Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Comparison of internal dose estimates obtained using organ-level, voxel S value, and Monte Carlo techniques

Purpose: The authors’ objective was to compare internal dose estimates obtained using the Organ Level Dose Assessment with Exponential Modeling (OLINDA/EXM) software, the voxel S value technique, and Monte Carlo simulation. Monte Carlo dose estimates were used as the reference standard to assess the impact of patient-specific anatomy on the final dose estimate. Methods: Six patients injected with{sup 99m}Tc-hydrazinonicotinamide-Tyr{sup 3}-octreotide were included in this study. A hybrid planar/SPECT imaging protocol was used to estimate {sup 99m}Tc time-integrated activity coefficients (TIACs) for kidneys, liver, spleen, and tumors. Additionally, TIACs were predicted for {sup 131}I, {sup 177}Lu, and {sup 90}Y assuming the same biological half-lives as the {sup 99m}Tc labeled tracer. The TIACs were used as input for OLINDA/EXM for organ-level dose calculation and voxel level dosimetry was performed using the voxel S value method and Monte Carlo simulation. Dose estimates for {sup 99m}Tc, {sup 131}I, {sup 177}Lu, and {sup 90}Y distributions were evaluated by comparing (i) organ-level S values corresponding to each method, (ii) total tumor and organ doses, (iii) differences in right and left kidney doses, and (iv) voxelized dose distributions calculated by Monte Carlo and the voxel S value technique. Results: The S values for all investigated radionuclides used by OLINDA/EXM and the corresponding patient-specific S values calculated by Monte Carlo agreed within 2.3% on average for self-irradiation, and differed by as much as 105% for cross-organ irradiation. Total organ doses calculated by OLINDA/EXM and the voxel S value technique agreed with Monte Carlo results within approximately ±7%. Differences between right and left kidney doses determined by Monte Carlo were as high as 73%. Comparison of the Monte Carlo and voxel S value dose distributions showed that each method produced similar dose volume histograms with a minimum dose covering 90% of the volume (D90) agreeing within ±3%, on average. Conclusions: Several aspects of OLINDA/EXM dose calculation were compared with patient-specific dose estimates obtained using Monte Carlo. Differences in patient anatomy led to large differences in cross-organ doses. However, total organ doses were still in good agreement since most of the deposited dose is due to self-irradiation. Comparison of voxelized doses calculated by Monte Carlo and the voxel S value technique showed that the 3D dose distributions produced by the respective methods are nearly identical.

60 APPLIED LIFE SCIENCES↗

Machine Learning Based System for Automated Estimation of Crystal Unit Cell Parameters from X-ray Diffraction Powder Patterns (MLCell) v0.1

This software uses machine learning models to perform inference on X-ray diffraction powder patterns, output from a diffractometer, to estimate all 6 unit cell parameters of crystalline lattices. Novel aspects of this software originated from the incorporation of concepts from crystallography to an ML-based approach; The resulting method achieves new performance capabilities without significant loss of accuracy and with less computationally intensive models.

Oklejas, Vanessa↗

Application of Orthogonal Defect Classification for Software Reliability Analysis

