Search NASA⌕ Search

SEARCH · Search NASA

Results for “thyroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Individual doses for super cohort members exposed to atmospheric radioiodine from the Mayak releases with an emphasis on prenatal doses

Time-dependent thyroid doses were reconstructed for 45,837 members of the Southern Urals Population Exposed to Radiation Cohort (SUPER-C) living in the region around the Mayak Production Association facilities in Russia from 131I released to the atmosphere from all relevant exposure pathways. The dose calculations are implemented in a Monte Carlo framework that produces best estimates and stochastic realizations of dose time-histories. The mean thyroid dose from 131I for SUPER-C members was 195 mGy; the median was 65 mGy. Overall, 131I-thyroid doses for about 3.6% of SUPER-C members were larger than 1 Gy. For children born in 1940-1950, the dose was about 10% higher than in previous studies because doses during the prenatal period for 9,117 individuals are included in the current work. Half of the individuals born in the region in 1950–1960 who remained in the study domain through 1972 received 9.4% or more of their total dose during the prenatal period. SUPER-C members residing in areas contaminated by discharges of liquid radioactive releases into the Techa River and the Kyshtym Accident in 1957 received 80% of their thyroid dose from airborne 131I emissions. The uncertainty in the 131I dose estimates is low enough for this approach to be used in regional epidemiological studies.

Dose assessment, 131I, airborne radioactivity, thy↗

Radiation-induced hypothyroidism in patients with breast cancer: a retrospective analysis of 243 cases

This study aims to estimate the incidence of hypothyroidism (HT) and to evaluate the predictors affecting the development of HT after radiotherapy (RT) for breast cancer, with a focus on radiation dose-volumetric parameters. Between 2009 and 2015, 243 patients undergoing RT for breast cancer were retrospectively analyzed. Free triiodothyronine (FT3), free thyroxin (FT4), and thyrotropin (TSH) were monitored before and after RT. The relation between the doses to thyroid gland (D{sub mean}, D{sub max}, D{sub min}), percentage of thyroid volume receiving > 10 Gy, 20 Gy, 30 Gy, 40 Gy, and 50 Gy (V10 to V50), absolute thyroid volume, and HT were analyzed. The risk of HT according to radiation fields and the other clinic factors were also evaluated. The median follow-up was 41 (range; 6 to 130) months. Sixty-seven percent of the patients received RT to the breast/chest wall and ipsilateral supraclavicular fossa. Of 243 patients, 51 (21%) were diagnosed with HT. The median time to the onset of HT was 27 (range; 5 to 64) months. There were no significant relationships observed between D{sub min} or V10 to V50 and HT. The surgery type, clinical stage, nodal status, RT field, D{sub mean}, and D{sub max} were statistically significant predictors for HT in univariate analysis. The D{sub mean} was the only prognostic factor predicting HT in multivariate analysis, and D{sub mean} > 21 Gy was a threshold value for the evolvement of HT. In this study, we present evidence that postoperative irradiation of patients with breast cancer may frequently lead to HT. Patients who have received RT for breast cancer, especially irradiation on the supraclavicular region, may require thyroid function screening after RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-269: Assessing the Precision of Dose Delivery in CBCT-Guided Stereotactic Body Radiation Therapy for Lung and Soft Tissue Metastatic Lesions

