducted on NASA’s Space Launch System in NASA Ames Research Center’s Unitary Plan Wind Tunnel to determine the aeroacoustics environment and assist in developing the buffet forcing functions. Unsteady PSP data was collected during this test campaign. Steady state PSP data, infrared thermography, shadowgraph, accelerometer data, and dynamic pressure transducer data were also collected. In all 50 TB of data were collected during the three days of testing. During these three days of testing, a repeating transonic and supersonic alpha sweep condition was acquired. This paper presents these two wind tunnel conditions and examines how the temperature influences the PSP data. In the first large demonstration of uPSP in 2015 on an NESC-, AETC-sponsored wind tunnel test, lifetime PSP results highlighted the influence the model temperature had on the PSP data. A best practice of heat soaking the model before acquiring calibration images was followed during the test campaign presented in this paper. An infrared thermography camera and thermocouples were installed in the model to collect more details of the model surface temperature. Data processing schemes for uPSP are still in development but will be briefly presented here as well.

Roozeboom, Nettie H.↗

Cryogenic Angle Measurement at NASA Langley

NASA’s National Transonic Facility is one of the few cryogenic wind-tunnel facilities in the world, where tunnel conditions may reach -250 F. Model angle of attack (AoA) at NTF is typically measured by an on-board accelerometer package that is exposed to the cryogenic tunnel conditions. These NTF AoA packages house two Q-Flex accelerometers in a compact heated environment in order to maintain constant temperature of the sensors for stability. Recently, drift in sensor output was observed in one of the NTF AoA packages. The drift is correlated with the AoA package temperature and cryogenic soak time. This paper studies the temperature and time dependent behavior of the NTF AoA packages, and reviews their design and calibration. Recommended improvements to the AoA packages are made to improve the stability of the model angle of attack measurements at cryogenic conditions.

Toro, Kenneth G.↗

The Effects of Plasma Application on Radish Seeds with Implications for Space Crop Production

In extended space missions, the astronaut diet will consist mostly of prepackaged foods. This could result in nutritional deficiencies due to the gradual breakdown of certain vitamins. To address this deficiency, fresh produce must be grown from seed during spaceflight. Stored seeds, however, can be vulnerable to microbial contamination which could jeopardize plant health and crop food safety. To alleviate this concern, the current practice is to sanitize seeds on the ground before spaceflight to the International Space Station (ISS). Methods of seed sanitization include alcohol soaking and chlorine gas fumigation, which have harmful effects on the environment and human health. Plasma application is a new sanitization approach that avoids these negative side effects while potentially elevating germination rate and improving growth rate; yet plasma application requires specific exposure time, power, and pressure to achieve these benefits. In the present study, Raphanus sativus ‘Cherry Belle’ radish seeds were exposed to either low pressure (Diener) plasma or atmospheric pressure plasma for varying increments of time (30s-1200s). Data collected includes immediate germination rate (viability) and microbial log reduction. Additionally, seeds were stored for later germination rate testing. Microbial assay controls have highlighted variability in initial microbial load between individual seeds, and further work is being performed to determine the standard microbial load of an untreated seed. In some samples, a negative log reduction was observed after plasma treatment encouraging further study to determine if the plasma is perforating the seed coat and releasing endophytic microbes. Treatment with Diener plasma shows promising microbial log reduction, but lower viability. In contrast, treatment with atmospheric pressure plasma offers high viability, but poor microbial log reduction. Further study will aim at determining whether plasma treatment is effective at not only sanitization, but sterilization. This research was funded by a NASA grant at the Kennedy Space Center.

