Search NASA⌕ Search

SEARCH · Search NASA

Results for “tortuosity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The narrow pulse approximation and long length scale determination in xenon gas diffusion NMR studies of model porous media

We report a systematic study of xenon gas diffusion NMR in simple model porous media, random packs of mono-sized glass beads, and focus on three specific areas peculiar to gas-phase diffusion. These topics are: (i) diffusion of spins on the order of the pore dimensions during the application of the diffusion encoding gradient pulses in a PGSE experiment (breakdown of the narrow pulse approximation and imperfect background gradient cancellation), (ii) the ability to derive long length scale structural information, and (iii) effects of finite sample size. We find that the time-dependent diffusion coefficient, D(t), of the imbibed xenon gas at short diffusion times in small beads is significantly affected by the gas pressure. In particular, as expected, we find smaller deviations between measured D(t) and theoretical predictions as the gas pressure is increased, resulting from reduced diffusion during the application of the gradient pulse. The deviations are then completely removed when water D(t) is observed in the same samples. The use of gas also allows us to probe D(t) over a wide range of length scales and observe the long time asymptotic limit which is proportional to the inverse tortuosity of the sample, as well as the diffusion distance where this limit takes effect (approximately 1-1.5 bead diameters). The Pade approximation can be used as a reference for expected xenon D(t) data between the short and the long time limits, allowing us to explore deviations from the expected behavior at intermediate times as a result of finite sample size effects. Finally, the application of the Pade interpolation between the long and the short time asymptotic limits yields a fitted length scale (the Pade length), which is found to be approximately 0.13b for all bead packs, where b is the bead diameter. c. 2002 Elsevier Sciences (USA).

NASA Discipline Life Sciences Technologies↗

The Fractal-based Analysis of the Regulation of Vascular Remodeling in the Quail Chorioallantoic Membrane

Critical to the advancement of space exploration is the safety and well being of astronauts while in space. This study focuses on the second highest of NASA-defined risk categories for human space exploration, cardiovascular alterations. Current research of this problem is being tackled by investigating angiogenesis through vascular remodeling. Angiogenesis is the growth and formation of new blood vessels. Angiogenesis is an important part of maintaining normal development and bodily functions. The loss of control of this process, either insufficient or excessive vascular growth, is considered a common denominator in many diseases, such as cancer, diabetes, and coronary artery disease. Objectives are presently being met by observing the effects of various regulators, like thrombospondin 1 (TSP-1) and a novel vessel tortuosity factor (TF), through the use of the chorioallantoic membrane (CAM) of Japanese quail embryos, which enables the direct optical imaging of 2-dimensional vascular branching trees. Research within the CAM is being performed to deduce numerous methods of regulating vessel growth. This project centers on the ability of a novel vessel regulator to affect angiogenesis. For example, it is hypothesized that the TSP-1 will inhibit the growth of CAM vasculature. Fractal/VESGEN-based techniques and PTV analysis are the methodologies used to investigate vascular differentiation. This tactic is used to quantify results and measure the growth patterns and morphology of blood vessels. The regulatory mechanisms posed by this vessel regulator can be deduced by alterations found within the vasculature patterns of quail embryos.

Smith, Genee S.↗

Variations in the Sea Ice Edge and the Marginal Ice Zone on Different Spatial Scales as Observed from Different Satellite Sensor

