Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Improved sample utilization in thermal ionization mass spectrometry isotope ratio measurements: refined development of porous ion emitters for nuclear forensic applications

The precise and accurate determination of isotopic composition in nuclear forensic samples is vital for assessing origin, intended use and process history. Thermal ionization mass spectrometry (TIMS) is widely accepted as the gold standard for high performance isotopic measurements and has long served as the workhorse in the isotopic ratio determination of nuclear materials. Nuclear forensic and safeguard specialists have relied heavily on such methods for both routine and atypical e orts. Despite widespread use, TIMS methods for the assay of actinide systems continue to be hindered by poor ionization e ciency, often less than tenths of a percent; the majority of a sample is not measured. This represents a growing challenge in addressing nextgeneration nuclear detection needs by limiting the ability to analyze ultratrace quantities of high priority elements that could potentially provide critical nuclear forensic signatures. Porous ion emitter (PIE) thermal ion sources were developed in response to the growing need for new TIMS ion source strategies for improved ionization e ciency, PIEs have proven to be simple to implement, straightforward approach to boosting ion yield. This work serves to expand the use of PIE techniques for the analysis of trace quantities of plutonium and americium. PIEs exhibited superior plutonium and americium ion yields when compared to direct lament loading and the resin bead technique, one of the most e cient methods for actinide analysis, at similar mass loading levels. Initial attempts at altering PIE composition for the analysis of plutonium proved to enhance sample utilization even further. Preliminary investigations of the instrumental fractionation behavior of plutonium and uranium analyzed via PIE methods were conducted. Data collected during these initial trial indicate that PIEs fractionate in a consistent, reproducible manner; a necessity for high precision isotope ratio measurements. Ultimately, PIEs methods were applied for the age determination of various uranium isotopic standards. PIEs did not exhibit signi cant advantages for the determination of model ages when compared to traditional laments; however, this trial was able to provide valuable insight for guiding future investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating Solvent Purity Utilizing Comprehensive Gas Chromatography: A Study of Acetones

Broad spectrum chemical analysis of trace level components is a continuing challenge for any analytical chemist. This challenge is further confounded when chemical impurities may be present in common organic solvents or when chemical artifacts may be formed, produced and introduced during an analytical procedure. Minimizing and understanding these chemical artifacts, is critical for trace level detection and is crucial for unambiguous analytical results. Comprehensive gas chromatography is an excellent analytical tool to help address these complex mixture challenges. This work examines the impurities present in various acetone sources utilizing comprehensive gas chromatography. This work highlights the extreme variability possible in solvent sources and hence the importance of understanding the impurities that may confound an analytical method or result.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials

Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dissolution of aerosol particles collected from nuclear facility plutonium production process

Here, a simple, robust analytical chemistry method has been developed to dissolve plutonium containing particles in a complex matrix. The aerosol particles collected on Marple cascade impactor substrates were shown to be dissolved completely with an acid mixture of 12 M HNO 3 and 0.1 M HF. A pressurized closed vessel acid digestion technique was utilized to heat the samples at 130 °C for 16 h to facilitate the digestion. The dissolution efficiency for plutonium particles was 99 %. The resulting particle digestate solution was suitable for trace elemental analysis and isotope composition determination, as well as radiochemistry measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Determination of origin and intended use of plutonium metal using nuclear forensic techniques

Nuclear forensics techniques, including micro-XRF, gamma spectrometry, trace elemental analysis and isotopic/chronometric characterization were used to interrogate two, potentially related plutonium metal foils. These samples were submitted for analysis with only limited production information, and a comprehensive suite of forensic analyses were performed. Resulting analytical data was paired with available reactor model and historical information to provide insight into the materials’ properties, origins, and likely intended uses. Both were super-grade plutonium, containing less than 3% 240 Pu, and age-dating suggested that most recent chemical purification occurred in 1948 and 1955 for the respective metals. Additional consideration of reactor modelling feedback and trace elemental observables indicate plausible U.S. reactor origin associated with the Hanford site production efforts. In conclusion, based on this investigation, the most likely intended use for these plutonium foils was 239 Pu fission foil targets for physics experiments, such as cross-section measurements, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electrochemical Sensors Based on Nanomaterials for Environmental Monitoring

