Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

CHROMOSPHERIC DIAGNOSIS WITH Ca II LINES: FORWARD MODELING IN FORWARD SCATTERING. I

This paper presents a synthetic tomography of the quiet solar chromosphere formed by spatial maps of scattering polarization. It has been calculated for the Ca II 8498, 8542, and 3934 Å lines by solving the non-LTE radiative transfer problem of the second kind in a three-dimensional atmosphere model obtained from realistic magneto-hydrodynamical simulations. Our investigation focuses on the linear polarization signals induced by kinematics, radiation field anisotropy, and the Hanle effect in forward-scattering geometry. Thus, instead of considering slit profiles at the limb as normally done in the study of the second solar spectrum, we synthesize and analyze spatial maps of polarization at the disk center. This allows us to understand the spatial signatures of dynamics and magnetic field in the linear polarization in order to discriminate them observationally. Our results suggest some ideas for chromospheric diagnosis that will be developed throughout a series of papers. In particular, Hanle polarity inversion lines and dynamic Hanle diagrams are two concepts introduced in the present work. We find that chromospheric dynamics and magnetic field topology create spatial polarization fingerprints that trace the dynamic situation of the plasma and the magnetic field. This allows us to reconstruct the magnetic field intensity in the middle chromosphere using Stokes V along grooves of null linear polarization. We finally address the problems of diagnosing Hanle saturation and kinematic amplification of scattering signals using Hanle diagrams.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel computer-aided lung nodule detection system for CT images

Purpose: The paper presents a complete computer-aided detection (CAD) system for the detection of lung nodules in computed tomography images. A new mixed feature selection and classification methodology is applied for the first time on a difficult medical image analysis problem. Methods: The CAD system was trained and tested on images from the publicly available Lung Image Database Consortium (LIDC) on the National Cancer Institute website. The detection stage of the system consists of a nodule segmentation method based on nodule and vessel enhancement filters and a computed divergence feature to locate the centers of the nodule clusters. In the subsequent classification stage, invariant features, defined on a gauge coordinates system, are used to differentiate between real nodules and some forms of blood vessels that are easily generating false positive detections. The performance of the novel feature-selective classifier based on genetic algorithms and artificial neural networks (ANNs) is compared with that of two other established classifiers, namely, support vector machines (SVMs) and fixed-topology neural networks. A set of 235 randomly selected cases from the LIDC database was used to train the CAD system. The system has been tested on 125 independent cases from the LIDC database. Results: The overall performance of the fixed-topology ANN classifier slightly exceeds that of the other classifiers, provided the number of internal ANN nodes is chosen well. Making educated guesses about the number of internal ANN nodes is not needed in the new feature-selective classifier, and therefore this classifier remains interesting due to its flexibility and adaptability to the complexity of the classification problem to be solved. Our fixed-topology ANN classifier with 11 hidden nodes reaches a detection sensitivity of 87.5% with an average of four false positives per scan, for nodules with diameter greater than or equal to 3 mm. Analysis of the false positive items reveals that a considerable proportion (18%) of them are smaller nodules, less than 3 mm in diameter. Conclusions: A complete CAD system incorporating novel features is presented, and its performance with three separate classifiers is compared and analyzed. The overall performance of our CAD system equipped with any of the three classifiers is well with respect to other methods described in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction and resulted in statistically not significantly different segmentation error indices (ANOVA test, significance level of 0.05). Conclusions: All three experts were able to produce liver segmentations with low error rates. User interaction time savings of up to 71% compared to a 2D refinement approach demonstrate the utility and potential of our approach. The system offers a range of different tools to manipulate segmentation results, and some users might benefit from a longer learning phase to develop efficient segmentation refinement strategies. The presented approach represents a generally applicable segmentation approach that can be applied to many medical image segmentation problems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variable order spherical harmonic expansion scheme for the radiative transport equation using finite elements

Highlights: {yields} We developed a variable order global basis scheme to solve light transport in 3D. {yields} Based on finite elements, the method can be applied to a wide class of geometries. {yields} It is computationally cheap when compared to the fixed order scheme. {yields} Comparisons with local basis method and other models demonstrate its accuracy. {yields} Addresses problems encountered n modeling of light transport in human brain. - Abstract: We propose the P{sub N} approximation based on a finite element framework for solving the radiative transport equation with optical tomography as the primary application area. The key idea is to employ a variable order spherical harmonic expansion for angular discretization based on the proximity to the source and the local scattering coefficient. The proposed scheme is shown to be computationally efficient compared to employing homogeneously high orders of expansion everywhere in the domain. In addition the numerical method is shown to accurately describe the void regions encountered in the forward modeling of real-life specimens such as infant brains. The accuracy of the method is demonstrated over three model problems where the P{sub N} approximation is compared against Monte Carlo simulations and other state-of-the-art methods.

