A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (↗

Finned-tube-integrated modular thermal storage systems for HVAC load modulation in buildings

While there is considerable focus on latent-based thermal energy storage (TES) systems, the low thermal conductivity of phase change materials (PCMs) remains a critical concern. Many approaches to enhance PCM conductivity either require complicated synthesis processes or are cost prohibitive. In this study, we investigate finned-tube modular TES systems, which are simple in design, easy to manufacture, and cost-effective due to their standard materials and components. The study includes detailed modeling and experimentation of two devices containing similar amounts of PCM but different fin spacings. The study reveals that having more fins does not necessarily increase the TES thermal performance because the reduction in the PCM volume fraction can reduce the TES volumetric and specific energy densities. We find that larger fin spacings provide a higher specific energy for lower C rates (<1C), while smaller fin spacings provide a higher specific energy for higher C rates (>1C).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Distributed Wind and Battery Energy Storage Systems

This document is a literature review of battery coupled distributed wind applications, including but not limited to fully DC-based power systems, the conceptual value of co-located wind and storage assets, and black start capabilities. This report will serves as a baseline reference document for MIRACL hybrids system research and to identify opportunities for future research in this space.

17 WIND ENERGY↗

Consumer Benefits of Clean Energy: The resilience value of residential solar + storage systems in the continental U.S.

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. Clean energy resources that are located behind the meter have the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Solar plus storage systems (PVESS) are clean energy resources that can supply backup power without requiring fuel resupply or increasing local emissions. This report examines the regional value of PVESS for resilience by calculating a benefit-cost ratio (BCR) that considers the annual resiliency benefits of PVESS and the annualized cost of the investment. In addition, we estimate the expected technical mitigation potential of PVESS systems at the county-level to these expected events, and characterize the customer interruption costs by determining the value of lost load at the state level.

14 SOLAR ENERGY↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Integrated Heat Exchanger/Thermal Energy Storage System for CSP Plants

The research and development during the project focused on the design and optimization of an integrated heat exchanger/thermal energy storage (HX/TES) system, the charging and discharging performance of the developed HX/TES system, and the experimental investigation of lab-scale prototypes based on the full-scale system.

42 ENGINEERING↗

Thermal Modeling of Advanced Test Reactor Fuel in a Generalized Dry Storage System Under Hypothetical Accident Conditions

Work was performed to investigate the thermal behavior of a sealed aluminum-clad spent nuclear fuel (ASNF) dry storage configuration under hypothetical accident conditions during long-term storage. The considered system consists of a concrete dry storage overpack; a welded over canister, backfilled with argon; and nine Department of Energy (DOE) standardized canisters (DOESCs) loaded with ASNF, backfilled with helium gas. One technical concern associated with the long-term storage of ASNF includes radiolytic hydrogen generation. The yield of large quantities of hydrogen could lead to DOESC over pressurization or a flammable internal atmosphere. While flammability concerns can be resolved by preventing the ingress of oxygen, the canister pressure is partially controlled by the atmosphere temperature. This memorandum summarizes the results of modeling and simulation (M&S) work completed with Star CCM+ (a computational fluid dynamics [CFD] software) considering the thermal effects of a fully engulfing flame and another scenario with the vent ports of the concrete dry storage overpack completely blocked. The goal was to determine the bounding maximum temperature of the DOESC internal atmosphere to evaluate a worst-case pressure scenario, as well as the critical vent port blockage durations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation of Gray-box and Machine Learning Models of a Thermal Energy Storage System with Active Insulation

An interior partition wall integrated with active thermal storage and a dynamic insulation system was built and then installed in an office building in Oak Ridge, Tennessee, TN. This smart wall, termed the Empower Wall, was equipped with embedded pipes in the building envelope core component and an additional pipe network enclosing rigid insulation to switch on and off the active insulation dynamically. The performance of the wall's contribution to cooling load reduction under different parameters has been investigated in previous publications. Aiming to be deployed into model predictive control and other optimization methods, simplified and reliable models for the developed wall and the room accommodating it are required. They are needed to characterize the properties and thermal response of both Empower Wall and building envelope, which form an essential component for accurate indoor temperature or cooling/heating demand prediction. In this study, simplified gray-box and regression models as well as machine learning model were developed and the performance of them were compared and analyzed.

