Search NASA⌕ Search

SEARCH · Search NASA

Results for “total temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Tabulation of data from tests of an NPL 9510 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

The tabulated data from tests of a six inch chord NPL 9510 airfoil in the Langley 0.3-Meter Transonic Cryogenic Tunnel. The tests were performed over the following range of conditions: Mach numbers of 0.35 to 0.82, total temperature of 94 K to 300 K, total pressure of 1.20 to 5.81 atm, Reynolds number based on chord of 1.34 x 10 to the 6th to 48.23 x 10 to the 6th, and angle of attack of 0 deg to 6 deg. The NPL 9510 airfoil was observed to have decreasing drag coefficient up to the highest test Reynolds number.

Jenkins, R. V.↗

Aerothermal tests of a 12.5 percent cone at Mach 6.7 for various Reynolds numbers, angles of attack and nose shapes

The effects of free-stream unit Reynolds number, angle of attack, and nose shape on the aerothermal environment of a 3-ft basediameter, 12.5 deg half-angle cone were investigated in the Langley 8-foot high temperature tunnel at Mach 6.7. The average total temperature was 3300 R, the freestream unit Reynolds number ranged from 400,000 to 1,400,000 per foot, and the angle of attack ranged from 0 deg to 10 deg. Three nose configurations were tested on the cone: a 3-in-radius tip, a 1-in-radius tip on an ogive frustum, and a sharp tip on an ogive frustum. Surface-pressure and cold-wall heating-rate distributions were obtained for laminar, transitional temperature in the shock layer were obtained. The location of the start of transition moved forward both on windward and leeward sides with increasing free-stream Reynolds numbers, increasing angle of attack, and decreasing nose bluntness.

Nowak, R. J.↗

Soil temperature extrema recovery rates after precipitation cooling

From a one dimensional view of temperature alone variations at the Earth's surface manifest themselves in two cyclic patterns of diurnal and annual periods, due principally to the effects of diurnal and seasonal changes in solar heating as well as gains and losses of available moisture. Beside these two well known cyclic patterns, a third cycle has been identified which occurs in values of diurnal maxima and minima soil temperature extrema at 10 cm depth usually over a mesoscale period of roughly 3 to 14 days. This mesoscale period cycle starts with precipitation cooling of soil and is followed by a power curve temperature recovery. The temperature recovery clearly depends on solar heating of the soil with an increased soil moisture content from precipitation combined with evaporation cooling at soil temperatures lowered by precipitation cooling, but is quite regular and universal for vastly different geographical locations, and soil types and structures. The regularity of the power curve recovery allows a predictive model approach over the recovery period. Multivariable linear regression models alloy predictions of both the power of the temperature recovery curve as well as the total temperature recovery amplitude of the mesoscale temperature recovery, from data available one day after the temperature recovery begins.

Welker, J. E.↗

A comparison of calibration techniques for hot-wires operated in subsonic compressible slip flows

This paper focuses on the correlation of constant temperature anemometer voltages to velocity, density, and total temperature in the transonic slip flow regime. Three different calibration schemes were evaluated. The ultimate use of these hot-wire calibrations is to obtain fluctuations in the flow variables. Without the appropriate mean flow sensitivities of the heated wire, the measurements of these fluctuations cannot be accurately determined.

Jones, Gregory S.↗

Numerical Investigation of the Effect of Cooling Airflow inside High-Pressure Turbine using the Source Term Approach

