Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Global Warming Estimation from MSU

Microwave Sounding Unit (MSU) radiometer observations in Ch 2 (53.74 GHz) from sequential, sun-synchronous, polar-orbiting NOAA satellites contain small systematic errors. Some of these errors are time-dependent and some are time-independent. Small errors in Ch 2 data of successive satellites arise from calibration differences. Also, successive NOAA satellites tend to have different Local Equatorial Crossing Times (LECT), which introduce differences in Ch 2 data due to the diurnal cycle. These two sources of systematic error are largely time independent. However, because of atmospheric drag, there can be a drift in the LECT of a given satellite, which introduces time-dependent systematic errors. One of these errors is due to the progressive chance in the diurnal cycle and the other is due to associated chances in instrument heating by the sun. In order to infer global temperature trend from the these MSU data, we have eliminated explicitly the time-independent systematic errors. Both of the time-dependent errors cannot be assessed from each satellite. For this reason, their cumulative effect on the global temperature trend is evaluated implicitly. Christy et al. (1998) (CSL). based on their method of analysis of the MSU Ch 2 data, infer a global temperature cooling trend (-0.046 K per decade) from 1979 to 1997, although their near nadir measurements yield near zero trend (0.003 K/decade). Utilising an independent method of analysis, we infer global temperature warmed by 0.12 +/- 0.06 C per decade from the observations of the MSU Ch 2 during the period 1980 to 1997.

Prabhakara, C.↗

Gompertzian stochastic model with delay effect to cervical cancer growth

In this paper, a Gompertzian stochastic model with time delay is introduced to describe the cervical cancer growth. The parameters values of the mathematical model are estimated via Levenberg-Marquardt optimization method of non-linear least squares. We apply Milstein scheme for solving the stochastic model numerically. The efficiency of mathematical model is measured by comparing the simulated result and the clinical data of cervical cancer growth. Low values of Mean-Square Error (MSE) of Gompertzian stochastic model with delay effect indicate good fits.

60 APPLIED LIFE SCIENCES↗

Motion tracking in the liver: Validation of a method based on 4D ultrasound using a nonrigid registration technique

Purpose: Treatments like radiotherapy and focused ultrasound in the abdomen require accurate motion tracking, in order to optimize dosage delivery to the target and minimize damage to critical structures and healthy tissues around the target. 4D ultrasound is a promising modality for motion tracking during such treatments. In this study, the authors evaluate the accuracy of motion tracking in the liver based on deformable registration of 4D ultrasound images. Methods: The offline analysis was performed using a nonrigid registration algorithm that was specifically designed for motion estimation from dynamic imaging data. The method registers the entire 4D image data sequence in a groupwise optimization fashion, thus avoiding a bias toward a specifically chosen reference time point. Three healthy volunteers were scanned over several breathing cycles (12 s) from three different positions and angles on the abdomen; a total of nine 4D scans for the three volunteers. Well-defined anatomic landmarks were manually annotated in all 96 time frames for assessment of the automatic algorithm. The error of the automatic motion estimation method was compared with interobserver variability. The authors also performed experiments to investigate the influence of parameters defining the deformation field flexibility and evaluated how well the method performed with a lower temporal resolution in order to establish the minimum frame rate required for accurate motion estimation. Results: The registration method estimated liver motion with an error of 1 mm (75% percentile over all datasets), which was lower than the interobserver variability of 1.4 mm. The results were only slightly dependent on the degrees of freedom of the deformation model. The registration error increased to 2.8 mm with an eight times lower temporal resolution. Conclusions: The authors conclude that the methodology was able to accurately track the motion of the liver in the 4D ultrasound data. The authors believe that the method has potential in interventions on moving abdominal organs such as MR or ultrasound guided focused ultrasound therapy and radiotherapy, pending the method is enabled to run in real-time. The data and the annotations used for this study are made publicly available for those who would like to test other methods on 4D liver ultrasound data.