Purpose: Ensuring reproducibility of target localization is critical to accurate stereotactic body radiation treatment (SBRT) for lung and soft tissue metastatic lesions. To characterize interfraction variability in set-up and evaluate PTV margins utilized for SBRT, daily CBCTs were used to calculate delivered target and OAR doses compared to those expected from planning. Methods: CBCT images obtained prior to each fraction of SBRT for a lung and thyroid metastatic lesion were evaluated. The target CTV/ITV and OARs on each of 8 CBCT data sets were contoured. Using MIM fusion software and Pinnacle{sup 3} RTP system, delivered dose distribution was reconstructed on each CBCT, utilizing translational shifts performed prior to treatment. Actual delivered vs. expected doses received by target CTV/ITV and adjacent critical structures were compared to characterize accuracy of pre-treatment translational shifts and PTV margins. Results: The planned CTV/ITV D95% and V100% were 4595cGy and 91.47% for the lung lesion, and 3010cGy and 96.34% for the thyroid lesion. Based on CBCT analysis, actual mean D95% and V100% for lung ITV were 4542±344.4cGy and 91.54±3.45%; actual mean D95% and V100% for thyroid metastasis CTV were 3005±25.98cGy and 95.20±2.522%. For the lung lesion, ipsilateral lung V20, heart V32 (cc) and spinal cord (.03 cc) max were 110.15cc, 3.33cc, and 1680cGy vs. 110.27±14.79cc, 6.74±3.76cc, and 1711±46.56cGy for planned vs. delivered doses, respectively. For the thyroid metastatic lesion, esophagus V18, trachea (.03 cc) max, and spinal cord (.03 cc) max were 0.35cc, 2555cGy, and 850cGy vs. 0.16±0.13cc, 2147±367cGy, and 838±45cGy for planned vs. delivered treatments, respectively. Conclusion: Minimal variability in SBRT target lesion dose delivered based on pre-treatment CBCT-based translational shifts suggests tighter PTV margins may be considered to further decrease dose to surrounding critical structures. Guidelines for optimal target alignment during CBCT-guidance for lung and soft tissue metastatic lesions treated with SBRT are being established.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-12: Magnetic Resonance- Guided High-Intensity Focused Ultrasound for Localized Ablation of Head and Neck Tissue Structures: A Feasibility Study in An Animal Model

Purpose: High-intensity focused ultrasound (HIFU) ablation is feasible in the head and neck [1]. This study aims to expand upon these findings to assess the feasibility of treatment planning and monitoring via magnetic resonance imaging (MRI) guidance using a clinical MR-guided HIFU platform. Methods: Two 31 kg pigs were anaesthetized, shaved, and positioned prone on the HIFU table (Sonalleve, Philips Healthcare, Vantaa, Finland). The necks were acoustically coupled to the integrated transducer using gel pads and degassed water. MR imaging verified acoustic coupling and facilitated target selection in the thyroid and thymus. Targets were thermally ablated with 130–200 W of acoustic power over a period of 16 s at a frequency of 1.2 MHz while being monitored through real-time, multi-planar MR-thermometry. Contrast-enhanced MR imaging was used to assess treatment efficacy. Post-treatment, animals were euthanized and sonicated tissues were harvested for histology assessment. Results: MR-thermometry, post-contrast-imaging, and gross pathology demonstrated that the system was capable of causing localized thermal ablation in both the thyroid and the thymus without damaging the aerodigestive tract. In one animal, superficial bruising was observed in the ultrasound beam path. Otherwise, there were no adverse events. Analysis of the tissue histology found regions of damage consistent with acute thermal injury at the targeted locations. Conclusion: It is feasible to use a clinical MR-guided HIFU platform for extracorporeal ablation of porcine head and neck tissues. MR guidance and thermometry are sufficient to target and monitor treatment in the thyroid region, despite the presence of the inhomogeneous aerodigestive tract. Further study is necessary to assess efficacy and survival using a tumor model, and to examine what modifications should be made to the transducer positioning system and associated patient positioning aids to adapt it for clinical head and neck targets.Reference:[1] Esnault et al. (2011). Thyroid, 21(9), 965– 973. Funding support provided by Philips Healthcare. Ari Partanen is a paid employee of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Crystal structures of human sulfotransferases SULT1B1 and SULT1C1 complexed with the cofactor product adenosine-3'- 5'-diphosphate (PAP)