The Marginal sea Ice Zone (MIZ) and the sea ice edge are the most dynamic areas of the sea ice cover. Knowledge of the sea ice edge location is vital for routing shipping in the polar regions. The ice edge is the location of recurrent plankton blooms, and is the habitat for a number of animals, including several which are under severe ecological threat. Polar lows are known to preferentially form along the sea ice edge because of induced atmospheric baroclinicity, and the ice edge is also the location of both vertical and horizontal ocean currents driven by thermal and salinity gradients. Finally, sea ice is both a driver and indicator of climate change and monitoring the position of the ice edge accurately over long time periods enables assessment of the impact of global and regional warming near the poles. Several sensors are currently in orbit that can monitor the sea ice edge. These sensors, though, have different spatial resolutions, different limitations, and different repeat frequencies. Satellite passive microwave sensors can monitor the ice edge on a daily or even twice-daily basis, albeit with low spatial resolution - 25 km for the Special Sensor Microwave Imager (SSM/I) or 12.5 km for the Advanced Microwave Scanning Radiometer (AMSR-E). Although special methods exist that allow the detection of the sea ice edge at a quarter of that nominal resolution (PSSM). Visible and infrared data from the Advanced Very High Resolution Radiometer (AVHRR) and from the Moderate Resolution Imaging Spectroradiometer (MODIS) provide daily coverage at 1 km and 250 m, respectively, but the surface observations me limited to cloud-free periods. The Landsat 7 Enhanced Thematic Mapper (ETM+) has a resolution of 15 to 30 m but is limited to cloud-free periods as well, and does not provide daily coverage. Imagery from Synthetic Aperture Radar (SAR) instruments has resolutions of tens of meters to 100 m, and can be used to distinguish open water and sea ice on the basis of surface and volume scattering characteristics. The Canadian RADARSAT C-band SAR provides data that cover the Arctic Ocean and the MIZ every 3 days. A change-point detection approach was utilized to obtain an ice edge estimate from the RADARSAT data The Quickscat scatterometer provides ice edge information with a resolution of a few kilometers on a near-daily basis. During portions of March and April of 2003 a series of aircraft flights were conducted over the ice edge in the Bering Sea carrying the Polarimetric Scanning Radiometer (PSR), which provides spectral coverage identical with the AMSR-E instrument at a resolution of 500 meters. In this study we investigated these different data sets and analyzed differences in their definition of the sea ice edge and the marginal ice zone and how these differences as well as their individual limitations affect the monitoring of the ice edge dynamics. We also examined how the nature of the sea ice edge, including its location, compactness and shape, changes over the seasons. Our approach was based on calculation of distances between ice edges derived from the satellite and aircraft data sets listed above as well as spectral coherence methods and shape parameters such as tortuosity, curvature, and fractional dimension.

Markus, Thorsten↗

Triamcinolone Acetonide Selectively Inhibits Angiogenesis in Small Blood Vessels and Decreases Vessel Diameter within the Vascular Tree

The steroid triamcinolone acetonide (TA) is a potent anti-angiogenesis drug used to treat retinal vascular diseases that include diabetic retinopathy, vascular occlusions and choroidal neovascularization. To quantify the effects of TA on branching morphology within the angiogenic microvascular tree of the chorioallantoic membrane (CAM) of quail embryos. Increasing concentrations of TA (0-16 ng/ml) were applied topically on embryonic day 7 (E7) to the chorioallantoic membrane (CAM) of quail embryos cultured in Petri dishes, and incubated for an additional 24 or 48 hours until fixation. Binary (black/white) microscopic images of arterial end points were quantified by VESGEN software (for Generational Analysis of Vessel Branching) to obtain major vascular parameters that include vessel diameter (Dv), fractal dimension (Df), tortuosity (Tv) and densities of vessel area, length, number and branch point (Av, Lv, Nv and Brv). For assessment of specific changes in vascular morphology induced by TA, the VESGEN software automatically segmented the vascular tree into branching generations (G1...G10) according to changes in vessel diameter and branching. Vessel density decreased significantly up to 34% as the function of increasing concentration of TA according to Av, Lv, Brv, Nv and Df. TA selectively inhibited the growth of new, small vessels, because Lv decreased from 13.14plus or minus 0.61 cm/cm2 for controls to 8.012 plus or minus 0.82 cm/cm2 at 16 ng TA/ml in smaller branching generations (G7-G10), and for Nv from 473.83 plus or minus 29.85 cm(-)2 to 302.32 plus or minus 33.09 cm-()2. In contrast, vessel diameter (Dv) decreased throughout the vascular tree (G1-G10).