In this study, the Open National Combustion code (OpenNCC) is applied to simulate the airflow inside the high-pressure turbine (HPT) of the energy efficient engine (EEE). The main objective of this study is to compare the characteristics of the HPT performance obtained by using three different approaches (Case 1: the realistic combustion products are considered at the HPT inlet, but the cooling airflows are not included, Case 2: the working fluid is assumed to be a single gas (i.e., air), and the cooling airflows are considered, Case 3: the cooling airflow and the combustion products at the HPT inlet are included). To mimic the cooling airflows at the HPT surface, we use the surface source team approach, in which we impose the source term at a specific area of a cooling airflow hole at the solid surfaces by specifying an injection angle, temperature, turbulent intensity, and mass flowrate of each cooling airflow. For the validation of the model, the data for the EEE model was obtained from the General Electric (GE) test campaign (RDG10), and the full scale warm-air rig test condition representing a test point close to the integrated core/low spool design condition was considered. This validation test was done using the stationary uniform inflow condition (i.e., the reported total temperature and total pressure). Secondly, we considered the Sea-Level Take-off (SLTO) engine condition and separately performed the combustor simulation to obtain a more realistic time-averaged, spatially-nonuniform HPT inflow condition. This work provides a better understanding the effect of the cooling airflow model with different assumptions on the HPT performance. It is found that using different working gas have a minor effect on the performance metric, however the presence of the cooling airflows significantly affects the HPT performance such as the turbine efficiency.

CFD Hot-streaks↗

Preliminary study of the minimum temperatures for valid testing in a cryogenic wind tunnel

The minimum operating temperature which avoids real-gas effects, such as condensation, was determined for M sub infinity = 0.85 flow over a 0.137-meter NACA 0012-64 airfoil mounted in the Langley 1/3-meter transonic cryogenic tunnel. For temperatures within 5 K of reservoir saturation and total pressures from 1.2 to 4.5 atmospheres, the pressure distributions over the airfoil are not altered by real-gas effects. This ability to test at total temperatures below those which avoid saturation over the airfoil allows an increase in Reynolds number capability of at least 17 percent for a constant tunnel total pressure. Similarly, 17 percent less total pressure is required to obtain a given Reynolds number.

Hall, R. M.↗

Static force tests of a sharp leading edge delta-wing model at ambient and cryogenic temperatures with a description of the apparatus employed

A sharp leading edge delta-wing model was tested through an angle-of-attack range at Mach numbers of 0.75, 0.80, and 0.85 at both ambient and cryogenic temperatures in the Langley 1/3-meter transonic cryogenic tunnel. Total pressure was varied with total temperature in order to hold test Reynolds number constant at a given Mach number. Agreement between the aerodynamic data obtained at ambient and cryogenic temperatures indicates that flows with leading-edge vortex effects are duplicated properly at cryogenic temperatures. The test results demonstrate that accurate aerodynamic data can be obtained by using conventional force-testing techniques if suitable measures are taken to minimize temperature gradients across the balance and to keep the balance at ambient (warm) temperatures during cryogenic operation of the tunnel.

Kilgore, R. A.↗

Simulation of ideal-gas flow by nitrogen and other selected gases at cryogenic temperatures

The real gas behavior of nitrogen, the gas normally used in transonic cryogenic tunnels, is reported for the following flow processes: isentropic expansion, normal shocks, boundary layers, and interactions between shock waves and boundary layers. The only difference in predicted pressure ratio between nitrogen and an ideal gas which may limit the minimum operating temperature of transonic cryogenic wind tunnels occur at total pressures approaching 9 atm and total temperatures 10 K below the corresponding saturation temperature. These pressure differences approach 1 percent for both isentropic expansions and normal shocks. Alternative cryogenic test gases were also analyzed. Differences between air and an ideal diatomic gas are similar in magnitude to those for nitrogen and should present no difficulty. However, differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. It is concluded that helium and cryogenic hydrogen would not approximate the compressible flow of an ideal diatomic gas.

