Optical Johnson noise thermometry

A concept is being explored that an optical analog of the electrical Johnson noise may be used to measure temperature independently of emissivity. The concept is that a laser beam may be modulated on reflection from a hot surface by interaction of the laser photons with the thermally agitated conduction electrons or the lattice phonons, thereby adding noise to the reflected laser beam. If the reflectance noise can be detected and quantified in a background of other noise in the optical and signal processing systems, the reflectance noise may provide a noncontact measurement of the absolute surface temperature and may be independent of the surface's emissivity.

Shepard, R. L.↗

STOL ride quality criteria - Passenger acceptance.

The ability to mathematically model human reaction to variables involved in transportation systems offers a very desirable tool both for the prediction of passenger acceptance of proposed systems, and for establishing acceptance criteria for the system designer. As a first step in the development of a general model for STOL systems, a mathematical formulation is presented which accepts as inputs nine variables felt to be important in flight under STOL-type conditions and presents an index of human response as the output. The variables used are three linear motions, three angular motions, pressure, temperature and noise level. The results are used to establish specifications for stability augmentation systems to improve the ride quality of existing STOL aircraft.

Jacobson, I. D.↗

Infrared Imagery of Shuttle (IRIS). Task 2, summary report

End-to-end tests of a 16 element indium antimonide sensor array and 10 channels of associated electronic signal processing were completed. Quantitative data were gathered on system responsivity, frequency response, noise, stray capacitance effects, and sensor paralleling. These tests verify that the temperature accuracies, predicted in the Task 1 study, can be obtained with a very carefully designed electro-optical flight system. Pre-flight and inflight calibration of a high quality are mandatory to obtain these accuracies. Also, optical crosstalk in the array-dewar assembly must be carefully eliminated by its design. Tests of the scaled up tracking system reticle also demonstrate that the predicted tracking system accuracies can be met in the flight system. In addition, improvements in the reticle pattern and electronics are possible, which will reduce the complexity of the flight system and increase tracking accuracy.

Chocol, C. J.↗

X-band system performance of the very large array

The Very Large Array (VLA) is being equipped to receive telemetry from Voyager 2 during the Neptune encounter in 1989. Cryogenically cooled amplifiers are being installed on each of the 27 antennas. These amplifiers are currently a mix of field effect transistors (FETs) and high electron mobility transistors (HEMTs) and exhibit zenith system temperatures that range from 30 to 52 K. The system temperatures and aperture efficiencies determined during the past year are summarized. The nominal values of the noise diode calibration are compared with derived values made under the assumption of a uniform atmosphere over the array. Gain values are determined from observations of unresolved radio sources whose flux densities are well known. The tests suggest that the completed VLA will have a ratio of gain to system temperature that is approximately 4.4 dB above that of a single 64 m antenna of the Deep Space Network.

Ulvestad, J. S.↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Developing a Foundation for Space-Based Two-Phase Thermal Control Systems: Future of 2-Phase Thermal Control

Two-phase thermal control systems in microgravity, with significant density differences between phases, pose challenges for many current and proposed spacecraft systems. Because of the lack of understanding of these effects and the inability to scale multiphase systems in low gravity, NASA generally opts to avoid using two-phase systems for spacecraft despite the significant performance increases and lower mass. The goal of this panel discussion will be to identify key technology gaps and challenges that thermal engineers face today when considering a two-phase thermal management system. The panel discussion will begin with a brief overview of recent and on-going NASA projects designed to elicit a fundamental understanding of gas-liquid two phase behavior as it applies to thermal control systems in the Space environment. The projects/experiments discussed will range from boiling/condensation fundamentals, heat pipes, and cryogenic storage systems. We will identify what fundamental question or questions are being addressed in each case. An overview will be also be presented to address future mission needs and the specific advantages multi-phase systems offer, in particular for low cost planetary science missions and enabling missions in extreme environments. The need for efficient heat transfer with concurrent spatial and temporal temperature stability to reduce thermally-induced noise drives a serious look at multi-phase systems as a solution. Furthermore, missions to environments such as the Venus surface or penetration of ice layers in ocean worlds will likely require them. Time will be allocated at the end of this session to allow comments and questions from attendees. The intent is to use this session as a starting point to advocate for a coordinated technology development effort in this area.

Thermal Control Systems↗

Low Frequency 1/f Noise on QWIPs, nBn, and Superlattice Focal Plane Array

Noise Equivalent Difference Temperature (NE△T) is a standard performance metric for most infrared focal plane array (FPA) systems. The frequency bandwidth and range associated with NE△T is at high frequency and it does not describe the long time noise behavior or the very low frequency noise of the FPA. Very low frequency noise measurement requires data capture that takes longer time duration and sampling interval. This study investigates low frequency noise in QWIP, nBn and LWIR n-type Complementary Barrier Infrared Detector (CBIRD) FPAs. The corner frequencies are extracted from the power spectral density (PSD) as function of frequency. The peak wavelength, quantum efficiency of QWIP detector are 6.2 µm and 2 %, respectively. QWIP FPA has a mean NE△T ~ 25 mK at an operating temperature of 65 K and an integration time of 16 msec. The mean QWIP PSD plot shows a corner frequency of < 0.5 mHz. The nBn FPA with 4 µm cut off and quantum efficiency of 67 % has NE△T ~ 15.6 mK at an integration time ~ 7.52 msec and an operating temperature of 120 K. The nBn has corner frequency of > 50 mHz. Lastly the n-type CBIRD FPA with a 50% cutoff at 8.8 µm and quantum efficiency of ~ 50 % has an NE△T ~ 18.6 mK at an integration time of 1.86 msec and operating temperature 120 K. The superlattice FPA has a corner frequency ~ 10 mHz. The investigation of the tail on the NE△T histogram reveals that its origin is not accounted for entirely by the high noise current, but also it needs the inclusion of lower responsivity for some pixels.