Cui, Borui↗

Energy burden aware and thermal resilience informed thermal energy storage system planning for disadvantaged communities

Disadvantaged communities often face a disproportionate energy burden because they need to allocate a higher percentage of their income to energy costs. More importantly, climate change-induced extreme weather events, such as heat waves and severe cold snaps, exacerbate these communities’ energy burdens. As a result, low- and medium-income communities are more likely to experience energy supply disruptions, increased health risks, and elevated energy bills because of inadequate thermal insulation and airtightness in their houses. Thermal energy storage (TES) systems, such as large-scale (community-level) geothermal energy storage and small-scale (building-level) phase change material (PCM)–based storage, have a great potential to improve building energy efficiency and to enhance thermal comfort, load shifting, and integration with renewable energy. The objective of this study is to optimally allocate building level PCM-based TES systems at the community level by considering energy equity and extreme weather effects. To this end, we developed an energy burden and thermal resilience–informed TES system planning framework, which includes three modules: (1) a community-level energy burden and thermal resilience assessment module, (2) building-level a TES system integration and assessment module, and (3) a community-level optimal planning module. Case studies were conducted on four disadvantaged communities in Montgomery and Shelby Counties in Tennessee with energy burdens >10% and with high percentages of people of color. The results indicate that this comprehensive planning framework can assist disadvantaged communities in reducing their energy burden and in bolstering their resilience against the adverse effects of climate change.

Shen, Zhenglai↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of two concrete thermal energy storage system configurations for continuous power production

Two Modelica concrete thermal energy storage (CTES) models are built to analyze potential CTES system designs. One design is the single pipe network design wherein a heat transfer fluid (HTF) flows in one direction during heat deposition and the opposite direction during heat removal. All pipes in the network are used for either deposition (charging) or removal (discharging). The second design is a dual pipe network design in which a network of HTF pipes carries charging fluid and a separate piping network carries discharging HTF. Operation of these two configurations to produce constant steam is evaluated. Here, results indicate that the designs are likely appropriate for different applications with the single pipe network appearing appropriate for batch energy applications and the dual pipe network for continuous energy applications.

25 ENERGY STORAGE↗

Improving charge transport in integrated MoO 3 /C electrode materials for water-in-salt energy storage systems by incorporating oxygen vacancies

Improvements in the charge storage properties of α-MoO 3 used as an electrode with a 30m ZnCl 2 water-in-salt electrolyte have been achieved by enhancements in electron and ion transport enabled by an inventive synthesis route. Electron transport was improved through the integration of MoO 3 with dopamine-derived carbon via a chemical preintercalation route, and enhanced ion transport was achieved by incorporating oxygen vacancies in MoO 3 structure through ethanol 2 reduction under hydrothermal conditions. Here, the presence of carbon was confirmed by corresponding D and G bands observed in Raman spectroscopy measurements. The presence of oxygen vacancies was proven through correlated XPS, TGA, Raman spectroscopy and XRD analyses, with the introduction of oxygen vacancies leading to an expanded interlayer region. Four-point probe measurements provided evidence of increased electronic conductivity due to the incorporation of carbon, and cyclic voltammetry-based charge storage mechanism analyses revealed increases in ion transport kinetics due to oxygen vacancy formation. Tuning the oxygen vacancy concentration is critical, as excessive concentrations of these point defects leads to structural instability and poor capacity retention. This work demonstrates the combined potential of carbon and oxygen vacancies in moderate concentrations to enhance the charge storage properties of transition metal oxides. The strategies developed in this study offer a path to the development of promising materials for high-rate, high-capacity, and long-duration electrochemical energy storage technologies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Particle-based thermal energy storage systems

Methods and devices for long-duration electricity storage using low-cost thermal energy storage and high-efficiency power cycle, are disclosed. In some embodiments it has the potential for superior long-duration, low-cost energy storage.

Ma, Zhiwen↗

Particle-based thermal energy storage systems

Methods and devices for long-duration electricity storage using low-cost thermal energy storage and high-efficiency power cycle, are disclosed. In some embodiments it has the potential for superior long-duration, low-cost energy storage.

Ma, Zhiwen↗

Acoustic Emissions Sensing for Tracing Carbon Dioxide Movement in Caprock of a Carbon Capture Utilizations and Storage System (CCUS) (Final Technical Report)

The overall objective of this research project was to develop a non-invasive acoustic-emission (AE)-based technology that can accurately predict the location and movement of CO 2 through a confining layer in a carbon capture, utilization, and storage (CCUS) system. Specifically, the aim was to explore the feasibility of using the Haines jumps AEs as a passive method to track movement of CO 2 in reservoirs used for CCUS applications.

47 OTHER INSTRUMENTATION↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Impact of Hybrid Energy Storage System (HESS) Topologies on Performance: Exploration for Hydropower Hybrids

We investigate the technical performance of six HESS topologies integrated with run-of-river (ROR) hydropower to provide frequency support. We choose ROR hydropower because there are 23 GW of installed ROR hydropower in the U.S. and integrating these plants with energy storage could boost their contribution to grid services. We focus on HESSs composed of batteries and ultracapacitors because batteries are cost effective for storing energy but degrade more quickly as a function of cycling. In contrast, ultracapacitors can be cycled millions of times and are cost effective for quick injections of power. We find that active HESS topologies demonstrate the best overall improvement to grid frequency during a contingency while adhering to the power ramping limits of the HESS devices. Future work will investigate other services to identify if one HESS topology performs best for all services of interest or, more likely, different HESS topologies are best suited for specific services.