The modernization of existing and new nuclear power plants with digital instrumentation and control systems (DI&C) is a recent and highly trending topic. However, there lacks strong consensus on best-estimate reliability methodologies by both the United States (U.S.) Nuclear Regulatory Commission (NRC) and the industry. This has resulted in hesitation for further modernization projects until a more unified methodology is realized. In this work, we develop an approach called Orthogonal-defect Classification for Assessing Software Reliability (ORCAS) to quantify probabilities of various software failure modes in a DI&C system. The method utilizes accepted industry methodologies for software quality assurance that are also verified by experimental or mathematical formulations. In essence, the approach combines a semantic failure classification model with a reliability growth model to predict (and quantify) the potential failure modes of a DI&C software system. The semantic classification model is used to address the question: How do latent defects in software contribute to different software failure root causes? The use of reliability growth models is then used to address the question: Given the connection between latent defects and software failure root causes, how can we quantify the reliability of the software? A case study was conducted on a representative I&C platform (ChibiOS) running a smart sensor acquisition software developed by Virginia Commonwealth University (VCU). The testing and evidence collection guidance in ORCAS was applied, and defects were uncovered in the software. Qualitative evidence, such as condition coverage, was used to gauge the completeness and trustworthiness of the assessment while quantitative evidence was used to determine the software failure probabilities. The reliability of the software was then estimated and compared to existing operational data of the sensor device. It is demonstrated that by using ORCAS, a semantic reasoning framework can be developed to justify software reliability (or unreliability) while still leveraging the strength of the existing methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HPC Usage Behavior Analysis and Performance Estimation with Machine Learning Techniques

Most researchers with little high performance computing (HPC) experience have difficulties productively using the supercomputing resources. To address this issue, we investigated usage behaviors of the world s fastest academic Kraken supercomputer, and built a knowledge-based recommendation system to improve user productivity. Six clustering techniques, along with three cluster validation measures, were implemented to investigate the underlying patterns of usage behaviors. Besides manually defining a category for very large job submissions, six behavior categories were identified, which cleanly separated the data intensive jobs and computational intensive jobs. Then, job statistics of each behavior category were used to develop a knowledge-based recommendation system that can provide users with instructions about choosing appropriate software packages, setting job parameter values, and estimating job queuing time and runtime. Experiments were conducted to evaluate the performance of the proposed recommendation system, which included 127 job submissions by users from different research fields. Great feedback indicated the usefulness of the provided information. The average runtime estimation accuracy of 64.2%, with 28.9% job termination rate, was achieved in the experiments, which almost doubled the average accuracy in the Kraken dataset.

Zhang, Hao↗

Application of Orthogonal Defect Classification for Software Reliability Analysis

The modernization of existing and new nuclear power plants with digital instrumentation and control systems (DI&C) is a recent and highly trending topic. However, there lacks strong consensus on best-estimate reliability methodologies by both the United States (U.S.) Nuclear Regulatory Commission (NRC) and the industry. This has resulted in hesitation for further modernization projects until a more unified methodology is realized. In this work, we develop an approach called Orthogonal-defect Classification for Assessing Software Reliability (ORCAS) to quantify probabilities of various software failure modes in a DI&C system. The method utilizes accepted industry methodologies for software quality assurance that are also verified by experimental or mathematical formulations. In essence, the approach combines a semantic failure classification model with a reliability growth model to predict (and quantify) the potential failure modes of a DI&C software system. The semantic classification model is used to address the question: How do latent defects in software contribute to different software failure root causes? The use of reliability growth models is then used to address the question: Given the connection between latent defects and software failure root causes, how can we quantify the reliability of the software? A case study was conducted on a representative I&C platform (ChibiOS) running a smart sensor acquisition software developed by Virginia Commonwealth University (VCU). The testing and evidence collection guidance in ORCAS was applied, and defects were uncovered in the software. Qualitative evidence, such as condition coverage, was used to gauge the completeness and trustworthiness of the assessment while quantitative evidence was used to determine the software failure probabilities. The reliability of the software was then estimated and compared to existing operational data of the sensor device. It is demonstrated that by using ORCAS, a semantic reasoning framework can be developed to justify if the software is reliable (or unreliable) while still leveraging the strength of the existing methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Software Quality Metrics for Geant4: An Initial Assessment - Paper 122

