Search NASA⌕ Search

SEARCH · Search NASA

Results for “station locator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Testing and Design of Discriminants for Local Seismic Events Recorded during the Redmond Salt Mine Monitoring Experiment

The Redmond Salt Mine (RSM) Monitoring Experiment in Utah was designed to record seismoacoustic data at distances less than 50 km for algorithm testing and development. During the experiment from October 2017 to July 2019, six broadband seismic stations were operating at a time, with three of them having fixed locations for the duration, whereas the three other stations were moved to different locations every one-and-half to two-and-half months. RSM operations consist of nighttime underground blasting several times per week. The RSM is located in proximity to a belt of active seismicity, allowing direct comparison of natural and anthropogenic sources. Using the recorded data set, we built 1373 events with local magnitude (M L ) of -2.4 and lower to 3.3. For 75 blasts (RMEs) from the Redmond Salt Mine and 206 tectonic earthquakes (EQs), both M L and the coda duration magnitude (MC) are well constrained. We used these events to test and design discriminants that separate the RMEs from the EQs and are effective at local distances. The discriminants consist of M L -M C , low-frequency Sg to high-frequency Sg, Pg/Sg phase-amplitude ratios, and Rg/Sg spectral amplitude ratios, as well as different combinations of two or more of these classifiers. The areas under the receiver operating characteristic curves (AUCs) of 0.92–1.0 for M L -M C , low-frequency Sg to high-frequency Sg, and Rg/Sg indicate that these discriminants are very effective. Conversely, the AUC of only 0.57 for Pg/Sg suggests that this discriminant is only slightly better than a random classifier. Among the effective classifiers, Rg/Sg, shows the lowest likelihood of misclassification (4.3%) for the populations. In conclusion, results of joint discriminant analyses suggest that even the arguably ineffective single classifier, like Pg/Sg in this case, can provide some value when used in combination with others.

58 GEOSCIENCES↗

Soil Temperature and Moisture, Council Road Mile Marker 71, Seward Peninsula, Alaska, beginning 2016

Daily averages of soil temperature and moisture measured once every hour at different heights, as well as daily averages of hourly measured snow depths located at Intensive Monitoring Stations at Council Road Mile Marker 71 site. Deployed at each site is an Onset HOBO U30 data logger with five smart temperature sensors and three smart soil moisture sensors (10HS). Three sites (CN_IS_4, CN_IS_6A, CN_IS_7) are equipped with a snow depth sensor. Data are retrieved annually since 2016. Contains 53 *.CSV files including a file inventory list by year. Data files have header rows, NaN fields indicate invalid or missing data, and negative vertical offsets are above ground. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Charging-management And Infrastructure-planning (cmip) Model

CMIP model explores various charging infrastructure network designs to serve a free-floating car-sharing fleet and determine the charging downtime experienced by the fleet for each design. Development of the CMIP model had two major steps: (1) describing modeling assumptions and (2) developing an integer program (IP) that jointly optimizes decisions about locations to install DC fast chargers and EV-to-charger assignments. The CMIP model integrates an EV charging model, EV energy consumption model, and heterogeneous, real-world vehicle use data with an integer programming optimization model to identify optimal location of new charging stations and calculate vehicle downtime for charging. The CMIP model can be applied to understand: (a) the reduction of EV fleet downtime if an additional fast-charging station is added to the current infrastructure and (b) to what extent total vehicle downtime would be sensitive to additional charging infrastructure.

