Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial data visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-I-41: Non-Cartesian MR Image Reconstruction with Integrated Gradient Non-Linearity Correction

Purpose: Nonlinearities in the spatial encoding gradients of MRI systems cause geometric distortion in images. Typically, this is retrospectively corrected via image-domain interpolation (a.k.a., “gradwarp”) albeit with a loss of spatial resolution. For non-Cartesian MRI, the latter problem is exaggerated by noise and undersampling artifact. In this study, we describe a novel correction strategy that accounts for gradient nonlinearities during — rather than after — non-Cartesian MRI reconstruction, and demonstrate that this approach mitigates the resolution loss that can occur with standard methods. Methods: To test the proposed method, the American College of Radiology (ACR) quality control phantom was scanned on at 1.5 T (General Electric, v16.0, “zoom” gradient) using a 1.6x undersampled 3D non- Cartesian Shells trajectory (GRE, FOV=24 cm3, 120 shells, 16552 shots, 512 readout, matrix=2403). Image reconstruction was first performed via standard k-space density-compensated gridding and retrospectively corrected via cubic spline interpolation. Image reconstruction was then separately performed using a k-space and image-domain densitycompensated type-3 non-uniform fast Fourier transform (NUFFT), which provides a direct mapping between non-Cartesian k-space samples and warped image space voxel locations. Thus, no separate distortion correction procedure is needed for the proposed approach. The gradient distortion field was determined using vendor provided calibration data. Results: Phantom scan results show that both processing approaches successfully correct geometric distortion. However, visual inspection of the ACR phantom spatial resolution inserts shows that the proposed strategy preserves the resolution of the nominal (uncorrected) reconstruction while “gradwarp” imparts marked spatial blurring (especially for the 1.0 and 1.1 mm inserts) and thus resolution loss. Conclusion: We've presented a novel reconstruction strategy for non-Cartesian MRI that corrects for gradient nonlinearities during — rather than after — reconstruction, and thus better preserves image resolution than traditional interpolation-based methods. This approach is expected to be especially advantageous when imaging with non-standard magnet geometries. NIH RR018898; NIH EB10065.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Earth Science Multimedia Theater

The presentation will begin with the latest 1998 NASA Earth Science Vision for the next 25 years. A compilation of the 10 days of animations of Hurricane Georges which were supplied daily on NASA to Network television will be shown. NASA's visualizations of Hurricane Bonnie which appeared in the Sept 7 1998 issue of TIME magazine. Highlights will be shown from the NASA hurricane visualization resource video tape that has been used repeatedly this season on network TV. Results will be presented from a new paper on automatic wind measurements in Hurricane Luis from 1 -min GOES images that will appear in the October BAMS. The visualizations are produced by the Goddard Visualization & Analysis Laboratory, and Scientific Visualization Studio, as well as other Goddard and NASA groups using NASA, NOAA, ESA, and NASDA Earth science datasets. Visualizations will be shown from the "Digital-HyperRes-Panorama" Earth Science ETheater'98 recently presented in Tokyo, Paris and Phoenix. The presentation in Paris used a SGI/CRAY Onyx Infinite Reality Super Graphics Workstation at 2560 X 1024 resolution with dual synchronized video Epson 71 00 projectors on a 20ft wide screen. Earth Science Electronic Theater '999 is being prepared for a December 1 st showing at NASA HQ in Washington and January presentation at the AMS meetings in Dallas. The 1999 version of the Etheater will be triple wide with at resolution of 3840 X 1024 on a 60 ft wide screen. Visualizations will also be featured from the new Earth Today Exhibit which was opened by Vice President Gore on July 2, 1998 at the Smithsonian Air & Space Museum in Washington, as well as those presented for possible use at the American Museum of Natural History (NYC), Disney EPCOT, and other venues. New methods are demonstrated for visualizing, interpreting, comparing, organizing and analyzing immense Hyperimage remote sensing datasets and three dimensional numerical model results. We call the data from many new Earth sensing satellites, Hyperimage datasets, because they have such high resolution in the spectral, temporal, spatial, and dynamic range domains. The traditional numerical spreadsheet paradigm has been extended to develop a scientific visualization approach for processing Hyperimage datasets and 3D model results interactively. The advantages of extending the powerful spreadsheet style of computation to multiple sets of images and organizing image processing were demonstrated using the Distributed Image SpreadSheet (DISS).