60 APPLIED LIFE SCIENCES↗

A method for evaluating bias in global measurements of CO 2 total columns from space

We describe a method of evaluating systematic errors in measurements of total column dry-air mole fractions of CO{sub 2} (X{sub CO{sub 2}} ) from space, and we illustrate the method by applying it to the Atmospheric CO{sub 2} Observations from Space retrievals of the Greenhouse Gases Observing Satellite (ACOS-GOSAT) v2.8. The approach exploits the lack of large gradients in X{sub CO{sub 2}} south of 25{degree} S to identify large-scale offsets and other biases in the ACOS-GOSAT data with several retrieval parameters and errors in instrument calibration. We demonstrate the effectiveness of the method by comparing the ACOS-GOSAT data in the Northern Hemisphere with ground truth provided by the Total Carbon Column Observing Network (TCCON). We use the correlation between free-tropospheric temperature and X{sub CO{sub 2}} in the Northern Hemisphere to define a dynamically informed coincidence criterion between the ground-based TCCON measurements and the ACOS-GOSAT measurements. We illustrate that this approach provides larger sample sizes, hence giving a more robust comparison than one that simply uses time, latitude and longitude criteria. Our results show that the agreement with the TCCON data improves after accounting for the systematic errors. A preliminary evaluation of the improved v2.9 ACOS-GOSAT data is also discussed.

54 ENVIRONMENTAL SCIENCES↗

SU-F-BRF-04: Evaluation of Five Commercially-Available Algorithms for Deformable Image Registration

Purpose: Deformable image registration (DIR) is increasingly being used in various clinical applications. Although there are several DIR packages all making successful attempts at modeling complex anatomical changes using even more complex mathematical approximations, they are all subject to various uncertainties. Many studies have attempted to quantify the spatial uncertainty with DIR. This is the first study to compare the uncertainty for interfraction DIR for 5 different commercially-available algorithms. The aim of this study was to benchmark the performance of the most commonlyused DIR algorithms offered through these 5 software packages: Eclipse, MIM, Pinnacle, RaySearch, and Velocity. Methods: A set of 10 virtual H'N phantoms [Pukala et al. MedPhys. 40(11) 2013] with known deformations were used to determine the spatial errors that might be seen when performing DIR. The “ground-truth” deformation vector field (DVF) was compared to the DVF output of the 5 commercially-available algorithms in order to evaluate spatial errors for six regions of interest (ROIs): brainstem, cord, mandible, left parotid, right parotid, and the external body contour. Results: We found that each software package had varying uncertainties with the various ROIs, but were generally all comparable to one another – with mean spatial errors for each algorithm below 3.5 mm for each ROI (averaged across all phantoms). We also found that no single algorithm was the clear winner over the other 4 algorithms. However, at times, we found huge maximum errors in our results (e.g. phantom #9 maximum errors: right parotid = 22.9 mm, external contour = 30.5mm) with the varying DIR algorithms. Conclusion: Although our evaluation was limited to H'N patients, we show that our methods are a single-assessment analysis tool that could be used by any physicist, within any type of facility, to compare their DIR software before initiating widespread use within their daily radiotherapy practice.

60 APPLIED LIFE SCIENCES↗

Cross-Market Price Difference Forecast Using Deep Learning for Electricity Markets

Price forecasting is in the center of decision making in electricity markets. Many researches have been done in forecasting energy prices while little research has been reported on forecasting price difference between day-ahead and realtime markets due to its high volatility, which however plays a critical role in virtual trading. To this end, this paper takes the first attempt to employ novel deep learning architecture with Bidirectional Long-Short Term Memory (LSTM) units to forecast the price difference between day-ahead and real-time markets for the same node. The raw data is collected from PJM market, processed and fed into the proposed network. The Root Mean Squared Error (RMSE) and customized performance metric are used to evaluate the performance of the proposed method. Case studies show that it outperforms the traditional statistical models like ARIMA, and machine learning models like XGBoost and SVR methods in both RMSE and the capability of forecasting the sign of price difference. Additionally, to cross-market price difference forecast, the proposed approach has the potential to be applied to solve other forecasting problems such as price spread forecast in DA market for Financial Transmission Right (FTR) trading purpose.