McKay, Terri L.↗

VESGEN Software for Mapping and Quantification of Vascular Regulators

VESsel GENeration (VESGEN) Analysis is an automated software that maps and quantifies effects of vascular regulators on vascular morphology by analyzing important vessel parameters. Quantification parameters include vessel diameter, length, branch points, density, and fractal dimension. For vascular trees, measurements are reported as dependent functions of vessel branching generation. VESGEN maps and quantifies vascular morphological events according to fractal-based vascular branching generation. It also relies on careful imaging of branching and networked vascular form. It was developed as a plug-in for ImageJ (National Institutes of Health, USA). VESGEN uses image-processing concepts of 8-neighbor pixel connectivity, skeleton, and distance map to analyze 2D, black-and-white (binary) images of vascular trees, networks, and tree-network composites. VESGEN maps typically 5 to 12 (or more) generations of vascular branching, starting from a single parent vessel. These generations are tracked and measured for critical vascular parameters that include vessel diameter, length, density and number, and tortuosity per branching generation. The effects of vascular therapeutics and regulators on vascular morphology and branching tested in human clinical or laboratory animal experimental studies are quantified by comparing vascular parameters with control groups. VESGEN provides a user interface to both guide and allow control over the users vascular analysis process. An option is provided to select a morphological tissue type of vascular trees, network or tree-network composites, which determines the general collections of algorithms, intermediate images, and output images and measurements that will be produced.

Parsons-Wingerter, Patricia A.↗

Development of Polyimide Foam for Aircraft Sidewall Applications

In this paper, the use of polyimide foam as a lining in double panel applications is considered. It is being investigated here as a replacement for aircraft grade glass fiber and has a number of attractive functional attributes, not the least of which is its high fire resistance. The test configuration studied here consisted of two 1mm (0.04 in.) thick, flat aluminum panels separated by 12.7 cm (5.0 in.) with a 7.6 cm (3.0 in.) thick layer of foam centered in that space. Random incidence transmission loss measurements were conducted on this buildup, and conventional poro-elastic models were used to predict the performance of the lining material. Results from two densities of foam are considered. The Biot parameters of the foam were determined by a combination of direct measurement (for density, flow resistivity and Young s modulus) and inverse characterization procedures (for porosity, tortuosity, viscous and thermal characteristic length, Poisson s ratio and loss factor). The inverse characterization procedure involved matching normal incidence standing wave tube measurements of absorption coefficient and transmission loss of the isolated foam with finite element predictions. When the foam parameters determined in this way were used to predict the performance of the complete double panel system, reasonable agreement was obtained between the measured transmission loss and predictions made using a commercial statistical energy analysis code.

Silcox, Richard↗

Fluid Shifts Before, During, and After Prolonged Space Flight and their Association with Intracranial Pressure and Visual Impairment

With the conclusion of the Space Shuttle program, NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed in Space Shuttle crewmembers after their short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound changes in vision, some with objective structural and functional findings such as papilledema and choroidal folds on ophthalmologic examination. Globe flattening, optic nerve sheath dilatation, optic nerve tortuosity, and other findings have been noted in imaging studies. This pattern is referred to as visual impairment and intracranial pressure (VIIP) syndrome. The VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) is associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been systematically tested. The purpose of this study is to objectively characterize the fluid distribution and compartmentalization associated with long-duration space flight, and to correlate the findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, can be predicted by crewmember baseline data and responses to acute hemodynamic manipulations (such as head-down tilt tests) obtained before flight. Lastly, we will evaluate the patterns of fluid distribution in astronaut subjects on the ISS during the use of lower body negative pressure (LBNP) and respiratory maneuvers to characterize and explain general and individual responses during space flight.

Stenger, M.↗

Fluid Shifts

NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration space flight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's pre-flight condition and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. This study has been selected for flight implementation and is one of the candidate investigations being considered for the one year mission.

