Search NASA⌕ Search

SEARCH · Search NASA

Results for “two-photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High-dimensional discrete Fourier transform gates with a quantum frequency processor

The discrete Fourier transform (DFT) is of fundamental interest in photonic quantum information, yet the ability to scale it to high dimensions depends heavily on the physical encoding, with practical recipes lacking in emerging platforms such as frequency bins. In this article, we show that d -point frequency-bin DFTs can be realized with a fixed three-component quantum frequency processor (QFP), simply by adding to the electro-optic modulation signals one radio-frequency harmonic per each incremental increase in d . We verify gate fidelity F W > 0.9997 and success probability P W > 0.965 up to d = 10 in numerical simulations, and experimentally implement the solution for d = 3, utilizing measurements with parallel DFTs to quantify entanglement and perform tomography of multiple two-photon frequency-bin states. Our results furnish new opportunities for high-dimensional frequency-bin protocols in quantum communications and networking.

97 MATHEMATICS AND COMPUTING↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗

Broadband polarization-entangled source for C+L-band flex-grid quantum networks

The rising demand for transmission capacity in optical networks has motivated steady interest in expansion beyond the standard C-band (1530–1565 nm) into the adjacent L-band (1565–1625 nm) for an approximate doubling of capacity in a single stroke. However, in the context of quantum networking, the L-band has yet to be fully leveraged with the suite of advanced tools for characterization and management available from classical lightwave communications. In this work, we demonstrate an ultrabroadband two-photon source integrating both C- and L-band wavelength-selective switches for complete control of spectral routing and allocation across 7.5 THz in a single setup. Polarization state tomography of all 150 pairs of 25-GHz-wide channels reveals an average fidelity of 0.98 and total distillable entanglement greater than 181 kebits/s. This source is explicitly designed for flex-grid optical networks and can facilitate optimal utilization of entanglement resources across the full C+L-band.

42 ENGINEERING↗

Non-Intrusive Measurements Using Femtosecond Laser in Atmospheric Pressure Plasma Jet

Femto-second (fs) lasers offer state-of-the art non-intrusive diagnostic capabilities in plasma flow environments. The diagnostics in plasma flows using a fs-laser that are relevant to this proposal include Two-photon Absorption Laser Induced Fluorescence (TALIF) for measuring the number density of an atomic species, and Femto-second Laser Electronic Excitation Tagging (FLEET) for performing velocity measurements in plasma flows. Various aspects of these diagnostics using fs-lasers are still an active domain of research. The TALIF technique has been used to measure the number density of atomic species in various plasma flow environments like atmospheric pressure plasma jet (APPJ) and arc-jet flows. This technique utilizes a fs-laser to excite an atomic species and the subsequent relaxation process through fluorescence is recorded to make measurements. A narrow band-pass filter is used to isolate the fluorescence signal that is in the infra-red regime. However, broad-band background emissions can potentially pass through the filter and induce noise in the TALIF signal. Particularly, arc-jet plasma flows inherently contain background emissions. In such plasma flow environments, in addition to the filter, the background-subtraction technique will play an important role in reducing the noise that is induced in the number density measurements using TALIF. The proposed research focuses on evaluating the effectiveness of a background-subtraction technique by measuring atomic oxygen using a femtosecond (fs) TALIF in APPJ with induced background emissions and comparing measurements obtained without inducing the emissions. Therefore, by quantifying the changes in the signal-to-noise ratio caused by a background-subtraction technique applied for APPJ, it will enable a better understanding of the uncertainties in the background subtracted fs-TALIF measurements for arc-jet plasma flows. In addition to this, FLEET will be used to obtain velocity in the APPJ, and the impact of background emissions will be analyzed. Under this effort, the experimenters and research personnel will gain the technical know-how in the operational and theoretical aspects of the advanced fs-laser-based diagnostic techniques. The knowledge gained in this process will then also directly be applied to a separate ONR funded project at the Aerodynamics Research Center (ARC), UT Arlington, related to arc-jet flow characterization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Direct Neutral Density Diagnostic for Fusion Edge Plasmas