Roni, MohammadS↗

DETECTING FIRE WITH MACHINE LEARNING-ENABLED VISUAL MONITORING FOR NUCLEAR POWER PLANT ENVIRONMENTS

Nuclear power plants are experiencing significant cost challenges to remain competitive with other energy-generation utilities. Unlike other industries, the cost of operation and maintenance activities is mostly attributed to workforce costs. To mitigate this, nuclear power plant stakeholders are increasingly interested in the development and deployment of machine learning methods to potentially automate or augment manually intensive tasks to reduce costs, especially for monitoring activities. One monitoring function that is visually demanding and that can occur frequently to meet the requirements of a fire protection program is visually monitoring an area for fire occurrence. Currently, fire watch activities consist of a worker physically stationed at a given location with the sole responsibility of observing a given area to ensure a fire is detected and mitigated promptly. This effort focused on the development and evaluation of a suitable deep convolutional neural network to classify individual video frames at a sub-second frequency for the occurrence of “fire” and “no fire” in varying industrial environments similar to nuclear power plants. It is believed that a trained neural network model could be integrated with existing facility video surveillance camera feeds to generate alerts when fire inferences occur in individual frames captured at sub-second temporal resolutions. Extensive effort was dedicated to identifying and curating suitable imagery training data representing varying environments and scene settings with and without flame features to maximize generalization in nuclear power plant environments. The data collection effort resulted in the aggregation of a large, labeled image library exceeding 12,000 images to support model training for diverse industrial environments. A deep neural network model incorporating parallel multi-scale capabilities was developed and trained to support accurate image-based detection of flame incidents of varying sizes and spectral feature properties within heterogeneous scenes. Analysis results show that the trained model can achieve high inference accuracy despite heterogeneous scene environments and components. Testing accuracy exceeded 95.0 percent with very low false positive and false negative inferences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Porewater data across a catena in the Luquillo Experimental Forest, Puerto Rico.

Landscape topography can influence biogeochemical processes in wet tropical forest soils. This dataset contains porewater concentrations of organic acid (acetate) from 2018 (February 22 to November 14) across a catena in the Luquillo Experimental Forest (LEF), Puerto Rico. The attached CSV file contains information on sampling date, location (El Verde field station) in LEF, topographic positions (ridge, slope, and valley, respectively), depth (unit: cm), and acetate concentration (unit: µM). Porewater concentrations of acetate were lower in the valley as compared to the ridge and slope topographic positions. This dataset can facilitate our understanding of the biogeochemical cycling of carbon and nutrient associated with complex topography in wet tropical forest soils.

54 ENVIRONMENTAL SCIENCES↗

Soil chemistry data across a catena in the Luquillo Experimental Forest, Puerto Rico

Landscape topography can influence biogeochemical processes across the wet tropical forest soils. This dataset contains soil chemistry data such as pH and dissolved organic carbon (DOC) from April 1, 2017 to May 1, 2018 across a catena in the Luquillo Experimental Forest, Puerto Rico. The attached CSV file contains information on sampling date, location (El Verde field station) in LEF, topographic positions (ridge, slope, and valley, respectively), field replicate number, laboratory replicate number, water extractable pH, CaCl2 extractable pH, and DOC (unit: mg/g). Overall, soil pH values were highest in the valley, followed by slope, and lowest in the ridge topographic positions. However, DOC values followed the opposite trend: ridge>slope>valley. This dataset can facilitate our understanding of the biogeochemical cycling of carbon and nutrient associated with complex topography in wet tropical forest soils.

54 ENVIRONMENTAL SCIENCES↗

Stream bed topography in 2016 at the Lower Montane site in the East River Watershed, Colorado

This dataset contains stream bed topography data from the Lower Montane site in the East River Watershed, Colorado. It is intended to support hydro-biogeochemical analyses for the Watershed Function Scientific Focus Area (SFA). The stream bed was surveyed using a RTK-GPS (Real-Time Kinematic Global Positioning System) and a total station at hundreds of locations during two field campaigns, conducted in October 2015 and October 2016. The two surveys were merged into a single product under the assumption of minimal changes in stream bed topography between the years. A LiDAR (Light Detection and Ranging) derived ground surface elevation product from 2015 (see reference below) was used to interpolate the stream bed topography and estimate water depth at the time of the LiDAR survey. The dataset includes three GeoTIFF products, two *.csv data files, and three *.csv metadata files. Feel free to contact the author with any questions.

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux PR-xLA NEON Lajas Experimental Station (LAJA)

This is the AmeriFlux version of the carbon flux data for the site PR-xLA NEON Lajas Experimental Station (LAJA). Site Description - The NEON Lajas Experimental Station (LAJA) site is located on the southwest corner of the main island of Puerto Rico in a experimental range. This is a grassland site that is periodically grazed by cattle.

Network), NEON (National Ecological Observatory↗

AmeriFlux FLUXNET-1F PR-xLA NEON Lajas Experimental Station (LAJA)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site PR-xLA NEON Lajas Experimental Station (LAJA). This is the FLUXNET version of the carbon flux data for the site PR-xLA NEON Lajas Experimental Station (LAJA) produced by applying the standard ONEFlux (1F) software. Site Description - The NEON Lajas Experimental Station (LAJA) site is located on the southwest corner of the main island of Puerto Rico in a experimental range. This is a grassland site that is periodically grazed by cattle.

