Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid state frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Q-Band (37-41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37-41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cut-paraboloidal reflector.

Simmons, Rainee N.↗

High-Resolution Electron Energy-Loss Spectroscopy (HREELS) Using a Monochromated TEM/STEM

A 200 keV FEI TF20 XT monochromated (scanning) transmission electron microscope funded by NASA's SRLIDAP program is undergoing installation at Lawrence Livermore National Laboratory. Instrument specifications in STEM mode are Cs =1.0 mm, Cc =1.2 mm, image resolution =0.18 nm, and in TEM mode Cs =1.3 mm, Cc =1.3 mm, information limit =0.14 nm. Key features of the instrument are a voltage-stabilized high tension (HT) supply, a monochromator, a high-resolution electron energy-loss spectrometer/energy filter, a high-resolution annular darkfield detector, and a solid-state x-ray energy-dispersive spectrometer. The high-tension tank contains additional sections for 60Hz and high frequency filtering, resulting in an operating voltage of 200 kV plus or minus 0.005V, a greater than 10-fold improvement over earlier systems. The monochromator is a single Wien filter design. The energy filter is a Gatan model 866 Tridiem-ERS high resolution GIF spec d for less than or equal to 0.15 eV energy resolution with 29 pA of current in a 2 nm diameter probe. 0.13 eV has already been achieved during early installation. The x-ray detector (EDAX/Genesis 4000) has a take-off angle of 20 degrees, an active area of 30 square millimeters, and a solid angle of 0.3 steradians. The higher solid angle is possible because the objective pole-piece allows the detector to be positioned as close as 9.47 mm from the specimen. The voltage-stabilized HT supply, monochromator and GIF enable high-resolution electron energy-loss spectroscopy (HREELS) with energy resolution comparable to synchrotron XANES, but with approximately 100X better spatial resolution. The region between 0 and 100 eV is called the low-loss or valence electron energy-loss spectroscopy (VEELS) region where features due to collective plasma oscillations and single electron transitions of valence electrons are observed. Most of the low-loss VEELS features we are detecting are being observed for the first time in IDPs. A major focus of our research is to understand the origin and significance of these features and how they might be exploited to gain insight about IDPs and other meteoritic materials.

Sai, Z. R.↗

Broadly tunable high-power operation of an all-solid-state titanium-doped sapphire laser system

Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).

Steele, T. R.↗

NASA Tech Briefs, February 2010

Topics covered include: Insulation-Testing Cryostat With Lifting Mechanism; Optical Testing of Retroreflectors for Cryogenic Applications; Measuring Cyclic Error in Laser Heterodyne Interferometers; Self-Referencing Hartmann Test for Large-Aperture Telescopes; Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser; Reconfigurable Hardware for Compressing Hyperspectral Image Data; Spatio-Temporal Equalizer for a Receiving-Antenna Feed Array; High-Speed Ring Bus; Nanoionics-Based Switches for Radio-Frequency Applications; Lunar Dust-Tolerant Electrical Connector; Compact, Reliable EEPROM Controller; Quad-Chip Double-Balanced Frequency Tripler; Ka-Band Waveguide Two-Way Hybrid Combiner for MMIC Amplifiers; Radiation-Hardened Solid-State Drive; Use of Nanofibers to Strengthen Hydrogels of Silica, Other Oxides, and Aerogels; Two Concepts for Deployable Trusses; Concentric Nested Toroidal Inflatable Structures; Investigating Dynamics of Eccentricity in Turbomachines; Improved Low-Temperature Performance of Li-Ion Cells Using New Electrolytes; Integrity Monitoring of Mercury Discharge Lamps; White-Light Phase-Conjugate Mirrors as Distortion Correctors; Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer; ICER-3D Hyperspectral Image Compression Software; and Context Modeler for Wavelet Compression of Spectral Hyperspectral Images.

Source record↗

Experimental Characterization of the Space Launch System Block 1B Liftoff and Transition Environment

A wind tunnel test was conducted at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel to evaluate the liftoff and transition flow environment of the Space Launch System Block 1B launch vehicles and tower interference effects with the newly designed Mobile Launcher 2. This test leveraged several unique diagnostic capabilities, including eight distributed force and moment measurements on the launch tower tiers, new umbilical and crew access arm configurations, and unsteady pressure acquisition on the rocket nose in the cargo configuration. The tower loading revealed a strong impact of the SLS vehicle height on force coefficients for individual tiers. Although the umbilicals produced weak influence on the loading on both vehicle and launch tower, unsteady pressure measurements revealed a slight increase in fundamental pressure oscillation frequency at specific wind azimuth directions. Multimodal flow states were observed in the gap flow between the vehicle and solid rocket boosters, producing different load profiles along the vehicle that are now incorporated in the vehicle database. This phenomenon was investigated using time-series measurements of forces as well as tufts and smoke flow visualization.