DA/RT price difference↗

Advancing Solid Earth Science through Improved Atmosphere Modeling

We proposed to investigate and develop better models for the effect of the hydrostatic and water vapor components of the neutral atmosphere on delay for VLBI and GPS by using a Numerical Weather Model to better simulate realistic atmosphere conditions. By using a raytrace calculation through the model atmosphere at the times of actual VLBI observations, the potential improvement in geodetic results can be evaluated. Also, by calculating the actual variation of delays with elevation and azimuth, the errors in current mapping function models can be assessed. The VLBI data to be initially analyzed are the fifteen days of the CONT02 sessions of 2002 October which included eight stations. There are three segments to the research. 1) The PSU/NCAR fifth generation mesoscale numerical weather model (MM5) will be used to provide the state of the atmosphere with highest horizontal resolution of 3 km. 2) A three-dimensional raytrace program will be developed to determine the delays through the model atmosphere at the times and in the directions of the VLBI observations for each of the sites. 3) The VLBI data will be analyzed using both standard models for the atmosphere mapping functions and the mapping functions derived from the NWM raytracing.

Niell, A. E.↗

APSO-enhanced algebraic derivative estimation approach for real-time traffic flow prediction on critical road sections during wildfire evacuation

In rapid-onset disaster scenarios such as wildfires, evacuation traffic often significantly deviates from historical patterns, rendering conventional data-driven forecasting methods less effective. To address this challenge, we propose an improved algebraic derivative estimation (ADE) incorporating particle swarm optimization (PSO) for real-time traffic flow prediction. Our approach dynamically adjusts the ADE prediction time window at each step by minimizing a cost function based on the mean and variance of accumulated forecasting errors within the window, thereby balancing bias and variability. We evaluate the method using traffic data from the January 2025 California wildfires, focusing on key road segments critical for large-scale evacuations. The results demonstrate that our approach surpasses established machine learning and deep learning models—XGBoost, LSTM, and GRU—in predictive accuracy and maintains high computational efficiency. Notably, the proposed method eliminates the need for offline model training. Moreover, rapid PSO-based tuning enables real-time deployment, which provides a crucial advantage in scenarios where evacuation timings and road closures change dynamically. In conclusion, these findings highlight the benefits of the PSO-enhanced ADE framework for emergency traffic management, where rapid, data-sparse forecasts are essential for effective evacuation planning.

Algebraic derivative estimation↗

SU-E-T-483: In Vivo Dosimetry of Conventional and Rotational Intensity Modulated Radiotherapy Using Integral Quality Monitor (IQM)

Purpose: To investigate the accuracy, sensitivity and constancy of integral quality monitor (IQM), a new system for in vivo dosimetry of conventional intensity modulated radiation therapy (IMRT) or rotational volumetric modulated arc therapy (VMAT) Methods: A beta-version IQM system was commissioned on an Elekta Infinity LINAC equipped with 160-MLCs Agility head. The stationary and rotational dosimetric constancy of IQM was evaluated, using five-field IMRT and single-or double-arc VMAT plans for prostate and head-and-neck (H&N) patients. The plans were delivered three times over three days to assess the constancy of IQM response. Picket fence (PF) fields were used to evaluate the sensitivity of detecting MLC leaf errors. A single leaf offset was intentionally introduced during delivery of various PF fields with segment apertures of 3×1, 5×1, 10×1, and 24×1cm2. Both 2mm and 5mm decrease in the field width were used. Results: Repeated IQM measurements of prostate and H&N IMRT deliveries showed 0.4 and 0.5% average standard deviation (SD) for segment-by-segment comparison and 0.1 and 0.2% for cumulative comparison. The corresponding SDs for VMAT deliveries were 6.5, 9.4% and 0.7, 1.3%, respectively. Statistical analysis indicates that the dosimetric differences detected by IQM were significant (p < 0.05) in all PF test deliveries. The largest average IQM signal response of a 2 mm leaf error was found to be 2.1% and 5.1% by a 5mm leaf error for 3×1 cm2 field size. The same error in 24×1 cm2 generates a 0.7% and 1.4% difference in the signal. Conclusion: IQM provides an effective means for real-time dosimetric verification of IMRT/ VMAT treatment delivery. For VMAT delivery, the cumulative dosimetry of IQM needs to be used in clinical practice.

