Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-F-BRD-09: A Random Walk Model Algorithm for Proton Dose Calculation

Purpose: To develop a random walk model algorithm for calculating proton dose with balanced computation burden and accuracy. Methods: Random walk (RW) model is sometimes referred to as a density Monte Carlo (MC) simulation. In MC proton dose calculation, the use of Gaussian angular distribution of protons due to multiple Coulomb scatter (MCS) is convenient, but in RW the use of Gaussian angular distribution requires an extremely large computation and memory. Thus, our RW model adopts spatial distribution from the angular one to accelerate the computation and to decrease the memory usage. From the physics and comparison with the MC simulations, we have determined and analytically expressed those critical variables affecting the dose accuracy in our RW model. Results: Besides those variables such as MCS, stopping power, energy spectrum after energy absorption etc., which have been extensively discussed in literature, the following variables were found to be critical in our RW model: (1) inverse squared law that can significantly reduce the computation burden and memory, (2) non-Gaussian spatial distribution after MCS, and (3) the mean direction of scatters at each voxel. In comparison to MC results, taken as reference, for a water phantom irradiated by mono-energetic proton beams from 75 MeV to 221.28 MeV, the gamma test pass rate was 100% for the 2%/2mm/10% criterion. For a highly heterogeneous phantom consisting of water embedded by a 10 cm cortical bone and a 10 cm lung in the Bragg peak region of the proton beam, the gamma test pass rate was greater than 98% for the 3%/3mm/10% criterion. Conclusion: We have determined key variables in our RW model for proton dose calculation. Compared with commercial pencil beam algorithms, our RW model much improves the dose accuracy in heterogeneous regions, and is about 10 times faster than MC simulations.

60 APPLIED LIFE SCIENCES↗

Turbulence-induced relative velocity of dust particles. II. The bidisperse case

We extend our earlier work on turbulence-induced relative velocity between equal-size particles (Paper I, in this series) to particles of arbitrarily different sizes. The Pan and Padoan (PP10) model shows that the relative velocity between different particles has two contributions, named the generalized shear and acceleration terms, respectively. The generalized shear term represents the particles' memory of the spatial flow velocity difference across the particle distance in the past, while the acceleration term is associated with the temporal flow velocity difference on individual particle trajectories. Using the simulation of Paper I, we compute the root-mean-square relative velocity, (w {sup 2}){sup 1/2}, as a function of the friction times, τ{sub p1} and τ{sub p2}, of the two particles and show that the PP10 prediction is in satisfactory agreement with the data, confirming its physical picture. For a given τ{sub p1} below the Lagrangian correlation time of the flow, T{sub L}, (w {sup 2}){sup 1/2} as a function of τ{sub p2} shows a dip at τ{sub p2} ≅ τ{sub p1}, indicating tighter velocity correlation between similar particles. Defining a ratio f ≡ τ{sub p,{sub l}}/τ{sub p,{sub h}}, with τ{sub p,{sub l}} and τ{sub p,{sub h}} the friction times of the smaller and larger particles, we find that (w {sup 2}){sup 1/2} increases with decreasing f due to the generalized acceleration contribution, which dominates at f ≲ 1/4. At a fixed f, our model predicts that (w {sup 2}){sup 1/2} scales as τ{sub p,h}{sup 1/2} for τ{sub p,{sub h}} in the inertial range of the flow, stays roughly constant for T{sub L} ≲ τ{sub p,{sub h}} ≲ T{sub L}/f, and finally decreases as τ{sub p,h}{sup −1/2} for τ{sub p,{sub h}} >> T{sub L}/f. The acceleration term is independent of the particle distance, r, and reduces the r dependence of (w {sup 2}){sup 1/2} in the bidisperse case.