As magnetically confined plasmas progress towards ignition and long pulse experiments, measurement and control of the neutral density in the plasma edge has become a critical issue for stability, formation of transport barriers, and fueling. Recent experiments by our research group have demonstrated that is possible to use two-photon absorption laser induced fluorescence (TA-LIF) to directly measure the density of neutral hydrogen in helicon sources and in the HIT-SI3 spheromak. While those experiments validated key elements of a diagnostic system that would enable similar measurements in tokamak plasmas, they did not fully address the issue of performance optimization in the presence of intense background light at the fluorescence wavelength and they also identified a number of other issues that must be resolved before successful TALIF neutral density measurements in a tokamak are likely to be achieved. Additional specific concerns raised during design reviews with the leadership of the DIII-D tokamak facility included: the minimum detection threshold for this TALIF diagnostic (currently ~ 5 x 10 15 m -3 ) and the rate at which neutral density measurements could be obtained. Improving the system performance to reduce the minimum detection threshold and demonstrating a faster rate of density determination are required to advance this diagnostic to the level where it could be considered for implementation on a major tokamak facility in the USA. The key issues that will be addressed through additional technological development are: validation of a new, chromatic aberration-free, xenon calibration scheme; increasing the output power of the laser; and suppression of background emission at the fluorescence wavelength through optimization of the collection optics and gating of the photomultiplier detector with a goal of obtaining a minimum detection threshold of 5 x 10 14 m -3 . Another key technological development, so far only tested in helicon source experiments, is the validation of Doppler-free TALIF as a means of obtaining higher speed, calibrated, neutral density measurements in tokamak-like conditions at the full cadence of the pulsed TALIF laser. In this work, we propose to complete these technological advancements through installation and testing of our prototype TALIF system on the proto-MPEX experiment at Oak Ridge National Laboratory (ORNL). The proto-MPEX facility will provide plasma conditions similar to the edge plasma of a major tokamak experiment but with pulse lengths and pulse repetition rates ideally suited for extensive development of a TALIF neutral density diagnostic. Measurement of the absolute neutral density in the edge of a magnetically confined plasma is necessary for plasma density control; calculation of charge-exchange power losses; control of plasma-wall interactions; determination of the braking of plasma flow; determination of the fuel mixture in deuterium-tritium plasma; and understanding the dynamics of the divertor region in the plasma edge. In terms of potential impact on the worldwide fusion program, we note that in burning plasma experiments, such as ITER, a 100 mJ/pulse Doppler-free TALIF diagnostic should be capable of directly measuring the deuterium/tritium (D/T) isotope ratio in the outer 0.5 to 1.0 m of the plasma radius. The D/T ratio is a critically important parameter for the control and optimization of burning plasmas. Therefore, development of the diagnostic system proposed here is also relevant to long-term US participation in diagnostic development for large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Equilibrium Plasma Interactions with Biomaterials, Biological Solutions and Tissues

Cold atmospheric pressure plasma discharges offer an abundant source of reactive oxygen and nitrogen species (RONS) at room temperature enabling unique interactions with biomaterials, biological solutions and tissues. These interactions particularly with living matter are presently an important intellectual frontier in plasma science with promising potential applications ranging from human health care to advanced biomaterial processing. Exciting case studies have been reported that illustrate the huge potential of cold atmospheric plasma technology in wound healing and cancer treatment. The interaction of plasma with conducting and dielectric biomaterials such as tissue strongly influences the plasma properties. In turn this changes the impact of the plasma on the biomaterial. Particularly in the case of living matter, liquid based solutions are ubiquitous which complicates interfacial processes. The lack of insight into the underlying mechanisms of the interaction of plasma with wounds and tumors is currently a bottleneck for the further development of the technology and gives rise to many interesting scientific questions. This project was focused on plasma properties and kinetics during plasma-biomaterial interactions. Both DC pulsed and RF driven atmospheric pressure plasma jets, extensively used by the plasma community were studied. The bio-interfaces included hydrogel as a tissue model, (saline) solutions, bacteria and virus. Plasma diagnostics used include Thomson scattering, Rayleigh scattering, Raman scattering, (two-photon absorption) laser induced fluorescence, optical emission spectroscopy, absorption spectroscopy, molecular beam mass spectrometry and fast imaging allowing to determine electron densities and temperatures, ionic species, reactive species including radicals, gas temperatures, gas composition, electric fields and solution components transferred to the gas phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Coherence Length in UndulAtor RAdiation (CLARA): Run 4 Proposal

The goal of the proposed experimental research is to investigate the quantum nature of “a particle in a ring” by studying a single 135-MeV electron, circulating in the IOTA storage ring and interacting with an undulator through single- and multi-photon emissions. The focus of this proposal will be two-photon undulator emissions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Target fabrication fields first NIF shot with new 3D-printed microfluidic target design

Capable of producing ultrafine features, two-photon polymerization (2PP) 3D printing made it possible to field a first-of-its-kind leak-proof liquid-filled diffraction target. These targets are used for shots aimed at using laser pressure instead of low temperatures turn water into ice. The shot is the product of months of design, assembly, and installation work by LSEO’s target fabrication team, in collaboration with 3D printing experts Widi Moestopo (MED) and Xiaoxing Xia (MED) and PLS researcher Neal Bhandarkar.