60 APPLIED LIFE SCIENCES↗

Summary: Experimental validation of real-time fault-tolerant systems

Testing and validation of real-time systems is always difficult to perform since neither the error generation process nor the fault propagation problem is easy to comprehend. There is no better substitute to results based on actual measurements and experimentation. Such results are essential for developing a rational basis for evaluation and validation of real-time systems. However, with physical experimentation, controllability and observability are limited to external instrumentation that can be hooked-up to the system under test. And this process is quite a difficult, if not impossible, task for a complex system. Also, to set up such experiments for measurements, physical hardware must exist. On the other hand, a simulation approach allows flexibility that is unequaled by any other existing method for system evaluation. A simulation methodology for system evaluation was successfully developed and implemented and the environment was demonstrated using existing real-time avionic systems. The research was oriented toward evaluating the impact of permanent and transient faults in aircraft control computers. Results were obtained for the Bendix BDX 930 system and Hamilton Standard EEC131 jet engine controller. The studies showed that simulated fault injection is valuable, in the design stage, to evaluate the susceptibility of computing sytems to different types of failures.

Iyer, R. K.↗

Allan deviation computations of a linear frequency synthesizer system using frequency domain techniques

Allan Deviation computations of linear frequency synthesizer systems have been reported previously using real-time simulations. Even though it takes less time compared with the actual measurement, it is still very time consuming to compute the Allan Deviation for long sample times with the desired confidence level. Also noises, such as flicker phase noise and flicker frequency noise, can not be simulated precisely. The use of frequency domain techniques can overcome these drawbacks. In this paper the system error model of a fictitious linear frequency synthesizer is developed and its performance using a Cesium (Cs) atomic frequency standard (AFS) as a reference is evaluated using frequency domain techniques. For a linear timing system, the power spectral density at the system output can be computed with known system transfer functions and known power spectral densities from the input noise sources. The resulting power spectral density can then be used to compute the Allan Variance at the system output. Sensitivities of the Allan Variance at the system output to each of its independent input noises are obtained, and they are valuable for design trade-off and trouble-shooting.

Wu, Andy↗

Deformable Image Registration for Adaptive Radiation Therapy of Head and Neck Cancer: Accuracy and Precision in the Presence of Tumor Changes

Purpose: To compare deformable image registration (DIR) accuracy and precision for normal and tumor tissues in head and neck cancer patients during the course of radiation therapy (RT). Methods and Materials: Thirteen patients with oropharyngeal tumors, who underwent submucosal implantation of small gold markers (average 6, range 4-10) around the tumor and were treated with RT were retrospectively selected. Two observers identified 15 anatomical features (landmarks) representative of normal tissues in the planning computed tomography (pCT) scan and in weekly cone beam CTs (CBCTs). Gold markers were digitally removed after semiautomatic identification in pCTs and CBCTs. Subsequently, landmarks and gold markers on pCT were propagated to CBCTs, using a b-spline-based DIR and, for comparison, rigid registration (RR). To account for observer variability, the pair-wise difference analysis of variance method was applied. DIR accuracy (systematic error) and precision (random error) for landmarks and gold markers were quantified. Time trend of the precisions for RR and DIR over the weekly CBCTs were evaluated. Results: DIR accuracies were submillimeter and similar for normal and tumor tissue. DIR precision (1 SD) on the other hand was significantly different (P<.01), with 2.2 mm vector length in normal tissue versus 3.3 mm in tumor tissue. No significant time trend in DIR precision was found for normal tissue, whereas in tumor, DIR precision was significantly (P<.009) degraded during the course of treatment by 0.21 mm/week. Conclusions: DIR for tumor registration proved to be less precise than that for normal tissues due to limited contrast and complex non-elastic tumor response. Caution should therefore be exercised when applying DIR for tumor changes in adaptive procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of detector dead time on the performance of optical direct-detection communication links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Intelligent Computerized Training System

Intelligent computer-aided training system gives trainees same experience gained from best on-the-job training. Automated system designed to emulate behavior of experienced teacher devoting full time and attention to training novice. Proposes challenging training scenarios, monitors and evaluates trainee's actions, makes meaningful comments in response to errors, reponds to requests for information, gives hints when appropriate, and remembers strengths and weaknesses so it designs suitable exercises. Used to train flight-dynamics officers in deploying satellites from Space Shuttle. Adapted to training for variety of tasks and situations, simply by modifying one or at most two of its five modules. Helps to ensure continuous supply of trained specialists despite scarcity of experienced and skilled human trainers.