Hasler, A. F.↗

Scalable Volume Visualization for Big Scientific Data Modeled by Functional Approximation

Considering the challenges posed by the space and time complexities in handling extensive scientific volumetric data, various data representations have been developed for the analysis of large-scale scientific data. Multivariate functional approximation (MFA) is an innovative data model designed to tackle substantial challenges in scientific data analysis. It computes values and derivatives with high-order accuracy throughout the spatial domain, mitigating artifacts associated with zero- or first-order interpolation. However, the slow query time through MFA makes it less suitable for interactively visualizing a large MFA model. In this work, we develop the first scalable interactive volume visualization pipeline, MFA-DVV, for the MFA model encoded from large-scale datasets. Our method achieves low input latency through distributed architecture, and its performance can be further enhanced by utilizing a compressed MFA model while still maintaining a high-quality rendering result for scientific datasets. We conduct comprehensive experiments to show that MFA-DVV can decrease the input latency and achieve superior visualization results for big scientific data compared with existing approaches.

big scientific dataset↗

TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-03: Advances in CBCT for Orhtopaedics and Bone Health Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

Uniformity and volume-representativity of consecutive submillimetre wafers of shale for SANS and USANS investigations

(Ultra) Small Angle Neutron Scattering (SANS/USANS) is a non-destructive technique suitable for characterization of porous structures from nano- to micro-pore size (1 nm to 20 μm), which has been widely used to characterize accessible and inaccessible porosity in tight unconventional hydrocarbon reservoirs (e.g., shales). Here, in this study, SANS and USANS are used to examine the degree of nano- to micropore uniformity of the rock body on sub-millimetre to centimetre scale. This study presents a test of the hypothesis of volume representativity of pore structure information measured by SANS and USANS for shale wafers (0.22–1 mm) cut from six North American unconventional shale cores of different maturities (New Albany Shale and Marcellus Shale). Experimental reproducibility of USANS is further investigated for two wafers measured using various acquisition times. All samples show that fluctuations of the relative intensity generally decrease from the USANS Q-range (pore size from around 200 nm to 20 μm) to most of the SANS Q-range (pore size from around 5 nm to 700 nm), and peaks in the SANS large-Q region (for pores smaller than about 5 nm). There is a positive correlation between the spatial fluctuation of the relative SANS intensity and the scattering power of shales. In addition, the scattering intensity and its fluctuations is larger for the less mature shale cores. Shale is known to be highly heterogenous and the hypothesis of uniformity does not apply at sub-millimetre scale even for samples that appear homogeneous at visual inspection. This study presents an approach to minimise the variation through sample selection, data interpretation methodology and instrumental reproducibility tests. The best values of the microstructural spatial uniformity for the apparently homogeneous sections of a core (i.e., the SANS and USANS intensity variation) is less than ±10%.

01 COAL, LIGNITE, AND PEAT↗

High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mars: Correcting surface albedo observations for effects of atmospheric dust loading

We have developed a radiative transfer model which allows the effects of atmospheric dust loading on surface albedo to be investigated. This model incorporates atmospheric dust opacity, the single scattering albedo and particle phase function of atmospheric dust, the bidirectional reflectance of the surface, and variable lighting and viewing geometry. The most recent dust particle properties are utilized. The spatial and temporal variability of atmospheric opacity (Tan) strongly influences the radiative transfer modelling results. We are currently using the approach described to determine Tan for IRTM mapping sequences of selected regions. This approach allows Tan to be determined at the highest spatial and temporal resolution supported by the IRTM data. Applying the radiative transfer modelling and determination of Tan described, IRTM visual brightness observations can be corrected for the effects of atmospheric dust loading a variety of locations and times. This approach allows maps of 'dust-corrected surface albedo' to be constructed for selected regions. Information on the variability of surface albedo and the amount of dust deposition/erosion related to such variability results. To date, this study indicates that atmospheric dust loading has a significant effect on observations of surface albedo, amounting to albedo corrections of as much as several tens of percent. This correction is not constant or linear, but depends upon surface albedo, viewing and lighting geometry, the dust and surface phase functions, and the atmospheric opacity. It is clear that the quantitative study of surface albedo, especially where small variations in observed albedo are important (such as photometric analyses), needs to account for the effects of the atmospheric dust loading. Maps of 'dust-corrected surface albedo' will be presented for a number of regions.