This article review work relevant to the two fastest growing nanomaterials in electrochemical sensing of metal ions: organically modified ordered mesoporous silicas (OMSs) and carbon nanotubes (CNTs). Nanostructured self-assembled monolayers on mesoporous silicas (SAMMS) materials are highly effective as electrode modifiers; they can be either mixed with conductive materials or spin-cast as a thin-film on electrode surface. The interfacial chemistry of SAMMS can be fine-tuned to selectively preconcentrate the specific metal ions of interest. The functional groups on SAMMS materials enable the preconcentration to be done without mercury, supporting electrolytes, applied potential, and solution degassing, all of which are often required in conventional adsorptive stripping voltammetric sensors. Since it was first introduced in 1991, CNTs have been widely investigated for electrochemical sensors of many important biomolecules because of their electrocatalytic and antifouling properties, biocompatibility, high surface, and mechanical strength. For trace metal analysis, CNT thin-film created by drop-coating of CNT-solvent suspensions on electrode surfaces has been explored in order to develop mercury-free sensors by exploiting the bulk properties of the CNTs. Array of low-site-density aligned carbon nanotubes has been grown on metal substrates by a non-lithographic method. Each CNT serves as a nanoelectrode which normally has greater mass transfer rate and higher mass sensitivity than conventional macroelectrodes. The array of millions of CNT nanoelectrodes provides magnified voltammetric signals for trace metal ions without the need for a signal amplifier.

Electrochemical Sensors↗

Purification of Cu by hydrogen plasma-arc zone melting and characterization of trace impurities by secondary ion mass spectrometry

Purification of 4N (99.99%) and 6N (99.9999%) purity Cu rods by hydrogen plasma-arc zone melting was carried out. Weight loss in the 4N and 6N Cu rods as a function of number of zone refined passes revealed a higher rate of impurity removal by vaporization in 4N Cu when compared to 6N Cu. Purification effect was studied by analyzing major impurities like Mg, Si, Ca, Ti, Cr, Ni and Fe by O{sub 2}{sup +} ions and C, O, As, Cl, P and S by Cs{sup +} ion sources using secondary ion mass spectrometry. A remarkable decrease of Si, Ti and Fe impurity concentrations in Cu at x/L = 0.03 after 10 zone passes was observed, but no similar purification effect along the remaining length of the zone refined copper rod was observed. Mg, Se and Ca in the Cu rods were reduced faster by a high evaporation effect due to P{sub i}/P{sub Cu} > 10{sup 2}. On the other hand, removal of O, C, S and Se was expectedly dominated by vaporization in the form of H{sub 2}O, CH{sub 4,} H{sub 2}S, and H{sub 2}Se through thermodynamically favored reactions. The overall segregation rate of the individual impurity elements was decreased with an increase in the purity from 4N to 6N of Cu rods. SIMS analysis of trace impurities was successfully carried out on HPZM Cu for quantitative estimation.

36 MATERIALS SCIENCE↗

Sandia Optical Fringe Analysis Slope Tool (SOFAST) v. 2018.11.20

SOFAST is used to characterize the surface slope of reflective mirrors for solar applications. SOFAST uses a large monitor or projection screen to display fringe patterns, and a machine vision camera to image the reflection of these patterns in the subject mirror. From these images, a detailed map of surface normals can be generated and compared to design or fitted mirror shapes. SOFAST uses standard Fringe Reflection (Deflectometry) approaches to measure the mirror surface normals. SOFAST uses an extrinsic analysis of key points on the facet to locate the camera and monitor relative to the facet coordinate system. It then refines this position based on the measured surface slope and integrated shape of the mirror facet. The facet is placed into a reference frame such that key points on the facet match the design facet in orientation and position. This is key to evaluating a facet as suitable for a specific solar application. SOFAST reports the measurements of the facet as detailed surface normal location in a format suitable for ray tracing optical analysis codes. SOFAST also reports summary information as to the facet fitted shape (monomial) and error parameters. Useful plots of the error distribution are also presented.

