Search NASA⌕ Search

SEARCH · Search NASA

Results for “traceable calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Low Level and Transuranic Waste Segregation and Low Level Waste Characterization at the 200 Area of the Hanford Site - 12424

This paper describes the waste measurement and waste characterization activities carried out by ANTECH Corporation (ANTECH) and CH2M Hill Plateau Remediation Company (CHPRC) at the 200 Area of the Hanford Site under Contracts No. 22394 and No. 40245 for the US Department of Energy (DOE). These include Low Level Waste (LLW) and Transuranic (TRU) Waste segregation and LLW characterization for both 55-gallon (200-litre) drums with gross weight up to 454 kg and 85-gallon over-pack drums. In order to achieve efficient and effective waste drum segregation and assay, ANTECH deployed an automated Gamma Mobile Assay Laboratory (G-MAL) at the trench face in both 200 Area West and East. The unit consists of a modified 40 foot ISO shipping container with an automatic flow through roller conveyor system with internal drum weigh scale, four measurement and drum rotation positions, and four high efficiency high purity Germanium (HPGe) detectors with both detector and shadow shields. The unit performs multiple far-field measurements and is able to segregate drums at levels well below 100 nCi/g. The system is sufficiently sensitive that drums, which are classified as LLW, are characterized at measurement levels that meet the Environmental Restoration Disposal Facility (ERDF) Waste Acceptance Criteria (WAC). With measurement times of between 20 and 30 minutes the unit can classify and characterize over 40 drums in an 8-hour shift. The system is well characterized with documented calibrations, lower limits of detection (LLD) and total measurement uncertainty. The calibrations are confirmed and verified using nationally traceable standards in keeping with the CHPRC measurement requirements. The performance of the system has been confirmed and validated throughout the measurement process by independent CHPRC personnel using traceable standards. All of the measurement and maintenance work has been conducted during the period under a Quality Assurance Plan (QAP) compliant with the applicable criteria of NQA-1 (2000). This includes not only the calibrations and measurements but also the data analysis activities of the ANTECH Subject Matter Experts (SME) and ANTECH support and maintenance activities as well as the activities of CHPRC staff who recover, transport and load waste drums and disposition measured and characterized drums. The overall processes of drum recovery and analysis are described in the paper. Specific spectral data is presented which illustrates the segregation, sentencing and assay process for different types of drums with different radionuclide profiles. The process of identifying and quantifying a wide range of non-TRU radionuclide isotopes is explained and illustrated with spectral examples. The difficulties associated with the measurement of drums with a high gamma ray background, usually arising from high levels of Cs-137 are considered. These drums, which would normally be declared indeterminate and treated as TRU, are addressed under contract No. 40245 by the deployment of the ANTECH Neutron Mobile Assay Laboratory. This is an Active-Passive neutron assay system housed in a modified ISO shipping container. The unit is designed for the measurement and assay of both drums and crates (including B-25 boxes and SWB containers) and will quantify the content of both plutonium and uranium. The neutron system has been employed to perform further evaluation on indeterminate drums to classify them to either LLW or TRU. The experiences of both gamma ray and neutron system operation in different conditions are described; as are the issues of throughput, drum handling and system maintenance. All of these are considered in the overriding context of safe drum handling and safe assay system operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mercury CEM Calibration

Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The outputs of mercury generators are compared to one another using a nesting procedure which allows direct comparison of one generator with another and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define generator performance as affected by variables such as pressure, temperature, line voltage, and shipping. WRI is focusing efforts to determine actual generator performance related to the variables defined in the qualification portion of the interim protocol. The protocol will then be further revised by EPA based on what can actually be achieved with the generators. Another focus of the study is to evaluate approaches for field verification of generator performance. Upcoming work includes evaluation of oxidized mercury calibration generators, for which a separate protocol will be prepared by EPA. In addition, the variability of the spectrometers/analyzers under various environmental conditions needs to be defined and understood better. A main objective of the current work is to provide data on the performance and capabilities of elemental mercury generator/calibration systems for the development of realistic NIST traceability protocols for mercury vapor standards for continuous emission CEM calibration. This work is providing a direct contribution to the enablement of continuous emissions monitoring at coal-fired power plants in conformance with the CAMR. EPA Specification 12 states that mercury CEMs must be calibrated with NIST-traceable standards (Federal Register 2005). The initial draft of an elemental mercury generator traceability protocol was circulated by EPA in May 2007 for comment, and an interim protocol was issued in August 2007 (EPA 2007). Initially it was assumed that the calibration and implementation of mercury CEMs would be relatively simple, and implementation would follow the implementation of the Clean Air Interstate Rule (CAIR) SO{sub 2} and NO{sub x} monitoring, and sulfur emissions cap and trade. However, mercury has proven to be significantly more difficult to accurately determine than was originally thought. The purpose of the current phase of this project is to evaluate issues related to the use of dynamic elemental mercury calibrators that are based on mercury vapor headspace above elemental mercury at a particular temperature.