Lee, S. W.↗

The NASA NEESPI Data Portal to Support Studies of Climate and Environmental Changes in Non-Boreal Europe

NASA NEESPI (Northern Eurasia Earth Science Partnership Initiative) data portal is a NASA funded project that focuses on collecting satellite remote sensing data, providing tools, information, and services in support of NEESPI scientific objectives (Leptoukh, et al., 2007). The data can be accessed online through anonymous ftp, through an advanced data searching and ordering system Mirador that uses keywords to find data quickly in a Google-like interface, and through the Goddard Interactive Online Visualization ANd aNalysis Infrastructure (Giovanni). The portal provides preprocessed data from different satellite sensors and numerical models to the same spatial and temporal resolution and the same projection so that the data can be used easily to perform inter-comparison or relationship studies. In addition, it provides parameter and spatially subsetted data for regional studies. Studies of regional carbon, hydrology, aerosols in non-boreal Europe and their interactions with global climate are very challenging research topics. The NASA NEESPI data portal makes many satellite data available for such studies, including information on land cover types, fire, vegetation index, aerosols, land surface temperature, soil moisture, precipitation, snow/ice, and other parameters. This paper will introduce the features and products available in the system, focusing on the online data 1 tool, Giovanni NEESPI. An example that explores different data through Giovanni NEESPI in temperate region of non-boreal Europe will be presented.

Shen, Suhung↗

Visual detection of spatial contrast patterns: evaluation of five simple models

The ModelFest Phase One dataset is a collection of luminance contrast thresholds for 43 two-dimensional monochromatic spatial patterns confined to an area of approximately two by two degrees. These data were collected by a collaboration among twelve laboratories, and were designed to provide a common database for calibration and testing of spatial vision models. Here I report fits of the ModelFest data with five models: Peak Contrast, Contrast Energy, Generalized Energy, a Gabor Channels model, and a Discrete Cosine Transform model. The Gabor Channels model provides the best fit, though the other, simpler models, with the exception of Peak Contrast, provide remarkably good fits as well. Though there are clear individual differences, regularities in the data suggest the possibility of constructing a standard observer for spatial vision. c2000 Optical Society of America.

NASA Discipline Space Human Factors↗

Mixed Initiative Visual Analytics Using Task-Driven Recommendations

Visual data analysis is composed of a collection of cognitive actions and tasks to decompose, internalize, and recombine data to produce knowledge and insight. Visual analytic tools provide interactive visual interfaces to data to support tasks involved in discovery and sensemaking, including forming hypotheses, asking questions, and evaluating and organizing evidence. Myriad analytic models can be incorporated into visual analytic systems, at the cost of increasing complexity in the analytic discourse between user and system. Techniques exist to increase the usability of interacting with such analytic models, such as inferring data models from user interactions to steer the underlying models of the system via semantic interaction, shielding users from having to do so explicitly. Such approaches are often also referred to as mixed-initiative systems. Researchers studying the sensemaking process have called for development of tools that facilitate analytic sensemaking through a combination of human and automated activities. However, design guidelines do not exist for mixed-initiative visual analytic systems to support iterative sensemaking. In this paper, we present a candidate set of design guidelines and introduce the Active Data Environment (ADE) prototype, a spatial workspace supporting the analytic process via task recommendations invoked by inferences on user interactions within the workspace. ADE recommends data and relationships based on a task model, enabling users to co-reason with the system about their data in a single, spatial workspace. This paper provides an illustrative use case, a technical description of ADE, and a discussion of the strengths and limitations of the approach.