Lee J Mears↗

Experimental Characterization of the Space Launch System Block 1B Liftoff and Transition Environment

A wind tunnel test was conducted at the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel to evaluate the liftoff and transition flow environment of the Space Launch System Block 1B launch vehicles and tower interference effects with the newly designed Mobile Launcher 2. This test leveraged several unique diagnostic capabilities, including eight distributed force and moment measurements on the launch tower tiers, new umbilical and crew access arm configurations, and unsteady pressure acquisition on the rocket nose in the cargo configuration. The tower loading revealed a strong impact of the SLS vehicle height on force coefficients for individual tiers. Although the umbilicals produced weak influence on the loading on both vehicle and launch tower, unsteady pressure measurements revealed a slight increase in fundamental pressure oscillation frequency at specific wind azimuth directions. Multimodal flow states were observed in the gap flow between the vehicle and solid rocket boosters, producing different load profiles along the vehicle that are now incorporated in the vehicle database. This phenomenon was investigated using time-series measurements of forces as well as tufts and smoke flow visualization.

SLS↗

Diode laser-pumped solid-state lasers

An evaluation is made of the consequences for solid-state lasers of novel diode laser-pumping technology. Diode laser-pumped neodymium lasers have operated at an electrical-to-optical efficiency of 10 percent in a single spatial mode, with linewidths of less than 10 kHz, and with a spectral power brightness sufficiently great to allow frequency extension by harmonic generation in nonlinear crystals; this has yielded green and blue sources of coherent radiation. Q-switched operation with kW peak powers and mode-locked operation with 10-picosec pulse widths have also been demonstrated. All-solid-state lasers at prices comparable to those of current flash-lamp-pumped laser systems are foreseen, as are power levels exceeding 1 kW, for coherent radar, global satellite sensing, and micromachining.

Byer, Robert L.↗

Injection seeding of a Q-switched alexandrite laser: Study of frequency stabilization

AlGaAs diode lasers were used to injection seed a pulsed Q-switched alexandrite laser which produces a narrowband of radiation. Injection seeding is a method for achieving linewidths of less than 500 mega-Hz in the output of the broadband, tunable solid state laser. When the laser was set at a current of 59.8 milli-A and a temperature of 14.04 C, the wavelength was 767.6 nano-m. The Q-switched alexandrite laser was injection seeded and frequency stabilization was studied. The linewidth requirement was met, but the stability requirement was not due to drifting in the feedback voltage. Improvements on injection seeding should focus on increasing the feedback voltage to the laser diode, filtering the laser diode by using temperature controlled narrowband filters, and the use of diamond (SiC) grating placed inside the alexandrite laser's resonator cavity.

Brown, Lamarr A.↗

Solid-state switch increases switching speed

Solid state switch for commutating capacitors in an RC commutated network increases switching speed and extends the filtering or commutating frequency spectrum well into the kilocycle region. The switch is equivalent to the standard double- pole double-throw /DPDT/ relay and is driven from digital micrologic circuits.

Mc~gowan, G. F.↗

Carbon nanotube Schottky diodes using Ti-Schottky and Pt-ohmic contacts for high frequency applications

We have demonstrated Schottky diodes using semiconducting single-walled nanotubes (s-SWNTs) with titanium Schottky and platinum Ohmic contacts for high-frequency applications. The diodes are fabricated using angled evaporation of dissimilar metal contacts over an s-SWNT. The devices demonstrate rectifying behavior with large reverse bias breakdown voltages of greater than 15 V. To decrease the series resistance, multiple SWNTs are grown in parallel in a single device, and the metallic tubes are burnt-out selectively. At low biases these diodes showed ideality factors in the range of 1.5 to 1.9. Modeling of these diodes as direct detectors at room temperature at 2.5 terahertz (THz) frequency indicates noise equivalent powers (NEP) potentially comparable to that of the state-of-the-art gallium arsenide solid-state Schottky diodes, in the range of 10-13 W(square root)xHz.

semiconducting↗

High Efficiency Ka-Band Solid State Power Amplifier Waveguide Power Combiner

A novel Ka-band high efficiency asymmetric waveguide four-port combiner for coherent combining of two Monolithic Microwave Integrated Circuit (MMIC) Solid State Power Amplifiers (SSPAs) having unequal outputs has been successfully designed, fabricated and characterized over the NASA deep space frequency band from 31.8 to 32.3 GHz. The measured combiner efficiency is greater than 90 percent, the return loss greater than 18 dB and input port isolation greater than 22 dB. The manufactured combiner was designed for an input power ratio of 2:1 but can be custom designed for any arbitrary power ratio. Applications considered are NASA s space communications systems needing 6 to 10 W of radio frequency (RF) power. This Technical Memorandum (TM) is an expanded version of the article recently published in Institute of Engineering and Technology (IET) Electronics Letters.

