Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Optimizing invader suppression to restore native species: Leveraging species traits to overcome collateral damage

Strategies to control ongoing biological invasions are often developed by modelling the invasive species' population and aiming to reduce its abundance. However, if the ultimate objective is to protect and restore native species, focussing solely on the invader may not be optimal because it does not account for (i) species interactions that can cause the invader's impacts to depend nonlinearly on its abundance, (ii) collateral damages to native species incurred due to nonspecific removal methods or (iii) native-invader trait differences. Here, to identify an invader suppression strategy that maximizes average native population size, we applied optimal control theory to a two-species model of a native species threatened by an invasive competitor. We examined trade-offs between iterative physical removals that selectively target invaders and intensifiable chemical control that is nonselective but has higher efficacy. We found that while iterative removals were capable of supporting large native populations when applied continuously, cost could be prohibitively high. In contrast, when favourable native-invader trait differences enabled native species to re-establish more quickly than invaders, intensifiable methods could achieve substantial restoration benefits at lower cost by focussing removal effort into periodic, high-efficacy events. In a metapopulation, removals that rotated among spatial patches were optimal when the native species had higher dispersal, whereas synchronous removals were preferred when native recovery was initiated locally and the invader could disperse. For a case study in Hawaiian streams, we compared how effective two alternative methods of removing invasive live-bearing fishes (poeciliids) might be at restoring the endemic freshwater goby Sicyopterus stimpsoni. We found that rotenone (a piscicidal chemical) offered superior benefits when the control budget was small and efficacy was high, but that electrofishing (use of electricity to manually collect target fish) was better with larger budgets and in many lower-efficacy scenarios. Synthesis and applications. Our findings demonstrate that, by accounting for species interactions and collateral damage, invasive species control strategies can be optimized in light of species traits. Choices about the timing, locations and types of removal events present opportunities to increase the efficiency with which invasive species suppression benefits native species.

54 ENVIRONMENTAL SCIENCES↗

Dynamic Imaging of Surface Motion with a Stereo Borescope

A new stereo borescope has been investigated that would provide a time-resolved calibrated method of recording the motion and deformation of a three-dimensional (3-D) surface during explosively driven dynamic shock experiments at the Nevada Test Site. In these experiments, geometries would likely prove to be incompatible with conventional direct optical systems. Single line-of-sight borescopes lack adequate depth-of-field for quantitative imaging of the 3-D surface. To improve depth-of-field and provide time resolution, a stereo borescope has been fabricated for use with a nine-frame framing camera. At one end, stereo optics couple light from the dynamic surface into a pair of flexible 1-mm-diameter correlated fiber-optic bundles. At the other end, small-format lenses (~3 mm) interface with the framing camera, which is set up to simultaneously record the separate-perspective views. All nine frames could be recorded in a period as short as 1.8 μs, and spatial resolution is optimized to 11 line-pairs per mm. To achieve pseudo 3-D depth perception, photogrammetric analysis has been demonstrated with commercial software from ADAM technology (Australia). This paper presents the results from time-resolved stereo images of dynamic surfaces collected in a series of high-explosives experiments at the National Security Technologies, LLC, “Boom Box” in Santa Barbara, CA. Experience with the stereo borescope has suggested other potentially useful stereoscopic applications, such as stereo viewing of moving surfaces on the interiors of engines and the heating of moving components, and the viewing material deposition on interior surfaces during machine operations and fabrication processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-based optimization of near-field binary-pixelated beam shapers

The optimization of components that rely on spatially dithered distributions of transparent or opaque pixels and an imaging system with far-field filtering for transmission control is demonstrated. The binary-pixel distribution can be iteratively optimized to lower an error function that takes into account the design transmission and the characteristics of the required far-field filter. Simulations using a design transmission chosen in the context of high-energy lasers show that the beam-fluence modulation at an image plane can be reduced by a factor of 2, leading to performance similar to using a non-optimized spatial-dithering algorithm with pixels of size reduced by a factor of 2 without the additional fabrication complexity or cost. The optimization process preserves the pixel distribution statistical properties. Analysis shows that the optimized pixel distribution starting from a high-noise distribution defined by a random-draw algorithm should be more resilient to fabrication errors than the optimized pixel distributions starting from a low-noise, error-diffusion algorithm, while leading to similar beamshaping performance. Furthermore, this is confirmed by experimental results obtained with various pixel distributions and induced fabrication errors.