Hall, R. M.↗

Discharge Coefficients for Axisymmetric Supersonic Nozzles

Computational Fluid Dynamics (CFD) analysis was used to compute effective nozzle discharge coefficients for subscale sharp-edged converging/diverging nozzles, with a variety of convergence half-angles, motor operating conditions, and two propellants with different ballistics. Convergence half-angles ranged from 0 to 80 deg. Analysis was conducted at total temperatures from 2946K (5303R) to 3346K (6023R) and over total pressures ranged from 2.72 MPa (395 psia) to 20.68 MPa (3000 psia). Area ratios (A(sub e)/A*) ranged from 7.43 to 9.39. Ratio of specific heats (gamma) ranged from 1.13 to 1.18. Throat and exit Reynolds numbers were calculated to be 8.26 x 10(exp 5) and 5.51 x 10(exp 5), respectively. Present results of nozzle discharge coefficients are reported and correlated as a function of nozzle convergence half-angle (theta(sub c)) and area ratios (A(sub e)/A*) for a constant divergence half-angle (theta(sub d)) of 15 deg. Computed discharge coefficients ranged from 0.88 to 0.97. They are compared with theory and experimental data available in literature. Available turbulence models with respect to grid refinements and heat transfer are discussed.

Ahmad, Rashid A.↗

Analysis of Unsteady Tip and Endwall Heat Transfer in a Highly Loaded Transonic Turbine Stage

In a previous study, vane-rotor shock interactions and heat transfer on the rotor blade of a highly loaded transonic turbine stage were simulated. The geometry consists of a high pressure turbine vane and downstream rotor blade. This study focuses on the physics of flow and heat transfer in the rotor tip, casing and hub regions. The simulation was performed using the Unsteady Reynolds-Averaged Navier-Stokes (URANS) code MSU-TURBO. A low Reynolds number k-epsilon model was utilized to model turbulence. The rotor blade in question has a tip gap height of 2.1 percent of the blade height. The Reynolds number of the flow is approximately 3x10(exp 6) per meter. Unsteadiness was observed at the tip surface that results in intermittent "hot spots". It is demonstrated that unsteadiness in the tip gap is governed by inviscid effects due to high speed flow and is not strongly dependent on pressure ratio across the tip gap contrary to published observations that have primarily dealt with subsonic tip flows. The high relative Mach numbers in the tip gap lead to a choking of the leakage flow that translates to a relative attenuation of losses at higher loading. The efficacy of new tip geometry is discussed to minimize heat flux at the tip while maintaining choked conditions. In addition, an explanation is provided that shows the mechanism behind the rise in stagnation temperature on the casing to values above the absolute total temperature at the inlet. It is concluded that even in steady mode, work transfer to the near tip fluid occurs due to relative shearing by the casing. This is believed to be the first such explanation of the work transfer phenomenon in the open literature. The difference in pattern between steady and time-averaged heat flux at the hub is also explained.

Shyam, Vikram↗

Scaling Evaluation of Ice-Crystal Icing on a Modern Turbofan Engine in PSL Using the COMDES-MELT Code

This paper presents preliminary ice-crystal icing (ICI) altitude scaling evaluation results of a Honeywell Uncertified Research Engine (HURE) that was tested in the NASA Glenn Research Center Propulsion Systems Laboratory (PSL) during January of 2018. This engine geometry features a hidden core design to keep the core less exposed. The engine was fitted with internal video cameras to observe various ice buildup processes at multiple selected locations within the engine core flow path covering the fan stator, the splitter-lip/shroud/strut, and the high pressure compressor (HPC) variable inlet guide vane (IGV) regions. The potential ice accretion risk was pre-determined to occur by using NASA’s in-house 1D Engine Icing Risk assessment code, COMDES-MELT. The code was successful in predicting the risk of ice accretion in adiabatic regions like the fan-stator of the HURE at specific engine operating points. However at several operating points during the test, liquid water was observed running along the shroud toward the variable IGV of the HPC regions with an air temperature well below freezing, thus no particle melting could have occurred due to heating from the air alone. It was reasoned that other sources of heat were present in that region. To account for these heat sources the inlet total temperature was adjusted to give a wet bulb temperature of 24 F below the standard minimum wet bulb temperature of 492 R to allow ice to accrete in the splitter-lip/shroud/strut region, which was determined from a reference case where hard ice was observed in that region. With that adjustment the COMDES-MELT code was successful in providing operating points where there was a risk of ice accretion during the test campaign. In addition to calculating possible conditions at different selected lower altitudes, simulations were run to determine potential inlet conditions that could lead to ice-crystal accretion along the prescribed stations where the cameras were available. From there, scaled test conditions were determined by best matching the following three icing related parameters of the reference condition: (1) the local air total wet bulb temperature, (2) the local ice crystal cloud melt ratio and (3) the engine fan face ice/water to air mass flux ratio of the ice crystal cloud. Instantaneous images taken from the time-lapsed movies of ice buildup were used along with the relevant thermodynamic data of air, water vapor and local icing condition to help evaluate how closely the proposed altitude scaling method could be used in ground based test facility to duplicate selected reference ICI features observed at specific location inside this engine at different scale altitudes. Discussions on observed limitation for engine icing scaling application from this test campaign and needed improvement are provided. A scaling test procedure to help identify potential ICI risk conditions and possible ice accretion locations of a new turbofan engine is evaluated in PSL.