Network), NEON (National Ecological Observatory [N↗

Predicting Seafloor Seismic Noise from Sea Surface Wave Heights and Vice Versa

Seismic hazard monitoring and global seismic tomography efforts are improved by recording seismic signals close to sources and at a variety of azimuths surrounding the source. While seismic networks have been deployed at many locations on land, seafloor stations are still sparse. Inclusion of ocean-based data would greatly improve the global coverage of seismic networks. However, the use of seafloor seismic data to complement land-based detection and characterization of events is complicated by the fact that ambient noise on the seafloor is in general much higher than noise levels on land. This noise is driven primarily by sea surface waves and tides. In this project, I define an empirical relationship between wave height and seafloor seismic displacement, and tie this relationship to the microseism noise theory of Longuet-Higgins and Ursell (1948). I find that while there appears to be a linear relationship between wave height and seismic displacement, wave height values can only be used with low confidence to predict seismic displacement and vice versa, and furthermore, factors other than wave height are significant in determining the level of seismic noise at a particular site.

58 GEOSCIENCES↗

Less-Than-Lethal Quick Deploy Inflatable Hall/Door Barrier: VISTA Feasibility Study

Physical protection of public buildings has long been a concern of police and security services where a balance of facility security and personnel safety is vital. Due to the nature of public spaces, the use of permanently installed and deploy-on-demand physical barrier systems must be safe for the legitimate occupants and visitors of that space. Such systems must seek to mitigate the personal and organizational consequences of unintentionally seriously injuring or killing an innocent bystander by slamming a heavy, rigid, and quick-deploying barrier into place. Consideration and implementation of less-than-lethal technologies is necessary to reduce risk to visitors and building personnel. One potential barrier solution is a fast-acting, high-strength, composite airbag barrier system for doorways and hallways to quickly deploy a less-than-lethal barrier at entry points as well as isolate intruders who have already gained access. This system is envisioned to be stored within an architecturally attractive selectively frangible shell that could be permanently installed at a facility or installed in remote or temporary locations as dictated by risk. The system would be designed to be activated remotely (hardwired or wireless) from a Central Alarm Station (CAS) or other secure location.

42 ENGINEERING↗

Soil nitrogen mineralization rates, nutrient stocks, stable isotopes, and water volumetric measurements across terrestrial-aquatic interfaces from three wetlands at the Tanglewood Biological Station, Alabama

This dataset supports a broader study investigating wetland hydrologic and biogeochemical responses to inundation events. Soil samples were collected across four sampling events along terrestrial-aquatic gradients at three wetland sites located within the Tanglewood Biological Station in Alabama from April 2024 to June 2025. The contents in this data package include soil in-situ nitrogen mineralization rates (measurements of net nitrification, net ammonification, and net mineralization), nutrient stocks (total carbon, total nitrogen, and organic matter), stable isotopes (carbon and nitrogen), and water volumetric measurements (water-filled pore space). Water level data related to each wetland location can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/2530253 (Kirker et al., 2024), related water geochemistry data can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3001967 (Forbes et al., 2025), and related surface water sediment chemistry data can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3377325 (Molina Serpas et al., 2026). In addition to this readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) file-level metadata; (2) data dictionary; (3) field metadata and international generic sample numbers (IGSNs); (4) readme; (5) the field protocol; and (6) a subfolder with sample data. The sample data subfolder contains (1) net nitrification rate, (2) net ammonification rate, (3) areal net mineralization rate, (4) percent organic matter, (5) water-filled pore space, (6) total carbon content, (7) total nitrogen content, (8) stable carbon isotope (delta carbon-13), and (9) stable nitrogen isotope (delta nitrogen-15), and (10) methods codes. All files are .csv or .pdf.

13-C↗

AmeriFlux FLUXNET-1F US-SHC Sagehen Creek Field Station

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-SHC Sagehen Creek Field Station. This is the FLUXNET version of the carbon flux data for the site US-SHC Sagehen Creek Field Station produced by applying the standard ONEFlux (1F) software. Site Description - This tower is located at the Sagehen Creek Field Station of UC Berkeley. The 30m tower near the station has been used for meteorological measurements since at least 2006 and EC flux measurements were started in late June 2017. The area is dominated by coniferous forest with patches of grassland in between.

