Flexible CHP System with Low NOx, CO and VOC Emissions
This factsheet describes a project that developed a FlexCHP-65 system that incorporates new burner technology into a 65 kW microturbine and 100 HP heat recovery boiler.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This factsheet describes a project that developed a FlexCHP-65 system that incorporates new burner technology into a 65 kW microturbine and 100 HP heat recovery boiler.
There is increased interest in performing electromagnetic transient (EMT) studies of large power grids for stability purposes. The large power grids may not represent the entire grid, but portions of interest. For example, studies are being performed to identify the impact of extreme events on solar power plants in California that requires the EMT model of the grid in California, but not the complete western interconnection (WI) grid model to which the grid in California is connected. The EMT models of grids are necessary to perform integration studies of large power electronics systems like utility-scale photovoltaic (PV) systems, high-voltage direct current (HVdc) systems, flexible alternating current transmission systems (FACTs), and others. Traditionally, models of grids available to utilities are the transient stability (TS) models. Hence, it assumes significance to identify methods of developing high-fidelity EMT models for portions of the grid (of interest) from the information available in the existing TS models of the entire grid. In this paper, a conversion mechanism along with upgradation based on data-driven methods is applied to develop EMT models of grids. The conversion mechanism utilizes information from TS models of grids to generate EMT models of grids. These models can be extracted for the required portion of the grid. While these models adequately represent the local voltage behaviour of the grid, they are inadequate in representing the frequency behaviour of the grid. The data-driven methods are applied to identify frequency dynamics of the grid, and the EMT models are upgraded with the data-driven methods. The resulting upgraded EMT models of grids can perform the studies mentioned above. These models are tested under contingencies of interest to validate the developed models.
A system includes conductive windings extending around a magnetic core and impedance-varying windings extending around the magnetic core. The impedance-varying windings include positive windings and negative windings. The conductive windings and the impedance-varying windings conduct electric current around the magnetic core. The system includes a first impedance tap changer that is electrically coupled with the positive windings of the impedance-varying windings and a second impedance tap changer electrically coupled with the negative windings of the impedance-varying windings. A controller controls the first impedance tap changer and the second impedance tap changer to change an impedance of the system by changing which portion of the positive windings and which portion of the negative windings are conductively coupled with the conductive windings, and which portion of the positive windings and which portion of the negative windings are disconnected from the conductive windings.
Thrust vector control systems that superimpose a side force on the motor thrust, steering being achieved by the side force causing a moment about the vehicle center of gravity are described. A brief review of thrust vector control systems is presented, and two systems, flexible joint and liquid injection, are treated in detail. Treatment of the flexible-joint thrust vector control system is limited to the design of the flexible joint and its insulation against hot motor gases. Treatment of the liquid injection thrust vector control system is limited to discussion of the injectant, valves, piping, storage tanks, and pressurization system; no evaluation is presented of the nozzle except for (1) the effect of the injectant and erosion at the injection port and (2) the effect of injection on pressure distribution within the nozzle.
A flexible combined heat and power (F-CHP) concept, enabled by a power electronics-based power conditioning system (PCS), has been recently proposed as a cost-effective way for supporting the grid with high penetration of renewable energy sources. To verify the design, control, and performance of the overall system, a laboratory-scale testbed is essential. This paper focuses on the development of a power electronics-based testbed for such a F-CHP system. The developed testbed can test the control, grid-connected mode operation, islanded mode operation, and mode transitions, including planned/unplanned islanding and reconnection, of the F-CHP system. In the grid-connected mode, both the steady state and transients of the ac grid can be emulated, and various grid support functions can be tested with the help of the developed PCS converter. In the islanded mode, the external ac loads can also be supported by the F-CHP system. Also, the central controller, which is implemented in a NI CompactRIO, can be tested. Experimental test results for the grid-connected mode, islanded mode, and mode transitions are provided to validate the testbed design.
Twenty-first century power systems, with higher penetration levels of low-carbon energy, smart grids, and other emerging technologies, will favor resources that have low marginal costs and provide system flexibility (e.g., the ability to cycle on and off to follow changes in variable renewable energy plant output). Questions remain about both the fate of coal plants in this scenario and whether they can cost-effectively continue to operate if they cycle routinely. The experience from the CGS plant demonstrates that coal plants can become flexible resources. This flexibility - namely the ability to cycle on and off and run at lower output (below 40% of capacity) - requires limited hardware modifications but extensive modifications to operational practice. Cycling does damage the plant and impact its life expectancy compared to baseload operations. Nevertheless, strategic modifications, proactive inspections and training programs, among other operational changes to accommodate cycling, can minimize the extent of damage and optimize the cost of maintenance. CGS's cycling, but not necessarily the associated price tag, is replicable. Context - namely, power market opportunities and composition of the generation fleet - will help determine for other coal plants the optimal balance between the level of cycling-related forced outages and the level of capital investment required to minimize those outages. Replicating CGS's experience elsewhere will likely require a higher acceptance of forced outages than regulators and plant operators are accustomed to; however, an increase in strategic maintenance can minimize the impact on outage rates.
Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.
A flexible transformer system includes conductive windings extending around a magnetic core of a transformer phase and impedance-varying windings extending around the magnetic core of the transformer phase. The conductive windings and the impedance-varying windings are configured to conduct electric current around the magnetic core of the transformer phase. The system includes an impedance switch coupled with the impedance-varying windings and with the conductive windings. The impedance switch is configured to change an impedance of the system by changing which impedance-varying winding of the impedance-varying windings is conductively coupled with the conductive windings and which impedance-varying winding of the impedance-varying windings is disconnected from the conductive windings.
The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory has developed a data acquisition system flexible and powerful enough to meet the needs of a variety of high energy physics applications. The system described in this paper is called CAPTAN (Compact And Programmable daTa Acquisition Node) and its architecture and capabilities are presented in detail here. The three most important characteristics of this system are flexibility, versatility and scalability. These three main features are supported by key architectural features; a vertical bus that permits the user to stack multiple boards, a gigabit Ethernet link that permits high speed communications to the system and the core group of boards that provide specific capabilities for the system. In this paper, we describe the system architecture, give an overview of its capabilities and point out possible applications.
High gain, high frequency flexible responses in gimbaled multibody systems are discussed. Their origin and physical significance are described in terms of detailed mass and stiffness modeling at actuator/sensor interfaces. Guyan Reduction, Generalized Dynamic Reduction, inadequate mass modeling detail, as well as system mode truncation, are shown to suppress the high gain high frequency response and thereby lose system flexibility important for stability and performance predictions. Model validation by modal survey testing is shown to risk similar loss of accuracy. Difficulties caused by high frequency responses in component mode simulations, such as DISCOS, and also linearized system mode simulations, are described, and approaches for handling these difficulties are discussed.
The Flexible Image Transport System (FITS) has been used by astronomers for over 30 years as a data interchange and archiving format; FITS files are now handled by a wide range of astronomical software packages. Since the FITS format definition document (the "standard") was last printed in this journal in 2001, several new features have been developed and standardized, notably support for 64-bit integers in images and tables, variable-length arrays in tables, and new world coordinate system conventions which provide a mapping from an element in a data array to a physical coordinate on the sky or within a spectrum. The FITS Working Group of the International Astronomical Union has therefore produced this new Version 3.0 of the FITS standard, which is provided here in its entirety. In addition to describing the new features in FITS, numerous editorial changes were made to the previous version to clarify and reorganize many of the sections. Also included are some appendices which are not formally part of the standard. The FITS standard is likely to undergo further evolution, in which case the latest version may be found on the FITS Support Office Web site at http://fits.gsfc.nasa.gov/, which also provides many links to FITS-related resources.
Many countries--reflecting very different geographies, markets, and power systems--are successfully managing high levels of variable renewable energy (RE) on the grid. Australia (South Australia), Denmark, Germany, Ireland, Spain, and the United States (Colorado and Texas), for example, have effectively integrated variable RE utilizing diverse approaches. Analysis of the results from these case studies reveals a wide range of mechanisms that can be used to accommodate high penetrations of variable RE (e.g., from new market designs to centralized planning). Nevertheless, the myriad approaches collectively suggest that governments can best enable variable RE grid integration by implementing best practices in five areas of intervention: lead public engagement, particularly for new transmission; coordinate and integrate planning; develop rules for market evolution that enable system flexibility; expand access to diverse resources and geographic footprint of operations; and improve system operations.
The objective is to develop active model-independent controllers for slewing and vibration control of nonlinear multibody flexible systems, including flexible robots. The topics are presented in viewgraph form and include: passive stabilization; work-energy rate principle; Liapunov theory; displacement feedback; dynamic controller; displacement and acceleration feedback; velocity feedback; displacement feedback; physical interaction; a 6-DOF robot; and simulation results.