43 PARTICLE ACCELERATORS↗

Loss factors associated with spatial and temporal tracking errors in intersatellite PPM communication links

The performance of an optical PPM intersatellite link in the presence of spatial and temporal tracking errors is investigated. It is shown that for a given rms spatial tracking error, an optimal transmitter beamwidth exists which minimizes the probability of bit error. The power penalty associated with the spatial tracking error when the transmitter beamwidth is adjusted to achieve optimal performance is shown to be large (greater than 9 dB) when the rms pointing jitter becomes a significant fraction (greater than 30 percent) of the diffraction limited beamwidth. The power penalty due to temporal tracking error, on the other hand, is relatively small (less than 0.1 dB) when the tracking loop bandwidth is less than 0.1 percent of the slot frequency. By properly allocating losses to spatial and temporal tracking errors, it is seen that a 10 to the -9th error rate can be achieved for a realistic link design with an approximately 3 dB signal power margin.

Chen, C. C.↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic microscopic imaging with an optically pumped magnetometer and flux guides

Here, by combining an optically pumped magnetometer (OPM) with flux guides (FGs) and by installing a sample platform on automated translation stages, we have implemented an ultra-sensitive FG-OPM scanning magnetic imaging system that is capable of detecting magnetic fields of ~20 pT with spatial resolution better than 300 μm (expected to reach ~10 pT sensitivity and ~100 μm spatial resolution with optimized FGs). As a demonstration of one possible application of the FG-OPM device, we conducted magnetic imaging of micron-size magnetic particles. Magnetic imaging of such particles, including nano-particles and clusters, is very important for many fields, especially for medical cancer diagnostics and biophysics applications. For rapid, precise magnetic imaging, we constructed an automatic scanning system, which holds and moves a target sample containing magnetic particles at a given stand-off distance from the FG tips. We show that the device was able to produce clear microscopic magnetic images of 10 μm-size magnetic particles. In addition, we also numerically investigated how the magnetic flux from a target sample at a given stand-off distance is transmitted to the OPM vapor cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compressive Neural Representations of Volumetric Scalar Fields

Here, we present an approach for compressing volumetric scalar fields using implicit neural representations. Our approach represents a scalar field as a learned function, wherein a neural network maps a point in the domain to an output scalar value. By setting the number of weights of the neural network to be smaller than the input size, we achieve compressed representations of scalar fields, thus framing compression as a type of function approximation. Combined with carefully quantizing network weights, we show that this approach yields highly compact representations that outperform state-of-the-art volume compression approaches. The conceptual simplicity of our approach enables a number of benefits, such as support for time-varying scalar fields, optimizing to preserve spatial gradients, and random-access field evaluation. We study the impact of network design choices on compression performance, highlighting how simple network architectures are effective for a broad range of volumes.

97 MATHEMATICS AND COMPUTING↗

An integrated 6 MV linear accelerator model from electron gun to dose in a water tank

Purpose: The details of a full simulation of an inline side-coupled 6 MV linear accelerator (linac) from the electron gun to the target are presented. Commissioning of the above simulation was performed by using the derived electron phase space at the target as an input into Monte Carlo studies of dose distributions within a water tank and matching the simulation results to measurement data. This work is motivated by linac-MR studies, where a validated full linac simulation is first required in order to perform future studies on linac performance in the presence of an external magnetic field. Methods: An electron gun was initially designed and optimized with a 2D finite difference program using Child's law. The electron gun simulation served as an input to a 6 MV linac waveguide simulation, which consisted of a 3D finite element radio-frequency field solution within the waveguide and electron trajectories determined from particle dynamics modeling. The electron gun design was constrained to match the cathode potential and electron gun current of a Varian 600C, while the linac waveguide was optimized to match the measured target current. Commissioning of the full simulation was performed by matching the simulated Monte Carlo dose distributions in a water tank to measured distributions. Results: The full linac simulation matched all the electrical measurements taken from a Varian 600C and the commissioning process lead to excellent agreements in the dose profile measurements. Greater than 99% of all points met a 1%/1mm acceptance criterion for all field sizes analyzed, with the exception of the largest 40x40 cm{sup 2} field for which 98% of all points met the 1%/1mm acceptance criterion and the depth dose curves matched measurement to within 1% deeper than 1.5 cm depth. The optimized energy and spatial intensity distributions, as given by the commissioning process, were determined to be non-Gaussian in form for the inline side-coupled 6 MV linac simulated. Conclusions: An integrated simulation of an inline side-coupled 6 MV linac has been completed and benchmarked matching all electrical and dosimetric measurements to high accuracy. The results showed non-Gaussian spatial intensity and energy distributions for the linac modeled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilizing Ontology Structures To Curate the DOE-NETL Carbon Storage Open Database

The specialized ontology for the Carbon Storage Open Database will enable more rapid assignment of appropriate symbology standards for visualization improvements, optimize topical and spatial tagging within keywords, and improve flexibility for utilization in existing data repositories such as EDX. This effort also aims to establish a foundation for utilization of ontologies for organization of other data related to geologic carbon storage in the future.