Wolf, Sebastian [ETH Zurich]↗

Siting and sizing of public–private charging stations impacts on household and electric vehicle fleets

To facilitate the provision of electric vehicle charging stations (EVCS) in urban areas, this study investigates the benefits of co-locating fleet-owned chargers with public charging stations to enable construction incentives and cord-sharing cost savings. Shared EVCS can serve charging demand from both user types: private (household) EV owners and those managing fleet vehicles – like shared and fully automated EV (SAEV) fleets. Using POLARIS to simulate all person-travel across the 6-county Austin, Texas region, new EVCS were sited and sized with DC fast-charging (DCFC) plugs to lower operating and construction costs while providing public + private (PP) service across an 81-square-mile core geofence (where 200 SAEVs were active) over 24-hour days. When co-location is permitted, 115 DCFC cords were added to the 23 existing (publicly available) stations to enable SAEVs and household EVs (HHEVs) charging access, within the geofence. Each 250-mile-range SAEV was simulated to travel an average of 330 miles per day, serve over 92 person-trips, and recharge 2.7 times a day (for 2.4 h per session). The new DCFC plugs were primarily added to public EVCS at shopping centers and schools, and in residential settings along freeways. The average plug served 4.8 EVs per day. Most co-located PP EVCS permitted immediate (no-wait) charging, except for 2 stations along freeways that averaged 8 min of wait time to begin charging. In conclusion, the co-location strategy lowered fleet owners’ initial EVCS construction costs by 12 % (thanks to cord-sharing to avoid cord duplication), while reducing SAEV wait times to just 3.1 min (versus 10.7 min if SAEV managers had to build and operate their own EVCS).

EV charging modeling↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations

This paper presents an analysis of grid voltage control strategies for heavy-duty electric vehicle charging stations. The performance of three voltage control approaches—including power factor control, standardized volt-volt ampere reactive (VAR) curve control, and customized volt-VAR curve control—are investigated and evaluated for three different sizes of charging stations, including a single-port charging station, a midsized three-port charging station, and six-port travel center. The charging stations are placed on multiple locations of four different types of distribution systems to obtain a comprehensive performance analysis of the voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics are designed to quantify the performance and contribute to the comprehensive analysis.

47 OTHER INSTRUMENTATION↗

Ghent Generating Station Nuclear Study: Siting Evaluation

The purpose of this initial siting evaluation is to assess the suitability of the PPL Corporation (PPL) owned land at/near the Kentucky Utilities Ghent Generating Station (GGS) for the deployment of advanced nuclear reactors and to determine if there are any exclusionary or avoidance factors associated with siting nuclear power at GGS. The formal siting process for a nuclear reactor requires a great level of time (i.e., multiple years), effort, and detail. The Electric Power Research Institute (EPRI) estimates the formal siting process could take a dedicated team between one and three years to complete. This initial siting evaluation considers several characteristics (e.g., environmental conditions, seismic concerns, footprint, water use, etc.) and highlights favorable/preferred characteristics as well as potential risks to feasibility. Potential risks were explored in greater detail to provide PPL with additional insights to support decision planning. The results indicate the strengths and weaknesses associated with the GGS site as a location for a nuclear generating station and are intended to inform PPL’s next steps. The results of this initial siting evaluation will also inform the selection of candidate nuclear technologies for the GGS site that align with PPL’s mission and business objectives.

99 GENERAL AND MISCELLANEOUS↗

Optimal Siting of EV Fleet Charging Station Considering EV Mobility and Microgrid Formation for Enhanced Grid Resilience

Coordinating infrastructure planning for transportation and the power grid is essential for enhanced reliability and resilience during operation and disaster management. This paper presents a two-stage stochastic model to optimize the location of electric vehicle fleet charging stations (FEVCSs) to enhance the resilience of a distribution network. The first stage of this model deals with the decision to place an FEVCS at the most favorable and optimized location, whereas the second stage aims to minimize the weighted sum of the value of lost load in multiple potential scenarios with different faults. Indeed, the second stage is a joint grid restoration scheme with network reconfiguration and microgrid formation using available distributed generators and fleet electric vehicles. The proposed model is tested on a modified IEEE-33 node distribution network and a four-node transportation network. Case studies demonstrate the effectiveness of the proposed model.

25 ENERGY STORAGE↗