Cytosolic sulfotransferases (SULTs), often referred as Phase II enzymes of chemical defense, are a superfamily of enzymes that catalyze the transfer of a sulfonate group from 3{prime}-phosphoadenosine 5{prime}-phosphosulfate (PAPS) to an acceptor group of substrates. This reaction modulates the activities of a large array of small endogenous and foreign chemicals including drugs, toxic compounds, steroid hormones, and neurotransmitters. In some cases, however, SULTs activate certain food and environmental compounds to mutagenenic and carcinogenic metabolites. Twelve human SULTs have been identified, which are partitioned into three families: SULT1, SULT2 and SULT4. The SULT1 family is further divided in four subfamilies, A, B, C, and E, and comprises eight members (1A1, 1A2, 1A3, 1B1, 1C1, 1C2, 1C3, and 1E1). Despite sequence and structural similarity among the SULTs, the family and subfamily members appear to have different biological function. SULT1 family shows substrate-binding specificity for simple phenols, estradiol, and thyroid hormones, as well as environmental xenobiotics and drugs. Human SULT1B1 is expressed in liver, colon, small intestine, and blood leukocytes, and shows substrate-binding specificity to thyroid hormones and benzylic alcohols. Human SULT1C1 is expressed in the adult stomach, kidney, and thyroid, as well as in fetal kidney and liver. SULT1C1 catalyzes the sulfonation of p-nitrophenol and N-hydroxy-2-acetylaminofluorene in vitro. However, the in vivo function of the enzyme remains unknown. We intend to solve the structures for all of the SULTs for which structural information is not yet available, and compare the structural and functional features of the entire SULT superfamily. Here we report the structures of two members of SULT1 family, SULT1B1 and SULT1C1, both in complex with the product of the PAPS cofactor, adenosine-3{prime}-5{prime}-diphosphate (PAP).

36 MATERIALS SCIENCE↗

Interaction between deca-BDE and hepatic deiodinase in a highly PBDE-exposed bird

Highlights: • Ring-billed gulls breeding in Montreal area are highly exposed to deca-BDE. • We studied biotransformation of deca-BDE and interaction with deiodinases. • No in vitro degradation of deca-BDE was observed using liver microsomes. • Deca-BDE interacted with deiodinase activity at the medium concentration. • Liver deca-BDE concentrations were correlated with plasma thyroid hormone levels. Studies have shown that debromination of the major component in the deca-brominated diphenyl ether mixture (deca-BDE), BDE-209, occurs in vivo in birds. Recent work from our laboratory on breeding ring-billed gulls (Larus delawarensis) exposed to elevated PBDE concentrations in the densely-populated metropolis of Montreal (Canada) further suggests that BDE-209 debromination is potentially catalyzed by deiodinases in liver microsomes. The first objective of this study was to determine if type 1 deiodinase (D1) was involved in the in vitro debromination of BDE-209 in liver microsomes of ring-billed gulls. The second objective was to determine if there was an interaction between D1 and BDE-209 using an in vitro D1 activity assay. No depletion of BDE-209 was observed in gull liver microsomes. A significant 42% increase in total D1 activity was found in gull liver microsomes at the medium BDE-209 concentration (1.0 nM), although not at the low (0.5 nM) or high (2.5 nM) concentrations, suggesting potential non-dose related interaction with D1. Moreover, no correlation was found between total D1 activity in liver microsomes and plasma thyroid hormone levels, although there was a negative relationship between plasma BDE-209 concentrations and FT{sub 3} levels. Results from this study suggest that debromination of BDE-209 did not occur using present in vitro assay conditions, although indicated potential interaction with D1 that may have implication on circulating thyroid hormone status.

54 ENVIRONMENTAL SCIENCES↗

Triiodothyronine promotes the proliferation of epicardial progenitor cells through the MAPK/ERK pathway

Thyroid hormone has important functions in the development and physiological function of the heart. The aim of this study was to determine whether 3,5,3′-Triiodothyronine (T3) can promote the proliferation of epicardial progenitor cells (EPCs) and to investigate the potential underlying mechanism. Our results showed that T3 significantly promoted the proliferation of EPCs in a concentration- and time-dependent manner. The thyroid hormone nuclear receptor inhibitor bisphenol A (100 μmol/L) did not affect T3's ability to induce proliferation. Further studies showed that the mRNA expression levels of mitogen-activated protein kinase 1 (MAPK1), MAPK3, and Ki67 in EPCs in the T3 group (10 nmol/L) increased 2.9-, 3-, and 4.1-fold, respectively, compared with those in the control group (P < 0.05). In addition, the mRNA expression of the cell cycle protein cyclin D1 in the T3 group increased approximately 2-fold compared with the control group (P < 0.05), and there were more EPCs in the S phase of the cell cycle (20.6% vs. 12.0%, P < 0.05). The mitogen-activated protein kinase/extracellular signal-regulated kinase (MAPK/ERK) signaling pathway inhibitor U0126 (10 μmol/L) significantly inhibited the ability of T3 to promote the proliferation of EPCs and to alter cell cycle progression. This study suggested that T3 significantly promotes the proliferation of EPCs, and this effect may be achieved through activation of the MAPK/ERK signaling pathway. - Highlights: • Epicardial progenitor cells were successfully cultured from E12.5 mice. • Thyroid hormone T3 significantly promoted the proliferation of EPCs. • This biological effect may be mediated via activation of the MAPK/ERK pathway.

