Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotron beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Toward fully coherent soft x-ray free-electron laser via echo-enabled harmonic generation in fourth generation synchrotron light sources

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci. Rep. 12, 9437 (2022)], we demonstrate that this EEHG scheme can be easily adopted to any fourth generation diffraction-limited synchrotron light source with significant benefits. The advantage of the scheme is that it requires no change of the lattice and is fully compatible with other beamlines. Since the EEHG performance is mainly determined by the momentum compaction, beam emittances, and beta functions of a SR lattice, we have identified these crucial parameters and successfully built a generalized model, which can predict the performance of nearly any SLS. Regarding the fourth generation SLSs, momentum compactions are often significantly smaller; thus, to cover the x rays with a photon energy of up to 1 keV, we utilize a specific design, including a 250 nm seed-laser wavelength. Our model predicts that for most of the current and future fourth generation SLSs, the EEHG scheme can produce significant prebunching up to harmonic 200 and, thus, generate a few MW scale peak power at 1.25 nm wavelength.

47 OTHER INSTRUMENTATION↗

AMX – the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 10 12 photons s −1 ), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.

36 MATERIALS SCIENCE↗

ORBIT CORRECTION STUDIES ON THE ELECTRON TRANSPORT LINE FROM RCS TO ESR

A dedicated electron transfer line from Rapid Cycling Synchrotron (RCS) to Electron Storage Ring (ESR), referred to as the RTE line has been designed for the Electron-Ion Collider (EIC). The beamline follows a straight-line geometry, with a length of 133 m, and is consists with two matching sections and a FODO section for beam diagnostics. Imperfections with magnet alignments introduce orbit distortions, making orbit correction scheme a critical component in the design. To facilitate orbit correction, each quadrupole magnet is equipped with a pair of beam position monitors (BPMs) and kickers. The Singular Value Decomposition (SVD) algorithm is used for orbit correction and tolerance studies. This paper presents the ongoing progress in the optics design and error correction scheme of the RTE line.

Neththikumara, I. [Thomas Jefferson National Accel↗

hkl-projects/ioc-hkl

HKL-IOC is an open source EPICS IOC that performs real‑time crystallographic HKL calculations for diffractometers and scattering instruments. It integrates the Python hkl library with EPICS through PyDevice, exposing HKL calculations and diffractometer geometry transformations as standard EPICS process variables. This allows beamline and laboratory control systems to convert between motor positions and reciprocal‑space coordinates, configure diffractometer geometries, and drive scans directly in HKL space. The software is written in Python and designed to run alongside existing EPICS deployments without requiring changes to core EPICS components. It is intended for use at synchrotron and neutron scattering facilities, as well as laboratory X‑ray diffractometers, where reliable and reproducible HKL calculations are needed for experiment control, data collection, and automation. HKL-IOC is distributed under the GNU General Public License v3.0 (GPL‑3.0) and contributions and extensions for additional geometries and beamlines are welcomed.

Baekey, Alex↗

Three-dimensional mapping of mineral in intact shark centra with energy dispersive x-ray diffraction

The centra of shark vertebrae consist of cartilage mineralized by a bioapatite similar to bone's carbonated hy-droxyapatite, and, without a repair mechanism analogous to remodeling in bone, these structures still survive millions of cycles of high-strain loading. The main structures of the centrum are an hourglass-shaped double cone and the intermedialia which supports the cones. Little is known about the nanostructure of shark centra, spe-cifically the relationship between bioapatite and cartilage fibers, and this study uses energy dispersive diffraction (EDD) with polychromatic synchrotron x-radiation to study the spatial organization of the mineral phase and its crystallographic texture. The unique energy-sensitive detector array at beamline 6-BM-B, the Advanced Photon Source, enables EDD to quantify the texture within each sampling volume with one exposure while constructing 3D maps via specimen translation across the sampling volume. Herein this study maps a centrum from two shark orders, a carcharhiniform and a lamniform, with different intermedialia structures. In the blue shark (Prionace glauca, Carcharhiniformes), the bioapatite's c-axes are oriented laterally within the centrum's cone walls but axially within the wide wedges of the intermedialia; the former is interpreted to resist lateral deformation, the latter to support axial loads. In the shortfin mako (Isurus oxyrinchus, Lamniformes), there is some tendency for c-axis variation with position, but the situation is unclear because one dimension of the sampling volume is consid-erably larger than the thickness and spacing of the intermedialia's radially-oriented lamellae. Because elastic modulus in collagen plus bioapatite mineralized tissues varies significantly with both volume fraction of bio-apatite and crystallographic texture, the present 3D EDD-derived maps should inform future 3D numerical models of shark centra under applied load.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental setup for high-resolution characterization of crystal optics for coherent X-ray beam applications