Engine Testing in PSL↗

Spectroscopic research on infrared emittance of coal ash deposits

This paper deals with thermal radiation characteristics of ash deposits on a pulverized coal combustion boiler of an electric power plant. Normal emittance spectra in the near to medium infrared (2.5-25 {mu}m) region and total normal emittances were measured on four kinds of ground ash deposits. Measurements were conducted in the 570-1460 K temperature range which is common for boiler furnaces, by both heating and cooling the ash samples, with the aim to study the effect of their thermal history. Dependence of emittance on wavelength, temperature and chemical composition was studied, too. Samples were tested for transparency (opacity) to verify the accuracy of results. It was determined that the thicknesses used for the ash powders are opaque for infrared radiation for thicknesses in the order of a millimeter. Tests have shown that spectral emittance increases with an increase of wavelength with a characteristic pattern common for all samples. Spectral normal emittance increases strongly with temperature at shorter wavelengths and remains high and unchanged at longer ones. Emittance spectra are not very sensitive to chemical composition of ashes especially beyond {lambda} {approx} 5 {mu}m. With an increase of temperature, total emittance of the powdered sample decreases to a minimum value around 1200 K. Further temperature rise induces an increase of total emittance due to sintering in the ash. On cooling, the emittance increases monotonically following the hysteresis. Quantitative directions for evaluating thermal radiation characteristics of ash deposits for the merits of the safety design of boiler furnaces were proposed. That comprises correlating the experimentally obtained emittance spectra with curves of simple analytical form, i.e., a continuous function of minimum emittance vs. wavelength. The proposed method can be extended to other specimens from the same furnace and used to determine correlations for thermal calculation of old and design of new furnaces - with similar geometry and combusting similar coal. The method is potentially applicable to completely different boiler furnaces combusting different coal, and the authors recommend running the tests with new deposit samples. The data will then be applicable to the thermal design of a whole new class of furnaces, having similar geometry and combusting similar coal. This is expected to greatly enhance the accuracy and precision of thermal calculation as well as the efficiency of thermal design of steam boilers. (author)

20 FOSSIL-FUELED POWER PLANTS↗

Real-gas effects 1: Simulation of ideal gas flow by cryogenic nitrogen and other selected gases