60 APPLIED LIFE SCIENCES↗

High-throughput screening and chemotype-enrichment analysis of ToxCast phase II chemicals evaluated for human sodium-iodide symporter (NIS) inhibition

In support of the Endocrine Disruptor Screening Program (EDSP), the U.S.EPA's Office of Research and Development (ORD) is developing high-throughput screening (HTS) approaches to identify chemicals that alter target sites in the thyroid hormone (TH) pathway. The sodium iodide symporter (NIS) is a transmembrane glycoprotein that mediates iodide uptake into the thyroid as the initial step of TH biosynthesis. Previously, we screened 293 ToxCast chemicals (ph1v2) using a HEK293T cell line expressing human NIS in parallel radioactive iodide uptake (RAIU) and cell viability assays to identify potential environmental NIS inhibitors. Here, we expanded NIS inhibitor screening for a set of 768 ToxCast Phase II (ph2) chemicals, and applied a novel computational toxicology approach based on the ToxPrint chemotype to identify chemical substructures associated with NIS inhibition. Following single-concentration screening (at 1 × 10 -4 M with a 20% inhibition cutoff), 235 samples (228 chemicals) were further tested in multipleconcentration (1 × 10 -9 - 1 × 10 -4 M) format in both RAIU and cell viability assays. The 167 chemicals that exhibited significant RAIU inhibition were then prioritized using combined RAIU and cell viability responses that were normalized relative to the known NIS inhibitor sodium perchlorate. Some of the highest ranked chemicals, such as PFOS, tributyltin chloride, and triclocarban, have been previously reported to be thyroid disruptors. In addition, several novel chemicals were identified as potent NIS inhibitors. The present results were combined with the previous ph1v2 screening results to produce two sets of binary hit-calls for 1028 unique chemicals, consisting of 273 positives exhibiting significant RAIU inhibition, and 63 positives following application of a cell viability filter. A ToxPrint chemotype-enrichment analysis identified > 20 distinct chemical substructural features, represented in > 60% of the active chemicals, as significantly enriched in each NIS inhibition hit-call space. A shared set of 9 chemotypes enriched in both hit-call sets indicates stable chemotype signals (insensitive to cytotoxicity filters) that can help guide structure-activity relationship (SAR) investigations and inform future research.

54 ENVIRONMENTAL SCIENCES↗

Risk of Developing Second Cancer From Neutron Dose in Proton Therapy as Function of Field Characteristics, Organ, and Patient Age

Purpose: To estimate the risk of a second malignancy after treatment of a primary brain cancer using passive scattered proton beam therapy. The focus was on the cancer risk caused by neutrons outside the treatment volume and the dependency on the patient's age. Methods and Materials: Organ-specific neutron-equivalent doses previously calculated for eight different proton therapy brain fields were considered. Organ-specific models were applied to assess the risk of developing solid cancers and leukemia. Results: The main contributors (>80%) to the neutron-induced risk are neutrons generated in the treatment head. Treatment volume can influence the risk by up to a factor of {approx}2. Young patients are subject to significantly greater risks than are adult patients because of the geometric differences and age dependency of the risk models. Breast cancer should be the main concern for females. For males, the risks of lung cancer, leukemia, and thyroid cancer were significant for pediatric patients. In contrast, leukemia was the leading risk for an adult. Most lifetime risks were <1% (70-Gy treatment). The only exceptions were breast, thyroid, and lung cancer for females. For female thyroid cancer, the treatment risk can exceed the baseline risk. Conclusion: The risk of developing a second malignancy from neutrons from proton beam therapy of a brain lesion is small (i.e., presumably outweighed by the therapeutic benefit) but not negligible (i.e., potentially greater than the baseline risk). The patient's age at treatment plays a major role.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hyperparathyroidism After Irradiation for Childhood Malignancy