In the context of critical applications, such as shielding and radiation protection, ensuring the quality of simulation software they depend on is of utmost importance. The assessment of simulation software quality is crucial both to determine its adoption in experimental applications and to guarantee reproducibility of outcome over time. Geant4 is a simulation system used in a wide range of experimental applications, some of which, such as radiation protection and biomedical studies, may involve critical use cases and would especially profit from an objective assessment of the software quality. In this study, we present the first results from an ongoing analysis of Geant4 code based on established software metrics from the perspective of software engineering. The analysis evaluates the current status of the code to quantify its characteristics with respect to documented quality standards; further appraisals concern evolutions over a series of release distributions. The quantitative assessment of the software is initially focused on a subset of Geant4 packages, which play a key role in scientific applications and are representative of different software development processes. We describe the chosen software metrics that map the entities of a software system to numeric values through mathematical definitions, quantifying software attributes ranging from functionality to maintainability. To measure such metrics, we exploited a set of software metrics tools, i.e. programs that implement a set of software metrics definitions. They allow software engineers to assess a software system by extracting the required attributes from the software and providing the corresponding metric values. To correlate software metrics values in a well-defined way, we used software quality standard models, such as the ISO/IEC 9126 standard, which aggregate numerical values to aid quality analysis and assessment. With this work we aim to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. Furthermore, we intend to highlight what metrics are most effective at evaluating radiation transport software quality. We are confident that the result will provide constructive guidance both to improve key software tools, such as Geant4, and to estimate their contribution in risk analysis concerning sensitive applications. The remainder of this paper is structured as follows. We first discuss the approach adopted to fulfil our assessment. Then, we present the setup of our experiments and the way we collected data. We provide an initial interpretation of a subset of data resulting from measurements made on the selected Geant4 packages. As the analysis is still ongoing at the time of submitting this abstract, some results will be documented in the final paper and in the conference presentation. With this work we aim to create a proper Geant4 data set for evaluating its software characteristics and identifying both strengths and weaknesses. In this initial study, we considered the geometry and processes packages, which play a major role in most simulation applications. The data analysis is in progress at the time of writing; its complexity is related to the differences among software metrics tools, to the large amount of data to be evaluated and to the pioneering character of this project. We are confident that the results will provide valuable indications for the Geant4 user community and constructive guidance to improve key Geant4 packages. Other Monte Carlo codes could profit from the methodology developed in this pilot project for similar assessments of their software quality. At the end of this study, we intend to create a baseline for evaluating correlations between software quality embedded in the Geant4 development process and simulation observables produced by Geant4-based applications. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantification and evaluation of strain reduction from small-bubble gas injection in Spallation Neutron Source target vessels

Small-bubble gas injection has been routinely utilized in the operation of Spallation Neutron Source (SNS) mercury targets since 2017 to mitigate cavitation-induced erosion damage to target vessels. Strain measurements of target vessels collected in-situ during initial operation with gas injection were used to study the gas injection effect on the structural response of targets to proton pulses. A significant strain reduction owing to gas injection was found by comparing the strain measurement data during operation with and without gas injection. The research presented here focuses on quantifying strain reductions in SNS targets and evaluating the effect of small-bubble gas injection by comparing different bubbler types and target designs. The strain measurement results show the gas injection significantly reduced strain in SNS target vessels; strain values decreased by 30% to 80% for targets operating with gas injection. Stress and strain responses of SNS targets were simulated to numerically evaluate the gas injection effect. Based on the predicted stresses with and without gas injection, the fatigue lifetimes of SNS jet-flow design target were estimated using fe-safe fatigue analysis software. The simulations show these reductions should improve the fatigue life of target vessels and allow SNS targets to meet their fatigue design goal.

Fatigue life estimation↗

Review of Software Packages for Local Intense Precipitation Flood Modeling

This report documents the review of the hydrologic and hydraulic modeling approaches used to estimate local intense precipitation (LIP) flooding and their implementation in readily available simulation software packages. The review focused on a few representative simulation software packages because of the similarity of their underlying mathematical bases and the rainfall-runoff and hydraulic processes included. Their availability for use in estimating LIP flood hazards and for U.S. Nuclear Regulatory Commission staff review of these estimates at the nuclear power plant (NPP) site scale were also considered.