01 COAL, LIGNITE, AND PEAT↗

Informal Preliminary Report on Comparisons of Prototype SPN-1 Radiometer to PARSL Measurements

The prototype SPN-1 has been taking measurements for several months collocated with our PNNL Atmospheric Remote Sensing Laboratory (PARSL) solar tracker mounted instruments at the Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, USA. The PARSL radiometers used in the following comparisons consist of an Eppley Normal Incident Pyrheliometer (NIP) and a shaded Eppley model 8-48 “Black and White” pyrgeometer (B&W) to measure the direct and diffuse shortwave irradiance (SW), respectively. These instruments were calibrated in mid-September by comparison to an absolute cavity radiometer directly traceable to the world standard group in Davos, Switzerland. The NIP calibration was determined by direct comparison, while the B&W was calibrated using the shade/unshade technique. All PARSL data prior to mid-September have been reprocessed using the new calibration factors. The PARSL data are logged as 1-minute averages from 1-second samples. Data used in this report span the time period from June 22 through December 1, 2006. All data have been processed through the QCRad code (Long and Shi, 2006), which itself is a more elaborately developed methodology along the lines of that applied by the Baseline Surface Radiation Network (BSRN) Archive (Long and Dutton, 2004), for quality control. The SPN-1 data are the standard total and diffuse SW values obtained from the analog data port of the instrument. The comparisons use only times when both the PARSL and SPN-1 data passed all QC testing. The data were further processed and analyzed by application of the SW Flux Analysis methodology (Long and Ackerman, 2000; Long and Gaustad, 2004, Long et al., 2006) to detect periods of clear skies, calculate continuous estimates of clear-sky SW irradiance and the effect of clouds on the downwelling SW, and estimate fractional sky cover.

Long, Charles N.↗

Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

60 APPLIED LIFE SCIENCES↗

RCT: Module 2.08, Radiological Source Control, Course 8774

radioactive source is material used for its emitted radiation. Sources are sealed or unsealed and are classified as accountable or exempt. Radioactive sources are used for response checks, functional checks, and the calibration of instruments and monitors to traceable standards. To ensure the safety and welfare of all personnel, it is important to maintain control of radioactive sources to minimize the potential for the spread of contamination, unnecessary exposure to personnel, loss or theft, and improper disposal. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Calibration and Data Retrieval Algorithms for the NASA Langley/Ames Diode Laser Hygrometer for the NASA Trace-P Mission

This paper describes the procedures and algorithms for the laboratory calibration and the field data retrieval of the NASA Langley / Ames Diode Laser Hygrometer as implemented during the NASA Trace-P mission during February to April 2000. The calibration is based on a NIST traceable dewpoint hygrometer using relatively high humidity and short pathlength. Two water lines of widely different strengths are used to increase the dynamic range of the instrument in the course of a flight. The laboratory results are incorporated into a numerical model of the second harmonic spectrum for each of the two spectral window regions using spectroscopic parameters from the HITRAN database and other sources, allowing water vapor retrieval at upper tropospheric and lower stratospheric temperatures and humidity levels. The data retrieval algorithm is simple, numerically stable, and accurate. A comparison with other water vapor instruments on board the NASA DC-8 and ER-2 aircraft is presented.