Purpose: To examine the occurrence of hyperparathyroidism in a cohort of patients undergoing combined parathyroid and thyroid surgery after previous head-and-neck irradiation for childhood malignancy. Methods and Materials: This is a retrospective cohort study for the years 1996 to 2007. The study group comprised patients undergoing surgery in University of Sydney Endocrine Surgical Unit who had received previous head-and-neck irradiation in childhood and who were identified as having pathologic thyroid and parathyroid characteristics. Results: A total of 53 patients were identified in whom head-and-neck irradiation for the treatment of childhood malignancy had been documented. In each of the cases, thyroid disease was the primary reason for referral for surgery. Five of these patients (10%) were found to exhibit coexisting hyperparathyroidism. The latency period for hyperparathyroidism was less than 20 years in 4 of the 5 cases. There were four conventional parathyroid adenomas and one parathyroid lipoadenoma. All patients exhibited a significant decrease in postoperative calcium levels after surgery. Conclusions: To our knowledge, this is the first study to document the significant risk of hyperparathyroidism after radiation exposure for childhood malignancy. The timeframe for development of disease is much shorter than that published for individuals who have undergone irradiation for benign diseases. High doses of therapeutic radiation at a young age make childhood survivors of malignancy at especially high risk for developing hyperparathyroidism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prone Accelerated Partial Breast Irradiation After Breast-Conserving Surgery: Compliance to the Dosimetry Requirements of RTOG-0413

Purpose: The dosimetric results from our institution's trials of prone accelerated partial breast irradiation are compared with the dosimetric requirements of RTOG-0413. Methods and Materials: Trial 1 and Trial 2 are 2 consecutive trials of prone-accelerated partial breast irradiation. Eligible for both trials were stage I breast cancer patients with negative margins after breast-conserving surgery. The planning target tumor volume (PTV) was created by extending the surgical cavity 2.0 cm for Trial 1 and 1.5 cm for Trial 2, respectively. Contralateral breast, heart, lungs, and thyroid were contoured. Thirty Gray was delivered in five daily fractions of 6 Gy by a three-dimensional conformal radiation therapy technique in Trial 1 and were by image-guided radiation therapy/intensity-modulated radiation therapy in Trial 2. Dosimetric results from the trials are reported and compared with RTOG 0413 requirements. Results: One hundred forty-six consecutive plans were analyzed: 67 left and 79 right breast cancers. The plans from the trials complied with the required >90% of prescribed dose covering 90% of PTV{sub E}VAL (=generated from the PTV by cropping 0.5 cm from the skin edge and excluding the chest wall): V90% was 98.1 {+-} 3.0% (with V100% and V95%, 89.4 {+-} 12.8%, 96.4 {+-} 5.1%, respectively). No significant difference between laterality was found (Student's t test). The dose constraints criteria of the RTOG-0413 protocol for ipsilateral and contralateral lung (V30 <15% and Dmax <3%), heart (V5 <40%), and thyroid (Dmax <3%) were satisfied because the plans showed an average V5% of 0.6% (range, 0-13.4) for heart, an average V30% of 0.6% (range, 0-9.1%) for ipsilateral lung, and <2% maximum dose to the thyroid. However, our partial breast irradiation plans demonstrated a higher dose to contralateral breast than that defined by RTOG constraints, with a median value of maximum doses of 4.1% (1.2 Gy), possibly as a result of contouring differences. Conclusions: Our technique for prone accelerated partial breast irradiation generally satisfied RTOG-0413 requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimizing Late Effects for Patients With Mediastinal Hodgkin Lymphoma: Deep Inspiration Breath-Hold, IMRT, or Both?