79 ASTRONOMY AND ASTROPHYSICS↗

First demonstration of ARC-accelerated proton beams at the National Ignition Facility

New short-pulse kilojoule, Petawatt-class lasers, which have recently come online and are coupled to large-scale, many-beam long-pulse facilities, undoubtedly serve as very exciting tools to capture transformational science opportunities in high energy density physics. These short-pulse lasers also happen to reside in a unique laser regime: very high-energy (kilojoule), relatively long (multi-picosecond) pulse-lengths, and large (10s of micron) focal spots, where their use in driving energetic particle beams is largely unexplored. Proton acceleration via Target Normal Sheath Acceleration (TNSA) using the Advanced Radiographic Capability (ARC) short-pulse laser at the National Ignition Facility in the Lawrence Livermore National Laboratory is demonstrated for the first time, and protons of up to 18 MeV are measured using laser irradiation of >1 ps pulse-lengths and quasi-relativistic (10 18 W/cm 2 ) intensities. This is indicative of a super-ponderomotive electron acceleration mechanism that sustains acceleration over long (multi-picosecond) time-scales and allows for proton energies to be achieved far beyond what the well-established scalings of proton acceleration via TNSA would predict at these modest intensities. Furthermore, the characteristics of the ARC laser (large ~100 μ m diameter focal spot, flat spatial profile, multi-picosecond, relatively low prepulse) provide acceleration conditions that allow for the investigation of 1D-like particle acceleration. A high flux ~50 J of laser-accelerated protons is experimentally demonstrated. In conclusion, a new capability in multi-picosecond particle-in-cell simulation is applied to model the data, corroborating the high proton energies and elucidating the physics of multi-picosecond particle acceleration.

43 PARTICLE ACCELERATORS↗

Tape-Drive Based Plasma Mirror

We present experimental results on a tape-drive based plasma mirror which could be used for a compact coupling of a laser beam into a staged laser driven electron accelerator. This novel kind of plasma mirror is suitable for high repetition rates and for high number of laser shots. In order to design a compact, staged laser plasma based accelerator or collider [1], the coupling of the laser beam into the different stages represents one of the key issues. To limit the spatial foot print and thus to realize a high overall acceleration gradient, a concept has to be found which realizes this in-coupling within a few centimeters (cf. Fig 1). The fluence of the laser pulse several centimeters away from the acceleration stage (focus) exceeds the damage threshold of any available mirror coating. Therefore, in reference [2] a plasma mirror was suggested for this purpose. We present experiments on a tape-drive based plasma mirror which could be used to reflect the focused laser beam into the acceleration stage. Plasma mirrors composed of antireflection coated glass substrates are usually used to improve the temporal laser contrast of laser pulses by several orders of magnitudes [3,4]. This is particularly important for laser interaction with solid matter, such as ion acceleration [5,6] and high harmonic generation on surfaces [7]. Therefore, the laser pulse is weekly focused onto a substrate. The main pulse generates a plasma and is reflected at the critical surface, whereas the low intensity pre-pulse (mainly the Amplified Spontaneous Emission pedestal) will be transmitted through the substrate before the mirror has been triggered. Several publications [3,4] demonstrate a conservation of the spatial beam quality and a reflectivity of about 70 %. The drawback of this technique is the limited repetition rate since for every shot a fresh surface has to be provided. In the past years several novel approaches for high repetition rate plasma mirrors have been developed [2, 8]. Nevertheless, for the staged accelerator scheme a second important requirement has to be considered. Since the electron beam has to propagate through the mirror, the thickness of the substrate has to be as thin as possible to reduce the distortion of the electron beam. A tape of only several micrometer thickness can overcome these disadvantages. It can be used with a sufficient repetition rate while it allows the electron beam to propagate through with a minimum of scattering.

43 PARTICLE ACCELERATORS↗

INTERNAL STRUCTURE OF PROTOCLUSTER GALAXIES: ACCELERATED STRUCTURAL EVOLUTION IN OVERDENSE ENVIRONMENTS?