54 ENVIRONMENTAL SCIENCES↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

54 ENVIRONMENTAL SCIENCES↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

58 GEOSCIENCES↗

Power, Optimization, Waste Estimating, Resourcing Tool

Planning, Optimization, Waste Estimating, Resourcing tool (POWERtool) is a comprehensive relational database software tool that can be used to develop and organize a detailed project scope, plan work tasks, develop bottoms-up field cost and waste estimates for facility Deactivation and Decommissioning (D&D), equipment, and environmental restoration (ER) projects and produces resource-loaded schedules.

Nelson, Jerel↗

Absorption Correction for Reliable Pair Distribution Functions from Low Energy X-ray Sources

This paper explores the development and testing of a simple absorption correction model for processing powder X-ray diffraction data from Debye−Scherrer geometry laboratory X-ray experiments. This may be used as a preprocessing step before using PDFGETX3 to obtain reliable pair distribution functions (PDFs). Various experimental and theoretical methods for estimating μR were explored, and the most appropriate μR values for correction were identified for different capillary diameters and X-ray beam sizes. We identify operational ranges of μR where a reasonable signal-to-noise ratio is possible after correction. A user-friendly software package, DIFFPY.LABPDFPROC, is presented that can help estimate μR and perform absorption corrections with a rapid calculation for efficient processing.

Absorption↗

The generation of shared cryptographic keys through channel impulse response estimation at 60 GHz.

Methods to generate private keys based on wireless channel characteristics have been proposed as an alternative to standard key-management schemes. In this work, we discuss past work in the field and offer a generalized scheme for the generation of private keys using uncorrelated channels in multiple domains. Proposed cognitive enhancements measure channel characteristics, to dynamically change transmission and reception parameters as well as estimate private key randomness and expiration times. Finally, results are presented on the implementation of a system for the generation of private keys for cryptographic communications using channel impulse-response estimation at 60 GHz. The testbed is composed of commercial millimeter-wave VubIQ transceivers, laboratory equipment, and software implemented in MATLAB. Novel cognitive enhancements are demonstrated, using channel estimation to dynamically change system parameters and estimate cryptographic key strength. We show for a complex channel that secret key generation can be accomplished on the order of 100 kb/s.

99 GENERAL AND MISCELLANEOUS↗

NONPARAMETRIC EMPIRICAL BAYES ESTIMATION THROUGH DECONVOLUTION IN PROBABILISTIC RISK ANALYSIS

The advent of Markov Chain Monte Carlo (MCMC) simulations and availability of open source software made full hierarchical Bayesian analysis tractable and a popular choice in parameter estimation for Probabilistic Risk Assessment (PRA). However, despite its theoretical attractiveness, the hierarchical Bayesian analysis is not without its problems. Two of the most prominent practical difficulties in applying hierarchical Bayes analysis in practice to analyze source-to-source variability, for example, is its sensitivity to the selection of the first-stage prior and dependence of the rate of convergence on the selection of the first-stage prior. The first-stage prior in hierarchical Bayesian analysis is usually assumed having a parametric form, often conjugate to the likelihood function (aleatory model). To facilitate convergence for hierarchical Bayes models, the first-stage prior is frequently set through empirical Bayes estimate, which can use available historical data to find the parameters of the first-stage prior. The paper discusses a new nonparametric empirical Bayes estimation and compare it to several well-known parametric estimates such as method of moments and maximum likelihood. The new nonparametric technique exploits the prior predictive distribution as integral equation and proceeds to solve it with respect to prior assuming the sampling data distribution and aleatory model are available. The discussion covers topics such as selection of aleatory model for future data, selection of regularization parameter, and density estimation for historical data. For comparison, the paper is using contrived as well as real-world data from utilities. Utilities data represent failure data with Poisson distribution used for aleatory model.