Purpose: Hodgkin lymphoma (HL) survivors have an increased risk of cardiovascular disease (CD), lung cancer, and breast cancer. We investigated the risk for the development of CD and secondary lung, breast, and thyroid cancer after radiation therapy (RT) delivered with deep inspiration breath-hold (DIBH) compared with free-breathing (FB) using 3-dimensional conformal RT (3DCRT) and intensity modulated RT (IMRT). The aim of this study was to determine which treatment modality best reduced the combined risk of life-threatening late effects in patients with mediastinal HL. Methods and Materials: Twenty-two patients with early-stage mediastinal HL were eligible for the study. Treatment plans were calculated with both 3DCRT and IMRT on both DIBH and FB planning computed tomographic scans. We reported the estimated dose to the heart, lung, female breasts, and thyroid and calculated the estimated life years lost attributable to CD and to lung, breast, and thyroid cancer. Results: DIBH lowered the estimated dose to heart and lung regardless of delivery technique (P<.001). There was no significant difference between IMRT-FB and 3DCRT-DIBH in mean heart dose, heart V20Gy, and lung V20Gy. The mean breast dose was increased with IMRT regardless of breathing technique. Life years lost was lowest with DIBH and highest with FB. Conclusions: In this cohort, 3DCRT-DIBH resulted in lower estimated doses and lower lifetime excess risks than did IMRT-FB. Combining IMRT and DIBH could be beneficial for a subgroup of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized Volumetric Modulated Arc Therapy Versus 3D-CRT for Early Stage Mediastinal Hodgkin Lymphoma Without Axillary Involvement: A Comparison of Second Cancers and Heart Disease Risk

Purpose: The purpose of this study was to evaluate the risks of second cancers and cardiovascular diseases associated with an optimized volumetric modulated arc therapy (VMAT) planning solution in a selected cohort of stage I/II Hodgkin lymphoma (HL) patients treated with either involved-node or involved-site radiation therapy in comparison with 3-dimensional conformal radiation therapy (3D-CRT). Methods and Materials: Thirty-eight patients (13 males and 25 females) were included. Disease extent was mediastinum alone (n=8, 21.1%); mediastinum plus unilateral neck (n=19, 50%); mediastinum plus bilateral neck (n=11, 29.9%). Prescription dose was 30 Gy in 2-Gy fractions. Only 5 patients had mediastinal bulky disease at diagnosis (13.1%). Anteroposterior 3D-CRT was compared with a multiarc optimized VMAT solution. Lung, breast, and thyroid cancer risks were estimated by calculating a lifetime attributable risk (LAR), with a LAR ratio (LAR{sub VMAT}-to-LAR{sub 3D-CRT}) as a comparative measure. Cardiac toxicity risks were estimated by calculating absolute excess risk (AER). Results: The LAR ratio favored 3D-CRT for lung cancer induction risk in mediastinal alone (P=.004) and mediastinal plus unilateral neck (P=.02) presentations. LAR ratio for breast cancer was lower for VMAT in mediastinal plus bilateral neck presentations (P=.02), without differences for other sites. For thyroid cancer, no significant differences were observed, regardless of anatomical presentation. A significantly lower AER of cardiac (P=.038) and valvular diseases (P<.0001) was observed for VMAT regardless of disease extent. Conclusions: In a cohort of patients with favorable characteristics in terms of disease extent at diagnosis (large prevalence of nonbulky presentations without axillary involvement), optimized VMAT reduced heart disease risk with comparable risks of thyroid and breast cancer, with an increase in lung cancer induction probability. The results are however strongly influenced by the different anatomical presentations, supporting an individualized approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biosensor discovery of thyroxine transport disrupting chemicals