Stanford Synchrotron Radiation Lightsource serves a wide scientific community with its variety of X-ray capabilities. Recently, a wiggler X-ray source located at beamline 10-2 has been employed to perform high-resolution rocking curve imaging (RCI) of diamond and silicon crystals. X-ray RCI is invaluable for the development of upcoming cavity-based X-ray sources at SLAC, including the cavity-based X-ray free-electron laser and X-ray laser oscillator. In this paper, the RCI apparatus is described and experimental results are provided to validate its design. Future improvements of the setup are also discussed.

36 MATERIALS SCIENCE↗

Permanent Magnets for the CEBAF 24GeV Upgrade

An upgrade of the CEBAF facility to double its present energy of 12GeV has been proposed. To provide double the number of linac passes using the existing five stacked arc beamlines, some beamlines are replaced by fixed-field accelerator (FFA) arcs, allowing multiple energies to pass through the same magnets. A solution is presented in which two of the existing electromagnetic beamlines are replaced with permanent magnet non-scaling FFA arcs, as demonstrated at CBETA. The two-stage design reduces peak magnetic field and synchrotron radiation loss compared to using a single stage. FFAs do not pulse their magnets, making permanent magnets a promising and power-efficient technology option. However, the magnetic field requirements are still at the high end of accelerator permanent magnets produced thus far (1.6T peak on beam), while the magnets must also be combined-function, having a gradient with a dipole offset. Designs using a novel oval aperture and open midplane within an adapted Halbach magnet are presented.

Brooks, S. J.↗

The Electron Spectro-Microscopy (ESM) Beamline at NSLS-II

Photoelectron spectroscopy is a primary tool for the study of the electronic structure of materials and the chemical composition of surfaces. High-resolution angle-resolved photoemission spectroscopy (ARPES) has the unique ability to map the energy bands in momentum space. Furthermore, going beyond the single particle picture, the self-energy corrections caused by correlations in solids can be extracted from the analysis of the emission line shape. The current level of refinement, in terms of energy and angular resolution (ΔE < 1 meV, Δθ < 0.1°), makes the technique sensitive to the lowest energy excitations and the dynamics of electrons, which in turn virtually determine all the macroscopic properties of any system and govern the chemical, electrical, magnetic, and physical processes. Similarly important, X-ray photoelectron microscopy (XPEEM), combined with the low-energy electron microscopy (LEEM), is indispensable in probing the complexity of chemical, structural, electronic and magnetic properties of surfaces and shallow interfaces, with the spatial resolution of few tens of nanometer (nm). The Electron-Spectro-Microscopy beamline (ESM) has been recently commissioned at NSLS-II and is now in operation. The primary spectroscopic technique is photoemission, performed over a wide energy range with control of light polarization and in a variety of flux/resolution conditions. The beamline has two experimental end stations that allow to perform ARPES and XPEEM/LEEM, separately. The ARPES end station focuses on high energy-resolution work, with spot-size of a few microns. The XPEEM/LEEM end station is a full-field microscope (XPEEM) operating either with the synchrotron generated X-rays (XPEEM), or with an internal electron gun (LEEM). Spatial resolution is crucial in studies of newly synthesized complex materials since they are often initially available only as small specimens (typically micron size). Furthermore, chemical inhomogeneities on surfaces are often an integral part of surface chemical processes. Finally, the ESM beamline with X-ray spots of few microns is optimized to study the electronic structure of novel materials with microscopy capabilities.