Wang, Lui↗

Evaluation of Flow Biosensor Technology in a Chronically-Instrumented Non-Human Primate Model

The Physiology Research Branch of Brooks AFB conducts both human and non-human primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to indentify the particular mechanisms that invoke these responses. Primary investigative research efforts in a non-human primate model require the calculation of total peripheral resistance (TPR), systemic arterial compliance (SAC), and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. We have evaluated commercially available electromagnetic (EMF) and transit-time flow measurement techniques. In vivo and in vitro experiments demonstrated that the average error of these techniques is less than 25 percent for EMF and less than 10 percent for transit-time.

SC Koenig↗

Effect of Detector Dead Time on the Performance of Optical Direct-Detection Communication Links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detect ion sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulted (PPM) channel is studied by analyzing the error probability. It is shown that, when back- ground noise is negligible, the performance of the detector with dead time is similar to that o f a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on background intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗

Root Cause Analysis of the Data Refinement Process – Medical Conditions Capability Resource Tables

The medical system for spaceflight thus far has been designed to support missions in low earth orbit (LEO). Crew capabilities are limited and heavily dependent on the team of medical support staff at Mission Control Center (MCC) to guide diagnosis and management. However, missions to the Moon and Mars will suffer from several constraints that will make this ground support focused approach to care ineffective. In order to update and modify medical system design, NASA has relied on Probabilistic Risk Assessment (PRA) modeling to mitigate medical risk through trade space analysis. Specifically, capability resource tables (CRT’s) were developed to create a dataset of resources required to manage a list of accepted medical conditions significant in exploration spaceflight. With 120 conditions, this dataset contained hundreds of capabilities and thousands of resources with tens of thousands of cells of data. Initially these tables were built in excel for high throughput during development, but ultimately had to be transferred, managed, and modified into the Evidence Library database for modeling purposes. The process of collating and reviewing the Evidence Library revealed numerous errors in the dataset that had to be corrected through iterative changes. Several error types emerged during this process and can be broken into specific classifications defined as “input”, “transcription”, “structural”, “branching”, and “information”. In reviewing these error types through the root cause analysis (RCA) approach, we were able to identify the contributors to these errors which included single data review points, changing product end goals, limited software selection, time constraints and several others. By reviewing and evaluating the underlying causes we can provide possible system improvements that can be implemented for current and future data management in PRA model inputs.

A. Anderson↗

A tightly-coupled domain-decomposition approach for highly nonlinear stochastic multiphysics systems

Multiphysics simulations often involve nonlinear components that are driven by internally generated or externally imposed random fluctuations. When used with a domain-decomposition (DD) algorithm, such components have to be coupled in a way that both accurately propagates the noise between the subdomains and lends itself to a stable and cost-effective temporal integration. We develop a conservative DD approach in which tight coupling is obtained by using a Jacobian-free Newton–Krylov (JfNK) method with a generalized minimum residual iterative linear solver. This strategy is tested on a coupled nonlinear diffusion system forced by a truncated Gaussian noise at the boundary. Enforcement of path-wise continuity of the state variable and its flux, as opposed to continuity in the mean, at interfaces between subdomains enables the DD algorithm to correctly propagate boundary fluctuations throughout the computational domain. Reliance on a single Newton iteration (explicit coupling), rather than on the fully converged JfNK (implicit) coupling, may increase the solution error by an order of magnitude. Increase in communication frequency between the DD components reduces the explicit coupling's error, but makes it less efficient than the implicit coupling at comparable error levels for all noise strengths considered. Finally, the DD algorithm with the implicit JfNK coupling resolves temporally-correlated fluctuations of the boundary noise when the correlation time of the latter exceeds some multiple of an appropriately defined characteristic diffusion time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