97 MATHEMATICS AND COMPUTING↗

Internal curing of cement pastes by means of superabsorbent polymers visualized by neutron tomography

Highlights: • The kinetics of water release from SAPs were studied by neutron tomography. • The time window for internal curing was linked to the water release from SAPs. • The water release links to the SAP effectiveness to mitigate autogenous shrinkage. • One SAP type was effective while another prematurely released its stored water. Superabsorbent polymers (SAPs) are used to counteract self-desiccation in order to mitigate autogenous shrinkage, a problem in cementitious systems with a low water-to-cement ratio. The release kinetics during internal curing are of importance as not all SAP types are able to efficiently mitigate autogenous shrinkage. In this study, neutron tomography is used to study and visualize the water release kinetics over time. Per-voxel analysis of the time-attenuation curve was performed using piecewise-constant functions. Two different SAP types were studied, one being able to mitigate autogenous shrinkage and one quickly releasing its stored water after final setting. The tomography results correspond to autogenous shrinkage measurements and nuclear magnetic resonance tests. The visualization provides information on the time of water release by the SAPs after setting and the time window of internal curing. This opens additional insights towards the application of SAPs in the construction sector and provides information on the mechanism of internal curing.

36 MATERIALS SCIENCE↗

Stellar and Accretion Disk Parameters of the Close Binary HD 50526

We present a photometric and spectroscopic study of HD 50526, an ellipsoidal binary member of the group Double Periodic Variable stars. Performing data mining in photometric surveys and conducting new spectroscopic observations with several spectrographs during 2008–2015, we obtained orbital and stellar parameters of the system. The radial velocities were analyzed with the genetic PIKAIA algorithm, whereas Doppler tomography maps for the Hα and Hβ lines were constructed with the Total Variation Minimization code. An optimized simplex algorithm was used to solve the inverse problem adjusting the light curve with the best stellar parameters for the system. We find an orbital period of 6.ͩ701 ± 0.ͩ001 and a long photometric cycle of 191 ± 2 days. We detected the spectral features of the coldest star and modeled it with a logg=2.79±0.02 dex giant of mass 1.13 ± 0.02 M {sub ⊙} and effective temperature 10500 ± 125 K. In addition, we determine a mass ratio q = 0.206 ± 0.033 and that the hot star is a B-type dwarf of mass 5.48 ± 0.02 M {sub ⊙}. The V-band orbital light curve can be modeled including the presence of an accretion disk around the hotter star. This fills the Roche lobe of the hotter star and has a radius 14.74 ± 0.02 R {sub ⊙} and the temperature at the outer edge is 9400 K. Two bright spots located in the disk account for the global morphology of the light curve. The Doppler tomography maps of Hα and Hβ reveal complex structures of mass fluxes in the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Closed-Form Approximation of the Total Variation Proximal Operator

Total variation (TV) is a widely used function for regularizing imaging inverse problems that is particularly appropriate for images whose underlying structure is piecewise constant. TV regularized optimization problems are typically solved using proximal methods, but the way in which they are applied is constrained by the absence of a closed-form expression for the proximal operator of the TV function. A closed-form approximation of the TV proximal operator has previously been proposed, but its accuracy was not theoretically explored in detail. Here, we address this gap by making several new theoretical contributions, proving that the approximation leads to a proximal operator of some convex function, it is equivalent to a gradient descent step on a smoothed version of TV, and that its error can be fully characterized and controlled with its scaling parameter. We experimentally validate our theoretical results on image denoising and sparse-view computed tomography (CT) image reconstruction.