Plasma↗

The Effects of Plasma Application on Radish Seeds with Implications for Space Crop Production

In extended space missions, the astronaut diet will consist mostly of prepackaged foods. This could result in nutritional deficiencies due to the gradual breakdown of certain vitamins. To address this deficiency, fresh produce must be grown from seed during spaceflight. Stored seeds, however, can be vulnerable to microbial contamination which could jeopardize plant health and crop food safety. To alleviate this concern, the current practice is to sanitize seeds on the ground before spaceflight to the International Space Station (ISS). Methods of seed sanitization include alcohol soaking and chlorine gas fumigation, which have harmful effects on the environment and human health. Plasma application is a new sanitization approach that avoids these negative side effects while potentially elevating germination rate and improving growth rate; yet plasma application requires specific exposure time, power, and pressure to achieve these benefits. In the present study, Raphanus sativus ‘Cherry Belle’ radish seeds were exposed to either low pressure (Diener) plasma or atmospheric pressure plasma for varying increments of time (30s-1200s). Data collected includes immediate germination rate (viability) and microbial log reduction. Additionally, seeds were stored for later germination rate testing. Microbial assay controls have highlighted variability in initial microbial load between individual seeds, and further work is being performed to determine the standard microbial load of an untreated seed. In some samples, a negative log reduction was observed after plasma treatment encouraging further study to determine if the plasma is perforating the seed coat and releasing endophytic microbes. Treatment with Diener plasma shows promising microbial log reduction, but lower viability. In contrast, treatment with atmospheric pressure plasma offers high viability, but poor microbial log reduction. Further study will aim at determining whether plasma treatment is effective at not only sanitization, but sterilization. This research was funded by a NASA grant at the Kennedy Space Center.

Space Crop Production↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide remains an option of choice for microbial control in spacecraft potable water systems. However, depletion of silver ions by wetted materials readily reduces ionic silver to nonbiocidal levels. This phenomenon occurs via various transport mechanisms at the liquid-solid interfaces between the silver-containing water and adjacent surfaces. Consequently, challenges remain in the design and/or selection of materials that can be used for the wetted system components that will help ensure silver is maintained at biocidal levels. Since silver has been baselined, and/or remains, as a potable water biocide option for several future spacecraft potable water systems, a multitiered approach is being investigated, looking at heritage materials, new processes, and/or alterative materials. This study conducted the application of eleven chemically-resistant coatings onto coupons that were cut out from three types of spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel) to investigate the performance of this material strategy as a barrier against silver depletion. In this investigation, the coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^(-1) and left to soak for predefined time periods. The concentration of the solution in contact with the coated samples was analyzed at various points via inductively coupled plasma mass spectrometry, and the measurements were interpreted as silver retention percentages over time. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination at diminishing silver depletion. The preliminary results demonstrate that some of the selected coatings succeeded at maintaining biocidal silver concentrations far beyond the corresponding base metal in a similar test. The knowledge acquired through this investigation supports the deploying of coatings on plumbing lines for the integration of biocidal silver in the water system architecture of a spacecraft. Nevertheless, further testing must be continued to assess the performance of these coatings on other wetted geometries and any implications of unifying this material strategy with traditional and developmental engineering design processes for spacecraft potable water systems.

water↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

The Non-Destructive Separation of Diverse Astrobiologically Relevant Organic Molecules By Customizable Capillary Zone Electrophoresis and Monolithic Capillary Electrochromatography