Pepper, B.↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory Microwave SQUID Multiplexing Readout: Cryogenic RF Amplifier and Coaxial Chain Design

The Simons Observatory (SO) is an upcoming polarization-sensitive cosmic microwave background experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of O(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of O(1000), microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to transition edge sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.

47 OTHER INSTRUMENTATION↗

The New Generation Russian VLBI Network

This paper deals with a new project of the Russian VLBI Network dedicated for Universal Time determinations in quasi on-line mode. The basic principles of the network design and location of antennas are explained. Variants of constructing receiving devices, digital data acquisition system, and phase calibration system are specially considered. The frequency ranges and expected values of noise temperature are given.

Finkelstein, Andrey↗

Noise reduction of stochastic density functional theory for metals

Density Functional Theory (DFT) has become a cornerstone in the modeling of metals. However, accurately simulating metals, particularly under extreme conditions, presents two significant challenges. First, simulating complex metallic systems at low electron temperatures is difficult due to their highly delocalized density matrix. Second, modeling metallic warm-dense materials at very high electron temperatures is challenging because it requires the computation of a large number of partially occupied orbitals. This study demonstrates that both challenges can be effectively addressed using the latest advances in linear-scaling stochastic DFT methodologies. Despite the inherent introduction of noise into all computed properties by stochastic DFT, this research evaluates the efficacy of various noise reduction techniques under different thermal conditions. Our observations indicate that the effectiveness of noise reduction strategies varies significantly with the electron temperature. Furthermore, we provide evidence that the computational cost of stochastic DFT methods scales linearly with system size for metal systems, regardless of the electron temperature regime.

Chemistry↗

Use of anomolous thermal imaging effects for multi-mode systems control during crystal growth

Real time image processing techniques, combined with multitasking computational capabilities are used to establish thermal imaging as a multimode sensor for systems control during crystal growth. Whereas certain regions of the high temperature scene are presently unusable for quantitative determination of temperature, the anomalous information thus obtained is found to serve as a potentially low noise source of other important systems control output. Using this approach, the light emission/reflection characteristics of the crystal, meniscus and melt system are used to infer the crystal diameter and a linear regression algorithm is employed to determine the local diameter trend. This data is utilized as input for closed loop control of crystal shape. No performance penalty in thermal imaging speed is paid for this added functionality. Approach to secondary (diameter) sensor design and systems control structure is discussed. Preliminary experimental results are presented.

Wargo, Michael J.↗

Remote Sensing of Sea Surface Temperature from Earth Satellites

Techniques for measuring sea surface temperature using remote sensors in earth orbiting satellites are discussed. Specific reference is made to the infrared sensors carried by the TIROS Operational Satellite. The development of a method to examine a large number of measurements in order to differentiate the temperature effects of clouds is described. It is stated that the system used is completely objective and minimizes the influence of atmospheric absorption, cloud contamination, and instrumental noise on the inferred sea surface temperatures.

Rao, P. K.↗

Frequency addressable beams for land mobile communications

Satellites used for mobile communications need to serve large numbers of small, low cost terminals. The most important parameters affecting the capacity of such systems are the satellite equivalent isotropically radiated power (EIRP) and gain to noise temperature ratio (G/T) and available bandwidth. Satellites using frequency addressed beams provide high EIRP and G/T with high-gain antenna beams that also permit frequency reuse over the composite coverage area. Frequency addressing is easy to implement and compatible with low-cost terminals and offers higher capacity than alternative approaches.

Thompson, J. D.↗

A closed-cycle refrigerator for cooling maser amplifiers below 4 Kelvin

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson (GM/JT) cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch-filled cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a non-tilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 mW of cooling at 2.5 K to 3 W at 4.3 K. Performance of the unit is not significantly affected by physical orientation. The volume occupied by the refrigerator is less than 0.1 cu m. Two JT expansion stages are used to maximize cooling capacity per unit mass flow. The heat exchangers were designed to produce minimum pressure drop in the return gas stream. Pressure drop for the entire JT return circuit is less than 5 kpa at a mass flow of 0.06 g/sec when operating at 2.5 K.

Britcliffe, M.↗

A compact 2.5-Kelvin closed-cycle refrigerator

A helium refrigerator utilizing the Gifford-McMahon/Joule-Thomson cycle was designed and tested to demonstrate the feasibility of using small closed-cycle refrigerators as an alternative to batch filled-cryostats for operating temperatures below 4 K. The systems could be used to cool low-noise microwave maser amplifiers located in large parabolic antennas. These antennas tilt vertically, making conventional liquid-filled dewars difficult to use. The system could also be used for a nontilting beam waveguide antenna to reduce the helium consumption of a liquid helium cryostat. The prototype system is adjustable to provide 700 milliwatts of cooling at 2.5 K to 3 watts at 4.3 K. The performance of the unit is not significantly affected by operation in any physical orientation.