Martin, Abigail↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Airborne Imaging Spectrometer - An advanced concept instrument

The Airborne Imaging Spectrometer (AIS) is a multispectral infrared imaging instrument utilizing a 32- x 32-element mercury-cadmium-telluride detector array to achieve high spatial resolution. A novel optical design provides high spectral resolution, and, in conjunction with the 32-element spatial resolution, makes optimal use of the capabilities of the area array. The experiment requirements and the details of instrument design, implementation, and calibration are presented. The superior resolution, accuracy, and data acquisition rate of this sensor/instrument concept for reconnaissance and geophysical survey is detailed and plans for upgrading/improving the instrument and future applications of this design concept are discussed.

Labaw, C.↗

Airborne imaging spectrometer II - The optical design

The Airborne Imaging Spectrometer (AIS I) was a multispectral infrared imaging instrument utilizing a 32 x 32 element mercury-cadmium-telluride detector array. A novel optical design provided high spectral resolution and, in conjunction with the 32-element spatial resolution, made optimal use of the capabilities of the area array. The operational successes of this proof-of-concept instrument, coupled with advances in infrared detector array technology, have provided the impetus and opportunity to upgrade the instrument by replacing the sensor with a newly developed 64 x 64 detector. The original instrument configuration is reviewed, and the design considerations, limitations and trade-offs necessitated by the new detector are examined, particularly the near doubling of the field of view and the increase from 1024 to 4096 pixels per read-out frame.

La Baw, Clayton↗

A cost-effective intelligent robotic system with dual-arm dexterous coordination and real-time vision

Dexterous coordination of manipulators based on the use of redundant degrees of freedom, multiple sensors, and built-in robot intelligence represents a critical breakthrough in development of advanced manufacturing technology. A cost-effective approach for achieving this new generation of robotics has been made possible by the unprecedented growth of the latest microcomputer and network systems. The resulting flexible automation offers the opportunity to improve the product quality, increase the reliability of the manufacturing process, and augment the production procedures for optimizing the utilization of the robotic system. Moreover, the Advanced Robotic System (ARS) is modular in design and can be upgraded by closely following technological advancements as they occur in various fields. This approach to manufacturing automation enhances the financial justification and ensures the long-term profitability and most efficient implementation of robotic technology. The new system also addresses a broad spectrum of manufacturing demand and has the potential to address both complex jobs as well as highly labor-intensive tasks. The ARS prototype employs the decomposed optimization technique in spatial planning. This technique is implemented to the framework of the sensor-actuator network to establish the general-purpose geometric reasoning system. The development computer system is a multiple microcomputer network system, which provides the architecture for executing the modular network computing algorithms. The knowledge-based approach used in both the robot vision subsystem and the manipulation control subsystems results in the real-time image processing vision-based capability. The vision-based task environment analysis capability and the responsive motion capability are under the command of the local intelligence centers. An array of ultrasonic, proximity, and optoelectronic sensors is used for path planning. The ARS currently has 18 degrees of freedom made up by two articulated arms, one movable robot head, and two charged coupled device (CCD) cameras for producing the stereoscopic views, and articulated cylindrical-type lower body, and an optional mobile base. A functional prototype is demonstrated.

Marzwell, Neville I.↗

The First Diffraction-Limited Images from the W. M. Keck Telescope

The first diffraction limited, 0.05s resolution, images on the W. M. Keck Telescope have been obtained at a wavelength of 2.2 micrometers. These images were part of an experiment to test the suitability of the Keck Telescope for speckle imaging. In order to conduct this test, it was necessary to modify the pixel scale of the Keck facility Near Infrared Camera (NIRC) to optimally sample the spatial frequencies made available by the Keck telescope. The design and implementation of the external reimaging optics, which convert the standard fl25 beam from the secondary mirror to fl182, are described here. Techniques for reducing speckle data with field rotation on an alt-az telescope are also described. Three binary stars were observed in this experiment with separations as small as 0.05s. With only 100 frames of data on each, a dynamic range of at least 3.5 mag was achieved in all cases. These observations imply that a companion as faint as 14.5 mag at 2.2 micrometers could be detected around an 11th magnitude point source.

Matthews, K.↗