We present a high spatial resolution Hubble Space Telescope/NICMOS imaging survey in the field of a known protocluster surrounding the powerful radio galaxy MRC1138-262 at z = 2.16. Previously, we have shown that this field exhibits a substantial surface overdensity of red J-H galaxies. Here we focus on the stellar masses and galaxy effective radii in an effort to compare and contrast the properties of likely protocluster galaxies with their field counterparts and to look for correlations between galaxy structure and (projected) distance relative to the radio galaxy. We find a hint that quiescent, cluster galaxies are on average less dense than quiescent field galaxies of similar stellar mass and redshift. In fact, we find that only two (of eight) quiescent protocluster galaxies are of similar density to the majority of the massive, quiescent compact galaxies (Semi-Evolved Elephantine Dense galaxies; SEEDs) found in several field surveys. Furthermore, there is some indication that the structural Sersic n parameter is higher (n {approx} 3-4) on average for cluster galaxies compared to the field SEEDs (n {approx} 1-2). This result may imply that the accelerated galaxy evolution expected (and observed) in overdense regions also extends to structural evolution presuming that massive galaxies began as dense (low n) SEEDs and have already evolved to be more in line with local galaxies of the same stellar mass.

79 ASTRONOMY AND ASTROPHYSICS↗

EVOLUTION OF HARD X-RAY SOURCES AND ULTRAVIOLET SOLAR FLARE RIBBONS FOR A CONFINED ERUPTION OF A MAGNETIC FLUX ROPE

We study the magnetic field structures of hard X-ray (HXR) sources and flare ribbons of the M1.1 flare in active region NOAA 10767 on 2005 May 27. We have found in a nonlinear force-free field extrapolation over the same polarity inversion line, a small pre-eruptive magnetic flux rope located next to sheared magnetic arcades. RHESSI and the Transition Region and Coronal Explorer (TRACE) observed this confined flare in the X-ray bands and ultraviolet (UV) 1600 A bands, respectively. In this event magnetic reconnection occurred at several locations. It first started at the location of the pre-eruptive flux rope. Then, the observations indicate that magnetic reconnection occurred between the pre-eruptive magnetic flux rope and the sheared magnetic arcades more than 10 minutes before the flare peak. This implies the formation of the larger flux rope, as observed with TRACE. Next, HXR sources appeared at the footpoints of this larger flux rope at the peak of the flare. The associated high-energy particles may have been accelerated below the flux rope in or around a reconnection region. Still, the close spatial association between the HXR sources and the flux rope footpoints favors an acceleration within the flux rope. Finally, a topological analysis of a large solar region, including active regions NOAA 10766 and 10767, shows the existence of large-scale Quasi-Separatrix Layers (QSLs) before the eruption of the flux rope. No enhanced emission was found at these QSLs during the flare, but the UV flare ribbons stopped at the border of the closest large-scale QSL.

79 ASTRONOMY AND ASTROPHYSICS↗

Escape of Flare-Accelerated Particles in Solar Eruptive Events

Impulsive solar energetic particle events are widely believed to be due to the prompt escape into the interplanetary medium of flare-accelerated particles produced by solar eruptive events. According to the standard model for such events, however, particles accelerated by the flare reconnection should remain trapped in the flux rope comprising the coronal mass ejection. The particles should reach the Earth only much later, along with the bulk ejecta. To resolve this paradox, we have extended our previous axisymmetric model for the escape of flare-accelerated particles to fully three-dimentional (3D) geometries. We report the results of magnetohydrodynamic simluations of a coronal system that consists of a bipolar active region embedded in a background global dipole field structured by solar wind. our simulations show that multiple magnetic reconnection episodes occur prior to and during the coronal mass ejection 9CME) eruption and its interplanetary propagation. In addition to the episodes that build up the flux rope, reconnection between the open field and the CME couples the closed coronal to the open interplanetary field. Flare-accelerated particles initially trapped in the CME thereby gain access to the open interplanetary field along a trail blazed by magnetic reconnection. A key difference between these 3D results and our previous calculations is that the interchange reconnection allows accelerated particles to escape from deep within the CME flux rope. We estimate the spatial extent of the particle-escape channels. The relative timings between flare acceleration and release of the energetic particles through CME/open-field coupling are also determined. All our results compare favorably with observations.

