DGEN Aeropropulsion Research Turbofan (DART) Core/Combustor-Noise Infinite-Tube-Probe (ITP) Transfer Function
Direct measurements of turbofan engine core unsteady pressure is complicated by the extreme thermal environment within the engine, preventing currently available transducers from operating. It is necessary to use a remote measurement configuration such as an infinite-tube-probe (ITP) configuration in which the transducer is teed into a line pneumatically coupled with the location of interest and the other end of the ITP contains an "infinite" waveguide designed to prevent any reflections. This configuration has become a standard method for experiments concerning core noise. In order to relate the spectral pressure measurements obtained remotely with the ITP, a transfer (frequency response) function needs to be calculated based on a known pressure field. This is accomplished using a normal impedance tube at Glenn Research Center, where a flush-mounted microphone is used as a reference to the ITP signal in the calculation of the ITP's transfer function.