Stenger, Michael↗

Fluid Shifts

NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low-Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 50% of ISS astronauts experienced more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's preflight conditions and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. METHODS: We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome.

Stenger, M.↗

Ames Infusion Stories for NASA Annual Technology Report

These are short (2-page) high-level summaries of technologies that have been infused - i.e., taken the next level. For example, 3DMAT started off as a Center Innovation Fund (CIF) project and graduated to the Game-changing Program (GCD), where it is being prepared for use in Orion. The Nano Entry System similarly started as CIF and graduated to GCD. The High Tortuosity Carbon Dioxide Conversion Device also started off as CIF and then received an award for further development from the NASA Innovative Advanced Concepts program (NIAC).

Smith, Brandon↗

X-ray Micro-Tomography of Ablative Heat Shield Materials

X-ray micro-tomography is a non-destructive characterization technique that allows imaging of materials structures with voxel sizes in the micrometer range. This level of resolution makes the technique very attractive for imaging porous ablators used in hypersonic entry systems. Besides providing a high fidelity description of the material architecture, micro-tomography enables computations of bulk material properties and simulations of micro-scale phenomena. This presentation provides an overview of a collaborative effort between NASA Ames Research Center and Lawrence Berkeley National Laboratory, aimed at developing micro-tomography experiments and simulations for porous ablative materials. Measurements are carried using x-rays from the Advanced Light Source at Berkeley Lab on different classes of ablative materials used in NASA entry systems. Challenges, strengths and limitations of the technique for imaging materials such as lightweight carbon-phenolic systems and woven textiles are discussed. Computational tools developed to perform numerical simulations based on micro-tomography are described. These enable computations of material properties such as permeability, thermal and radiative conductivity, tortuosity and other parameters that are used in ablator response models. Finally, we present the design of environmental cells that enable imaging materials under simulated operational conditions, such as high temperature, mechanical loads and oxidizing atmospheres.Keywords: Micro-tomography, Porous media, Ablation

tomography↗

Recent Developments to the Porous Microstructure Analysis (PuMA) Software

The Porous Microstructure Analysis (PuMA) software is a suite of tools for the analysis of porous materials and generation of material microstructures. From microstructural data, often obtained through X-ray microtomography, PuMA can determine a number of effective material properties and perform material response simulations. Version 2.2 includes capabilities for computing volume fractions, porosity, specific surface area, effective thermal and electrical conductivities, and continuum and rarefied diffusive tortuosity. PuMA can also simulate competitive diffusion/reaction processes at the micro-scale, such as surface oxidation. In this poster, recent advancements to the PuMA software are detailed, including the full refactoring of PuMA into v3.0, a new module to compute heat conduction in anisotropic materials, a particle method for simulating molecular beam experiments, a new finite-volume Laplace solver, complex fibrous material generation, woven material generation, and a coupling of PuMA with the DAKOTA software for advanced statistics.

PuMA↗

Analysis of Fibrous Felts for Flexible Ablators Using Synchrotron Hard X-Ray Micro-Tomography

We analyzed the material properties of low-density felts that are used as substrates for new-generation flexible and conformal carbon/phenolic ablators, and compared them with those of a rigid carbon fiber preform that is used to manufacture rigid carbon/phenolic ablators. Micro-tomography measurements were obtained using synchrotron X-rays, allowing the characterization of the materials microstructure at the scale of the fibers. Using the tomography voxels as computational grids, we computed tortuosity and room temperature conductivity. In addition we performed micro-scale simulations of the oxidation of carbon fibers using a random walk model for oxygen diffusion and a probability law to model surface reactions.