The thermodynamic properties of nitrogen gas do not thermodynamically approximate an ideal, diatomic gas at cryogenic temperatures. Choice of a suitable equation of state to model its behavior is discussed and the equation of Beattie and Bridgeman is selected as best meeting the needs for cryogenic wind tunnel use. The real gas behavior of nitrogen gas is compared to an ideal, diatomic gas for the following flow processes: isentropic expansion; normal shocks; boundary layers; and shock wave boundary layer interactions. The only differences in predicted pressure ratio between nitrogen and an ideal gas that may limit the minimum operating temperatures of transonic cryogenic wind tunnels seem to occur at total pressures approaching 9atmospheres and total temperatures 10 K below the corresponding saturation temperature, where the differences approach 1 percent for both isentropic expansions and normal shocks. Several alternative cryogenic test gases - air, helium, and hydrogen - are also analyzed. Differences in air from an ideal, diatomic gas are similar in magnitude to those of nitrogen. Differences for helium and hydrogen are over an order of magnitude greater than those for nitrogen or air. Helium and hydrogen do not approximate the compressible flow of an ideal, diatomic gas.

Hall, R. M.↗

Ozone conservation and entrainment in cumulus congestus

This study demonstrates that ozone mixing ratio is conserved during moist convection and can be used as a tracer for cloud entrainment studies. The approach is to apply mixing line analysis to pairs of liquid water potential temperature, total water mixing ratio, O3 and pseudo-equivalent potential temperature derived from aircraft penetrations of growing cumulus congestus. Conclusions about entrainment from the mixing diagrams employing O3 agree with those using thermodynamic quantities. Any disagreement uncovered deficiencies in the water substance measurement technique.

Pearson, R., Jr.↗

Temperature and Flow Measurements in Incompressible Heated Jets

An experimental study is conducted to perform time-resolved temperature and velocity measurements on a Mach 0.08 jet at total temperatures of 295 K and 353 K. Mean and rms temperature data acquired using two fine wire sensors with diameters 1.3 and 3.8 μm are compared. In order to extend the limited frequency response of the wires, the temperature data are post-processed using a frequency compensation technique available in the literature. Corresponding velocity measurements are performed at cold and heated conditions using single and parallel wire probes. Simultaneously measured temperature and velocity data obtained using the parallel wire probe are used to calculate correlations pertinent to axial turbulent heat flux. In addition to shedding some light on the aerothermal properties of heated turbulent jets, vis-`a-vis their cold counterparts, this study also provides a database for numerical prediction of these flows.

Temperature measurement, turbulence, Jets, Turbule↗

Experimental aerodynamic heating to simulated space shuttle tiles in laminar and turbulent boundary layers with variable flow angles at a nominal Mach number of 7

The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally by using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold wall heating rate data for laminar and turbulent flow were obtained in the Langley 8 foot high Temperature Tunnel at a nominal Mach number of 7, a nominal total temperature of 3300R, a free stream unit Reynolds number from 3.4 x 10 sup 5 to 2.2 10 sup 6 per foot, and a free stream dynamic pressure from 2.1 to 9.0 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads. For the conditions of the present study, the results show that localized and total heating are sensitive to changes in flow angle only for the test conditions of turbulent boundary layer flow with high kinetic energy and that a flow angle from 30 deg to 50 deg will minimize the local heating.

Avery, D. E.↗

A two component model of the diurnal variations in the thermospheric composition

A self-consistent, two-dimensional, two-component diffusion model is presented to describe the diurnal component of thermosphere dynamics. In the regions where oxygen and helium are the minor constituents, diffusion is shown to increase the amplitudes of these constituents and to advance the times of their diurnal maxima by several hours with respect to the gas temperature and the major species. Both effects are in basic agreement with satellite observations. The diffusion process is relatively insignificant for temperature, total mass density, and wind fields. The magnitude of the temperature-density phase delay is discussed with respect to its dependence on the electron density distribution.

Mayr, H. G.↗

Experimental aerodynamic heating to simulated shuttle tiles

The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold-wall heating rate data for laminar and turbulent flow were obtained in the Langley 8-foot high temperature tunnel at a nominal Mach number of 7, a nominal total temperature of 3300 R, free-stream unit Reynolds number from 3.4 x 10 to the 5th power to 2.2 x 10 to the 6th power per foot, and free-stream dynamic pressure of 1.8 psia to 9.1 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads.

Avery, D. E.↗