Podolske, James R.↗

A Novel Nonintrusive Method to Resolve the Thermal Dome Effect of Pyranometers: Radiometric Calibration and Implications

Traditionally the calibration equation for pyranometers assumes that the measured solar irradiance is solely proportional to the thermopile s output voltage; therefore, only a single calibration factor is derived. This causes additional measurement uncertainties because it does not capture sufficient information to correctly account for a pyranometer s thermal effect. In our updated calibration equation, temperatures from the pyranometer's dome and case are incorporated to describe the instrument's thermal behavior, and a new set of calibration constants are determined, thereby reducing measurement uncertainties. In this paper, we demonstrate why a pyranometer's uncertainty using the traditional calibration equation is always larger than a few percent, but with the new approach can become much less than 1% after the thermal issue is resolved. The highlighted calibration results are based on NIST traceable light sources under controlled laboratory conditions. The significance of the new approach lends itself to not only avoiding the uncertainty caused by a pyranometer's thermal effect but also the opportunity to better isolate and characterize other instrumental artifacts, such as angular response and nonlinearity of the thermopile, to further reduce additional uncertainties. We also discuss some of the implications, including an example of how the thermal issue can potentially impact climate studies by evaluating aerosol s direct radiative effect using field measurements with and without considering the pyranometer s thermal effect. The results of radiative transfer model simulation show that a pyranometer s thermal effect on solar irradiance measurements at the surface can be translated into a significant alteration of the calculated distribution of solar energy inside the column atmosphere.

Ji. Q.↗

Evaluation of vicarious calibration for airborne sensors using RadCalNet

Vicarious calibration approaches using in-situ measurements are key techniques applied to on-orbit remote sensors. The in-situ measurements have advantages in terms of traceability and quantifiable accuracy that make them ideal for inter-consistency studies of on-orbit sensors. The Committee on Earth Observation Satellites Working Group on Calibration and Validation Infrared Visible Optical Sensors initiated the Radiometric Calibration Network (RadCalNet) to provide automated surface and top-of-atmosphere (TOA) reflectance data from multiple participating ground sites to the worldwide user community. RadCalNet standardizes protocols for collecting data, processes TOA reflectance, and provides International System of Units traceable uncertainty budgets for the five currently operating sites. RadCalNet data from the Railroad Valley Playa, Nevada, site was used to provide an SI-traceable, absolute radiometric calibration of the Enhanced MODIS Airborne Simulator as part of an overflight of opportunity during the FIREX-AQ campaign. The results shown here demonstrate the utility of RadCalNet data for absolute radiometric calibration of airborne imagers making flights of opportunity without the need for coordination with a field validation team.

Sensors↗

MODIS On-Orbit Thermal Emissive Bands Lifetime Performance

MODerate resolution Imaging Spectroradiometer (MODIS), a leading heritage sensor in the fleet of Earth Observing System for the National Aeronautics and Space Administration (NASA) is in space orbit on two spacecrafts. They are the Terra (T) and Aqua (A) platforms. Both instruments have successfully continued to operate beyond the 6 year design life time, with the T-MODIS currently functional beyond 15 years and the A-MODIS operating beyond 13 years respectively. The MODIS sensor characteristics include a spectral coverage from 0.41 micron 14.4 micron, of which wavelengths ranging from 3.7 micron 14. 4 micron cover the thermal infrared region also referred to as the Thermal Emissive Bands (TEBs). The TEBs is calibrated using a v-grooved BlackBody (BB) whose temperature measurements are traceable to the National Institute of Standards and Technology temperature scales. The TEBs calibration based on the onboard BB is extremely important for its high radiometric fidelity. In this paper, we provide a complete characterization of the lifetime instrument performance of both MODIS instruments in terms of the sensor gain, the Noise Equivalent difference Temperature, key instrument telemetry such as the BB lifetime trends, the instrument temperature trends, the Cold Focal Plane telemetry and finally, the total assessed calibration uncertainty of the TEBs.

Madhavan, Sriharsha↗

A Comprehensive Plan for the Long-Term Calibration and Validation of Oceanic Biogeochemical Satellite Data