Ablation↗

3D Photocatalytic Air Processor for Dramatic Reduction of Life Support Mass and Complexity

To dramatically reduce the cost and risk of CO2 management systems in future extended missions, we have conducted preliminary studies on the materials and device development for advanced "artificial photosynthesis" reaction systems termed the High Tortuosity PhotoElectroChemical (HTPEC) system. Our Phase I studies have demonstrated that HTPEC operates in much the same way a tree would function, namely directly contacting the cabin air with a photocatalyst in the presence of light and water (as humidity) to immediately conduct the process of CO2 reduction to O2 and useful, "tunable" carbon products. This eliminates many of the inefficiencies associated with current ISS CO2 management systems. We have laid the solid foundation for Phase II work to employ novel and efficient reactor geometries, lighting approaches, 3D manufacturing methods and in-house grown novel catalytic materials.The primary objective of the proposed work is to demonstrate the scientific and engineering foundation for light-activated, compact devices capable of converting CO2 to O2 and mission-relevant carbon compounds. The proposed HTPEC CO2 management system will demonstrate a novel pathway with high efficiency and reliability in a compact, lightweight reactor architecture. The proposed HTPEC air processing concept can be developed in multiple architectures, such as centralized processing as well as "artificial leaves" distributed throughout the cabin that utilize pre-existing cabin ventilation (wind). Additionally, HTPEC can be deployed with spectrally tunable collection channels for selectable product generation. HTPEC employs light as its only energy source to remove and convert waste CO2 using a non-toxic composite catalyst.We have demonstrated in the Phase I studies the production, tunability and robustness of the novel composite catalysts following the preliminary work in the Chen laboratory. Additionally, we have designed, fabricated and tested all components of HTPEC device with active materials, including flow modeling to optimize flow mixing and pressure drop as well as the production of ethylene and other larger hydrocarbons. To best determine how this technology could be implemented, we also performed system integration optimization and trade studies. This includes parameters such as mass, volume, power in relation to selected mission configurations, CO2 delivery methods and light source/delivery approaches.

Artificial Photosynthesis↗

Multi-Scale Modeling of Low-Density Carbon-Phenolic Ablators

Protecting a spacecraft during atmospheric entry is one of highest risk factors that needs to be mitigated during design of a space exploration mission. At entry speeds from space, air turns into high-temperature plasma, and spacecraft Thermal Protection Systems (TPS) are needed to protect the vehicle payload. Modern successful material architectures of spacecraft shields use a porous carbon fiber substrate impregnated with phenolic as an ablator material. In the lecture, efforts to build a Predictive Material Modeling framework for porous ablators from micro-scale to macro-scale will be presented. Several numerical methods and techniques will be summarized that use voxelized images to compute geometrical properties of the porous substrate. These computed properties include porosity, specific surface area and tortuosity that are otherwise indirectly measured through experimental techniques. Direct simulation Monte Carlo (DSMC), a particle-based method for approximating the Boltzmann equation, is used to compute the permeability coefficient of the porous substrate based on its digitized representation. The method computes the flow within the microstructure, where the size of the pores may approach the mean-free-path of the flow. Finally, a high-fidelity model implemented in PATO (Porous-material Analysis Toolbox) is discussed, and some examples of ablative material response are presented, including for the first time 3D simulations of the full tiled heat shield for the Mars Science Laboratory (MSL) capsule.

Ablators↗

A Multi-Physics Study on High-Specific Power Li-O2 Batteries for Electric Aircraft