Ubiquitous chemicals may interfere with the thyroid system that is essential in the development and physiology of vertebrates. We applied a surface plasmon resonance (SPR) biosensor-based screening method for the fast screening of chemicals with thyroxine (T4) transport disrupting activity. Two inhibition assays using the main thyroid hormone transport proteins, T4 binding globulin (TBG) and transthyretin (TTR), in combination with a T4-coated biosensor chip were optimized and automated for screening chemical libraries. The transport protein-based biosensor assays were rapid, high throughput and bioeffect-related. A library of 62 chemicals including the natural hormones, polychlorinated biphenyls (PCBs), polybrominated diphenylethers (PBDEs) and metabolites, halogenated bisphenol A (BPA), halogenated phenols, pharmaceuticals, pesticides and other potential environmentally relevant chemicals was tested with the two assays. We discovered ten new active compounds with moderate to high affinity for TBG with the TBG assay. Strikingly, the most potent binding was observed with hydroxylated metabolites of the brominated diphenyl ethers (BDEs) BDE 47, BDE 49 and BDE 99, that are commonly found in human plasma. The TTR assay confirmed the activity of previously identified hydroxylated metabolites of PCBs and PBDEs, halogenated BPA and genistein. These results show that the hydroxylated metabolites of the ubiquitous PBDEs not only target the T4 transport at the TTR level, but also, and to a great extent, at the TBG level where most of the T4 in humans is circulating. The optimized SPR biosensor-based transport protein assay is a suitable method for high throughput screening of large libraries for potential thyroid hormone disrupting compounds.

60 APPLIED LIFE SCIENCES↗

Hydroxylated PBDEs induce developmental arrest in zebrafish

The ubiquitous spread of polybrominated diphenyl ethers (PBDEs) has led to concerns regarding the metabolites of these congeners, in particular hydroxylated PBDEs. There are limited studies regarding the biological interactions of these chemicals, yet there is some concern they may be more toxic than their parent compounds. In this study three hydroxylated PBDEs were assessed for toxicity in embryonic zebrafish: 3-OH-BDE 47, 5-OH-BDE 47, and 6-OH-BDE 47. All three congeners induced developmental arrest in a concentration-dependent manner; however, 6-OH-BDE 47 induced adverse effects at lower concentrations than the other congeners. Furthermore, all three induced cell death; however apoptosis was not observed. In short-term exposures (24–28 hours post fertilization), all hydroxylated PBDEs generated oxidative stress in the region corresponding to the cell death at 5 and 10 ppm. To further investigate the short-term effects that may be responsible for the developmental arrest observed in this study, gene regulation was assessed for embryos exposed to 0.625 ppm 6-OH-BDE 47 from 24 to 28 hpf. Genes involved in stress response, thyroid hormone regulation, and neurodevelopment were significantly upregulated compared to controls; however, genes related to oxidative stress were either unaffected or downregulated. This study suggests that hydroxylated PBDEs disrupt development, and may induce oxidative stress and potentially disrupt the cholinergic system and thyroid hormone homeostasis. -- Highlights: ► OH-PBDEs induce developmental arrest in a concentration-dependent manner. ► Hydroxyl group location influences biological interaction. ► OH-PBDEs induce oxidative stress. ► Thyroid hormone gene regulation was disrupted following exposure. ► To our knowledge, this is the first whole organism study of OH-PBDE toxicity.

60 APPLIED LIFE SCIENCES↗

SU-E-I-49: The Evaluation of Usability of Multileaf Collimator for Diagnostic Radiation in Cephalometric Exposure

Purpose: This study evaluated usability of Multileaf collimator (MLC) for diagnostic radiation in cephalometric exposure using optical stimulated luminance dosimeters (OSLDs) Methods: The MLC material was made alloy tool steel (SKD-11) and the density of it is 7.89g/m3 that is similar to it of steel (Fe, 7.85 g/m3) and the MLC was attached to general radiography unit (Rex-650R, Listem Inc, Korea) for cephalometric exposure. The OSLDs that used were nanoDotTM Dosimeter (Landauer Inc, Glenwood, USA) and we read out OSLDs with micro star system (Landauer Inc, Glenwood, USA). The Optical annealing system contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To measure absorbed dose using OSLDs, was carried out dosimetric characteristics of OSLDs. Based on these, we evaluated dose reduction of critical organ (Eyes, Thyroids) with MLC in cephalometric exposure Results: The dosimetric characteristics were following that batch homogeneity was 1.21% and reproducibility was 0.96% of the coefficient of variation The linearity was that the correlation of between dose and count was fitted by linear function (dose,mGy = 0.00029 × Count, R2 =0.997). The range of angular dependence was from −3.6% to 3.7% variation when each degree was normalized by zero degree. The organ dose of Rt. eye, Lt eye, thyroids were 77.8 μGy, 337.0 μGy, 323.1μGy, respectively in open field and the dose reduction of organ dose was 10.6%(8.3μGy), 12.4 %(42 μGy), 87.1%(281.4μGy) with MLC Conclusion: We certified dose reduction of organ dose in cephalometric exposure. The dose reduction of Eye was 11% because of reduction of field size and it of thyroids was 87% by primary beam shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-59: A Novel Multi-Beam Dynamic IMRT with Fixed-Jaw Technique for Left Breast Cancer Patients with Regional Lymph Nodes Radiotherapy