Wintucky, Edwin G.↗

Characterization of the relationship of the cure cycle chemistry to cure cycle processing properties

Dynamic Dielectric measurements made over a wide range of frequency provide a sensitive and convenient means for monitoring the cure process in thermosets and thermoplastics. The measurement of dielectric relaxation is one of only a few instrumental techniques available for studying molecular properties in both the liquid and solid states. Furthermore, it is probably the only convenient experimental technique for studying the polymerization process of going from a monomeric liquid of varying viscosity to a crosslinked, insoluble, high temperature solid. The objective of the research is to develop on-line dielectric instrumentation for quantitative nondestructive material evaluation and closed loop smart cure cycle control. The key is to relate the chemistry of the cure cycle process to the dielectric properties of the polymer system by correlating the time, temperature, and frequency dependent dielectric measurements with chemical characterization measurements. Measurement of the wide variation in magnitude of the complex permittivity with both frequency and state of cure, coupled with chemical characterization work, have been shown in the laboratory to have the potential to determine: resin quality, composition and age; cure cycle window boundaries; onset of flow and point of maximum flow; extent of and completion of reaction; evolution of volatiles; T sub g; and, crosslinking and molecular weight buildup.

Kranbuehl, D. E.↗

On the length scale and rate-dependent mechanical behavior of monolithic (oxy)sulfidic glassy solid-state electrolytes

In the controlled atmosphere of a dedicated glove box, nanoindentation performed with a diamond Berkovich indenter tip has been used to examine the mechanical behavior of three (oxy)sulfide solid-state electrolytes (SSEs), 70Li 2 S·(30–x)P 2 S 5 ·xP 2 O 5 (x = 0, 2, and 5). At a drive frequency of 120 Hz, the elastic modulus is found to be predominantly depth independent over the range of 100 nm to 1 μm and generally insensitive to the varying mol fraction of oxygen (0, 2, and 5%) as well as the imposed strain rates of 0.025, 0.05, and 0.1 1/s. All three SSEs exhibit significant room-temperature creep. Strain burst activity observed during loading (potentially representative of pore collapse or cracking) is attenuated with the addition of oxygen. The hardness is found to be insensitive to the imposed strain rates but varying with depth and oxygen content. Furthermore, the highest oxygen concentration yields the lowest hardness and strongest depth dependence.

36 MATERIALS SCIENCE↗

Solid-to-plasma transition of polystyrene induced by a nanosecond laser pulse within the context of inertial confinement fusion

Laser Direct Drive (LDD) Inertial Confinement Fusion (ICF) involves irradiating a spherical target of thermonuclear fuel coated with an ablator, usually made of polystyrene. Laser energy absorption near the target surface leads to matter ablation, hydrodynamic shocks, and ultimately capsule implosion. The conservation of spherical symmetry is crucial for implosion efficiency, yet spatial modulations in laser intensity can induce nonuniformities, causing the laser imprint phenomenon. Understanding laser imprint, especially considering the initial solid state, is essential for advancing LDD ICF. A first microscopic model of solid-to-plasma transition was built in 2019, accounting for laser absorption in the solid state with a band structure based ionization model. This model has been improved to include chemical fragmentation and a more accurate description of electron collision frequency in various matter states. The latest development involves assessing the model reliability by comparing theoretical predictions with experimental observations. Despite the success of this approach, questions remain, leading to further investigations and observations under different irradiation conditions. This work presents an experiment with a nanosecond pulse, taking into account hydrodynamic effects, and measures transmission dynamics over the entire laser beam area to observe two-dimensional effects. As a result, the objective is to adapt the theoretical model, couple it with a hydrodynamic code, and observe additional effects related to the initial solid state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Miniature biotelemeter gives multichannel wideband biomedical data

A miniature biotelemeter was developed for sensing and transmitting multiple channels of biomedical data over a radio link. The design of this miniature, 10-channel, wideband (5 kHz/channel), pulse amplitude modulation/ frequency modulation biotelemeter takes advantage of modern device technology (e.g., integrated circuit operational amplifiers, complementary symmetry/metal oxide semiconductor logic, and solid state switches) and hybrid packaging techniques. The telemeter is being used to monitor 10 channels of neuron firings from specific regions of the brain in rats implanted with chronic electrodes. Design, fabrication, and testing of an engineering model biotelemeter are described.

Carraway, J. B.↗

Solid-state X-band Combiner Study

The feasibility of developing solid-state amplifiers at 4 and 10 GHz for application in spacecraft altimeters was studied. Bipolar-transistor, field-effect-transistor, and Impatt-diode amplifier designs based on 1980 solid-state technology are investigated. Several output power levels of the pulsed, low-duty-factor amplifiers are considered at each frequency. Proposed transistor and diode amplifier designs are illustrated in block diagrams. Projections of size, weight, and primary power requirements are given for each design.

Pitzalis, O., Jr.↗

Monitoring Polymer Curing Via Electromagnetic Impedance

New nondestructive in-situ electromagnetic-impedance measurement technique senses cure-processing properties of high-temperature, high-performance thermostat and thermoplastic resins. Continuous frequency-dependent measurement and analysis performed during curing cycle. Monitors and measures molecular properties of polymeric resin in liquid and solid states. Applications include nondestructive means for evaluation of materials, determination of "window" boundaries of curing cycles of thermoplastics and thermoset resins, and for online, closed-loop control of curing cycles.

Freeman, William T.↗