The primary objective of this planning document is to establish a long-term capability and validating oceanic biogeochemical satellite data. It is a pragmatic solution to a practical problem based primarily o the lessons learned from prior satellite missions. All of the plan's elements are seen to be interdependent, so a horizontal organizational scheme is anticipated wherein the overall leadership comes from the NASA Ocean Biology and Biogeochemistry (OBB) Program Manager and the entire enterprise is split into two components of equal sature: calibration and validation plus satellite data processing. The detailed elements of the activity are based on the basic tasks of the two main components plus the current objectives of the Carbon Cycle and Ecosystems Roadmap. The former is distinguished by an internal core set of responsibilities and the latter is facilitated through an external connecting-core ring of competed or contracted activities. The core elements for the calibration and validation component include a) publish protocols and performance metrics; b) verify uncertainty budgets; c) manage the development and evaluation of instrumentation; and d) coordinate international partnerships. The core elements for the satellite data processing component are e) process and reprocess multisensor data; f) acquire, distribute, and archive data products; and g) implement new data products. Both components have shared responsibilities for initializing and temporally monitoring satellite calibration. Connecting-core elements include (but are not restricted to) atmospheric correction and characterization, standards and traceability, instrument and analysis round robins, field campaigns and vicarious calibration sites, in situ database, bio-optical algorithm (and product) validation, satellite characterization and vicarious calibration, and image processing software. The plan also includes an accountability process, creating a Calibration and Validation Team (to help manage the activity), and a discussion of issues associated with the plan's scientific focus.

Hooker, Stanford B.↗

Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes

Purpose: Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have been developed to calibrate the scaling accuracy of micro-CT scanners to a traceable standard and provide corrections to image voxel sizing. Methods: The calibration phantom contains six borosilicate beads whose separations have been measured to a traceable standard. An image processing algorithm compares the known separations of the beads to their separations in micro-CT images. A least-squares solution is used to determine linear scaling correction factors along each of the three scanner axes to minimize errors in the bead separations within the images by correcting the image voxel size. The correction factors were applied to images of a similar phantom with beads at different positions to evaluate the ability of the correction factors to reduce errors at points independent of the fiducial locations in the calibration phantom. The calibration phantom was used to evaluate the scaling accuracy of five different micro-CT scanners representing four different scanner models. Results: In two of the five scanners evaluated, the correction factors significantly reduced the mean error in bead separations in the images from 0.17% to 0.05% and from 0.37% to 0.07% of the actual bead separations, respectively. Scanners yielding similar voxel sizes possessed comparable geometric errors after correction using the phantom. Conclusions: Although the magnitude of the corrections is small, such corrections can be important for demanding micro-CT applications. Even if no voxel size correction is required, the phantom provides an easily implemented method to verify the geometric fidelity of micro-CT scanners to a traceable standard of measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA s Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial and moderate resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists are also using the SSC V&V site to characterize thermal infrared systems and active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA#s Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists have used the SSC V&V site to characterize thermal infrared systems. Enhancements are being considered to characterize active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. Similar techniques are used to characterize moderate spatial resolution sensing systems at selected nearby locations. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

Sci—Fri AM: Mountain — 03: Current status of the NRC primary standard for {sup 192}Ir HDR brachytherapy sources

The Canadian primary standard for {sup 192}Ir HDR brachytherapy sources has been recently revised in a more accurate manner allowing for more realistic uncertainty estimation. Air-kerma strength S{sub k} is derived from measurements of the source's output using a graphite-walled spherical ionization chamber (2S) at several distances. Traceability to NRC primary standards for the {sup 192}Ir calibration coefficient N{sub k} is insured by estimating it as the inverse arithmetic mean of the inverse of the calibration coefficients for a {sup 137}Cs beam and the medium energy x-ray beam quality N250, both of which are traceable to NRC primary standards. The multiple-distance method is combined with a non-linear least squares fit to determine St, while at the same time removing the effects of room scatter and position offset. The previously used shadow-cone method for directly measuring the room scatter is found to be inadequate due to the increased scatter contribution from the lead cone itself, especially at short source-detector distances. Rather than including the reported 1% difference in source strength for {sup 192}Ir HDR sources of different construction into the total uncertainty, users are cautioned that the calibration coefficient provided by NRC is only valid for a microSelectron V2 model. A comprehensive uncertainty budged shows that the total one sigma uncertainty of the standard is actually 0.6% rather than the previously assumed 1.2%. NRC measured S{sub k} agrees within 0.03% of the manufacturer's value.