97 MATHEMATICS AND COMPUTING↗

Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

60 APPLIED LIFE SCIENCES↗

In-situ 4D visualization and analysis of temperature-driven creep in an oil shale propped fracture

Here, the proppant embedment due to creep in shales is a known issue affecting the useable lifetime of wells in unconventional oil and gas recovery. One of the factors influencing creep is the presence of organics, whose properties can be very sensitive to temperature. In this work we investigated for the first time the role of temperature-induced creep increase in proppant embedment in an organics-rich Green River oil shale sample via in-situ synchrotron X-ray micro-computed tomography. We observed that temperatures as low as 75 °C already induce fast creep, with a fracture aperture closing rate of 13 μm/h and a loss of fracture conductivity rate of 8.7%/h, due only to proppant embedment, in the measured interval at the first heating stage. Local displacement data analysis provided evidence for markedly plastic deformation around the proppant-shale contacts, in contrast with the brittle proppant embedment observed on more cemented and less organics-rich shales at room temperature. The results highlight how the problem of temperature-dependent mechanical behavior might be more important than previously thought, in shales with a high content in organics, and that in-situ micro-imaging techniques can play a key role in understanding the underlying mechanisms, contributing to solve creep-related problems associated with hydraulic fracturing in complex scenarios.

02 PETROLEUM↗

On the interplay between relaxation, defect formation, and atomic Sn distribution in Ge{sub (1−x)}Sn{sub (x)} unraveled with atom probe tomography

Ge{sub (1−x)}Sn{sub (x)} has received a lot of interest for opto-electronic applications and for strain engineering in advanced complementary-metal-oxide-semiconductor technology, because it enables engineering of the band gap and inducing strain in the alloy. To target a reliable technology for mass application in microelectronic devices, the physical problem to be addressed is to unravel the complex relationship between strain relaxation (as induced by the growth of large layer thicknesses or a thermal anneal) and defect formation, and/or stable Sn-cluster formation. In this paper, we study the onset of Sn-cluster formation and its link to strain relaxation using Atom Probe Tomography (APT). To this end, we also propose a modification of the core-linkage [Stephenson et al., Microsc. Microanal. 13, 448 (2007)] cluster analysis method, to overcome the challenges of limited detection efficiency and lateral resolution of APT, and the quantitative assessment for very small clusters (<40 atoms) embedded in a random distribution of Sn-atoms. We concluded that the main relaxation mechanism for these layers is defect generation (misfit dislocations, threading dislocations, etc.), irrespective of the cause (thickness of layer or thermal anneal) of relaxation and is independent of the cluster formation. The low thermodynamic solubility limit of Sn in Ge seems to be the driving force for Sn-cluster formation. Finally, we also discuss the spatial distribution of Sn in clusters and relate them to the theoretically predicted stable Sn clusters [Ventura et al., Phys. Rev. B 79, 155202 (2009)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast and noise-tolerant determination of the center of rotation in tomography

High-quality tomographic reconstruction is not possible without the accurate localization of the center of rotation. Poor localization leads to artifacts in the data and can even cause reconstructions to fail. There are many approaches to solving this problem, some of which involve the collection of full sinograms, or even provisional tomographic reconstructions, in order to determine the center of rotation. Here, a simple method based on the expected symmetry of the Fourier transform of summed projections approximately 180° apart is presented; unlike cross-correlation methods, it requires only a single Fourier transform to compute, and uses mainly low spatial frequency information which is less susceptible to noise. This approach is shown to be fast, and robust against poor signal-to-noise as well as to projection images acquired at angles that are not exactly 180° apart. This rapid method can be useful as a first step in the processing of tomographic data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D Optical Coherence Tomography image processing in BISCAP: characterization of biofilm structure and properties

Abstract Motivation BISCAP is a state-of-the-art tool for automatically characterizing biofilm images obtained from Optical Coherence Tomography. Limited availability of other software tools is reported in the field. BISCAP’s first version processes 2D images only. Processing 3D images is a problem of greater scientific relevance since it deals with the entire structure of biofilms instead of their 2D slices. Results Building on the image-processing principles and algorithms proposed earlier for 2D images, these were adapted to the 3D case, and a more general implementation of BISCAP was developed. The primary goal concerns the extension of the initial methodology to incorporate the depth axis in 3D images; multiple improvements were also made to boost computational performance. The calculation of structural properties and visual outputs was extended to offer new insights into the 3D structure of biofilms. BISCAP was tested using 3D images of biofilms with different morphologies, consistently delivering accurate characterizations of 3D structures in a few minutes using standard laptop machines. Low user dependency is required for image analysis. Availability and implementation BISCAP is available from https://github.com/diogonarciso/BISCAP. All images used in the tutorials and the validation examples are available from https://web.fe.up.pt/∼fgm/biscap3d.