42 ENGINEERING↗

New Deformation Mechanisms in Nanocrystalline Nano-porous Small Scale Metals as Defined by Kinetically-driven Microstructures

This report describes recent advances in the design and fabrication of nanostructured metallic pillars with hierarchical microstructures using a novel nanoscale additive manufacturing approach. Through a hydrogel-infusion-based two-photon lithography (TPL) method, we successfully fabricated 3D nickel nanopillars exhibiting both nanocrystalline and nanoporous features. The resulting “bamboo-like” internal architecture comprises 30–50 nm grains and voids with similarly scaled pores. These geometrically tunable pillars, with diameters ranging from ~130 to 550 nm, serve as an ideal platform for probing deformation mechanisms in structurally heterogeneous metals at the nanoscale.

36 MATERIALS SCIENCE↗

Interactions of a Microdischarge with a Premixed Flame (Final Technical Report)

In this project we introduced an experimental platform that facilitates the study of the two-way interaction of plasma and flame, and the exploration of the impact of the spatial location of the discharge on its kinetics, in a controlled environment. The experimental platform is a mesoscale CH4/air premixed flame burner that also acts as a dielectric barrier discharge (DBD) operated by nanosecond pulsed voltage. A unique feature of this setup is that the DBD utilizes transparent electrodes, made of Indium Tin Oxide (ITO), to unlock optical access along the line-of-sight parallel to the dominant electric field. This platform is suitable to study both the forward problem (impact of plasma-on-flame), which manifests itself as a modified flame speed as well as flame wrinkling; and the backward problem (impact of flame-on-plasma), which includes plasma regime transitions, between microdischarges and uniform modes, driven by the flame passage. Prior work at MIT has focused on electrical measurements and direct imaging studies of the plasma-flame interaction through the ITO electrode. This project, which was awarded experimental runtime at the Low-temperature Plasma Research Facility (PRF) at Sandia National Laboratories, quantifies the flame-plasma interaction through temporally resolved measurement of key radicals (oxygen atom, O) produced by the nanosecond repetitively pused discharge (NRPD) in an individual microdischarge, using two-photon absorption laser-induced fluorescence (TALIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New correlated numerical methods for attosecond molecular single and double ionization

This project resulted in the development of ASTRA, a new molecular ionization code capable of describing single and double ionization processes in polyatomic molecules with correlated electrons and time-dependent fields. Key achievements include: (i) the development of the PRISM hybrid-integral library enabling core-ionization and high-angular-momentum convergence; (ii) implementation of time-dependent Schrödinger equation solvers for pump–probe spectroscopies; (iii) validation against experimental and theoretical benchmarks for atoms and molecules; and (iv) extension to two-photon double ionization using the finite-pulse virtual-sequential model. These developments establish ASTRA as a versatile platform for attosecond molecular dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

Analysis and Mitigation of Pulse-Pile-Up Artifacts in Plasma Pulse-Height X-ray Spectra

Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate and detector-electronics-formed pulse shape then occur. Here, we focus on weak high energy tails in X-ray spectra, important for measurements on partially ionized, warm (50–500 eV average electron energy), pure hydrogen plasma. A first-principles two-photon pulse-pile-up model is derived specific to trapezoidal-shaped pulses; quantitative agreement is found between the measurements and the model’s predictions. The model is then used to diagnose pulse-pile-up tail artifacts and mitigate them in relatively low count-rate spectra.

2-photon↗

Simultaneous Two- and Three-Photon Deep Imaging of Autofluorescence in Bacterial Communities

The intrinsic fluorescence of bacterial samples has a proven potential for label-free bacterial characterization, monitoring bacterial metabolic functions, and as a mechanism for tracking the transport of relevant components through vesicles. The reduced scattering and axial confinement of the excitation offered by multiphoton imaging can be used to overcome some of the limitations of single-photon excitation (e.g., scattering and out-of-plane photobleaching) to the imaging of bacterial communities. In this work, we demonstrate in vivo multi-photon microscopy imaging of Streptomyces bacterial communities, based on the excitation of blue endogenous fluorophores, using an ultrafast Yb-fiber laser amplifier. Its parameters, such as the pulse energy, duration, wavelength, and repetition rate, enable in vivo multicolor imaging with a single source through the simultaneous two- and three-photon excitation of different fluorophores. Three-photon excitation at 1040 nm allows fluorophores with blue and green emission spectra to be addressed (and their corresponding ultraviolet and blue single-photon excitation wavelengths, respectively), and two-photon excitation at the same wavelength allows fluorophores with yellow, orange, or red emission spectra to be addressed (and their corresponding green, yellow, and orange single-photon excitation wavelengths). We demonstrate that three-photon excitation allows imaging over a depth range of more than 6 effective attenuation lengths to take place, corresponding to an 800 micrometer depth of imaging, in samples with a high density of fluorescent structures.