Diversifying variable renewable resources by combining wind, solar photovoltaic, and battery assets in a hybrid power plant can increase renewable energy usage efficiency and improve system flexibility, particularly in distributed energy systems. However, the resilience impact of these systems, particularly outage mitigation, can be difficult to quantify due to uncertainty in resource, energy demand, and outage occurrence. Here, this study outlines a framework to quantify the incremental benefit of hybrid power plant assets for reducing loss-of-load expectation during random outage events. Hybrid power plant performance during outages (considering varying duration and severity) is simulated using a Monte Carlo methodology to reflect uncertainty associated with renewable resource, load demand, and outage timing. Results demonstrate the additional incremental value from increasingly hybrid designs, in which relative capacities of wind, solar photovoltaic, and storage assets contribute to lower loss-of-load expectation than the constituent technologies would alone. The value of added wind or solar capacity increases as the plant composition approaches an equal split. The value of added battery capacity depends on the outage duration and severity, but the first 50 MWh of added storage capacity is the most valuable for reducing the loss-of-load expectation for all plant designs.
This paper focuses on synchronized wireless measurement of high-voltage (HV) power system frequency using mobile embedded systems (MESs) integrated with a wireless electric field sensor (WEFS). Unlike traditional synchronized frequency measurement devices, which rely on potential transformers and current transformers physically connected to system elements, a WEFS is used to realize wireless signal acquisition in the vicinity of any HV apparatus. The MES performs real-time frequency estimation using a recursive discrete Fourier transform based algorithm. Network time protocol (NTP) is used for time synchronization, increasing the system flexibility by eliminating global positioning system reliance. An NTP-based synchronized sampling control method is proposed and implemented in MES to compensate the sampling time error caused by local time drift and division residue. The proposed system has the advantages of portability and lower cost, making it highly accessible and useful for a wide array of synchronized frequency measurement applications. Experiment results verify the accuracy and effectiveness of the proposed system.
Alternate aviation fuels for military or commercial use are required to satisfy MIL-DTL-83133F(2008) or ASTM D 7566 (2010) standards, respectively, and are classified as drop-in fuel replacements. To satisfy legacy issues, blends to 50% alternate fuel with petroleum fuels are certified individually on the basis of feedstock. Adherence to alternate fuels and fuel blends requires smart fueling systems or advanced fuel-flexible systems, including combustors and engines without significant sacrifice in performance or emissions requirements. This paper provides preliminary performance (Part A) and emissions and particulates (Part B) combustor sector data for synthetic-parafinic-kerosene- (SPK-) type fuel and blends with JP-8+100 relative to JP-8+100 as baseline fueling.
Alternate aviation fuels for military or commercial use are required to satisfy MIL-DTL-83133F(2008) or ASTM D 7566 (2010) standards, respectively, and are classified as "drop-in" fuel replacements. To satisfy legacy issues, blends to 50% alternate fuel with petroleum fuels are certified individually on the basis of processing and assumed to be feedstock agnostic. Adherence to alternate fuels and fuel blends requires "smart fueling systems" or advanced fuel-flexible systems, including combustors and engines, without significant sacrifice in performance or emissions requirements. This paper provides preliminary performance (Part A) and emissions and particulates (Part B) combustor sector data. The data are for nominal inlet conditions at 225 psia and 800 F (1.551 MPa and 700 K), for synthetic-paraffinic-kerosene- (SPK-) type (Fisher-Tropsch (FT)) fuel and blends with JP-8+100 relative to JP-8+100 as baseline fueling. Assessments are made of the change in combustor efficiency, wall temperatures, emissions, and luminosity with SPK of 0%, 50%, and 100% fueling composition at 3% combustor pressure drop. The performance results (Part A) indicate no quantifiable differences in combustor efficiency, a general trend to lower liner and higher core flow temperatures with increased FT fuel blends. In general, emissions data (Part B) show little differences, but with percent increase in FT-SPK-type fueling, particulate emissions and wall temperatures are less than with baseline JP-8. High-speed photography illustrates both luminosity and combustor dynamic flame characteristics.
Flexibility of traditional generators plays an important role in accommodating the increased variability and uncertainty of wind and solar on the electric power system. Increased flexibility can be achieved with changes to operational practices or upgrades to existing generation. One challenge is in understanding the value of increasing flexibility, and how this value may change given higher levels of variable generation. This study uses a commercial production cost model to measure the impact of generator flexibility on the integration of wind and solar generators. We use a system that is based on two balancing areas in the Western United States with a range of wind and solar penetrations between 15% and 60%, where instantaneous penetration of wind and solar is limited to 80%.