47 OTHER INSTRUMENTATION↗

Embedded EPICS server for PowerPMAC motion controllers

An embedded server layer of Experimental Physics and Industrial Control System (EPICS) for PowerPMAC motion controllers has been developed and deployed at two undulator beamlines of the National Institute of General Medical Sciences and the National Cancer Institute (GM/CA) Structural Biology Facility at the Advanced Photon Source (APS). This compact, open source solution makes the power and versatility of PowerPMAC motion controls directly accessible to distributed EPICS clients. At GM/CA the system controls about 200 servo and stepper motors — both encoded and unencoded — and multiple digital and analog I/O accessories. The server stack comprises two sublayers: a lower-level driver and database that communicates directly with PowerPMAC, and a facility-specific soft sublayer built on top. The paper describes installing EPICS on PowerPMAC, the implementation of both layers and client examples, including on-the-fly scanning.

EPICS↗

In situ synchrotron X-ray total scattering measurements and analysis of colloidal CsPbX 3 nanocrystals during flow synthesis

In situ X-ray scattering measurements of CsPbX 3 (X = Cl, Br, I) nanocrystal formation and halide exchange at NSLS-II beamlines were performed in an automated flow reactor. Total scattering measurements were performed at the 28-ID-2 (XPD) beamline and small-angle X-ray scattering at the 16-ID (LiX) beamline. Nanocrystal structural parameters of interest, including size, size distribution and atomic structure, were extracted from modeling the total scattering data. The results highlight the potential of these beamlines and the measurement protocols described in this study for studying dynamic processes of colloidal nanocrystal synthesis in solution with timescales on the order of seconds.

nucleation↗

APS: High-Energy X-rays Expediting Applied and Fundamental Research

The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) was designed and built as one of the first large 3rd generation synchrotrons operated at 7 GeV. The United States Department of Energy (DOE) Office of Science funded the construction and continues to fund the operation of this national facility. Furthermore, the beamlines were originally operated by Collaborative Access Teams (CAT), which allowed a strong involvement of research institutes, universities, and industry. Today 43 of 68 beamlines are operated by the X-ray Science Division (XSD) and 35 beamlines are directly funded by the DOE Office of Science. The APS became operational in 1995, and was planned right from the beginning with 4 beamlines dedicated to high-energy x-rays above 40 keV: 1-ID designed to study engineering materials science, 6-ID-D for magnetism and condensed matter research, 11-ID-B dedicated to magnetic Compton scattering using an Elliptical Multipole Wiggler, and 11-ID-C for materials science and condensed matter physics. These stations were later joined by the bending magnet beamlines 6-BM for white beam studies and 17-BM for rapid powder diffraction. CAT operated beamlines such as 15-ID for crystallography or 16-ID for high-pressure studies also use the high-energy x-ray regime frequently. The program in Compton scattering ended in 2004 and the wiggler was replaced by an undulator. 11-ID-B became the first dedicated station for Pair Distribution Function (PDF) Analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Evaluation of quantitative synchrotron radiation micro-X-ray fluorescence in rice grain

Concentrations of nutrients and contaminants in rice grain affect human health, specifically through the localization and chemical form of elements. Methods to spatially quantify the concentration and speciation of elements are needed to protect human health and characterize elemental homeostasis in plants. Here, an evaluation was carried out using quantitative synchrotron radiation microprobe X-ray fluorescence (SR-µXRF) imaging by comparing average rice grain concentrations of As, Cu, K, Mn, P, S and Zn measured with rice grain concentrations from acid digestion and ICP-MS analysis for 50 grain samples. Better agreement was found between the two methods for high-Z elements. Regression fits between the two methods allowed quantitative concentration maps of the measured elements. These maps revealed that most elements were concentrated in the bran, although S and Zn permeated into the endosperm. Arsenic was highest in the ovular vascular trace (OVT), with concentrations approaching 100 mg kg –1 in the OVT of a grain from a rice plant grown in As-contaminated soil. Quantitative SR-µXRF is a useful approach for comparison across multiple studies but requires careful consideration of sample preparation and beamline characteristics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Report: A timeline for the synchrotron calibration of AXAF