Masson, S.↗

The trends high-contrast imaging survey. IV. The occurrence rate of giant planets around M dwarfs

Doppler-based planet surveys have discovered numerous giant planets but are incomplete beyond several AU. At larger star-planet separations, direct planet detection through high-contrast imaging has proven successful, but this technique is sensitive only to young planets and characterization relies upon theoretical evolution models. Here we demonstrate that radial velocity measurements and high-contrast imaging can be combined to overcome these issues. The presence of widely separated companions can be deduced by identifying an acceleration (long-term trend) in the radial velocity of a star. By obtaining high spatial resolution follow-up imaging observations, we rule out scenarios in which such accelerations are caused by stellar binary companions with high statistical confidence. We report results from an analysis of Doppler measurements of a sample of 111 M-dwarf stars with a median of 29 radial velocity observations over a median time baseline of 11.8 yr. By targeting stars that exhibit a radial velocity acceleration ({sup t}rend{sup )} with adaptive optics imaging, we determine that 6.5% ± 3.0% of M-dwarf stars host one or more massive companions with 1 < m/M{sub J} < 13 and 0 < a < 20 AU. These results are lower than analyses of the planet occurrence rate around higher-mass stars. We find the giant planet occurrence rate is described by a double power law in stellar mass M and metallicity F ≡ [Fe/H] such that f(M,F)=0.039{sub −0.028}{sup +0.056}M{sup 0.8{sub −}{sub 0}{sub .}{sub 9}{sup +{sup 1{sup .{sup 1}}}}}10{sup (3.8±1.2)F}. Our results are consistent with gravitational microlensing measurements of the planet occurrence rate; this study represents the first model-independent comparison with microlensing observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

NON-STANDARD ENERGY SPECTRA OF SHOCK-ACCELERATED SOLAR PARTICLES

We consider a numerical model for the shock acceleration of energetic ions in the magnetic environment of the solar corona. The model is motivated by observations of the deka-to-hecto-MeV proton energy spectra, ion and electron timing, and abundances in the beginning of major solar energetic particle (SEP) events, prior to the event's main phase associated with coronal mass ejection (CME) driven shock in the solar wind. Inasmuch as the obliquity of the CME-liftoff-associated shocks in solar corona and hence the seed-particle supply for the shock acceleration are essentially time dependent, a steady state energy spectrum of accelerated protons near the shock could not be attained. Energy spectrum of the SEP emission depends on the spatial and energy distribution of seed particles for the coronal shock acceleration, on the shock wave history, and on the location and scenario of the energetic particle escape into the interplanetary medium. We use a numerical model of the shock acceleration on a semicircular magnetic field line to learn a significance of different effects. If the shock geometry in a particular magnetic tube changes from nearly parallel to perpendicular, the resulting SEP spectrum in most distant sections of the tube, e.g., at the top of a transequatorial loop, resembles a wide beam, which is very different from the standard power-law spectrum that would be expected in a steady state. Possible escape of the shock-accelerated particles from more than one coronal location, stochastic re-acceleration, and the magnetic tube expansion can make the SEP spectra even more complicated.

79 ASTRONOMY AND ASTROPHYSICS↗

A HIGH REPETITION PLASMA MIRROR FOR STAGED ELECTRON ACCELERATION

In order to build a compact, staged laser plasma accelerator the in-coupling of the laser beam to the different stages represents one of the key issues. To limit the spatial foot print and thus to realize a high overall acceleration gradient, a concept has to be found which realizes this in-coupling within a few centimeters. We present experiments on a tape-drive based plasma mirror which could be used to reflect the focused laser beam into the acceleration stage.