active data↗

Integrated Monitoring of Macroalgae Farms Using Acoustics and UUV Sensing

The vision of this project was to develop an integrated system for autonomous underwater vehicle (AUV) monitoring of offshore kelp farms using acoustic, environmental, and optical sensors. This project supports the overall MARINER goals of developing an offshore kelp aquaculture industry to produce low-carbon or carbon-neutral biofuels. The project commenced in the spring of 2018 and used laboratory experiments to test the efficacy of acoustic sensors for monitoring kelp farm lines and growing kelp biomass. Sensors were then integrated onto two AUVs as well as an autonomous surface vehicle in order to establish the optimal type, price point, and vehicle to most efficiently monitor kelp farm structures, kelp biomass, and the surrounding environment. Multiple field deployments of these vehicles and sensors in Massachusetts, New Hampshire, and Maine confirmed that farm lines and kelp could be visualized and that monitoring the spatial patterns of environmental variables was possible. The COVID-19 pandemic severely limited fieldwork activities and laboratory testing, with deployments around kelp farms not occurring again until January 2021. Time spent away from the field focused on data visualization and the development of a low-cost, vessel-based sensor system. Unfortunately, the low-cost system experienced a disk failure during its first deployment and due to multiple resignations from the project team further engineering and development was not possible. Additionally, final results from acoustic sensor testing in 2021 were also not able to be completed due to the resignation of the postdoc leading the analysis. Despite these setbacks, multiple avenues for further development of optical imagery processing from the 360-degree Kelpcam camera and testing of the low-cost sensor system may be possible.

09 BIOMASS FUELS↗

Modeling and Visualizing Uncertainty in Continuous Variables Predicted using Remotely Sensed Data

The use of remotely sensed images to map continuous biophysical variables, such as those related to terrestrial vegetation amount, sea surface temperature, and many other targets of NASA s Earth Observing System (EOS), includes variable, parametric, positional, spatial support and structural sources of uncertainty. A complete description of uncertainty will lead to a probability distribution at each location, allowing the exploration of the spatial dimension of uncertainty, that is, where the field is not well quantified. To achieve this purpose, convenient visualization tools are required. We have produced such a tool, called PDFVis, that facilitates the display of probability density functions (pdfs) on a per-grid-cell basis. The density estimate from Monte-Carlo generated realizations is interactively displayed as well as parametric and non-parametric summaries of the pdf field (such as mean, median, quartiles, standard deviation, number of modes, and locations of modes). Shaded surface renderings of pdfs along a transect can also be projected onto a plane. This tool will become more useful as richer descriptions of spatial uncertainty become available.

Dungan, Jennifer L.↗

MO-DE-207A-01: Impact of Statistical Weights On Detection of Low-Contrast Details in Model-Based Iterative CT Reconstruction

Purpose: Penalized-weighted least-square reconstruction has become an important research topic in CT, to reduce dose without affecting image quality. Two components impact image quality in this reconstruction: the statistical weights and the use of an edge-preserving penalty term. We are interested in assessing the influence of statistical weights on their own, without the edge-preserving feature. Methods: The influence of statistical weights on image quality was assessed in terms of low-contrast detail detection using LROC analysis. The task amounted to detect and localize a 6-mm lesion with random contrast inside the FORBILD head phantom. A two-alternative forced-choice experiment was used with two human observers performing the task. Reconstructions without and with statistical weights were compared, both using the same quadratic penalty term. The beam energy was set to 30keV to amplify spatial differences in attenuation and thereby the role of statistical weights. A fan-beam data acquisition geometry was used. Results: Visual inspection of images clearly showed a difference in noise between the two reconstructions methods. As expected, the reconstruction without statistical weights exhibited noise streaks. The other reconstruction appeared better in this aspect, but presented other disturbing noise patterns and artifacts induced by the weights. The LROC analysis yield the following 95-percent confidence interval for the difference in reader-averaged AUC (reconstruction without weights minus reconstruction with weights): [0.0026,0.0599]. The mean AUC value was 0.9094. Conclusion: We have investigated the impact of statistical weights without the use of edge-preserving penalty in penalized weighted least-square reconstruction. A decrease rather than increase in image quality was observed when using statistical weights. Thus, the observers were better able to cope with the noise streaks than the noise patterns and artifacts induced by the statistical weights. It may be that different results would be obtained if the penalty term was used with a pixel-dependent weight. F Noo receives research support from Siemens Healthcare GmbH.