07 ISOTOPE AND RADIATION SOURCES↗

Climate Benchmark Missions: CLARREO

CLARREO (Climate Absolute Radiance and Refractivity Observatory) is one of the four Tier 1 missions recommended by the recent NRC decadal survey report on Earth Science and Applications from Space (NRC, 2007). The CLARREO mission addresses the need to rigorously observe climate change on decade time scales and to use decadal change observations as the most critical method to determine the accuracy of climate change projections such as those used in the Fourth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC AR4). A rigorously known accuracy of both decadal change observations as well as climate projections is critical in order to enable sound policy decisions. The CLARREO mission accomplishes this critical objective through highly accurate and SI traceable decadal change observations sensitive to many of the key uncertainties in climate radiative forcings, responses, and feedbacks that in turn drive uncertainty in current climate model projections. The same uncertainties also lead to uncertainty in attribution of climate change to anthropogenic forcing. The CLARREO breakthrough in decadal climate change observations is to achieve the required levels of accuracy and traceability to SI standards for a set of observations sensitive to a wide range of key decadal change variables. These accuracy levels are determined both by the projected decadal changes as well as by the background natural variability that such signals must be detected against. The accuracy for decadal change traceability to SI standards includes uncertainties of calibration, sampling, and analysis methods. Unlike most other missions, all of the CLARREO requirements are judged not by instantaneous accuracy, but instead by accuracy in large time/space scale average decadal changes. Given the focus on decadal climate change, the NRC Decadal Survey concluded that the single most critical issue for decadal change observations was their lack of accuracy and low confidence in observing the small but critical climate change signals. CLARREO is the recommended attack on this challenge, and builds on the last decade of climate observation advances in the Earth Observing System as well as metrological advances at NIST (National Institute of Standards and Technology) and other standards laboratories.

Wielicki, Bruce A.↗

A Novel Non-Intrusive Method to Resolve the Thermal-Dome-Effect of Pyranometers: Radiometric Calibration and Implications

Traditionally the calibration equation for pyranometers assumes that the measured solar irradiance is solely proportional to the thermopile's output voltage; therefore only a single calibration factor is derived. This causes additional measurement uncertainties because it does not capture sufficient information to correctly account for a pyranometer's thermal effect. In our updated calibration equation, temperatures from the pyranometer's dome and case are incorporated to describe the instrument's thermal behavior, and a new set of calibration constants are determined, thereby reducing measurement uncertainties. In this paper, we demonstrate why a pyranometer's uncertainty using the traditional calibration equation is always larger than a-few-percent, but with the new approach can become much less than 1% after the thermal issue is resolved. The highlighted calibration results are based on NIST-traceable light sources under controlled laboratory conditions. The significance of the new approach lends itself to not only avoiding the uncertainty caused by a pyranometer's thermal effect but also the opportunity to better isolate and characterize other instrumental artifacts, such as angular response and non-linearity of the thermopile, to further reduce additional uncertainties. We also discuss some of the implications, including an example of how the thermal issue can potentially impact climate studies by evaluating aerosol's direct-radiative effect using field measurements with and without considering the pyranometer's thermal effect. The results of radiative transfer model simulation show that a pyranometer's thermal effect on solar irradiance measurements at the surface can be translated into a significant alteration of the calculated distribution of solar energy inside the column atmosphere.

Ji, Qiang↗

Absolute Calibration Accuracy for Hyperspectral Imagers in the Solar Reflective

The characterization and calibration of hyperspectral imagers is a challenging one that is expected to become even more challenging as needs increase for highly-accurate radiometric data from such systems. The preflight calibration of the Advanced Responsive Tactically Effective Military Imaging Spectrometer (ARTEMIS) is used as an example of the difficulties to calibrate hyperspectrally. Results from a preflight solar radiation-based calibration are presented with a discussion of the uncertainties in such a method including the NISI-traceable and SItraceable aspects. Expansion on the concept of solar-based calibration is given with descriptions of methods that view the solar disk directly, illuminate a solar diffuser that is part of the sensor's inflight calibration, and illuminate an external diffuser that is imaged by the sensor. The results of error analysis show that it is feasible to achieve preflight calibration using the sun as a source at the same level of uncertainty as those of lamp-based approaches. The error analysis is evaluated and verified through the solar-radiation-based calibration of several of laboratory grade radiometers. Application of these approaches to NASA's upcoming CLARREO mission are discussed including proposed methods for significantly reducing the uncertainties to allow CLARREO data to be used for climate data records.

Thome, Kurtis↗