Presented herein are the known elements of the timeline for synchrotron reflectance calibrations of HRMA witness samples (Section 2). In Section 3, lists of measurements to be done on each witness flat are developed. The elements are then arranged into timelines for the three beamlines we expect to employ in covering the full 50-12,000 eV energy range (Section 4). Although the required AXAF operational range is only 0.1-10 keV, we must calibrate the extent to which radiation just outside this band may contaminate our in-band response. In Section 5, we describe the working relationships which exist with each of the beamlines, and estimate the time available for AXAF measurements on each. From the timelines and the available time, we calculate the number of flats which could be measured in full detail over the duration of the program for each beamline. A suggestion is made regarding a minimum required baselines of witness flats from each element coating run or qualification run to be used in the calibration. We intend that this suggestion open discussion of the issue of witness flat deployment.

Tananbaum, H. D.↗

Fast-current-heating devices to study in situ phase formation in metallic glasses by using high-energy synchrotron radiation

Details of fast-resistive-heating setups, controlled heating ranging from ~10 1 K s –1 to ~10 3 K s –1 , to study in situ phase transformations (on heating and on cooling) in metallic glasses by high-energy synchrotron x-ray diffraction are discussed here. Both setups were designed and custom built at the Leibniz Institute for Solid State and Materials Research Dresden (IFW Dresden) and have been implemented at the P02.1 Powder Diffraction and Total Scattering Beamline and the P21.1 Swedish Materials Science Beamline at PETRA III storage ring, DESY, Hamburg. The devices are interchangeable at both beamlines. Joule heating is triggered automatically and is timed with the incident beam and detector. The crystallization process can be controlled via a feedback circuit by monitoring the change in the time-dependent resistivity and temperature of glasses. Different ambient atmospheres, such as vacuum and inert gases (He and Ar), can be used to control oxidation and cooling. The main focus of these devices is on understanding the crystallization mechanism and kinetics in metallic glasses, which are brittle and for which fast heating gives defined glass–crystal composites with enhanced plasticity. As an example, phase-transformation sequence(s) in a prototyped Cu–Zr-based metallic glass is described on heating, and a crystalline phase beneficial to the plasticity is identified.

47 OTHER INSTRUMENTATION↗

In situ temperature synthesis and characterization of ferroelectric PZN-4.5PT nanoparticles’ thin films using synchrotron light source

Despite the excellent properties of Pb(Zn 1/3 Nb 2/3 )O 3 -4.5PbTiO 3 (PZN-4.5PT) single crystals, the greatest difficulty for their application on electronic devices is to make them to thin layers related to the difficulty to make them as ceramic materials. In this paper, we use the combined USAXS/SAXS/WAXS instrument at 9ID beamline at APS-ANL for in situ characterization of PZN-4.5PT inorganic perovskite nanoparticles thin films deposited on nanotextured silicon to understand the phase transitions and determine the observed microcrystals' structure. Here, the sample was annealed from ambient to 1000°C. The results revealed structure changes in the nanoparticles' thin films which could be explained by the new phase that can be assigned to the Pb 3 (PO 4 )2-based component. The peak at 31° indicates the presence of the rhombohedral phase perovskites assigned to the nanoparticles. WAXS characterization permitted to identification of many transitions during thermal annealing like dehydration or dihydroxylation of phosphorus gel -OH bonds and internal water.

36 MATERIALS SCIENCE↗

X-ray-based technologies in emerging fuel cell research

The workshop titled `X-ray-based technologies in emerging fuel cell research', organized by Vivian Stojanoff from Brookhaven National Laboratory (BNL) and Narayanasami Sukumar from Cornell University/Advanced Photon Source-Northeastern Collaborative Access Team, was a notable segment of the National Synchrotron Light Source II and Center for Functional Nanomaterials Users' Meeting held 13–17 May 2024. This one-day event, on 13 May 2024, at BNL in New York, aimed to bring together researchers, beamline scientists, management and developers to propel fuel cell technology forward using model systems inspired by natural photosynthesis and redox enzymes. Furthermore, this summary encapsulates the key discussions, advancements and future implications of the workshop.

Xray↗