Yellowhair, Julius↗

SOFAST: Sandia Optical Fringe Analysis Slope Tool

SOFAST is used to characterize the surface slope of reflective mirrors for solar applications. SOFAST uses a large monitor or projections screen to display fringe patterns, and a machine vision camera to image the reflection of these patterns in the subject mirror. From these images, a detailed map of surface normals can be generated and compared to design or fitted mirror shapes. SOFAST uses standard Fringe Reflection (Deflectometry) approaches to measure the mirror surface normals. SOFAST uses an extrinsic analysis of key points on the facet to locate the camera and monitor relative to the facet coordinate system. It then refines this position based on the measured surface slope and integrated shape of the mirror facet. The facet is placed into a reference frame such that key points on the facet match the design facet in orientation and position. This is key to evaluating a facet as suitable for a specific solar application. SOFAST reports the measurements of the facet as detailed surface normal location in a format suitable for ray tracing optical analysis codes. SOFAST also reports summary information as to the facet fitted shape (monomial) and error parameters. Useful plots of the error distribution are also presented.

Andraka, Charles E.↗

Results of the International Energy Agency Round Robin on Fast Pyrolysis Bio-oil Production

An international round robin study of the production of fast pyrolysis bio-oil was undertaken. Fifteen institutions in six countries contributed. Three biomass samples were distributed to the laboratories for processing in fast pyrolysis reactors. Samples of the bio-oil produced were transported to a central analytical laboratory for analysis. The round robin was focused on validating the pyrolysis community understanding of production of fast pyrolysis bio-oil by providing a common feedstock for bio-oil preparation. The round robin included: •distribution of 3 feedstock samples from a common source to each participating laboratory; •preparation of fast pyrolysis bio-oil in each laboratory with the 3 feedstocks provided; •return of the 3 bio-oil products (minimum 500 ml) with operational description to a central analytical laboratory for bio-oil property determination. The analyses of interest were: density, viscosity, dissolved water, filterable solids, CHN, S, trace element analysis, ash, total acid number, pyrolytic lignin, and accelerated aging of bio-oil. In addition, an effort was made to compare the bio-oil components to the products of analytical pyrolysis through GC/MS analysis. The results showed that clear differences can occur in fast pyrolysis bio-oil properties by applying different reactor technologies or configurations. The comparison to analytical pyrolysis method suggested that Py-GC/MS could serve as a rapid screening method for bio-oil composition when produced in fluid-bed reactors. Furthermore, hot vapor filtration generally resulted in the most favorable bio-oil product, with respect to water, solids, viscosity, and total acid number. These results can be helpful in understanding the variation in bio-oil production methods and their effects on bio-oil product composition.

09 BIOMASS FUELS↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Determination of elemental constituents in different matrix materials and flow injection studies by the electrolyte cathode glow discharge technique with a new design

An open-to-air type electrolyte cathode discharge (ELCAD) has been developed with a new design. The present configuration leads to a stable plasma even at low flow rates (0.96 mL/min). Plasma fluctuations arising from the variations in the gap between solid anode and liquid cathode were eliminated by providing a V-groove to the liquid glass-capillary. Cathode (ground) connection is given to the solution at the V-groove itself. Interfaced to atomic emission spectrometry (AES), its analytical performance is evaluated. The optimized molarity of the solution is 0.2 M. The analytical response curves for Ca, Cu, Cd, Pb, Hg, Fe, and Zn demonstrated good linearity. The limit of detections of Ca, Cu, Cd, Pb, Hg, Fe, and Zn are determined to be 17, 11, 5, 45, 15, 28, and 3 ng mL{sup -1}. At an integration time of 0.3 s, the relative standard deviation (RSD) values of the acid blank solutions are found to be less than 10% for the elements Ca, Cu, Cd, Hg, Fe, and Zn and 18% for Pb. The method is applied for the determination of the elemental constituents in different matrix materials such as tuna fish (IAEA-350), oyster tissue (NIST SRM 1566a), and coal fly ash (CFA SRM 1633b). The obtained results are in good agreement with the certified values. The accuracy is found to be between 7% and 0.6% for major to trace levels of constituent elements and the precision between 11% and 0.6%. For the injection of 100 {mu} L of 200 ng mL{sup -1} mercury solution at the flow rate of 0.8 mL/min, the flow injection studies resulted in the relative standard deviation (RSD) of 8%, concentration detection limit of 10 ng/mL, and mass detection limit of 1 ng for mercury.