59 BASIC BIOLOGICAL SCIENCES↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

Characterization and Engineering of Entangled Spatial modes in Four-wave Mixing

We show the presence of a large number of pairwise-entangled spatial modes generated in four-wave mixing by calculating the spatial Schmidt spectrum from the experimentally reconstructed two-photon amplitude. By manipulating the input pump momentum, we demonstrate a modification of the spatial Schmidt modes.

Marino Valle, Alberto↗

A Measurement of the Neutron Electromagnetic Form Factor Ratio from a Rosenbluth Technique with Simultaneous Detection of Neutrons and Protons

The internal structure of protons and neutrons provides insight into both the dynamical behavior of the constitute quarks and gluons, and emergent properties of the nucleons (such as mass, spin, and electromagnetic distributions). Elastic electron-nucleon scattering can probe the elastic electromagnetic form factors of the nucleon. The electric and magnetic form factors, respectively, encode information about the internal charge and magnetization distributions within the nucleon. Precision data for these form factors, over a broad range of the four-momentum transfer squared, Q^2, can benchmark theoretical models describing the strong interaction of nuclear physics. The Super BigBite Spectrometer (SBS) program in Hall A at Jefferson Lab, is a series of high-precision experiments which seek to significantly extend the Q^2 reach of previous data for the nucleon electromagnetic form factors. The first two experiments of this program are known as G_M^n and the neutron Two Photon Exchange (nTPE) and the data were collected from October 2021 to February 2022. Both experiments were conducted with the simultaneous measurement of D(e,e'n) and D(e,e'p) reactions for quasi-elastic electron-deuteron scattering. The scattered electrons were detected in the BigBite Spectrometer, which features multiple large-acceptance Gas Electron Multiplier (GEM) detectors. The Super BigBite Spectrometer provided simultaneous detection of scattered nucleons, and utilized a large acceptance dipole magnet and Hadron Calorimeter (HCal). The G_M^n experiment provides precision measurements of the neutron magnetic form factor, via the ratio method, over a Q^2 range of 3.0 to 13.5 (GeV/c)2. From this data analysis, preliminary values for G_M^n/µ_n G_D are extracted. For Q^2=4.48 (GeV/c)2 we find G_M^n/µ_n G_D=0.9546±0.0132 and for Q^2=4.476 (GeV/c)2 we find G_M^n/µ_n G_D=0.9563±0.0110. These preliminary G_M^n/µ_n G_D values are more precise than existing world data in this Q^2 regime and are consistent with the most recent parameterization of the G_M^n/µ_n G_D world data. The nTPE experiment provides a first measurement of the neutron Rosenbluth Slope and seeks to quantify the two-photon exchange(TPE) contribution to elastic electron-neutron scattering at a fixed Q^2=4.5 (GeV/c)2 with two different beam energies and scattering angle values. For data of the proton form factor ratio, µ_p G_E^p/G_M^p, significant discrepancies exist between values obtained from Rosenbluth Separation and polarization transfer measurement, particularly at large Q^2, and TPE contributions are thought to resolve this discrepancy. The impacts of TPE contributions have not yet been experimentally established for the neutron. From the data analysis presented in this dissertation, a preliminary result for the neutron Rosenbluth Slope is found as S^n=(G_E^n )^2/t_n (G_M^n )^2=0.0916±0.0476 for Q^2=4.48 (GeV/c)2. This value of the neutron Rosenbluth Slope is consistent with the world data extrapolation and the absence of large TPE corrections.

Wertz, Ezekiel [Thomas Jefferson National Accelera↗

Spatiotemporal Reaction Dynamics Control in Two‐Photon Polymerization for Enhancing Writing Characteristics

Since 2001, 3D microfabrication based on two‐photon polymerization (TPP) has drawn extensive attention and interest in biology, optics, photonics, material science, and high‐energy physics. The in‐volume fabrication capability due to the threshold behavior of two‐photon absorption enables TPP higher flexibility compared with other nanofabrication techniques. However, as determined by the in‐volume fabrication feature as well as various reaction dynamics, the writing characteristics of TPP, such as throughput, accuracy, surface quality, and fabrication capability, are still limited. Herein, a comprehensive study is performed on the spatiotemporal behavior of reaction dynamics during TPP fabrication, mainly focusing on spatiotemporal characteristics of radical diffusion, photothermal effect, microscale mechanics, and voxel stacking process. Based on the study, a nonsequential fabrication method is established to simultaneously improve key writing characteristics of TPP and realize sharp features, high speeds, large overhang structure, and smooth surfaces. The method established in this work can be applied to improve the performance of functional devices for various fields.

36 MATERIALS SCIENCE↗