Narciso, Diogo A. C. (ORCID:0000000227767477)↗

Nanoscale x-ray and electron tomography

We present that three-dimensional (3D) tomographic imaging of the structural, chemical, and physical properties of a material provides key knowledge that links the structure of a material to both its processing and structure that is central to studies across a broad spectrum of materials. For many decades, tomography using x-rays or electrons has proven to be an essential 3D characterization tool. In recent years, advances in technology have significantly pushed the envelope of these techniques in many respects, enabling new imaging capabilities at the nanometer and atomic scale. This article highlights several such developments in nanoscale x-ray and electron tomography. The five articles that appear in this issue of MRS Bulletin discuss research frontiers that include multimodal x-ray tomography at the nanoscale, x-ray spectroscopic tomography, dark-field x-ray microscopy, electron nanotomography for functional nanomaterials, and atomistic imaging by electron tomography. Lastly, these articles give a holistic view of the status of these techniques and promising future directions, as well highlighting their applications for scientific problems.

36 MATERIALS SCIENCE↗

Synchrotron radiation - Applications in the earth sciences

Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.

Bassett, W. A.↗

An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography

Purpose: Bioluminescence tomography (BLT) provides an effective tool for monitoring physiological and pathological activities in vivo. However, the measured data in bioluminescence imaging are corrupted by noise. Therefore, regularization methods are commonly used to find a regularized solution. Nevertheless, for the quality of the reconstructed bioluminescent source obtained by regularization methods, the choice of the regularization parameters is crucial. To date, the selection of regularization parameters remains challenging. With regards to the above problems, the authors proposed a BLT reconstruction algorithm with an adaptive parameter choice rule. Methods: The proposed reconstruction algorithm uses a diffusion equation for modeling the bioluminescent photon transport. The diffusion equation is solved with a finite element method. Computed tomography (CT) images provide anatomical information regarding the geometry of the small animal and its internal organs. To reduce the ill-posedness of BLT, spectral information and the optimal permissible source region are employed. Then, the relationship between the unknown source distribution and multiview and multispectral boundary measurements is established based on the finite element method and the optimal permissible source region. Since the measured data are noisy, the BLT reconstruction is formulated as l{sub 2} data fidelity and a general regularization term. When choosing the regularization parameters for BLT, an efficient model function approach is proposed, which does not require knowledge of the noise level. This approach only requests the computation of the residual and regularized solution norm. With this knowledge, we construct the model function to approximate the objective function, and the regularization parameter is updated iteratively. Results: First, the micro-CT based mouse phantom was used for simulation verification. Simulation experiments were used to illustrate why multispectral data were used rather than monochromatic data. Furthermore, the study conducted using an adaptive regularization parameter demonstrated our ability to accurately localize the bioluminescent source. With the adaptively estimated regularization parameter, the reconstructed center position of the source was (20.37, 31.05, 12.95) mm, and the distance to the real source was 0.63 mm. The results of the dual-source experiments further showed that our algorithm could localize the bioluminescent sources accurately. The authors then presented experimental evidence that the proposed algorithm exhibited its calculated efficiency over the heuristic method. The effectiveness of the new algorithm was also confirmed by comparing it with the L-curve method. Furthermore, various initial speculations regarding the regularization parameter were used to illustrate the convergence of our algorithm. Finally, in vivo mouse experiment further illustrates the effectiveness of the proposed algorithm. Conclusions: Utilizing numerical, physical phantom and in vivo examples, we demonstrated that the bioluminescent sources could be reconstructed accurately with automatic regularization parameters. The proposed algorithm exhibited superior performance than both the heuristic regularization parameter choice method and L-curve method based on the computational speed and localization error.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

Fishbone activity in experimental advanced superconducting tokamak neutral beam injection plasma

Repetitive fishbones near the trapped ion procession frequency were observed for the first time in the neutral beam injection high confinement plasmas in Experimental Advanced Superconducting Tokamak (EAST) tokamak, and diagnosed using a solid-state neutral particle analyzer based on a compact silicon photodiode together with an upgraded high spatial-temporal-resolution multi-arrays soft X-ray (SX) system. This 1/1 typical internal kink mode propagates in the ion-diamagnetism direction with a rotation speed faster than the bulk plasma in the plasma frame. From the SX measurements, this mode frequency is typical of chirping down and the energetic particle effect related to the twisting mode structure. This ion fishbone was found able to trigger a multiple core sawtooth crashes with edge-2/1 sideband modes, as well as to lead to a transition from fishbone to long lived saturated kink mode to fishbone. Furthermore, using SX tomography, a correlation between mode amplitude and mode frequency was found. Finally, a phenomenological prey–predator model was found to reproduce the fishbone nonlinear process well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