The in situ detection of organic molecules in space is key to understanding the variety and the distribution of the building blocks of life, and possibly the detection of extraterrestrial life itself. Gas chromatography mass spectrometry (GC-MS) has been the most sensitive analytical instrument for organic analyses in flight, and was used on missions from NASA’s Viking, Phoenix, Curiosity missions to ESA’s Rosetta space probe. While pyrolysis GC-MS revealed the first organics on Mars, this step alters or degrades certain fragile molecules that are excellent biosignatures including polypeptides, oligonucleotides and polysaccharides, rendering the intact precursors undetectable. We have identified a solution tailored to the detection of biopolymers and other biomarkers by the use of liquid-based capillary electrophoresis and electrochromatography. In this study, we show that a capillary electrochromatography (CEC) approach using monolithic stationary phases with tailor-made surface chemistry can separate and identify various polycyclic aromatic hydrocarbons (PAHs), nucleobases and aromatic acids that could be formed under astrophysically relevant conditions. In order to simulate flyby organic sample capture, we conducted hypervelocity impact experiments which consisted of accelerating peptide-soaked montmorillonite particles to a speed of 5.6 km/sec, and capturing them in an amorphous silica aerogel of 10 and 30 mg/cc bulk density. Bulk peptide extraction from aerogel followed by capillary zone electrophoresis led to the detection of only two stereoisomeric peptide peaks. The recovery rates of each step of the extraction procedure after the hypervelocity impact suggest that major peptide loss occurred during the impact. Our study provides initial exploration of feasibility of this approach for capturing intact peptides, and subsequently detecting candidate biomolecules during flight missions that would be missed by GC-MS alone. As the monolith-based electrochromatography technology could be customized to detect specific classes of compounds as well as miniaturized, these results demonstrate the potential of the instrumentation for future astrobiology-related spaceflight missions.

Flyby sample return↗

Thermal Protection System Design of Aerocapture Systems for Uranus Orbiters

The National Academies Planetary Science and Astrobiology Decadal Survey recently identified Uranus and Neptune - called Ice Giants - as the priority destinations for science[1]. The survey assessed both a mission to Uranus through the Uranus Orbiter and Probe (UOP) concept, and Neptune through the Neptune-Triton Odyssey concept and determined that Uranus is the highest priority for a Flagship class mission. The UOP mission will deliver an in situ probe and conduct a multi-year orbital tour of the system to meet the science objectives. While the Uranus mission is currently viable with launch windows starting in 2031 using existing launch vehicles, the mission has a long cruise time to destination (between 12 and 15 years) and would require more than half of its weight in fuel propellant to achieve the change in velocity necessary for orbital insertion. Aerocapture is a method of orbital control that uses aerodynamic forces generated on a vehicle by the planet’s atmosphere to modulate a spacecraft’s trajectory, allowing mission designers to target the final orbital state. For the Uranus mission, using aerocapture for orbital insertion can decrease not only the cruise time to the destination by 2 - 3 years, but the propellant required to achieve orbital insertion (by more than 40%) which would, in turn, increase the available science payload and reduce the timeline for retrieving data vital to the mission’s science objectives[2]. Achieving orbital insertion via aerocapture requires novel algorithms for Guidance, Navigation and Control[3], and mass-efficient Thermal Protection Systems (TPS) performing in a new atmosphere. This paper will focus on the selection and tailoring of the Thermal Protection Systems for the forebody and aftbody heatshields of an aerocapture mission to Uranus. While preliminary results indicate that multiple systems in NASA’s repertoire are capable of performing in the predicted aerothermal environment there are unique aspects like the inert environment that affect ablation efficiency, and the heatload for aerocapture trajectories to the outer planets are among the highest of any mission to-date[4]. These two factors may impose operational requirements to heatshield separation in order to minimize thermal soak to the payload, and may demand TPS thickness and configurations that have not yet been demonstrated. This paper will discuss the updated maturity, manufacturing, and performance capabilities of candidate thermal protection systems, with specific areas of need highlighted to make thermal protection systems viable for use in the recommended Uranus Orbiter and Probe mission.