43 PARTICLE ACCELERATORS↗

Growth factor parametrization in curved space

The growth rate of matter perturbation and the expansion rate of the Universe can be used to distinguish modified gravity and dark energy models in explaining cosmic acceleration. We explore here the inclusion of spatial curvature into the growth factor. We expand previous results using the approximation {omega}{sub m}{sup {gamma}} and then suggest a new form, f{sub a}={omega}{sub m}{sup {gamma}}+({gamma}-4/7){omega}{sub k}, as an approximation for the growth factor when the curvature {omega}{sub k} is not negligible, and where the growth index {gamma} is usually model dependent. The expression recovers the standard results for the curved and flat {lambda}CDM and Dvali-Gabadadze-Porrati models. Using the best fit values of {omega}{sub m0} and {omega}{sub k0} to the expansion/distance measurements from Type Ia SNe, baryon acoustic oscillation, WMAP5, and H(z) data, we fit the growth index parameter to current growth factor data and obtain {gamma}{sub {lambda}}({omega}{sub k}{ne}0)=0.65{sub -0.15}{sup +0.17} and {gamma}{sub DGP}({omega}{sub k}{ne}0)=0.53{sub -0.12}{sup +0.14}. For the {lambda}CDM model, the 1-{sigma} observational bounds are found consistent with theoretical value, unlike the case for the Dvali-Gabadadze-Porrati model. We also find that the current data we used is not enough to put significant constraints when the 3 parameters in f{sub a} are fit simultaneously. Importantly, we find that, in the presence of curvature, the analytical expression proposed for f{sub a} provides a better fit to the growth factor than other forms and should be useful for future high precision missions and studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

JEMMRLA - Electron Model of a Muon RLA with Multi-pass Arcs

We propose a demonstration experiment for a new concept of a &#x27;dogbone&#x27; RLA with multi-pass return arcs -- JEMMRLA (Jlab Electron Model of Muon RLA). Such an RLA with linear-field multi-pass arcs was introduced for rapid acceleration of muons for the next generation of Muon Facilities. It allows for efficient use of expensive RF while the multi-pass arc design based on linear combined-function magnets exhibits a number of advantages over separate-arc or pulsed-arc designs. Here we describe a test of this concept by scaling a GeV scale muon design for electrons. Scaling muon momenta by the muon-to-electron mass ratio leads to a scheme, in which a 4.5 MeV electron beam is injected in the middle of a 3 MeV/pass linac with two double-pass return arcs and is accelerated to 18 MeV in 4.5 passes. All spatial dimensions including the orbit distortion are scaled by a factor of 7.5, which arises from scaling the 200 MHz muon RF to a readily available 1.5 GHz. The hardware requirements are not very demanding making it straightforward to implement. Such an RLA may have applications going beyond muon acceleration: in medical isotope production, radiation cancer therapy and homeland security.

43 PARTICLE ACCELERATORS↗

The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

The balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approximately 20 keV to greater than approximately 10 MeV. GRIPS will address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution of less than 0.1 cubic millimeter. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-centimeter thick tungsten alloy slit/slat grid with pitches that range quasi-continuously from 1 to 13 millimeters. The MPRM is situated 8 meters from the spectrometer to provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e., as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS is scheduled for a continental-US engineering test flight in fall 2013, followed by long or ultra-long duration balloon flights in Antarctica.