01 COAL, LIGNITE, AND PEAT↗

Utica Shale Energy and Environment Laboratory Final Scientific/Technical Report

The Ohio State University (OSU) was awarded a contract on October 1, 2014, from the Department of Energy National Energy Technology Laboratory (DOE-NETL) to develop the Utica Shale Energy and Environment Laboratory (USEEL) in the Utica-Point Pleasant shale play of the Appalachian Basin. It was designed to be an environmental and technology development lab that would enable the academic, industry, government, and non-governmental organization (NGO) research communities to better understand unconventional oil and gas (UOG) engineering practices and technology to increase production and safety, and decrease environmental effects. Political and economic consequences necessitated changes in project site location and design, from the Ohio State Eastern Agricultural Research Station (EARS) and the Muskingum Watershed Conservancy District (MWCD) in east-central Ohio to a site located at an Energy Corporation of America (ECA) Marcellus drill pad in Greene County, Pennsylvania. Although the overall project progressed little beyond planning and administration before termination on September 18, 2017, significant research and MS or PhD investigations were completed or continue today. An experimental study design for site specific and regional baseline assessments was developed utilizing ecoregions, United States Geological Survey (USGS) Hydraulic Unit Code watersheds, and GIS technology and databases. This can be utilized to build a defensible and scalable management and research framework for UOG investigations that can be extrapolated for predictive and comparative analyses. The most commonly mentioned perceived risks of shale energy development identified in a socioeconomic analysis included impacts to the environment and water resources, traffic and road deterioration, and crime. Economic benefits, such as the windfall wealth to residents, job opportunities, and the demand for hotels and restaurants emerged, as the main positive impact to the community. Preliminary results of an analysis of the location and mechanisms for extremely high pore pressures of the deep Utica-Point Pleasant formations of southwestern Pennsylvania and their possible relationship to high initial production rates indicate that the overpressure is caused by a combination disequilibrium compaction and fluid expansion. Drilling fluids research designed a proof-of-concept device to evaluate desalination and solvent separation in hydraulic fracturing flowback water that could facilitate water recycling and potentially mitigate deep-well injection. A groundwater study was devised to characterize the subsurface aquifers in terms of the geological framework and groundwater chemistry, including the chemistry of dissolved gases and salts. Brines and gases associated with hydrocarbon migration in groundwater (including noble gases and hydrocarbons) were to be specifically fingerprinted for use as tracers of fluid migration. Trace element analysis of fish otoliths, using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), is being utilized to assess surface water quality. This methodology will be used to reconstruct the exposure histories of fish from watersheds and discriminate between the signatures associated with hydraulic fracturing and coal mining activities.

03 NATURAL GAS↗

Nanoscale Mass Spectrometry Multimodal Imaging via Tip-Enhanced Photothermal Desorption

Materials ranging from adhesives, pharmaceuticals, lubricants, and personal care products are traditionally studied using macroscopic characterization techniques. However, their functionality is in reality defined by details of chemical organization on often noncrystalline matter with characteristic length scales on the order of microns to nanometers. Additionally, these materials are traditionally difficult to analyze using standard vacuum-based approaches that provide nanoscale chemical characterization due to their volatile and beam-sensitive nature. Therefore, approaches that operate under ambient conditions need to be developed that allow probing of nanoscale chemical phenomena and correlated functionality. Here, we demonstrate a tool for probing and visualizing local chemical environments and correlating them to material structure and functionality using advanced multimodal chemical imaging on a combined atomic force microscopy (AFM) and mass spectrometry (MS) system using tip-enhanced photothermal desorption with atmospheric pressure chemical ionization (APCI). We demonstrate enhanced performance metrics of the technique for correlated imaging and point sampling and illustrate the applicability for the analysis of trace chemicals on a human hair, additives in adhesives on paper, and pharmaceuticals samples notoriously difficult to analyze in a vacuum environment. Overall, this approach of correlating local chemical environments to structure and functionality is key to advancing research in many fields ranging from biology, to medicine, to material science.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