Purpose: This study was to investigate the dosimetric benefit of a novel intensity modulated radiation therapy (IMRT) technique for irradiating the left breast and regional lymph node (RLN). Methods: The breast and RLN (internal mammary node and periclavicular node) and normal tissue were contoured for 16 consecutive left-sided breast cancer patients previously treated with RT after lumpectomy. Nine equi-spaced fields IMRT (9 -field IMRT), tangential multi-beam IMRT (tangential-IMRT) and IMRT with fixed-jaw technique (FJT-IMRT) were developed and compared with three-dimensional conformal RT (3DCRT). Prescribed dose was 50 Gy in 25 fractions. Dose distributions and dose volume histograms were used to evaluate plans. Results: All IMRTs achieved similar target coverage and substantially reduced heart V30 and V20 compared to the 3DCRT. The average heart mean dose had different changes, which were 9.0Gy for 9-field IMRT, 5.7Gy for tangential-IMRT and 4.2Gy for FJT-IMRT. For the contralateral lung and breast, the 9-field IMRT has the highest mean dose; and the FJT-IMRT and tangential-IMRT had similar lower value. For the thyroid, both 9-field IMRT and FJT-IMRT had similar V30 (20% and 22%) and were significantly lower than that of 3DCRT (34%) and tangential-IMRT (46%). Moreover, the thyroid mean dose of FJT-IMRT is the lowest. For cervical esophagus and humeral head, the FJT-IMRT also had the best sparing. Conclusion: All 9-field IMRT, tangential-IMRT and FJT-IMRT had superiority for targets coverage and substantially reduced the heart volume of high dose irradiation. The FJT-IMRT showed advantages of avoiding the contralateral breast and lung irradiation and decreasing the thyroid, humeral head and cervical esophagus radiation dose at the expense of a slight monitor units (MUs) increasing.

60 APPLIED LIFE SCIENCES↗

SU-F-J-182: Investigation of Systems for Improved Accuracy in Clinical Y-90 Percent Delivered Calculations

Purpose: Y-90 Selective Internal Radiation Therapy (SIRT) is used to treat liver tumors, and by nature has variability in the percent of the intended dose that is actually delivered. To determine the quality of the administration, pre and post activity measurements are taken, and used to infer percent delivered. Vendor specifications indicate the use of an ion chamber to take these measurements. In our work, we investigated the accuracy of ion chambers, and compared them to other detector systems. Methods: We have built phantoms, phantom holders, and protocols, which allow us to measure our Y90 doses with varying apparatuses: a dose calibrator, a Geiger-counter, an ion chamber, a crystal based thyroid probe, and a gamma camera. We have set up a system that has enabled us to gather data by measuring clinical Y90 doses as they are used in the clinic using all of the instrumental methods. Five initial doses (25 measurements/acquisitions) have been taken at the time of this abstract submission. Results: Our initial results show that measurements acquired using scintillation based detectors (thyroid probe and gamma camera) correlate better with the gold standard (i.e. the dose calibrator). Pearson correlations between the dose calibrator measurements and the GM counter, Ion chamber, thyroid probe, and gamma camera were found to be 0.88, 0.83, 0.98, 0.99, respectively. More acquisitions and analysis are planned to determine the precision of the systems, as well as optimal energy window settings. Conclusion: It is likely that current standard practice can be improved using scintillation crystal based detectors. Such systems are more sensitive, can integrate signal, and can use energy discrimination. Furthermore, phantoms can be built to integrate with probe and gamma camera systems that are robust and provide reproducibility. Future work will include expanded acquisition and analysis.

60 APPLIED LIFE SCIENCES↗