97 MATHEMATICS AND COMPUTING↗

ForceFinder

SAND2025-11750O ForceFinder extends the Structural Dynamics Python Libraries (SDynPy) with comprehensive tools for inverse source estimation (ISE) tasks via frequency response function (FRF) matrix inversion. The software is designed for transfer path analysis and multiple-input/multiple-output (MIMO) vibration control problems. It allows users to estimate sources through various algorithms, from the basic Moore-Penrose pseudo-inverse to statistical learning methods such as Tikhonov regularization via an L-curve and elastic net regularization via an information criterion. ForceFinder uses an object-oriented framework, where all components of the ISE problem—such as FRFs, responses, and transformations—are stored in a "SourcePathReceiver" object. This software can be applied to any noise and vibration problem. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Carter, Steven [Sandia National Lab. (SNL-CA), Liv↗

Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography

Background: We compared two reconstruction algorisms and two cardiac functional evaluation software programs in terms of their accuracy for estimating ejection fraction (EF) of small hearts (SH). Methods: The study group consisted of 66 pediatric patients. Data were reconstructed using a filtered back projection (FBP) method without the resolution correction (RC) and an iterative method based on an ordered subset expectation maximization (OSEM) algorithm with the RC. EF was evaluated using two software programs of quantitative gated single-photon emission computed tomography (SPECT) (QGS) and cardioREPO. We compared the EF of gated myocardial perfusion SPECT to echocardiographic measurement (Echo). Results: Forty-eight of 66 patients had an end-systolic volume < 20 mL which was used as the criterion for being included in the SH group, and the SH effect led to an overestimation of EF. While significant differences were observed between Echo (66.9 ± 5.0%) and QGS-FBP without RC (76.9 ± 8.4%, P < .0001), QGS-OSEM with RC (76.6 ± 8.6%, P < .0001), and cardioREPO-FBP without RC (72.1 ± 10.0%, P = .0011), no significant difference was observed between Echo and cardioREPO-OSEM with RC (67.4 ± 6.1%) in SH group. Conclusions: In pediatric gated myocardial perfusion SPECT, the SH effect can be significantly reduced when an OSEM algorithm is used with RC in combination with the specific cardioREPO algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Introduction to Goodness of Fit for PMU Parameter Estimation

New results of measurements of phasor-like signals are presented based on our previous work on the topic. In this document an improved estimation method is described. The algorithm (which is realized in MATLAB software) is discussed. We examine the effect of noisy and distorted signals on the Goodness of Fit metric. The estimation method is shown to be performing very well with clean data and with a measurement window as short as a half a cycle and as few as 5 samples per cycle. The Goodness of Fit decreases predictably with added phase noise, and seems to be acceptable even with visible distortion in the signal. While the exact results we obtain are specific to our method of estimation, the Goodness of Fit method could be implemented in any phasor measurement unit.

97 MATHEMATICS AND COMPUTING↗

A Refined Method to Translate Solar Data Quality Assessment Flags to Estimated Measurement Uncertainty

Integrating solar resource uncertainties due to radiometer measurement performance and operational data quality assessment can provide improved estimates of economic bankability, system design performance, and compliance of solar energy conversion systems. Estimating radiometer measurement uncertainty is an established procedure consistent with recognized best practices and international guidelines. SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the fourth of six for the Data Quality and Uncertainty Integration Project, presents a refined algorithm description for software to translate solar resource data quality assessment results into estimated uncertainty values in a Solar Resource Operational Uncertainty Integrator (SROUI) application. This algorithm requires three-component solar irradiance measurements - global horizontal irradiance, direct normal irradiance, and diffuse horizontal irradiance - collected at 1- to 60-minute intervals, as described in the previous deliverables. The development of this report as Deliverable 6.4 was an iterative process that included reviews and feedback from the project team on initial drafts designed to refine how the new software could best support determining solar resource data uncertainty. The results of this effort will contribute to the final software system development by National Renewable Energy Laboratory staff.

14 SOLAR ENERGY↗