Shih, Albert Y.↗

A SYSTEMATIC STUDY OF THE THERMAL AND NONTHERMAL EMISSION IN THE SUPERNOVA REMNANT RCW 86 WITH SUZAKU

Diffusive shock acceleration by the shockwaves in supernova remnants (SNRs) is widely accepted as the dominant source for Galactic cosmic rays. However, it is unknown what determines the maximum energy of accelerated particles. The surrounding environment could be one of the key parameters. The SNR RCW 86 shows both thermal and nonthermal X-ray emission with different spatial morphologies. These emission originate from the shock-heated plasma and accelerated electrons respectively, and their intensities reflect their density distributions. Thus, the remnant provides a suitable laboratory to test possible association between the acceleration efficiency and the environment. In this paper, we present results of spatially resolved spectroscopy of the entire remnant with Suzaku . The spacially resolved spectra are well reproduced with a combination of a power-law for synchrotron emission and a two-component optically thin thermal plasma, corresponding to the shocked interstellar medium (ISM) with kT of 0.3–0.6 keV and Fe-dominated ejecta. It is discovered that the photon index of the nonthermal component becomes smaller when decreasing the emission measure of the shocked ISM, where the shock speed has remained high. This result implies that the maximum energy of accelerated electrons in RCW 86 is higher in the low-density and higher shock speed regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Emerging hierarchical dislocation structures: Insights from scanning electron microscopy-electron backscatter diffraction in situ tensile testing and multifractal analysis

Understanding the evolution of dislocation structures during plastic deformation is critical for predicting the mechanical performance of metallic materials. In this work, we applied in situ scanning electron microscopy/electron backscatter diffraction tensile testing combined with multifractal (MF) analysis to assess deformation-induced dislocation structure evolution in solution-annealed 304 L stainless steel, both in its as-received and neutron-irradiated states (5.4 displacements per atom). The analysis of kernel average misorientation patterns revealed the formation of hierarchical dislocation arrangements that exhibit clear MF scaling behavior. Despite pronounced visual differences between nonirradiated and irradiated specimens—most notably, the appearance of dislocation channels after irradiation—the singularity spectra suggest that both conditions give rise to similar underlying hierarchical structures. MF analysis provides a quantitative measure of the spatial complexity and self-organization of dislocation patterns, highlighting the accelerated emergence and evolution of the dislocation structures in irradiated polycrystalline materials, as well as the limitation of their spatial extent. The findings indicate that irradiation not only modifies microstructure but also alters correlation-driven dislocation organization. More generally, they demonstrate that MF analysis is a powerful tool for probing mesoscale deformation mechanisms.

Dislocation structures↗

Accelerating iterative ptychography with an integrated neural network

Electron ptychography is a powerful and versatile tool for high-resolution and dose-efficient imaging. Iterative reconstruction algorithms are powerful but also computationally expensive due to their relative complexity and the many hyperparameters that must be optimised. Gradient descent-based iterative ptychography is a popular method, but it may converge slowly when reconstructing low spatial frequencies. Here, in this work, we present a method for accelerating a gradient descent-based iterative reconstruction algorithm by training a neural network (NN) that is applied in the reconstruction loop. The NN works in Fourier space and selectively boosts low spatial frequencies, thus enabling faster convergence in a manner similar to accelerated gradient descent algorithms. We discuss the difficulties that arise when incorporating a NN into an iterative reconstruction algorithm and show how they can be overcome with iterative training. We apply our method to simulated and experimental data of gold nanoparticles on amorphous carbon and show that we can significantly speed up ptychographic reconstruction of the nanoparticles.

4DSTEM↗

Generation and manipulation of proton beams by ultra-short laser pulses

Applying a 21-channel Thomson spectrometer setup has revealed further insight to the connection between spatial and spectral beam characteristic of laser accelerated protons. Analyzing the central emission cone (plus/minus 3 degree) shows an increasing beam divergency for protons with increasing kinetic energies. This holds for protons emitted from the same source area at the target surface. The whole beam is a well ordered system with a clear functional dependence of trajectories on proton energy. This is a consequence of the source dynamics which is determined by the sheath development in time. Thus laser-driven ion beams can be advantageously manipulated for further propagation to an experiment. We demonstrate this capability with a magnetic quadrupole and obtain a nearly parallel and monochromatized beam. Furthermore we set our achievements in beam production efficiency into context with other laser systems and demonstrate the potential of very-thin target foils.

43 PARTICLE ACCELERATORS↗