Uranus↗

Results of First Long Duration Space Flight of Hybrid Perovskite Thin Film

In support of NASA's Artemis program with the goal of a sustained human-lunar presence, there is a need for very large (>100kW) and high-voltage-capable solar arrays, estimated to cost over $150M. Perovskite-based thin-film photovoltaics offer substantial advantages over state-of-the-art solar arrays from the perspective of manufacturing large arrays. Perovskites have also demonstrated some of the lowest temperature coefficients and highest defect tolerance, which make them excellent candidates for aerospace applications. However, MHPs must demonstrate durability in space which presents different challenges than terrestrial operating environments. To decisively test the viability of perovskites being used in space, a perovskite thin film is positioned in low earth orbit for 10 months on the International Space Station, which was the first long-duration study of an MHP in space. Postflight high-resolution ultrafast spectroscopic characterization and comparison with control samples reveal that the flight sample exhibits superior photo-stability, no irreversible radiation damage, and a suppressed structural phase transition temperature by nearly 65 K, broadening the photovoltaic operational range. Further, significant photo-annealing of surface defects is shown following prolonged light-soaking postflight. These results emphasize that methylammonium lead iodide can be packaged adequately for space missions, affirming that space stressors can be managed as theorized.

William Delmas↗

Material Compatibility Study of Coated Metals to Maintain Biocidal Silver in a Spacecraft Potable Water System

Ionic silver-based biocide is an option of strong interest for future exploration and has been baselined for several emerging spacecraft potable water systems. A challenge for the use of silver biocide remains the depletion of ionic silver on wetted materials of construction. Consequently, the design and/or selection of materials that can be used as the wetted system components need specific consideration. As part of the strategy to address this issue, a multitiered approach is being investigated that looks at combinations of conventional and non-conventional spacecraft treatment processes and materials. In this study, eleven chemically-resistant polymer coatings were applied as surface treatments onto coupons that were cut out from three types of conventional spacecraft-grade metals (Titanium Grade 2, Inconel 718, and 316L Stainless Steel). The coated metals were immersed in a static 400 parts per billion silver biocide solution at a surface-area-to-volume ratio of 2.0 cm^-1 and left to soak for predefined periods of time. The concentration of the solution in contact with the coated samples were then analyzed via inductively coupled plasma mass spectrometry, and the data used to determine the extent to which the coatings provided a barrier to silver loss. This paper summarizes the coating selection process, the configuration of the test, and the performance of each coating-metal combination as a mitigation to silver depletion. The preliminary results demonstrate that select coatings are proving effective at maintaining biocidal silver concentrations. The knowledge acquired through this investigation will be used to assess the feasibility of using these coatings as a robust strategy for maintaining biocidal silver in the water systems. Future studies are planned to assess the specific use of these coatings and to better understand the implications of utilizing this material approach in the future spacecraft potable water system designs.

coatings↗

Fracture Mechanics Testing of Titanium 6AL-4V in LMP-103S Propellant

Propellant tank safe-life analysis is a spacecraft propulsion subsystem Launch Range processing requirement. The material property inputs for the safe-life analysis include the stress intensity factor for environment-assisted cracking (KEAC). The KEAC for titanium alloy Ti 6Al-4V in LMP-103S propellant was determined experimentally using an innovative test method following ASTM E1681, Standard Test Method for Determining Threshold Stress Intensity Factor for Environment-Assisted Cracking of Metallic Materials. This effort was a collaboration between NASA Goddard Space Flight Center and NASA Kennedy Space Center to expose the test specimens in the propellant, while loaded in the test fixtures, for 1000- hour (42 days) at 50°C. Two test rounds have been completed to date; 1) testing mechanically loaded specimens but without propellant and 2) testing mechanically loaded specimens wetted with LMP-103S propellant. The dry test was to evaluate the crack growth without exposure to the LMP-103S propellant, and further assess the un-wetted stress intensity factor for the full 1000-hour duration. The second round of testing included the propellant soak for the requisite 1000- hour at 50°C. Current results show that the threshold intensity factor for environment-assisted cracking (exposed to LMP103S) is 22.5 ksi√in for the bulk material and 36. 2 ksi√in for the weld material. A generic ‘candidate’ tank geometry and material thickness is developed for a damage tolerance of known surface cracks below the nondestructive inspection technique detection limit. Evaluations with and without the use of a threshold intensity factor for environment-assisted cracking is performed for the required 4x propellant tank service life using the software tool NASGRO. SP2024_00239

Green propulsion↗