60 APPLIED LIFE SCIENCES↗

Big Data as a Service from an Urban Information System

Big Data has already proven itself as a valuable tool that lets geographers and urban researchers utilize large data re- sources to generate new insights. However, wider adoption of Big Data techniques in these areas is impeded by a number of difficulties in both knowledge discovery and data and sci- ence production. Typically users face such problems as dis- parate and scattered data, data management, spatial search- ing, insufficient computational capacity for data-driven anal- ysis and modelling, and the lack of tools to quickly visual- ize and summarize large data and analysis results. Here we propose an architecture for an Urban Information Sys- tem (UrbIS) that mitigates these problems by utilizing the Big Data as a Service (BDaaS) concept. With technolog- ical roots in High-performance Computing (HPC), BDaaS is based on the idea of outsourcing computations to dif- ferent computing paradigms, scalable to super-computers. UrbIS aims to incorporate federated metadata search, in- tegrated modeling and analysis, and geovisualization into a single seamless workflow. The system is under active devel- opment and is built around various emerging technologies that include hybrid and NoSQL databases, massively par- allel systems, GPGPU computing, and WebGL-based geo- graphic visualization. UrbIS is designed to facilitate using Big Data across multiple cities to better understand how ur- ban areas impact the environment and how climate change and other environmental change impact urban areas.

Sorokine, Alexandre↗

Resampling study

The author has identified the following significant results. The nearest neighbor and cubic convolution resampling algorithms were applied to a variety of images extracted from LANDSAT MSS data. A comparison of the results demonstrated that (1) cubic convolution can cause spreading of small features and can introduce noticeable overshoot (ringing) into the data; (2) cubic convolution attenuates the high spatial frequencies compared to the original and nearest neighbor resampled data; and (3) cubic convolution generally produces photographic products of superior visual quality. The effects of the resampling algorithms on multispectral classification were not conclusively determined due to the small number of images tested.

Ferneyhough, D. G.↗

Anaysis of the quality of image data required by the LANDSAT-4 Thematic Mapper and Multispectral Scanner

The spatial, geometric, and radiometric qualities of LANDSAT 4 thematic mapper (TM) and multispectral scanner (MSS) data were evaluated by interpreting, through visual and computer means, film and digital products for selected agricultural and forest cover types in California. Multispectral analyses employing Bayesian maximum likelihood, discrete relaxation, and unsupervised clustering algorithms were used to compare the usefulness of TM and MSS data for discriminating individual cover types. Some of the significant results are as follows: (1) for maximizing the interpretability of agricultural and forest resources, TM color composites should contain spectral bands in the visible, near-reflectance infrared, and middle-reflectance infrared regions, namely TM 4 and TM % and must contain TM 4 in all cases even at the expense of excluding TM 5; (2) using enlarged TM film products, planimetric accuracy of mapped poins was within 91 meters (RMSE east) and 117 meters (RMSE north); (3) using TM digital products, planimetric accuracy of mapped points was within 12.0 meters (RMSE east) and 13.7 meters (RMSE north); and (4) applying a contextual classification algorithm to TM data provided classification accuracies competitive with Bayesian maximum likelihood.

Colwell, R. N.↗

Design and test of an object-oriented GIS to map plant species in the Southern Rockies

Elevational and latitudinal shifts occur in the flora of the Rocky Mountains due to long term climate change. In order to specify which species are successfully migrating with these changes, and which are not, an object-oriented, image-based geographic information system (GIS) is being created to animate evolving ecological regimes of temperature and precipitation. Research at the Earth Data Analysis Center (EDAC) is developing a landscape model that includes the spatial, spectral and temporal domains. It is designed to visualize migratory changes in the Rocky Mountain flora, and to specify future community compositions. The object-oriented database will eventually tag each of the nearly 6000 species with a unique hue, intensity, and saturation value, so their movements can be individually traced. An associated GIS includes environmental parameters that control the distribution of each species in the landscape, and satellite imagery is used to help visualize the terrain. Polygons for the GIS are delineated as landform facets that are static in ecological time. The model manages these facets as a triangular irregular net (TIN), and their analysis assesses the gradual progression of species as they migrate through the TIN. Using an appropriate climate change model, the goal will be to stop the modeling process to assess both the rate and direction of species' change and to specify the changing community composition of each landscape facet.

Morain, Stanley A.↗