Commercialization of lithium-air batteries faces many challenges, such as electrolyte decomposition, short cycle life, low energy and power density, etc. However, commercialization of Li-O2 batteries for aeronautics is much more challenging due to additional safety constraints on cyclability and performance (high specific power and specific energy). For this presentation, we will discuss inter-related aspects of physics-based modeling of a pack: cell and battery model calibration. In addition, we will evaluate and present optimal battery designs for high discharge current density, high discharge time, and low battery mass using simulation-based optimization.The Finite Element Model (FEM) used to simulate a Li-O2 cell is based on the work of Bevara [1]. The different aspects of the model are based on: porous electrode theory and concentrated electrolyte theory; quantum tunneling model for the resistance of conformal layer of discharge product (Li2O2) [1]; Butler-Volmer kinetics for electrochemical reaction; Fick's diffusion for oxygen transport; and an oxygen dissolution model is applied at the air/electrolyte interface [2]. The electrolyte properties such as ion conductivity, ion diffusion, oxygen diffusion, and mass density of the electrolyte were taken from Molecular Dynamics (MD) simulations [3]; while the other model parameters, which includes mass of cell components, were calibrated to match experiments at high discharge current densities. The cell mass includes the anode, cathode, separator, electrolyte, and other components (such as current collector). This calibrated model is used to perform parametric studies on cathode thickness, porosity, tortuosity, carbon particle size, electrolyte transport and material properties, partial pressure of oxygen, discharge time, and discharge current density to study optimal designs for high specific power and energy. References:1. Bevara, V. & Andrei, P. (2014), J. Electrochem. Soc. 161 (14), A2068-A2079.2.Mehta, M. & Andrei, P. (2015), J. Power Sources. 286, 299-308.3.Liyana-Arachchi, T.; Haskins, J.; Burke, C.; Diederichsen, K.; McCloskey, B.; & Lawson, J. (2018), J. Phys. Chem. B. 122 (36), 8548 - 8559.4.Choi, W.; Kikumoto, H.; Choudhary, R. & Ooka, R. (2018), Applied Energy, 209, 306-321.

Mehta, Mohit↗

Quantification of Ophthalmic Changes After Long-Duration Spaceflight, and Subsequent Recovery

A subset of crewmembers are subjected to ophthalmic structure changes due to long-duration spaceflight (>6 months). Crewmembers who experience these changes are described as having Spaceflight Associated Neuro-Ocular Syndrome (SANS). Characteristics of SANS include optic disk edema, cotton wool spots, choroidal folds, refractive error, and posterior globe flattening. SANS remains a major obstacle to deep-space and planetary missions, requiring a better understanding of its etiology. Quantification of ocular, structural changes will improve our understanding of SANS pathophysiology. Methods were developed to quantify 3D optic nerve (ON) and ON sheath (ONS) geometries, ON tortuosity, and posterior globe deformation using MR imaging.

Sater, S. H.↗

A Multiphysics Study to Improve Specific Energy of Primary Batteries for Low Temperature Operation for Deep Space Missions

Several lander missions on the outer planets such as Europa, Enceladus, and Titan require electrical power to operate scientific and communication equipment. The traditional power generation methods, such as a photovoltaic array, are not feasible as their efficiency drops significantly at these vast distances. The novel radioisotope power systems are not practical today based on current lander designs and the effectiveness of these systems. To perform in situ science on distant planets, a high specific energy battery (>700 Wh/kg) needs to operate for about 480 hours under cold temperatures (-40C or 0C) [1]. While a primary battery such as Li-CFx can provide high specific energy at room temperature, its specific capacity decreases significantly at low temperatures. One of the causes for this drop is low ion and electrical conductivity, and slower reaction kinetics. Slower transport and facile kinetics lead to an increase in the battery’s resistance and higher voltage drops during the cell operation, thus reducing specific capacity. Both the transport and kinetics show a strong dependence on temperature. Thus, a small temperature rise can lead to an increase in the reaction rate and ion conductivity; since the temperature, cell resistance, and specific capacity are interdependent. A conventional battery model accounts for ohmic, thermodynamic, and, electrochemical, and chemical decomposition heating. The ohmic heating can be controlled by designing a resistive microstructure and varying the ratios of the active materials [2]. The kinetics can be improved by increasing the surface area, reducing the particle size, or adding a catalyst. These parameters are often optimized to achieve high specific energy at room temperatures. A similar optimization study is not available at low temperatures and for a primary (high specific energy) battery. For this presentation, we will explore the effect of geometrical, microstructural, and material properties on optimal specific capacity at low temperatures through multiphysics simulations. The ion transport resistance depends on the porosity and the tortuosity of an electrode and the separator.

M. Mehta↗